Records from 1984 to 1991. Most recent: inspection, 12 January 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
12 January 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 341235
12 January 1991
Certificate of Compliance
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 922871
29 January 1989
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 328177
29 January 1989
Certificate of Compliance
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1210764
1 August 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 468570
9 February 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 321930
9 February 1988
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1337582
6 November 1987
MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1329568
21 September 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 481598
12 August 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 517434
13 February 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 314298
13 February 1987
Certificate of Compliance
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1320925
7 September 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 507171
11 March 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 994208
10 March 1986
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 307440
26 October 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 489112
1 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 300620
1 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1288287
23 September 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 444029
Accommodation/Occupational Safety
Issued 12 January 1991
Resolved
VESSEL'S MARINE SANITATION DEVICE WAS NOT OPERABLE AS REQUIRED BY 33 CFR 159.7(1)
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 January 1991
Resolved
OIL TRANSFER PROCEDURES DID NOT SPECIFY DUTIES OF ALL CREW MEMBERS ON WATCH DURING AN OIL TRANSFER AS REQUIRED BY 33 CFR 155.750
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 12 January 1991
Resolved
VESSEL IS REQUIRED BY 33 CFR 155.360(A)(2) TO HAVE AN APPROVED AND OPERATIONAL 15 PPM OIL WATER SEPARATOR. VESSEL'S O/W SEPARATOR WAS DISCHARING ABOVE THE 15PPM LIMIT.
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 January 1991
Resolved
VESSEL DID NOT HAVE AN OIL POLLUTION PLACARD ON BOARD AS REQUIRED BY 33 CFR 155.450
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 12 January 1991
Resolved
PUMP ROOM BILGES HAD SIGNIFICANT AMOUNT OF OILY WASTE THAT WAS DETERMINED TO BE A HAZARDOUS CIRCUMSTANCE. CITE: 33 USC 1223(B)
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 12 January 1991
Resolved
A SIGNIFICANT NUMBER OF STEAMLINES ON THE MAIN DECK WERE OLD, LEAKING AND REQUIRED REPLACEMENT. IT WAS DETERMINED THAT A SERIOUS REPAIR PROBLEM EXISTED AND THAT THE VESSEL MAY BE UNSAFE. CITE: 33 CFR 160.113(A)
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 12 January 1991
Resolved
AIR CONDITIONER COOLING WATERLINE WAS CONNECTED TO THE FIREMAIN. 46CFR34.10-5(F) REQUIRES THAT NO BRANCH LINES SHALL BE CONNECTED TO THE FIRE MAINS FOR OTHER THAN FIRE, DECK WASH, OR TANK CLEANING PURPOSES.
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 12 January 1991
Resolved
VESSELS'S FIRE FIGHTING FOAM REQUIRES A TEST; HALON BOTTLES IN ENGINE RM REQUIRE A RECHARGE, AND THE VSL'S HALON SYSTEM NEEDS TO BE PROFESSIONALLY SERVICED. CITE: 46 CFR 31.10-18
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 12 January 1991
Resolved
VESSEL'S CARGO TANKS ARE WITHOUT AN INDIVIDUAL PRESSURE/VACUUM VALVE. ALL TANKSHIPS CONSTRUCTED AFTER 1JULY 1951 ARE REQUIRED BY 46CFR31.10-19(A)TO HAVE EACH CARGO TANK EQUIPPED WITH A VENT.
Condition: Unknown
Due 1 June 1991
Resolved 18 May 2002