Records from 1984 to 2008. Most recent: operational control imposed, 25 August 2008.
Inspection history · 82
24 August 2008
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3312398
22 August 2008
Deficiency Check · MARPOL Annex I Examination · PI Safety Exam · Ballast Water Examination · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3302576
21 August 2008
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3305187
20 August 2008
Type not recorded
No type recorded · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3304945
19 August 2008
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3303082
19 August 2008
STCW 95 Exam · ISPS I Exam · PI Safety Exam · ILO-147 Exam · MARPOL Annex I Examination · ISM Exam · COC-CVE Initial · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3304843
13 July 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · Damage Survey · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3265972
12 July 2008
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3275670
5 December 2007
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3110030
18 January 2006
ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2567641
12 February 2003
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1742831
11 March 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 645597
28 February 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 116582
20 February 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 400635
20 February 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1105356
4 February 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 400103
4 February 1997
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1097092
4 February 1997
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1359344
22 November 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 720267
20 November 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 397704
20 November 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1093146
10 November 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 397360
10 November 1996
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1377870
8 October 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 396243
22 September 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 207486
7 August 1996
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1448796
6 July 1996
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 393340
15 May 1996
Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1355842
11 February 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 387807
11 February 1996
Quarterly Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1187196
8 February 1996
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1184684
16 November 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 385151
16 November 1995
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1357377
30 March 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 108611
9 March 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 375840
9 March 1995
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850397
9 March 1995
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1430009
12 December 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 835904
20 November 1994
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 372609
20 November 1994
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1356906
10 March 1994
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354602
21 December 1993
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1379891
12 November 1993
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1455112
28 April 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1143852
23 March 1993
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1414122
22 January 1993
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831040
19 December 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1420682
21 February 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 951863
22 November 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1246951
24 August 1991
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 942071
25 May 1991
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 927898
2 March 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 342430
2 March 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908660
10 November 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 340499
10 November 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 899820
1 September 1990
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1217679
19 May 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1211196
24 February 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 335577
24 February 1990
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 901836
4 November 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 333725
4 November 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1005869
2 September 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1350814
3 June 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1045318
25 February 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1043239
26 November 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 895628
26 November 1988
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1205773
31 August 1988
Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195918
28 May 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1045360
22 May 1988
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1041068
13 February 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 321462
13 February 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1021339
28 November 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1031717
22 August 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1001733
23 May 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1336251
28 February 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1309668
29 November 1986
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1328756
23 August 1986
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1308573
24 May 1986
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307782
23 February 1986
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307365
16 November 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 306238
16 September 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1296170
12 November 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 298953
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 22 August 2008
No resolution recorded
PSCOs expanded exam based on incorrect entries in ORB, finding thick sludge in o/b discharge piping & valves from OWS. Samples taken. While demonstrating operation of OWS, crewmembers bypassed 15ppm sensor stating that is how they run the system. Calibration had not been done in months. Vsl is not allowed to use OWS for discharging until Class attests to integrity of system & calibration of sensor
Action required: 705 - Other - as specified
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 22 August 2008
Resolved
Excessive oil discovered throughout the engine room creating a serious fire hazard. Bilge & fuel oil purifier space also contain excessive amount of diesel fuel.
SOLAS 74 (2004 Consol. Edition) Ch. I / Reg. 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2008
Resolution: Vessel cleaned up most oil from engine room. Class will address excessive leaking from various pieces of equipment.
Communications › Alarms/Indicators › General Alarm
Issued 22 August 2008
No resolution recorded
Projector room on Deck 9 does not have General Alarm wired to space.
SOLAS 74 (unamended) Ch. II-2 / Reg. 29
To satisfaction of Class & Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Launching Appliances › Davit
Issued 22 August 2008
Resolved
All davit hook release wires are too short to properly launch the liferafts.
