Records from 1984 to 2003. Most recent: inspection, 7 December 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 61
7 December 2003
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1961879
6 December 2003
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1959779
27 May 2003
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1788243
11 August 2002
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1660003
27 June 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1637809
5 June 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1626535
22 May 2002
Security Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1619598
12 May 2002
Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1615721
5 August 2001
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1070288
24 June 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1068657
6 May 2001
Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1453889
6 August 2000
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1373120
7 May 2000
Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1446923
15 December 1996
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1367993
21 March 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 389068
21 March 1996
Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1467463
22 December 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 385308
22 December 1995
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1394436
9 March 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 376098
9 March 1995
Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1357048
13 November 1993
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1397980
30 January 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 356071
30 January 1993
MARPOL Annex V Examination · Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 828802
13 November 1992
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 680859
16 October 1992
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 353818
16 October 1992
Control Verification · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1245736
11 June 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 680860
7 June 1992
Certificate of Compliance · Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1410734
24 May 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 457451
7 May 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 948371
20 December 1991
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 958963
8 September 1991
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1314313
1 June 1991
Certificate of Compliance
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1257072
17 April 1991
Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 921362
10 January 1991
Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909273
2 January 1991
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 347993
11 October 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 339801
11 October 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1241560
9 July 1990
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1220400
7 April 1990
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1219994
5 January 1990
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1238620
13 October 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1343381
14 June 1989
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1043486
4 March 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 491333
4 March 1989
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1197410
2 December 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 327186
2 December 1988
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 895979
19 March 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 180307
24 February 1988
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1042271
21 November 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1334642
7 February 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 314189
1 November 1986
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1320619
21 September 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 520451
19 June 1986
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1301274
15 May 1986
Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 998484
11 February 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 473351
20 December 1985
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 990739
29 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 299739
29 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1284773
26 June 1984
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 296824
14 June 1984
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 296684
Lifesaving › Lifeboat Equipment › Food Ration
Issued 27 May 2003
Resolved
Replace food ration biscuits which have lost their vacuum pack.
Due 29 May 2003
Resolved 29 May 2003
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 27 May 2003
Resolved
Replace approx. 75 expired lifejacket lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2003
Resolved 29 May 2003
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 27 May 2003
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2003
Resolved 29 May 2003
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 May 2003
Resolved
Repair FSDs C15 (not latching properly) and C23 (not closing).
Due 29 May 2003
Resolved 29 May 2003
Electrical › Lighting (emergency)
Issued 11 August 2002
Resolved
Provide proof that the photo luminescent strips have had the 5 year test in accordance with IMO Resolution A.752(18). LEGACY COMPONENT DESC: Low Location Lighting
Due 11 November 2002
Resolved 28 May 2003
Resolution: New luminescent strips installed.
Documentation › Manuals/Policy Documentation
Issued 12 May 2002
Resolved
Vessel's Security Plan does not meet the requirements of NVIC 04-02. Vessel must operate at a Security Level III posture as per their currently approved Security Plan until a revision had been submitted and returned "Approved" by USCG MSC. LEGACY COMPONENT DESC: Vessel Specific Watch Policy/Procedures
Due 29 May 2002
Resolved 27 June 2002
Resolution: Security plan verified as meeting enhanced requirements of NVIC 04-02 this date.
Electrical
Issued 6 May 2001
Resolved
Provide a Class report on the major cooling leak on #4 SSDG.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Engineering
Issued 6 May 2001
Resolved
Provide condition of class on the major cooling leak, #4 MDE.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Accommodation/Occupational Safety
Issued 6 May 2001
Resolved
Remove pad lock tab from all walkin refers to the satisfaction of USCG.
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Lifesaving
Issued 6 May 2001
Resolved
Bunker barge alongside, unable to exercise lifeboats 6,8,10,& 12. Prove proper operations on lifeboats upon return to NY on 13MAY01.
Condition: Unknown
Due 13 May 2001
Resolved 13 May 2001
Fire Fighting
Issued 6 May 2001
Resolved
Check valve on main fire pump inoperative, repairs completed and aprroved_x001C_ by USCG and Class prior to departing.
Condition: Unknown
Due 8 May 2001
Resolved 8 May 2001
Accommodation/Occupational Safety
Issued 6 May 2001
Resolved
Make permanent and proper repairs to the main laundry dryer filter system. filter house held together with tape and wire. Satisfaction of USCG.
Condition: Unknown
Due 13 May 2001
Resolved 13 May 2001
Electrical
Issued 6 August 2000
Resolved
Remove improper wires, and provide proper outlets for stage electrical equipment, IAW SOLAS 60 II/27. Make all repairs to the satisfaction of the USCG Marine Inspector.
Condition: Unknown
Due 12 September 2000
Resolved 12 September 2000
Fire Fighting
Issued 6 August 2000
Resolved
Remove equipment stored in A/C and Fire Main Piping space, located behind FSD F16A, IAW SOLAS II-2/26.
