Records from 1985 to 2003. Most recent: inspection, 31 October 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
31 October 2003
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1939674
18 September 2000
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 822209
9 September 2000
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1393523
20 August 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 45715
10 August 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 281013
8 August 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 692736
10 July 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 279567
23 June 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 171801
11 June 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 136533
11 June 2000
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 145914
9 June 2000
Deficiency Check · Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1421890
12 February 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 775045
26 January 1998
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 779738
20 January 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1111899
13 January 1998
Control Verification · MARPOL Annex I Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1394881
23 December 1997
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 27388
16 December 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 645385
13 December 1997
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 137817
20 January 1994
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851807
22 January 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1431179
21 January 1993
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1140909
17 January 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 355727
17 January 1993
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373775
16 January 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341511
16 January 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 901568
14 August 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 493352
14 August 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 920534
24 January 1990
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 968187
21 January 1990
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1216686
21 January 1989
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 894576
18 August 1988
Deficiency Check · Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1035604
18 August 1987
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1338244
10 August 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 310711
10 August 1986
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1306376
23 August 1985
Control Verification
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1297458
Accommodation/Occupational Safety
Issued 9 September 2000
Resolved
REMOVE AND/OR PROPER STOW VARIOU STORAGE BOTTLES ON THE AFT MOORING DECK
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
REPAIR LIGHT AND PUMP WIRING IN POOL PUMP ROOM.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
REPAIR LIGHT FIXTURE IN WATER WATER #16.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
SECURE EXPOSED POWER CORD ON ENTERTAINMENT CONSOLE IN CHILDRENS REC AREA.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Fire Fighting
Issued 9 September 2000
Resolved
REDUCE FIRE LOAD (CLEAN) AND REMOVE IMPROPER WIRING IN MAIN THEATER SOUND BOOTH AND IN BACK STAGE AREA.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Fire Fighting
Issued 9 September 2000
Resolved
PROVIDE SPRINKLER HEADS IN MAIN THEATER SOUND BOOTH OR APPROVAL FROM ADMIN.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
PROVIDE LATCHES ON ALL TECHNICAL LOCKERS IN PASSENGERS SPACES.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
REPAIR LIGHT FIXTURE IN UPHOLSTERY SHOP.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
REPLACE OR PROPERLY SECURE WIRES TO RAW WATER PUMP FOR THE SEWAGE SYSTEM. PUMP MISSING AND WIRING EXPOSED.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Unknown
Issued 9 September 2000
Resolved
PERFORM CREW FIRE AND ABANDON SHIP DRILLS.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Fire Fighting
Issued 9 September 2000
Resolved
REMOVE BOXES FROM STORAGE SPACE 527V
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Fire Fighting
Issued 9 September 2000
Resolved
REPAIR DOOR TO FAN ROOM OUTSIDE OF MAIN LAUNDRY.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Fire Fighting
Issued 9 September 2000
Resolved
REPAIR INSULATION IN PASSAGEWAY OVERHEAD OUSTSIDE THE MAIN LAUNDRY.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
PROVIDE LIGHT FIXTURE IN THE MAIN ENGINEERING STORE ROOM AND REMOVE TEMP LIGHTING.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Construction/Loadline
Issued 9 September 2000
Resolved
DETERMINE SOURCE OF WATER LEAK AND REPAIR HOLE IN OVERHEAD IN THE MAIN LAUNDRY STORE ROOM
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Electrical
Issued 9 September 2000
Resolved
REMOVE TEMP WIRING FROM PHOTO LAB.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Accommodation/Occupational Safety
Issued 9 September 2000
Resolved
PROPERLY STOW OXYGEN BOTTLES IN FIRE LOCKERS.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Lifesaving
Issued 9 September 2000
Resolved
CLEAN UP AREA OF SEAGE TANKS WHERE REPAIRS WERE MADE.
Condition: Unknown
Due 9 September 2000
Resolved 9 September 2000
Fire Fighting
Issued 9 June 2000
Resolved
Provide Condition Of Class for fixed CO2 system for engine room spaces, prior to sailing. Stop valves are removed and sent out for lapping.
Condition: Unknown
Due 9 June 2000
Resolved 19 June 2000
Construction/Loadline
Issued 9 June 2000
Resolved
Water Tight Doors #14 and # 2 hydraulic leak around hand pump.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Fire Fighting
Issued 13 January 1998
Resolved
Prove proper operation of main entrance door leading into laundry. SOLAS 60 II/38.d
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Fire Fighting
Issued 13 January 1998
Resolved
Remove all excessive equipment from projector room, deck 6. SOLAS 74 II- 2.4.4.2
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Fire Fighting
Issued 13 January 1998
Resolved
Remove all counters and equipment from pantry, deck 10. SOLAS 74 II-2/41- 2.4.4.2
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Fire Fighting
Issued 13 January 1998
Resolved
Remove all equipment and combustibles from storeroom 548V under stairway, deck 6. SOLAS 74 II-2.4.4.1
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Electrical
Issued 13 January 1998
Resolved
Prove proper installation of slot machines once installed. Vessel may not take on passengers until proper installation is examined by a attending Coast Guard inspector. SOLAS 60 II/23.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Fire Fighting
Issued 13 January 1998
Resolved
Remove excessive gear and combustibles from telephone room, deck 11. SOLAS 74 II-2/41-2.4.4.2.
Condition: Unknown
Due 13 January 1998
Resolved 13 January 1998
Fire Fighting
Issued 22 January 1993
Resolved
ADJUST FSD #62 TO OPERATE PROPERLY PRIOR TO THE NEXT CONTROL VERIFICATION EXAMINATION.
Condition: Unknown
Due 22 January 1993
Resolved 22 January 1993
Fire Fighting
Issued 17 January 1993
Resolved
Prove proper operation of all vessels sliding "CASTADOR" fire doors. All doors must be capable of being opened by only one person as required by Solas II-2/30-3. This requirement to be corrected to the satisfaction of the cognizant OCMI at next U.S. port.
Condition: Unknown
Due 17 January 1993
Resolved 17 January 1993