MAURY USCG vessel records Sign in
← All vessels

MAESTRO

MAESTRO is a 1966 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 1986, most recently in October 1995, along with 31 deficiencies.

Records from 1986 to 1995. Most recent: inspection, 20 October 1995.

Built
1966
Last inspected
20 October 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6604834 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
221575
Flag
GREECE
—
Maury page id
psix-221575

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (1986–1995)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it12000 - Convention (Subpart B), Gross Ton
8630 - Regulatory (Subpart C or D), Gross Ton
2930 - Dead Weight, Ton
4160 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

20 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 1079194
15 February 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1409080
13 January 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 363811
13 January 1994 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1403721
20 November 1993 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841121
2 February 1992 Uninspected Other
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 948151
24 March 1991 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1242361
19 January 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 928787
22 December 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 908248
7 February 1990 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1229949
24 January 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 328098
24 January 1989 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 892528
8 January 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 327784
8 January 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1196090
25 July 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 310381
13 July 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 503375
10 July 1986 Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 994549
8 July 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 310010

Deficiency record · 31

Fire Fighting
Issued 13 January 1994 Resolved
COMBUSTIBLES STOWED IN FAN SPACE ON NEREUS DECK STBD SIDE NEXT TO STAIR #2.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Fire Fighting
Issued 13 January 1994 Resolved
FIRE HOSES REQUIRE DOCUMENTATION FROM FLAG OR CLASS STATING THAT THEY HAVE BEEN SATASFACTORILY TESTED.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Electrical
Issued 13 January 1994 Resolved
EXPOSED WIRE ENDS ON STAGE INSIDE CINEMA REQUIRES REPAIR._x001C_
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 13 January 1994 Resolved
DISCREPANCY EXISTS BETWEEN PASSENGER SHIP SAFETY CERTIFICATE REQUIRED NO. OF LIFERAFTS AND ACTUAL NO. ONBOARD
Condition: Unknown
Due 15 June 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 13 January 1994 Resolved
FIRE SCREEN DOOR ON POSIDEON DECK LEADING TO STAIR #3 IN NEED OF REPAIR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Fire Fighting
Issued 13 January 1994 Resolved
PROPERLY LABEL ALL FIRE SCREEN DOORS THROUGHOUT THE VESSEL. DOORS ARE NOT LABELED AS SUCH._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Construction/Loadline
Issued 13 January 1994 Resolved
MAKE PROPER PERMANENT REPAIRS TO DRAIN LINES LOCATED ON PORT SIDE FORWARD ABOVE THE STAGE IN THE CINEMA.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 13 January 1994 Resolved
PROVIDE DOCUMENTATION FROM THE FLAG AFTER WITNESSING PROPER OPERATION OF #3LIFEBOAT ENGINE.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Fire Fighting
Issued 13 January 1994 Resolved
RESUBMITT VENTILATION DRAWING TO FLAF ADMINISTRATION FOR APPROVAL SHOWING ALL MODIFICATION TO VENT SYSTEM. PROVIDE COPY TO USCG FOR REVIEW.
Condition: Unknown
Due 15 February 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 13 January 1994 Resolved
PROVIDE DOCUMENTATION THAT ALL SCBA BOTTLES HAVE BEEN REFILLED PRIOR TO SAILING.
Condition: Unknown
Due 15 February 1994
Resolved 25 January 1994
Lifesaving
Issued 13 January 1994 Resolved
PROPERLY REPAIR THE LIFERAFT BOARDING LADDERS PORT AND STBD SIDE FWD.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 13 January 1994 Resolved
TOP OFF FUEL TANKS IN ALL LIFEBOATS TO ENSURE 24 HOUR OPERATION.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Lifesaving
Issued 13 January 1994 Resolved
REPAIR WATER LIGHT IN THE PORT SIDE LIFEBOUY LOCATED ON MAIN DECK.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Fire Fighting
Issued 13 January 1994 Resolved
RESOLVE DISCREPANCIES ON FIRE CONTROL PLAN WITH REGARDS TO VENTILATION IAW SOLAS 48 CII REG. 44.
Condition: Unknown
Due 15 June 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 10 July 1986 Resolved
HYDROLIC ROOM DOOR ON DIONYSOS DECK-INSTALL SELF CLOSING DEVICE.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
REINSULATE MISSING SECTIONS OF INSULATION IN OVERHEAD AND BULKHEADS OF VENTILATION ROOM AND VENTILATION TRUK LOCATED AT FRAME 106 ON DIONYSOS DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
REINSULATE MVZ BULKHEAD AT FRAME 133 IN WAY OF PASSAGEWAY AND STAIR TOWER ON DIONYSOS DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
INSTALLL SELF CLOSING DEVICE ON DOOR TO VENTILATION ROOM #8 AND PROPERLY SEAL CABLE PENETRATION (DIONYSOS DECK).
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
ADJUST DOOR TO STAIR TOWER LOCATED NEAR CABIN SA5.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
REMOVE COMBUSTIBLE MATERIAL FROM PORT AND SBD ATWARTSHIP PASSAGEWAY ON POSEIDON DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
REMOVE PAINT FROM CARGO HOLD NO.I ON OCEANUS DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
INSTALL SELF CLOSING DEVICE IN DOOR IN VENTILATION ROOM NO.10 POSEIDON DECK
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Electrical
Issued 10 July 1986 Resolved
MAKE ELECTRICAL CABLE PENETRATION IN WATERTIGHT BULKHEAD IN WAY OF WATER- TIGHT DOOR NO.17 POSEIDON DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
INSTALL SELF CLOSING DEVICE ON DOOR FOR VENTILATION ROOM NO. 12 ON OCEANUS DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
INSTALL DRAUGHT STOPS IN OVERHEAD CEILINGS IN THE EL GRECO MAIN SALOON ON VENUS DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Electrical
Issued 10 July 1986 Resolved
PROVIDE AND/OR REPAIR EMERGENCY LIGHTING AT LANDINGS ON MAIN STAIRTOWER ON ALL DECKS AT FRAME 105.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
PROVIDE FORE CONTROL PLANS AT MAIN GANGWAY IN WATERTIGHT CONTAINER.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
VENTILATION ROOM #5 REINSULATE STBD BULKHEAD AND FILL CABLE PENETRATION AT FWD PORT CORNER ON DECK.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Fire Fighting
Issued 10 July 1986 Resolved
PROPERLY CLOSE ALL OPENINGS AROUND CABLE AND LIGHT FIXTURE PENETRATIONS IN ALL DRAFT STOPS ON POSEIDON AND NEREUS DECKS.
Condition: Unknown
Due 10 July 1986
Resolved 10 July 1986
Navigation
Issued 8 July 1986 Resolved
33 CFR 164.33 NOS CHARTS 18720 AND 18751 NOT ON BOARD. NOS COAST PILOT VOL.7 NOT ON BOARD. USCG LIGHT LIST VOL. VI NOT ON BOARD.
Condition: Unknown
Due 8 July 1986
Resolved 8 July 1986
Navigation
Issued 8 July 1986 Resolved
33 CFR 164.35(K) STEERING GEAR INSTRUCTIONS NOT POSTED ON BRIDGE.
Condition: Unknown
Due 8 July 1986
Resolved 8 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.