MONA LISA

MONA LISA is a 1966 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in January 2010, along with 39 deficiencies — 1 with no resolution recorded —.

Records from 1985 to 2010. Most recent: inspection, 22 January 2010.

Built
1966
Last inspected
22 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6512354 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
221475
Flag
UNITED KINGDOM
—
Maury page id
psix-221475

Inspections, by type

…with no type recorded33
…past their stated due date1
Years with a record 19 calendar years (1985–2010)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it28891 - Convention (Subpart B), Gross Ton
28891 - Simplified, Gross Ton
11005 - Simplified, Net Ton
5572 - Dead Weight, Ton
11005 - Convention (Subpart B), Net Ton
23263 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 64

22 January 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3666260
22 January 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3668217
13 October 2005 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2514556
12 October 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2512792
8 October 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2510376
4 October 2005 COC-CVE Annual · ISPS III Exam · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2508565
8 November 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2237166
5 November 2004 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2235461
3 November 2004 COC-CVE Initial
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2233634
1 November 2004 PII Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2232146
14 January 2004 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1983887
8 May 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1614424
8 May 2002 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1614988
6 May 2002 MARPOL Annex I Examination · MARPOL Annex V Examination · Quarterly Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1613612
6 January 2002 Quarterly Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1476815
7 September 2001 Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1389464
26 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 286428
26 January 2001 Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 825361
5 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 427045
5 March 1999 Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1406496
25 February 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425987
9 April 1998 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 414790
5 November 1997 Type not recorded
No type recorded · Activities Europe · Activity 1414898
1 April 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 402096
14 March 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 401609
14 March 1997 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1374910
16 December 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 398634
15 December 1996 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1371610
15 March 1996 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405885
8 January 1996 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 879649
18 December 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 386054
18 December 1995 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1396418
30 March 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 840232
17 March 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 145806
11 March 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 375838
10 March 1995 Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 862687
14 March 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 365205
14 March 1994 MARPOL Annex V Examination · Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1387487
25 September 1993 MARPOL Annex I Examination · Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846612
9 March 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 356817
9 March 1993 Control Verification · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1146378
27 November 1992 Certificate of Compliance
Administrative · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 827866
7 March 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 349349
7 March 1992 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 961134
6 November 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 340225
6 November 1990 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 910554
18 August 1990 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1221142
27 May 1990 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 337290
27 May 1990 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1229423
21 August 1989 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1035562
26 May 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 330595
26 May 1989 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1039747
11 August 1988 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1345026
13 May 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 323259
13 May 1988 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 889792
28 August 1987 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1004151
25 June 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 317001
19 June 1987 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1021599
15 June 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 316784
2 June 1987 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 316551
18 March 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1325723
16 December 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1011808
14 December 1985 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1302221
22 January 1985 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 299954

