MAURY USCG vessel records Sign in
← All vessels

PUPPY P

PUPPY P is a 1970 tank ship. The Coast Guard has recorded 3 inspections since 1984, most recently in December 1985, along with 8 deficiencies.

Records from 1984 to 1985. Most recent: inspection, 17 December 1985.

Built
1970
Last inspected
17 December 1985
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7006247 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
221860
Flag
MALTA
—
Maury page id
psix-221860

Inspections, by type

…with no type recorded3
Years with a record 2 calendar years (1984–1985)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 41 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12018 - Regulatory (Subpart C or D), Net Ton
17485 - Regulatory (Subpart C or D), Gross Ton
30228 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

17 December 1985 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 305930
11 April 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 464841
1 August 1984 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 297261

Deficiency record · 8

Documentation
Issued 17 December 1985 Resolved
VESSELS CARGO AND BUNKER OIL TRANSFER PROCEDURES WERE INCOMPLETE AND NOT INTHE ORDER LISTED OR CROSS REFERENCED AS REQUIRED BY 33CFR155.750. AMENDMENTREQUIRED PRIOR TO NEXT US PORT.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 17 December 1985 Resolved
VESSEL DID NOT HAVE POSTED ON THE BRIDGE THE DIAGRAM AND INSTRUCTIONS FOR THE CHANGEOVER TO THE REMOTE STEERING GEAR POWER AND CONTROL SYSTEM AS REQUIRED BY 33CFR164.35(K).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 17 December 1985 Resolved
VESSEL DID NOT HAVE POSTED ON THE WEATHER DECK A DUPLICATE SET OF FIRE CONTROL PLANS AS REQUIRED BY SOLAS CHAPTER II-2 REG. 20-2(1981 AMENDED).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 17 December 1985 Resolved
RENEW THE WASTED CARGO TANK STEAM HEATING COIL LINES OR BLANK OFF AT THE FIRST FLANGE CONNECTION EXITING THE TANK OR INSTALL HANDWHEELS ON THE CONTROL VALVES EXITING THE TANKS OR OTHER MEASURES ACCEPTABLE TO THE HOME ADMINISTRATION. PROVIDE DOCUMENTATION OF ACCEPTANCE. (ALL TANKS AFFECTED)
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 17 December 1985 Resolved
RENEW THE BROKEN STUDS ON THE BUTTERWORTH OPENINGS OF THE CARGO TANKS AT THE NEXT GAS FREEING. (NUMEROUS TANKS AFFECTED- 1-3 STUDS- NO LEAKAGE)
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 17 December 1985 Resolved
RENEW PORT AND STBD BUNKER TANK VENT FLAME SCREENS.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 17 December 1985 Resolved
MAKE PERMANENT REPAIRS TO PORT AND STBD BUNKER TANK VENTS POLLUTION CONTAINMENT.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 17 December 1985 Resolved
RENEW ALL CARGO TANK ULLAGE FLAME SCREENS TO ATTAIN AN EFFECTIVE SEAL.(SLOTCUT IN OUTER RINGS)
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.