SOLAS 74 (unamended) Ch. III / Reg. 29
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2008
Resolution: All wires were corrected to adequate length.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 August 2008
Resolved
Several fire screen doors do not close properly preventing an adequate fire boundary. [D13,D14,M10,A18,B36,A19,P18,C5,A25]
SOLAS 74 (1992 Amendments) Ch. II-2 Reg. 41-2.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2008
Resolution: All noted FSDs were fixed to close properly.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 August 2008
Resolved
Lifeline attached to the starboard lifebuoy is deteriorated.
SOLAS 74 (2004 Consol. Ed.) Ch. III, Reg. 20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2008
Resolution: LIfeline replaced.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 22 August 2008
Resolved
Several lifeboats contain food rations where the vacuum seal has been compromised.
SOLAS 60, Ch. III Reg. 11(a)(xii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2008
Resolution: All food rations have been replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 August 2008
No resolution recorded
PSCOs found exposed wiring throughout the ship (Ex. passageway aft of WTD#8; radar room BR7; main laundry room; officer's messroom; pumproom #1, deck 2 - with 3-4" on deck)
SOLAS 60 Ch. II, Reg. 23(a)(ii)
To satisfaction of Class & Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Electrical › Lighting (service) › Lighting Fixture
Issued 22 August 2008
No resolution recorded
PSCOs found several light covers throughout the ship that were cracked or hanging loose.
SOLAS 60 Ch. II, Reg. 23(a)(ii)
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Lifeboat › Propulsion Starting System
Issued 22 August 2008
No resolution recorded
Hot start plug in the port side lifeboat is broken and wire tied to a deteriorated stanchion.
SOLAS 74 (2004 consol. Ed.) Ch. III Reg. 20.2
To satisfaction of Class & Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Pollution › Control of Garbage
Issued 22 August 2008
No resolution recorded
Garbage Mgmt Plan is not specific to the vessel & contains procedures that do not pertain to the vsl. They only separate food waste from "all other garbage". The "other" garbage is collected onboard & stored throughout the vsl in non-designated areas. Incinerator is inoperable with no plans to repair or replace. 5 offload receipts missing from July. (see Form B)
MARPOL 73/78, Annex V, Reg. 9
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 22 August 2008
Resolved
Fantail paint locker has a non-explosion proof light inside.
SOLAS 60, Ch. II, Reg. 45
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 August 2008
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 22 August 2008
No resolution recorded
PSCOs observed three deteriorating frames on aft bulkhead in Pump room 1, Deck 2
SOLAS 74 (2004 Consol. Ed.) Ch. I, Reg. 11
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Construction/Loadline › Structures › Manhole
Issued 22 August 2008
No resolution recorded
Hatch in engine room lower level starboard side aft is sagging.
SOLAS 74 (2004 Consol. Ed.) Ch. I, Reg. 11
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 22 August 2008
No resolution recorded
Fantail paint locker sprinkler system does not cover an adequate amount of the space.
SOLAS 74 (1992 Amendments) Ch. II-2 Reg. 41-2.5
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 August 2008
No resolution recorded
Rooms being used as storage rooms are not properly identified down the starboard corridor Deck 1 between frames A20-A25.
SOLAS 60, Ch. II, Reg. 45
To satisfaction of Class & Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 22 August 2008
No resolution recorded
Area forward of Bos'n store room is not approved for use as a storage room and should be labeled as such.
SOLAS 60, Ch. II, Reg. 45
To satisfaction of Class & Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Means of Escape › Escape Route Signs
Issued 22 August 2008
No resolution recorded
Several escape routes throughout ship are not marked (Ex. aft steering; laundry room D2)
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Stability › Watertight Integrity › Weathertight Enclosure
Issued 22 August 2008
No resolution recorded
Water was leaking in from the port light starboard outboard cabin 223.
SOLAS 74 (unamended) Ch. II, Reg. 14
To satisfaction of Class & Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 August 2008
No resolution recorded
Fire door zone release from bridge does not close water tight doors which are fire screen doors required to be remotely released.
SOLAS 74 (unamended) Ch. II, Reg. 37(f)
To satisfaction of Class & Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 22 August 2008
No resolution recorded
Hole in bulkhead - Deck 9, port side, frame 42 battery room - near upper area of WTD.
