MAURY USCG vessel records Sign in
← All vessels

ATLANTIC TRADER

ATLANTIC TRADER is a 1969 freight ship. The Coast Guard has recorded 28 inspections since 1986, most recently in February 2024, along with 42 deficiencies and 3 operational controls.

Records from 1986 to 2024. Most recent: inspection, 28 February 2024.

Built
1969
Last inspected
28 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7007447 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
221876
Flag
PANAMA
—
Maury page id
psix-221876

Inspections, by type

…with no type recorded26
Years with a record 13 calendar years (1986–2024)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1050 - Regulatory (Subpart C or D), Net Ton
713 - Convention (Subpart B), Net Ton
2539 - Dead Weight, Ton
1585 - Regulatory (Subpart C or D), Gross Ton
1739 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

28 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7871751
15 February 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 412616
7 May 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 403396
21 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 651821
15 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 651822
13 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 396163
6 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 151626
7 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 454149
7 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 533413
26 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387605
19 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387074
19 September 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382842
2 December 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 372961
2 December 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 870594
16 September 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 370606
15 September 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 869302
3 August 1993 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 360486
8 May 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 19020
5 June 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351429
1 October 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 346245
2 April 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 342922
15 March 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 336255
21 April 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 322962
6 December 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 320048
1 May 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 316421
27 October 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 312240
19 March 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 446082
5 January 1986 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 306236