Deficiency record · 39

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 22 January 2010 Resolved
Vessle does not posses an approved non-tank vessle resopnce plan (NTVRP). Vessle has submitted a NTVRP and it is in "pending" status. 33U.S.C1321(j)(5)
Action required: 705 - Other - as specified
Due 21 February 2010
Resolved 19 March 2010
Resolution: Vessel has been added to the VRP web site and is in "interim ops" status.
Fire Fighting › Means of Escape › Blocked
Issued 4 October 2005 Resolved
Prior to embaking or disembarking passengers in a U.S. port, provide a secondary means of egress from crew cabins in MVZ #1 on Deck 5 (Baja Deck). A hatch, operable from the interior, to be installed within the existing hatch at FR 114-117 (centerline) on Deck 6.
Due 31 October 2005
Resolved 12 October 2005
Fire Fighting › Means of Escape › Blocked
Issued 4 October 2005 No resolution recorded
Prior to embarking or disembarking passengers in a U.S. port, and until completion of installation of escape hatch described in item #18 of this activity (Item #1 on CG-5437B dated 04 Oct 2005 BOSMS), Provide a written instruction assigning crew members to open the hatch on Deck 6 FR 114-117 (centerline) from above, in case of emergency.
Action required: 705 - Other - as specified
Due 31 October 2005 — due date passed with no resolution recorded
Fire Fighting › Structural - A Class Divisions › Doors
Issued 4 October 2005 Resolved
Prior to embarking or disembarking passengers in a U.S. port, permanently repair fire screen doors #3 & 4 in MVZ #1 IWO latch openings on door frams.
Due 31 October 2005
Resolved 12 October 2005
Lifesaving › Embarkation Appliances/Stations › Side Ropes
Issued 4 October 2005 Resolved
Prior to embarking or disembarking passengers in a U.S. port, provide man ropes for lifeboats that are of sufficient length to reach the waters edge with a 15 degree list to the opposite side of vessel.
Due 31 October 2005
Resolved 12 October 2005
Fire Fighting › Ventilation Systems › Ducts
Issued 4 October 2005 Resolved
Prior to embarking or disembarking passengers in a U.S. port, make accessible without tools and mark with proper IMO symbol 2 manual fire dampers in overhead in Reception locker, and 1 manual fire damper in overhead in main reception area on Deck 6.
Due 31 October 2005
Resolved 12 October 2005
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 4 October 2005 Resolved
Prior to embarking or disembarking passengers in a U.S. port, provide permanent closure and structural insulaltion (to achieve A-60 boundary) for fwd door in Compactor Room on Deck 5 (Baja Deck).
Due 31 October 2005
Resolved 12 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 4 October 2005 Resolved
Provide proper covers for lights in Caprpenters Workshop (Deck 6, Stbd), A/C Workshop (Deck 5) and Crew Recreation Room (Tween Deck, Port).
Action required: 705 - Other - as specified
Due 31 October 2005
Resolved 12 October 2005
Operations/Management › Drills/Instruction › Safety Orientation
Issued 3 November 2004 Resolved
Emergency egress signage missing in numerous locations thru-out the vessel passenger and crew areas. This to be recitified prior to embarking or disembarking passengers in U.S. waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 November 2004
Resolved 4 October 2005
Resolution: Examined egress signage during walk-thru. Signage found satisfactory.
Fire Fighting › Combustible Materials › Primary Deck Coverings
Issued 3 November 2004 Resolved
Stairways leading from upper sun deck to the embarkation deck found equiped with wooden stair treads vs. steel plates backing up the wooden treads as required by SOLAS II-2 41-2 /4.7. This to be addressed by the vessel administration no later than Nov 30, 2004.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 4 October 2005
Resolution: Examined satisfactory installation of steel plate installed as backing for wooden treads.
Fire Fighting › Automatic Sprinkler System › Stop Valves
Issued 3 November 2004 Resolved
Cold boxes, Chill boxes and Walk-in Reefer Boxes found with non-functional inoperable automatic sprinkler systems as required by SOLAS 74 II-2 /12. This to be repaired to satisfaction of Lloyds no later than Nov 8, 2004.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 8 November 2004
Resolution: Cleared via written class report dated this date with Lloyds report ID# MMI-0400303
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 3 November 2004 Resolved
Coating on galley entry from Coral deck not coated with "Low Flame Spread" coating as required by SOLAS 74 II-2/34 - 3.1. This to be rectified to satisfaction of Lloyds no later than Nov 8, 2004.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 8 November 2004
Resolution: Cleared via written class report dated this date with Lloyds report ID# MMI-0400303