SOLAS 60, Ch. II, Reg. 12
To satisfaction of Class & Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Ventilation Systems › Operating Controls
Issued 22 August 2008
No resolution recorded
Many vents throughout vessel do not have any closure devices (Ex. CO2 room, deck 9, frame 40-50)
SOLAS 60 Ch. II, Reg. 47
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 22 August 2008
No resolution recorded
Many spaces have damage or missing structural fire protection. (Ex. C-deck, frame 127 stbd between Cat II stair & main laundry; C-deck frame 124 port between laundry & main lobby)
SOLAS 60, Ch. II, Reg. 36
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 22 August 2008
No resolution recorded
Many spaces on vessel are not properly categorized, missing insulation and do not contain required fire suppression. (see attached list for details)
SOLAS 60, Ch. II, Reg. 34
To satisfaction of Class
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Certificates/Documents › IOPP Certificate
Issued 22 August 2008
No resolution recorded
Vessel failed to comply with the requirements of their IOPP.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Pollution › Control of Discharge of Oil
Issued 22 August 2008
Resolved
Vessel operated the OWS in the EEZ of the United States in violation of the Clean Water Act.
Action required: 705 - Other - as specified
Resolved 24 August 2008
Operations/Management › Pollution › Report of Discharge
Issued 22 August 2008
Resolved
Vessel failed to report a discharge of oil into the navigable waterway of the U.S. while draining lifeboat bilges.
Action required: 705 - Other - as specified
Resolved 24 August 2008
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 22 August 2008
No resolution recorded
Company SMS requires OWS 15ppm sensor be calibrated annually. Sensor was never reported as calibrated to company.
SOLAS 74 (2004 Consol. Ed.) Ch. IX, Reg. 3.1 / ISM Code Reg. 10
To satisfaction of Flag Administration
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 22 August 2008
No resolution recorded
OWS is on critical equipment list. Oil content meter manual states that meter should be clean water calibrated using the process listed in Sect. 9.5 of instruction manual. The ship & company do not have any procedures to ensure this is happening. It is checked off as "tested weekly" on critical equipment list. SOLAS 74 (2004 Consol. Ed.) Ch. IX/3.1- ISM Code Reg.10. To satisfaction of Flag
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 22 August 2008
No resolution recorded
Vessel sent non-conformity to company reporting that incinerator was inoperative & excessive garbage was being stored onboard, creating a fire hazard. No objective evidence that company has properly responded to non-conformities submitted by vessel. SOLAS 74 (2004 Consol. Ed.) CH. IX/3.1 - ISM Code Reg. 9
To satifaction of Flag Administration
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Certificates/Documents › IOPP Certificate
Issued 22 August 2008
No resolution recorded
Vessel must obtain full term international certificates prior to returning to the U.S.
SOLAS 74 (2004 Consol. Ed.) Ch. I
To satisfaction of Flag Administration
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 22 August 2008
No resolution recorded
If vessel intends to carry U.S. passengers or embark passengers from a U.S. port, the vessel must complete the Initial Control Verification Exam including Marine Safety Center Plan review prior to returning to the United States.
To satisfaction of Coast Guard
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Lifesaving › Inflatable Liferafts › Inflation Characteristics
Issued 19 August 2008
Resolved
Code 0620: Required witness launching/ inflation of liferaft by crew members on next scheduled exam.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 24 August 2008
Resolution: Witnessed launching of two liferafts in Seward, AK.