Deficiency record · 42

Lifesaving
Issued 15 February 1998 Resolved
Immediately commence logging of monthly inspection of all life-saving appliances including examination of rescueboat equipment in accordance withSOLAS 74 (amended), Chapter III, Reg. 19.7.
Condition: Unknown
Due 16 February 1998
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1998 from activity: 412616. Inactivated vessel due to no activity for 26 years.
Lifesaving
Issued 15 February 1998 Resolved
Immediately commence weekly logging of operational test of rescueboat engine in accordance with SOLAS 74 (amended), Chapter III, Reg. 19.6.2.
Condition: Unknown
Due 16 February 1998
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1998 from activity: 412616. Inactivated vessel due to no activity for 26 years.
Lifesaving
Issued 15 February 1998 Resolved
Immediately commence weekly logging of general alarm test in accordance with SOLAS 74 (amended), Chapter III, Reg. 19.6.3.
Condition: Unknown
Due 16 February 1998
Resolved 28 February 2024
Resolution: 28FEB2024: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List. No activities since 1998 from activity: 412616. Inactivated vessel due to no activity for 26 years.
Accommodation/Occupational Safety
Issued 7 May 1997 Resolved
RE-INSTALL LADDER IN VIC OF EMERGENCY ESCAPE HATCH IN STEERING GEAR ROOM.
Condition: Unknown
Due 5 June 1997
Resolved 8 May 1997
Engineering
Issued 7 May 1997 Resolved
PROVE PROPER OPERATION OF REMOTE FUEL SHUT-OFF VALVES IN THE PRESENCE OF CLASS SURVEYOR. PROVIDE REPORT OF OPERATION TO USCG.
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Engineering
Issued 7 May 1997 Resolved
ELIMINATE RUBBER HOSE CROSS CONNECTION FOR SLOP TANK (DIRECTLY FROM OWS TO SLOP TO OVERBOARD).
Condition: Unknown
Due 7 May 1997
Resolved 8 May 1997
Documentation
Issued 7 May 1997 Resolved
PROVIDE PROPER ENTRIES IN OIL RECORD BOOK.
Condition: Unknown
Due 15 February 1998
Resolved 15 February 1998
Documentation
Issued 7 May 1997 Resolved
PROVIDE FORM A SUPPLEMENT TO IOPP CERTIFICATE.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Engineering
Issued 7 May 1997 Resolved
PROVE PROPER OPERATION OF OIL WATER SEPARATOR TO CLASS SURVEYOR AND USCG. HAVE CLASS SURVEYOR PROVIDE REPORT OF OPERATION TO USCG PRIOR TO USCG INSPECTION.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Construction/Loadline
Issued 13 October 1996 Resolved
PROVIDE COMPLETE LOADLINE SURVEY FROM CLASS, ADDRESS STRUCTURAL/WATERTIGHT INTEGRITY.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Documentation
Issued 13 October 1996 Resolved
PROVIDE A $10,000.00 LETTER OF UNDERTAKING TO MSO MIAMI COTP PRIOR TO VESSEL'S DEPARTURE FROM MSO MIAMI COTP ZONE.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Construction/Loadline
Issued 13 October 1996 Resolved
PROVIDE ULTRASOUND TESTING OF TANK TOPS, HULL, AND FUELING SYSTEM.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Engineering
Issued 13 October 1996 Resolved
PROVIDE STATEMENT FROM CLASS ATTESTING TO FUEL SYSTEM INTEGRITY.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Deck/Cargo
Issued 13 October 1996 Resolved
OFF LOAD ALL CONTAINERS/CARGO PRIOR TO SURVEY.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Documentation
Issued 13 October 1996 Resolved
PROVIDE CREW MEDICAL CERTIFICATES._x001C_
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Construction/Loadline
Issued 13 October 1996 Resolved
PROVIDE DOCUMENTATION FROM FLAG/CLASS ATTESTING TO MATERIAL CONDITION OF VESSEL'S HULL, INCLUDING SIDESHELL, TANK TOPS, AND VENT LINES.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Engineering
Issued 13 October 1996 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Engineering
Issued 13 October 1996 Resolved
PROVIDE A MARPOL STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Fire Fighting
Issued 13 October 1996 Resolved
PROVIDE ADDITIONAL SCBA FOR A TOTAL OF 2 SCBA'S.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Documentation
Issued 13 October 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Fire Fighting
Issued 13 October 1996 Resolved
PROVIDE AN INSTRUCTION MANUAL FOR FIRE PROTECTION EQUIPMENT.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Lifesaving
Issued 13 October 1996 Resolved
PROVIDE A MAINTENANCE MANUAL FOR ALL LIFE SAVING APPLIANCES.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Lifesaving
Issued 13 October 1996 Resolved
PROVIDE A CREW TRAINING MANUAL SPECIFIC TO THE SHIP.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Engineering
Issued 13 October 1996 Resolved
PROVIDE A LINE DIAGRAM FOR OIL TRANSFER PROCEDURES AND POST AT BUNKER STATION.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Documentation
Issued 19 January 1996 Resolved
Provide documentation from class society that inspection was conducted on double bottom ballast tanks and piping and that proper repairs were completed. To be done prior to the loading of the vessel.
Condition: Unknown
Due 5 February 1996
Resolved 5 February 1996
Deck/Cargo
Issued 19 September 1995 Resolved
PROVIDE MACHINERY GUARDS FOR ROTATING MACHINERY (SPECIFICALLY, EMERGENCY GENERATOR IN FORWARD MACHINERY SPACE)
Condition: Unknown
Due 19 October 1995
Resolved 21 September 1995
Fire Fighting
Issued 19 September 1995 Resolved
CROP AND RENEW TWO LEAKING SECTIONS OF THE FIRE MAIN ON STARBOARD SIDE OF MAIN DECK.
Condition: Unknown
Due 5 November 1995
Resolved 6 November 1995
Navigation
Issued 19 September 1995 Resolved
PROVIDE CURRENT COPIES OF LIGHT LIST, COAST PILOT; UPDATE COPIES OF LOCAL CHARTS I.A.W. MOST RECENT NOTICE TO MARINERS
Condition: Unknown
Due 5 November 1995
Resolved 6 November 1995
Documentation
Issued 19 September 1995 Resolved
PROVIDE VALID COFR CERTIFICATE.
Condition: Unknown
Due 19 September 1995
Resolved 21 September 1995
Lifesaving
Issued 19 September 1995 Resolved
REPAINT LOADLINE MARK IN CONTRASTING COLOR TO HULL.
Condition: Unknown
Due 19 October 1995
Resolved 21 September 1995
Documentation
Issued 19 September 1995 Resolved
ENSURE LOADLINE MARKING AND LOADLINE CERTIFICATE CORRESPOND.
Condition: Unknown
Due 19 September 1995
Resolved 21 September 1995
Engineering
Issued 19 September 1995 Resolved
AMEND OIL TRANSFER PROCEDURES AS PER 33 CFR 155.750 PRIOR TO NEXT BUNKERINGIN U.S. WATERS.
Condition: Unknown
Due 19 September 1995
Resolved 20 September 1995
Documentation
Issued 19 September 1995 Resolved
PROVIDE MOST RECENT VESSEL LOGBOOK PROVIDING PROOF OF ABANDON-SHIP, FIRE, OIL POLLUTION DRILLS DURING MONTHS OF JUN-AUG 95.
Condition: Unknown
Due 19 September 1995
Resolved 21 September 1995
Engineering
Issued 19 September 1995 Resolved
PROVE PROPER OPERATION (SENSOR AND ALARM) OF 15 PPM OILY WATER SEPARATOR.
Condition: Unknown
Due 19 September 1995
Resolved 21 September 1995
Fire Fighting
Issued 19 September 1995 Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP.
Condition: Unknown
Due 5 November 1995
Resolved 6 November 1995
Electrical
Issued 19 September 1995 Resolved
PROVIDE COVERS FOR ALL BARE BULBS IN FORWARD MACHINERY SPACE.
Condition: Unknown
Due 13 October 1996
Resolved 13 October 1996
Documentation
Issued 16 September 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 December 1994
Resolved 3 December 1994
Documentation
Issued 2 April 1991 Resolved
VESSEL IN VIOLATION OF 33CFR155.750III BECAUSE DID NOT HAVE A PROCEDURE_x001C_ FOR EMPTYING MANIFOLD CONTAINMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 October 1991
Resolved 3 October 1991
Documentation
Issued 6 December 1987 Resolved
VESSELS SAFETY CONTRUCTION CERTIFICATE EXPIRED.
Condition: Unknown
Due 6 December 1987
Resolved 6 December 1987
Documentation
Issued 6 December 1987 Resolved
VESSELS SAFETY EQUIPMENT CERTIFICATE EXPIRED.
Condition: Unknown
Due 6 December 1987
Resolved 6 December 1987
Documentation
Issued 1 May 1987 Resolved
VESSEL OIL RECORD BOOK DID NOT HAVE ANY ENTRIES.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987
Navigation
Issued 1 May 1987 Resolved
VESSEL DID NOT HAVE COPY OF INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 1 May 1987
Resolved 1 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.