Operations/Management › Passenger Operations › Safety Orientation
Issued 3 November 2004 Resolved
Prio to embarking or disembarking passengers in U.S. waters the vessel must satisfactorily meet the requirements as specified in MSC letter #H2-0402878 Dated Nov 2, 2004 and succesfuly pass a CVE exam at that time.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 October 2005
Resolved 4 October 2005
Resolution: Master presented a copy of MSC letter #H2-0402878 with signature of [name withheld] (NYCMI) attesting to satisfactory completion of all items on the letter on 03Nov2004. Several items were spot checked and found satisfactory.
Fire Fighting › Means of Escape › Blocked
Issued 3 November 2004 Resolved
Passengers in MVZ #1 cannot escape from the interior of the vessel and get to the lifeboat embarkation deck without first going thru MVZ #2 and/or back thru the vessel interior. This to be corrected prior to embarking or disembarking passengers in U.S. waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared IAW MSC letter H2-0503901 dated 24 Mar 2005.
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 3 November 2004 Resolved
Vessel cannot provide written documentation from their administration that attests to the vessel satisfactorily achieving the minimum requirements of the Retroactive Fire Safety Amendments of 1992 or 1995.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: LRS Surveyor on-site during inspection. The surveyor affirmed that issuance of Pax Vsl Safety Certificate issued by LRS Jan 2005 constitutes attestation that the vessel has achieved compliance with RFSA requirements.
Fire Fighting › Means of Escape › Stairways
Issued 3 November 2004 Resolved
Vertical escape route from auxiliary Engine Room is not independant of a watertight door as required by SOALS 60/68 and SOLAS 74/28. This to be addressed byt he vessel's administration prior to embarking or disembarking passengers in US waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared IAW MSC letter H2-0503901 dated 24 Mar 2005.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 3 November 2004 Resolved
The frozen food area located at frame 103 - 115 (Emerald deck) is equipped with only a vertical ladder as the only means of escape independant of a watertight door in contrary to SOLAS 60/68 and SOLAS 74/28. This to be addressed by the administration prior to embarking or disembarking pass in US waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared IAW MSC letter H2-0503901 dated 24 Mar 2005.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 3 November 2004 Resolved
The fish thawing room located at frame 91 - 103 (Emerald deck) is equipped with only a vertical ladder as the only means of escape independant of a watertight door in contrary to SOLAS 60/68 and SOLAS 74/28. This to be addressed by the administration prior to embarking or disembarking pass in US waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared IAW MSC letter H2-0503901 dated 24 Mar 2005.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 3 November 2004 Resolved
The crew cabin area located at frame 91 - 103 (Tween deck) is equipped with only a vertical ladder as the only means of escape independant of a watertight door in contrary to SOLAS 60/68 and SOLAS 74/28. This to be addressed by the administration prior to embarking or disembarking pass in US waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared IAW MSC letter H2-05-3901 dated 24 Mar 2005.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 3 November 2004 Resolved
The crew cabin area located at frame 67-79 (both the Tween AND Dolphin decks) is equipped with only a vertical ladder as the only means of escape independant of a watertight door in contrary to SOLAS 60/68 and SOLAS 74/28. This to be addressed by the administration prior to embarking or disembarking pass in US waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared IAW MSC letter H2-0503901 dated 24 Mar 2005.
Fire Fighting › Means of Escape › Enclosed Stairway
Issued 3 November 2004 Resolved
The stabilizer room located at frame 91 - 103 (Tank top deck) is equipped with only a vertical ladder as the only means of escape independant of a watertight door in contrary to SOLAS 60/68 and SOLAS 74/28. This to be addressed by the administration prior to embarking or disembarking pass in US waters.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared IAW MSC letter H2-0503901 dated 24 Mar 2005.
Fire Fighting › Structural - A Class Divisions › Evacuation Stations
Issued 3 November 2004 Resolved