Documentation › Certificates/Documents › Control Verification for Foreign Vessel (CG4504)
Issued 19 August 2008
Resolved
Code: 0112 Vessel must enroll to ICVE program submitting request to MSC prior to return to US waters after sailing foreign from Seward, Alaska 22 August 2008.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 August 2008
Resolved
CODE: 0660 Retro-reflective tape & condition of lifejackets found worn out during this boarding inspection. Check all lifejackets for compliance with SOLAS.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 24 August 2008
Resolution: Lifejackets replaced or repaired.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 19 August 2008
Resolved
CODE: 0199 Found during the inspection the vessel current ballast water plan not approved by either flag state or class. Vessel found not complying with the compulsory ballast water reporting. Master [name withheld] educated & given CG pamphlets’ into Ballast [name withheld] reporting program.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Structural - Horizontal Zones › General
Issued 19 August 2008
Resolved
CODE: 0750 Water Tight Doors & Fire Screen Doors must be check & tested to CG Inspector discretion on next exam for proper assurance of all WTD & FSD are maintained to standards for safety. There was doubt during this inspection that proper test & maintenance not being kept up by crew due to age of vessel. Most check & tested during this inspection.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 24 August 2008
Resolution: ALL WTDs & FSDs were checked and repaired during the exam in Seward, AK.
Engineering › Freshwater Generation System › Pump
Issued 19 August 2008
Resolved
CODE: 0499 Reverse Osmosis system (Freshwater Distiller) non operational during this inspection. RO to be fully operational prior to sailing foreign (Yokohama, Japan) after Seward, Alaska 22 August 2008.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 24 August 2008
Resolution: System was repaired prior to completing the exam in Seward, AK.
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 19 August 2008
Resolved
CODE: 2545 Non-conformity for incinerator out of commission cannot be found & company waste management plans were not available or non-existent during this inspection. Vessel' housekeeping & garbage were found to be very excessive in all areas during this boarding. Required proper housekeeping rules & discharge/tracking of garbage by Environmental Officer.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 24 August 2008
Resolution: Issues were readdressed separately on Form B issued in Seward, AK
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 19 August 2008
Resolved
CODE:2110 Vessel oily waste holding tanks almost full. Oily bilge water in (3) holding tanks must be discharge properly to shore facilities in Seward, Alaska prior sailing foreign to Yokohama, Japan. Ensure enough space available to hold oily. OWS check & tested during this inspection. Due to excessive fuel/ oil leaks (identified & repaired), this requirement issued to vessel prior going foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 September 2008
Resolved 24 August 2008
Resolution: Oily waste was discharged ashore in Seward, AK
Construction/Loadline › Structures › Deck Plating
Issued 19 August 2008
Resolved
WORKLIST ITEM #1- Repair/replace all wasted deck plating in pump room #2.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 August 2008
Resolved
WORKLIST ITEM #2 - Close junction box for bilge float located in pumproom #2, stbd side aft (exposed electrical wires).
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 August 2008
Resolved
WORKLIST ITEM #3 - Secure for sea all scrap metal and parts in pump-room #2.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 19 August 2008
Resolved
WORKLIST ITEM #4 - Remove 21 (5 Gallon) jugs of Air Compressor Oil from longitudinals on stbd side of pump-room #3 and stow in designated storage area.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 August 2008
Resolved
WORKLIST ITEM #5 - Close junction box for bilge float loacted in pump-room #3, port side, aft. (bare wires exposed).
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 August 2008
Resolved
WORKLIST ITEM #6 - Remove garbage and scrap metal from port side, fwd, enginer room in way of sea water suction skin valve.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 19 August 2008
Resolved
WORKLIST ITEM #7 - Ship's service diesel generator #2 has excessive fuel oil leaks from unknown source. Repair leaks and clean standing fuel oil.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Engineering › Diesel Engine (auxiliary) › Injector (fuel injection)
Issued 19 August 2008
Resolved
WORKLIST ITEM #8 - Ship's service diesel generator #7 has excessive fuel oil leaks from unknown source. Repair leaks and clean standing fuel oil.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 19 August 2008
Resolved
WORKLIST ITEM #9 - #3 Main Engine govenor is leaks lube oil. Repair leak and clean all standing oil.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Engineering › Diesel Engine (propulsion-reduction gear) › Pump, High Pressure (fuel injection)
Issued 19 August 2008
Resolved
WORKLIST ITEM # 10 - Replace all damaged spray shielding on fuel oil lines leading to and from high pressure fuel pump for #1, 2, 3 and 4 Main engines.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 19 August 2008
Resolved
WORKLIST ITEM #11 - Steering rudder angle indicator on bridge off 4 degrees during emergency steering test. Make necessary adjustments/repairs.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 19 August 2008
Resolved
WORKLIST ITEM #12 - Replace all low level, photoluminescent lighting on out board side of all main corridor stairways.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Electrical › Electrical Distribution System (service) › Panelboard
Issued 19 August 2008
Resolved
WORKLIST ITEM #13 - Close open holes on cover for load control system (Rolls Royce).