Condition: Unknown
Due 3 September 2000
Resolved 7 August 2000
Fire Fighting
Issued 7 May 2000
Resolved
Refit insulation over FSD 14, Aloha Deck frame 47 (port side), adjacent to cabin A398
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
Refit insulation over FSD F13, Fiesta Deck , frame 77, (stbd side), adjacent to cabin F386
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
FIT CABLE BLOCK (MCT) AND REFIT INSULATION OVER FSD F4, FIESTA DECK, FRAME 173, ADJACENT TO CABIN F103
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
PROPERLY DEAD END COILED CABLE (APPARENTLY FROM DETECTION SYSTEM ) ADJACENTTO FSD F4 FIESTA DECK, FRAME 173
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
REMOVE CARPETS STORED IN CREW GYMNASIUM
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
A PASS MACHINES, CANNOT BE STOWED IN BOARDING AREAS (STAIRWAY ENCLOSURES)
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
MAINTAIN CROSS FLOOD OPENINGS CLEAR IN WAY OF STORE AREAS
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Lifesaving
Issued 7 May 2000
Resolved
Make permanent and proper repairs to the D-Ring where the sea painter attaches to the rack.
Condition: Unknown
Due 21 May 2000
Resolved 10 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
DEMONSTRATE PROPER OPERATION OF THE FOLLOWING FIRE SCREEN DOORS (FSD):_x001C_ F11, D20, F14, L9, L8 (STUCK OR STICKS CLOSED),_x001C_ E8, D14A, D5C,A9, A4 (DON'T LATCH CLOSED) F12 (BINDS DURING CLOSING) A6 (DID NOT FUNCTION)
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
"SHOW GEAR BOXES" MUST BE REMOVED FROM CORRIDOR BEHIND CAROUSEL LOUNGE
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
C DECK FORWARD STAIR HOSPITAL STORES MUST BE REMOVED FROM STOREROOM 45 ONLYSAFETY MATERIALS ACCEPTABLE.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
Bridge Deck forward stair Linen locker must be emptied 45 only acceptable for safety materials
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
Refit insulation over FSD F5, Fiesta Deck inside stairway enclosure.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
Provide closing devise on Chef's Office Door so that it doesn't not block emergency escape trunk.
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Lifesaving
Issued 7 May 2000
Resolved
Add signage to main dinning room emergencies exits.
Condition: Unknown
Due 10 May 2000
Resolved 10 May 2000
Fire Fighting
Issued 7 May 2000
Resolved
Refit insulation over FSD F5, Fiesta Deck, frame 139, in stairway enclosure
Condition: Unknown
Due 22 May 2000
Resolved 22 May 2000
Fire Fighting
Issued 20 December 1991
Resolved
FIRE SCREEN DOORS NO. 6-C, 8-F, AND 15-A WOULD NOT LATCH AND/OR SECURE_x001C_ PROPERLY.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Fire Fighting
Issued 20 December 1991
Resolved
FIRE SCREEN DOOR INDICATORS FOR DOORS NO. 9-C, 12-C,11F, 16F, AND 15-A_x001C_ DID NOT PROPERLY INDICATE ON BRIDGE.
Condition: Unknown
Due 20 December 1991
Resolved 20 December 1991
Fire Fighting
Issued 1 June 1991
Resolved
Modify cross flooding piug on E deck to meet class A rating as per SOLAS Chapter II-2 Part A Reg 3, Par3, and provide drawings.
Condition: Unknown
Due 1 June 1991
Resolved 1 June 1991
Fire Fighting
Issued 11 October 1990
Resolved
FOR EACH BREATHING APPARATUS A FIREPROOF LIFELINE OF SUFFICIENT LENGTH AND STRENGTH SHALL BE PROVIDED CAPABLE OF BEING ATTACHED BY MEANS OF A SNAPHOOKTO THE APPARATUS OR TO A SEPARATE BELT.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Navigation
Issued 11 October 1990
Resolved
HYDRAULIC POWER-OPERATED STEERING GEAR SHALL BE PROVIDED WITH A LOW-LEVEL ALARM FOR EACH HYDRAULIC FLUID RESERVOIR. AUDIBLE AND VISIBLE ALARMS SHALLBE PROVIDED ON THE NAVIGATING BRIDGE AND IN THE MACHINERY SPACE WHERE THEY CAN BE READILY OBSERVED.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Lifesaving
Issued 11 October 1990
Resolved
A LIFEJACKET SHALL BE PROVIDED FOR EVERY PERSON ON BOARD THE VESSEL AND, INADDITION, A NUMBER OF LIFEJACKETS SUITABLE FOR CHILDREN (UNDER 32 KILOGRAM)EQUAL TO AT LEAST 10% OF THE NUMBER OF PASSENGERS ON BOARD SHALL BE PROVIDED.
Condition: Unknown
Due 11 October 1990
Resolved 11 October 1990
Documentation
Issued 7 February 1987
Resolved
33CFR 151.19 IOPP CERTIFICATE DID NOT HAVE CURRENT ENDORSEMENT.
Condition: Unknown
Due 7 February 1987
Resolved 7 February 1987