Vessel does not meet the requirements of SOLAS 74 II-2/41-2/4.5 in that spaces other than public spaces, corridors, lifts, toilets and special catagory spaces are not permitted to directly access stairway enclosures. This to be addressed by the vessel's administration prior to embarking or disembarking pass in US Waters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: Cleared. 1 new def was written to specify the location.
Fire Fighting › Structural - A Class Divisions › Pantries
Issued 3 November 2004 Resolved
Pantry on Baja deck found with direct access into the main stair tower at frames 114 - 120. This to be addressed by vessel's administration prior to embarking or disembarking passengers in US waters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: All pantries opening into stairways have been either closed off or cooking equipment has been removed.
Fire Fighting › Structural - A Class Divisions › Pantries
Issued 3 November 2004 Resolved
Pantry on Coral deck found with direct access into the main stair tower at frames 114 - 120. This to be addressed by vessel's administration prior to embarking or disembarking passengers in US waters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: All pantries opening directly into stairways have been either closed off or all cooking equipment has been removed.
Fire Fighting › Structural - A Class Divisions › Pantries
Issued 3 November 2004 Resolved
Pantry on Riviera deck found with direct access into the main stair tower at frames 36 - 42. This to be addressed by vessel's administration prior to embarking or disembarking passengers in US waters.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 November 2004
Resolved 4 October 2005
Resolution: All pantries opening directly into stairways have been either closed off or all cooking equipment has been removed.
Pollution Prevention/Response › Prevention Equipment
Issued 6 May 2002 Resolved
Perform Test of effluent from MSD. Perform maintenance of MSD as needed to comply with IMO discharge standards. Recent tests of effluent by vessel indicates total suspended solids in excess of 100 mg/l. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 May 2002
Resolved 8 May 2002
Resolution: Cleared by MSO HAMPTON ROADS.
Accommodation/Occupational Safety › Occupational Safety
Issued 6 May 2002 Resolved
[name withheld] Photographic waste containers as required by safety management system.
Due 8 May 2002
Resolved 8 May 2002
Resolution: Cleared by MSO HAMPTON ROADS.
Fire Fighting
Issued 5 March 1999 Resolved
PROVIDE STAIRWAY ESCAPE ROUTE FROM FOC'SLE, FOR CREW CABINS IN ZONE 1 (SOLAS 60 REG 68.4.1)
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 5 March 1999 Resolved
RESOLVE ISSUE BETWEEN MCA AND USCG CONCERNING MANUAL CONTROL VALVES FOR COLD STORAGE ROOM SPRINKLERS (MAKE FULLY AUTOMATIC; SOLAS 60 REG 41-2.4.5)
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Lifesaving
Issued 5 March 1999 Resolved
ENSURE ALL MACHINERY SPACE WATERTIGHT DOOR ALARM BELLS AR AUDIBLE, OR INSTALL WARNING FLASHING LIGHTS IN ACCORDANCE WITH SOLAS.
Condition: Unknown
Due 5 March 1999
Resolved 15 March 1999
Fire Fighting
Issued 5 March 1999 Resolved
RESOLVE ISSUE AND PROVIDE FLAG STATE CERTIFICATION OF COMPLIANCE WITH SOLAS60 REG 49(b) - BULKHEAD AND CEILING LININGS.
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 5 March 1999 Resolved
PROPERLY MARK INTERNATIONAL SHORE CONNECTIONS WITH SOLAS SYMBOL.
Condition: Unknown
Due 5 March 1999
Resolved 15 March 1999
Fire Fighting
Issued 5 March 1999 Resolved
RESOLVE ISSUE/ADDRESS CLOSURE RATE OF ROLLER SHUTTER FIRE SCREEN DOORS AND ABILITY OF ONLY 1 PERSON TO OPEN (SOLAS 60 REG 38(e)).
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 18 December 1995 Resolved
REPAIR OR REPLACE FIRE SCREEN DOOR L3 ON LIDO DECK.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Lifesaving
Issued 18 December 1995 Resolved
LOWER AND EXERCISE ALL PORT LIFEBOATS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Fire Fighting
Issued 18 December 1995 Resolved
ADJUST THE FOLLOWING FIRE SCREEN DOORS: RIVIERA DECK R-7 AND F-11; BAJA DECK 1B AND TWEEN DECK FD-5.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995
Fire Fighting
Issued 13 May 1988 Resolved
FIRE SCREEN DOORS NOT LATCHING OR NOT CLOSING - RIVIERA DECK - 3,11,17. ALOHA DECK - 1,3,4,7,.9,20. BAJA DECK - 4,7,13,14. CORAL DECK - 27. DOLPHIN DECK - 9. TWEEN DECK - 6,7,14,17,19,24,26,28,29,30,31. EMERALD DECK - 5.
Condition: Unknown
Due 13 May 1988
Resolved 13 May 1988
Documentation
Issued 2 June 1987 Resolved
VESSELS MASTER HAS NOT SIGNED OIL TRANSFER BOOK SINCE MARCH 11, 1987.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987
Documentation
Issued 2 June 1987 Resolved
DURING INSPECTION OF THE OILY/WATER SEPARATER THE CHIEF ENGINEER COULD NOT LOCATE THE OIL DISCHARGE PROHIBITED PLACARD. THE PLACARD WAS TAKEN DOWN DURING PAINTING OF THE SEPARATER AND NOT PUT BACK UP.
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.