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Combustible Materials › Insulation
Issued 19 August 2008
Resolved
WORKLIST ITEM #14 - Replace A-60 insulation on stbd side of main engine room in way of workshop.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 19 August 2008
Resolved
WORKLIST ITEM #15 - Found numerous cans of paint on stbd side of A/C room. Remove and stoe paint in designated paint locker.
Action required: 705 - Other - as specified
Resolved 9 June 2015
Resolution: vessel no longer in service
Accommodation/Occupational Safety › Ventilation › General
Issued 19 August 2008
Resolved
WORKLIST ITEM #16 - Repair damaged/cut ventilation duct located in stbd main engine room.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Combustible Materials › Ceilings
Issued 19 August 2008
Resolved
WORKLIST ITEM #17 - Excessive amounts of soot found on main engine upper exhausts and overheads. Remove soot and clean area.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 19 August 2008
Resolved
WORKLSIT ITEM #18 - Incorrect stowage bracket for portable CO2 extinguisher (E Deck 12, CO2 6). Install correct mounting bracket.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Stability › Watertight Integrity › General
Issued 19 August 2008
Resolved
WORKLIST ITEMS #19 - Wire run through blkhd leading to voltage regulator for auxiliary genertor room (inboard side) not sealed properly.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Combustible Materials › Insulation
Issued 19 August 2008
Resolved
WORKLIST ITEM #20 - Install A-60 insulation in main engine cylinder head workshop, inboard side, upper blkhd.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Combustible Materials › Insulation
Issued 19 August 2008
Resolved
WORKLIST ITEM #21 - Install A-60 insulation in fwd, port side main engine room work shop.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 August 2008
Resolved
WORKLIST ITEM # 22 - Repair cover located on deck, port side, upper, fwd work shop of main engine room. Cover is bent up posing a tripping hazard.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Nozzles › Condition
Issued 19 August 2008
Resolved
WORKLIST ITEM #23 - Portable fire extinguisher (P9 E Deck 2-6) has broken nozzle. Replace/repair nozzle.
Due 3 September 2008
Resolved 20 August 2008
Resolution: 1st engineer replaced nozzle.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 19 August 2008
Resolved
WORKLIST ITEM #24 - Missing valve handle on numerous valve throughout all engineering spaces. Install valve handles as needed.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Fire Fighting › Means of Escape › Doorways
Issued 19 August 2008
Resolved
WORKLIST ITEM #25 - Escape door D15 in main engine room does not close properly. Make adjustments as necessary.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 August 2008
Resolved
WORKLIST ITEM #27 - Continue house keeping thoughout all engineering spaces.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 August 2008
Resolved
WORKLIST ITEM #28 - Continue tieing up/securing for sea all loose gear in all machinery spaces.
Action required: 705 - Other - as specified
Resolved 9 June 2015
Resolution: vessel no longer in service
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 19 August 2008
Resolved
WORKLIST ITEM #29 - Contiune to limit the amount of lube oil drums (55 gal) in all machinery spaces.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Accommodation/Occupational Safety › Heating › Piping
Issued 19 August 2008
Resolved
WORKLIST ITEM #30 - Continue to eliminate small water leaks and steam leaks in machinery spaces.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 19 August 2008
Resolved
WORKLIST ITEM #31 - Gusset connected to port, aft bulkhead of pump room #3, the hull and the first horizontal frame aft of the aft bulkhead was found severely fractured in 2 locations. Make repairs tot he satisfaction of class.
