DYNAMIKOS is a 1966 tank ship. The Coast Guard has recorded 2 inspections since 1984, most recently in July 1985, along with 4 deficiencies.

Records from 1984 to 1985. Most recent: inspection, 29 July 1985.

Built
1966
Last inspected
29 July 1985
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6601466 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
221553
Flag
GREECE
—
Maury page id
psix-221553

Inspections, by type

…with no type recorded2
Years with a record 2 calendar years (1984–1985)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 41 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it48801 - Regulatory (Subpart C or D), Gross Ton
26485 - Regulatory (Subpart C or D), Net Ton
80945 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

29 July 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 303307
9 December 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 299234

Deficiency record · 4

Deck/Cargo
Issued 29 July 1985 Resolved
46CFR30.10-25 THE VESSEL HAD SEVERAL PV VENTS THAT CONTAINED FLAME SCREENS THAT DID NOT MEET THE REQUIREMENT FOR MESH SIZE.THERE WERE SEVERAL PV VENTS THAT HAD FLAME SCREENS WITH RIPS,TEARS AND HOLES THAT WOULD ALLOW ENTRY INTO THE CARGO TANK.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 July 1985 Resolved
1974 SOLAS, CHAPTER II-2, REGULATION 20, PARA. 1, AS AMENDED 20 NOV 1981; THE VESSEL'S FIRE CONTROL PLAN WAS NOT UP TO DATE.THE BOARDING TEAM REVIEWED THE FIRE CONTROL PLAN AND NOTED THAT IT DID NOT SHOW ANY OF THE LOCATIONS OF THE FIREMEN'S OUTFITS & EMERGENCY EQUIPMENT.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 July 1985 Resolved
1974 SOLAS, CHAPTER II-2, REGULATION 17, PARA.1.2,AS AMENDED 20 NOV 1981; THE VESSEL DID NOT HAVE FOUR ADEQUATE FIREMEN'S SUITS.THE VESSEL HAD TWO SUITS THAT WERE NEW BUT THE OTHER TWO HAD EXTENSIVE DELAMINATION OF THE OUTER WATER PROOF SURFACE.
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 29 July 1985 Resolved
1974 SOLAS, CHAPTER II-2, REGULATION 20, PARA 2, AS AMENDED 20 NOV 1981 THE VESSEL DID NOT HAVE THE FIRE CONTROL PLAN OR BOOKLET POSTED OUTSIDE THEDECKHOUSE IN WEATHER-TIGHT CONTAINER.THE BOARDING TEAM FOUND THE FIRE CON- TROL PLAN PERMANENTLY MOUNTED IN A PICTURE FRAME,INSIDE THE DECK HOUSE
Condition: Unknown
Due 1 August 1985
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.