Action required: 705 - Other - as specified
Resolved 2 June 2015
Resolution: vessel no longer in service
Stability › Watertight Integrity › General
Issued 17 July 2008
Resolved
Indicator lights on watertight door panel located on bridge are too dim and difficult to discern if the door is open or closed. Improve intensity of lights to the satisfaction of class. SOLAS 60/II Reg 13.
Action required: 705 - Other - as specified
Due 17 August 2008
Resolved 24 August 2008
Resolution: LED lights on bridge have been replaced.
Stability › Watertight Integrity › General
Issued 17 July 2008
No resolution recorded
All watertight doors must remain closed while vessel is underway until Flag Administration provides an exemption letter to change this condition. SOLAS 60/II Reg 13
Action required: 705 - Other - as specified
Due 17 August 2008 — due date passed with no resolution recorded
Fire Fighting › Means of Escape › Emergency Lighting
Issued 17 July 2008
No resolution recorded
Provide documentary evidence of last test of photoluminescent strips to the satisfaction of class. SOLAS 74 (92 Amendments) II-2/41-2 Reg 4.7 & IMO Resolution A.752(18)
Action required: 705 - Other - as specified
Due 17 August 2008 — due date passed with no resolution recorded
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 July 2008
No resolution recorded
The vsl’s fire control plan is not up to date, the escape routes are not clear. A reception area on the FCP is a cabin and has direct access to a stairway. There are numerous spaces that are being utilized for other than what the FCP indicates and these spaces require a higher level of structural fire protection, evacuation routes are not clear and there are signs that direct people to dead end.
Action required: 705 - Other - as specified
Due 13 January 2009 — due date passed with no resolution recorded
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 15 July 2008
Resolved
There are leather couches that are made of combustible material in all of the stairways. Furniture in stairways shall be of restricted fire risk in accordance with SOLAS 74 (92 Amendments) II-2/41-2
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2008
Resolved 15 July 2008
Resolution: All couches removed while onboard.
Construction/Loadline › Hull › Hull Plating
Issued 15 July 2008
Resolved
Vessel has reported a hole in the hull in way of frame A-0 port side and there is additional evidence of hull degradation in isolated areas on the port and starboard side. Provide a written damage report, details of any temporary repairs and a repair proposal reviewed and approved by your Flag Administration. ILCC 66/Article 15
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2008
Resolved 17 July 2008
Resolution: Class Bureau Veritas issued condition for one-way route to Tampa to effect repairs Sector St. Petersburg informed.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 15 July 2008
Resolved
During the Port State Control examination, over 60 items have been identified as not meeting the applicable SOLAS regulations. These items have been provided to you and attached to this Port State Control Form “B”. All items must be addressed prior to the vessel’s departure from port. SOLAS XI-1/Regulation 4.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 July 2008
Resolved 17 July 2008
Resolution: All work-list items were cleared or addressed by Class.
Unknown
Issued 4 February 1997
Resolved
REPAIR OR REPLACE LINE-THROWING APPARATUS.
Condition: Unknown
Due 4 February 1997
Resolved 4 February 1997
Engineering
Issued 10 November 1996
Resolved
HEAVY FUEL VALVE IS LEAKING. MUST BE REPLACED/RENEW PRIOR TO 17NOV96
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 10 November 1996
Resolved
REPLACE SIGNALING MIRROR ON STARBOARD SIDE TENDER AS PER SOLAS 74 CH III REG 8.17.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Engineering
Issued 10 November 1996
Resolved
Make permanent repairs to leaking heavy fuel valve feeding heavy fuel tank.
Condition: Unknown
Due 10 November 1996
Resolved 10 November 1996
Lifesaving
Issued 10 November 1996
Resolved
Replace starboard side tender (#4 boat) signaling mirror.
Condition: Unknown
Due 10 November 1996
Resolved 10 November 1996
Documentation
Issued 6 July 1996
Resolved
VSL SOPEP not reviewed annually since submission in 1994. Also, paragraph 4.1.4 incorrectly identifies overflow tank connections to tank vents. Tanks on vsl vent directly to the side of the vsl with no intervening overflow system.
Condition: Unknown
Due 16 August 1996
Resolved 16 August 1996
Documentation
Issued 6 July 1996
Resolved
Automatic and non-automatic disposals of bilge water to tank 27s/b not logged.
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Documentation
Issued 6 July 1996
Resolved
Sludge tank transfers from 12s/b offloaded to Vancouver not logged in Oil record Book.
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Documentation
Issued 6 July 1996
Resolved
No soundings of sludge tanks logged (on short voyages should be weekly).
Condition: Unknown
Due 17 July 1996
Resolved 17 July 1996
Deck/Cargo
Issued 6 July 1996
Resolved
VSL has direct piping connecting a sludge tank overboard.
Condition: Unknown
Due 16 August 1996
Resolved 16 August 1996
Documentation
Issued 6 July 1996
Resolved
Oil residue tanks 11S/B, 12 S/B, and 13S/b not idewntified on IOPP form A.
Condition: Unknown
Due 9 October 1996
Resolved 9 October 1996
Lifesaving
Issued 16 November 1995
Resolved
OBTAIN AND INSTALL NEW PFD LIGHTS AT THE VESSEL'S NEXT U.S. PORT.
Condition: Unknown
Due 16 November 1995
Resolved 16 November 1995
Lifesaving
Issued 12 December 1994
Resolved
REPAIR OR REPLACE WORN WHEELS ON #4 PORT AND #1 STBD LIFEBOAT DAVITS TO SATISFACTION OF CLASS SOCIETY DURING NEXT DRYDOCK.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Lifesaving
Issued 20 November 1994
Resolved
REMOVE EXCESSIVE OIL FROM BILGES AND REPAIR LEAKS IN MAIN DIESEL ENGINES TOPREVENT RECURRANCE._x001C_
Condition: Unknown
Due 13 December 1994
Resolved 14 December 1994
Lifesaving
Issued 20 November 1994
Resolved
REPAIR OR REPLACE WORN WHEELS ON #4 LIFEBOAT DAVITS AS REQUIRED._x001C_
Condition: Unknown
Due 13 December 1994
Resolved 14 December 1994
Fire Fighting
Issued 23 March 1993
Resolved
Class or flag state to check and verify all fire doors for proper_x001C_ operation and provide report to USCG.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Lifesaving
Issued 22 January 1993
Resolved
Remove portable lockers located in forward stair tower on decks A and C.
Condition: Unknown
Due 22 January 1993
Resolved 22 January 1993
Fire Fighting
Issued 19 December 1992
Resolved
Remove all mechinical holdbacks on fire doors.
Condition: Unknown
Due 22 January 1993
Resolved 22 January 1993
Fire Fighting
Issued 19 December 1992
Resolved
Prove proper operation of all fire doors._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Lifesaving
Issued 24 August 1991
Resolved
THE HYDRO RELAESE ON LIFERAFTS 11E AND 12E INPROPERLY INSTALLED.
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Lifesaving
Issued 24 August 1991
Resolved
SMOKE DISTRESS SMOKE OUTDATED.
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Fire Fighting
Issued 24 August 1991
Resolved
FIRE STATION #37 CONCEALED BEHIND FUNITURE AND POORLY MARKED.
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Fire Fighting
Issued 24 August 1991
Resolved
FIREMANS OUTFIT LIFELINE WORN AND FRAYED. LINE TO BE REPLACED.
Condition: Unknown
Due 24 August 1991
Resolved 24 August 1991
Accommodation/Occupational Safety
Issued 10 November 1990
Resolved
PROVIDE PASSENGER SAFETY ILLUSTRATIONS AND INSTRUCTIONS IN APPROPRIATE LANGUAGES AND POST IN PASSENGER CORRIDORS AND AT MUSTER STATIONS. SOLAS III/9.2
Condition: Unknown
Due 10 November 1990
Resolved 10 November 1990
Engineering
Issued 10 November 1990
Resolved
REPAIR OILY WATER SEPERATOR EQUIPMENT REQUIRED BY YOUR INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE AND PROVE PROPER OPERATION OF THE SYSTEM, ALARM, AND AUTOMATIC STOPPING DEVICE.
Condition: Unknown
Due 10 November 1990
Resolved 10 November 1990
Fire Fighting
Issued 10 November 1990
Resolved
PROVIDE FIRE EXTINGUISHER SERVICING CERTIFICATES OF ALL PORTABLE AND FIXED SYSTEMS TO DOCUMENT THE REQUIRED ANNUAL SERVICING OF THESE SYSTEMS.
Condition: Unknown
Due 10 November 1990
Resolved 10 November 1990
Lifesaving
Issued 10 November 1990
Resolved
PROVIDE AND POST ENGINE STARTING INSTRUCTIONS IN ALL LIFE BOATS IN ACCORDANCE WITH SOLAS REGULATION III/9.2.1
Condition: Unknown
Due 10 November 1990
Resolved 10 November 1990
Lifesaving
Issued 1 September 1990
Resolved
MUSTER LISTS COMPLYING WITH THE REQUIREMENTS OF REGULATION 53 SHALL BE EXHIBITED IN CONSPICUOUS PLACES THROUGHOUT THE SHIP INCLUDING THE NAVIGATING BRIDGE, ENGINE ROOM AND CREW ACCOMDATION SPACES. SOLAS REGULATION 8 (3)
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Navigation
Issued 1 September 1990
Resolved
PROVIDE SUITABLE ARRANGEMENTS TO ENSURE WORKING ACCESS TO STEERING GEAR MACHINERY AND CONTROLS. THESE ARRANGEMENTS SHALL INCLUDE HANDRAILS AND GRATINGS OR OTHER NONSLIP SURFACES TO ENSURE SUITABLE WORKING CONDITIONS INTHE EVENT OF HYDRAULIC FLUID LEAKAGE.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Documentation
Issued 1 September 1990
Resolved
PROVIDE AND POST AT LEAST FIVE MARPOL V PLACARDS. ONE IN GALLEY, ONE ON BRIDGE, LOUNGES, AND INCINERATOR.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Lifesaving
Issued 1 September 1990
Resolved
REPAIR EMERGENCY LIGHT FOR STARBOARD LIFEBOAT AND LIFERAFT LOCATED NEAR FIRE STATION #135. LIGHT IS HANGING LOOSE FROM MAIN BRACKET.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Lifesaving
Issued 1 September 1990
Resolved
ILLUSTRATIONS AND INSTRUCTIONS IN APPROPRIATE LANGUAGES SHALL BE POSTED IN PASSENGER CABINS AND BE CONSPICUOUSLY DISPLAYED AT MUSTER STATIONS AND OTHER PASSENGER SPACES TO INFORM PASSENGERS OF: THEIR STATION, THE ESSENTIAL ACTIONS DURING EMERGENCY, THE METHOD OF DONNING LIFEJACKETS.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Lifesaving
Issued 1 September 1990
Resolved
POSTERS AND SIGNS SHALL BE PROVIDED ON OR IN THE VICINITY OF SURVIVAL CRAFTAND THEIR LAUNCHING CONTROLS AND SHALL: ILLUSTRATE THE PURPOSE OF CONTROLS AND THE PROCEDURES FOR OPERATING THE APPLIANCE AND GIVE INSTRUCTIONS OR WARNINGS. SOLAS REGULATION 9 (2.1-3)
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Engineering
Issued 1 September 1990
Resolved
REPAIR OWS 15PPM ALARM AND PROVE OPERATION OF OWS, ALARM, AND AUTOMATIC STOPPING DEVICE.
Condition: Unknown
Due 1 September 1990
Resolved 1 September 1990
Lifesaving
Issued 19 May 1990
Resolved
CONDUCT SATISFACTORY INFLATABLE LIFERAFT DRILL BY DEPLOYING A RAFT AND MAKING IT READY FOR EMBARKATION.
Condition: Unknown
Due 19 May 1990
Resolved 19 May 1990