LAILA
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named LAILA
LAILA is a 1970 freight ship. The Coast Guard has recorded 20 inspections since 1984, most recently in March 2006, along with 41 deficiencies and 4 operational controls.
Records from 1984 to 2006. Most recent: operational control imposed, 15 March 2006.
- Built
- 1970
- Last inspected
- 15 March 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 41 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7024158 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
XULL9
222035
Flag
BELIZE
—
Maury page id
psix-222035
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it498 - Convention (Subpart B), Gross Ton
283 - Convention (Subpart B), Net Ton
789 - Dead Weight, Ton
283 - Convention (Subpart B), Net Ton
789 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
15 March 2006
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2604230
9 September 2004
PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2191350
2 July 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 392883
22 April 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 176308
2 March 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 757158
1 March 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 205300
21 February 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 388562
3 January 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 386588
6 October 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 383591
10 September 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382612
8 September 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382588
27 July 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381059
20 July 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 652796
11 June 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351890
4 October 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 332947
6 September 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 325506
21 October 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 319358
12 March 1986
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 508975
17 April 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 301450
29 October 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 518577
Deficiency record · 41
Navigation
Issued 2 July 1996
Resolved
VESSEL DID NOT HAVE CHARTS 12327, 12326, 12334, 12335, 12402, ALONG WITH ALL CORRECTIONS. SOLAS 60.
Navigation
Issued 2 July 1996
Resolved
U.S.COAST PILOT VOL.2 1994 NEEDS CORRECTIONS 52/94, 1/95, 25/95, 44/95.
Electrical
Issued 2 July 1996
Resolved
EMERGENCY GENERATOR FOR FIRE FIGHTING SYSTEM INOPERABLE. SOLAS 60.
Lifesaving
Issued 2 July 1996
Resolved
REMOVE ALL FLAMMABLE STORES FROM EMERGENCY GENERATOR ROOM. SOLAS 60.
Construction/Loadline
Issued 2 July 1996
Resolved
REPLACE OR REPAIR ALL HATCH COVER SECURING MECHANISMS. SOLAS 60.
Electrical
Issued 2 July 1996
Resolved
REPAIR EXAUST LEAK ON MAIN GENERATOR. SOLAS 60.
Documentation
Issued 2 July 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Construction/Loadline
Issued 2 July 1996
Resolved
REPAIR HOLES ON CARGO HATCH COVERS. SOLAS 60.
Electrical
Issued 2 July 1996
Resolved
REPAIR NUMEROUS ELECTRICAL HAZARDS THROUGHOUT VESSEL. SOLAS 60.
Lifesaving
Issued 2 July 1996
Resolved
ALL LIFERAFTS NEED SERVICING. SOLAS 60.
Lifesaving
Issued 2 July 1996
Resolved
LIFERINGS NEED RETRO-REFLECTIVE TAPE. SOLAS 60.
Construction/Loadline
Issued 2 July 1996
Resolved
REPLACE ALL CARGO HATCH COVER GASKETS. SOLAS 60.
Electrical
Issued 2 July 1996
Resolved
REPAIR WATER PUMP ON MAIN GENERATOR. SOLAS 60.
Lifesaving
Issued 2 July 1996
Resolved
REPAIR LIFEBOAT EMBARKATION DECK LIGHTING. SOLAS 60.
Documentation
Issued 6 October 1995
Resolved
Provide valid loadline certificate and demonstrate compliance prior to departure.
Documentation
Issued 10 September 1995
Resolved
VESSEL IS TO COMPLY WITH ALL FLAG AND SURVEYOR'S REQUIREMENTS AND RECOMMENDATIONS. (25 LISTED ON LOAD LINE CERT)
Construction/Loadline
Issued 10 September 1995
Resolved
PERMANENTLY AFFIX LOADLINE MARKING TO HULL PRIOR TO LOADING.
Documentation
Issued 10 September 1995
Resolved
PROVIDE VALID LOADLINE CERTIFICATE
Lifesaving
Issued 8 September 1995
Resolved
Complete all Flag Surveyors recommendations (25 listed) for repairs to vessel and report attesting to their completion.
Fire Fighting
Issued 8 September 1995
Resolved
Provide two fireman's outfits.
Navigation
Issued 8 September 1995
Resolved
Provide deviation table for magnetic compass
Unknown
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE GUARDS FOR ALL ROTATING MACHINERY AND BELT DRIVEN MACHINERY._x001C_ _x001C_ _x001C_
Navigation
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE CURRENT DEVIATION TABLE._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE COVERS FOR GENERATORS ELECTRICAL MOTOR._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 27 July 1995
Resolved
VESSEL IS TO CORRECTLY INSTALL A WEAK LINK FOR BOTH LIFE RAFTS WHICH IS IN COMPLIANCE WITH THE REGULATIONS. _x001C_ _x001C_ _x001C_
Lifesaving
Issued 27 July 1995
Resolved
VESSEL IS TO MARK ALL LIFE SAVING GEAR WITH THE SHIP'S NAME AND HOMEPORT._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE IOPP CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 27 July 1995
Resolved
VESSEL IS TO COMPLY WITH ALL FLAG AND SURVEYOR'S REQUIREMENTS AND RECOMMENDATIONS._x001C_ _x001C_ _x001C_
Documentation
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE RECORDS IAW 33CFR 155.820. (LETTER OF DESIGNATION, DECLARATION OF INSPECTION) PRIOR TO NEXT US VISIT._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE BALLAST TANK TABLES._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE COFR._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE PROOF OF OPERATION ON NEWLY INSTALLED OILY WATER SEPARATOR._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 27 July 1995
Resolved
VESSEL IS TO PROVIDE FOR TWO COMPLETE FIREMAN OUTFITS._x001C_ _x001C_ _x001C_ _x001C_
Engineering
Issued 27 July 1995
Resolved
VESSEL IS TO TEST RUN MAIN ENGINES AND PROPULSION CONTROLS DOCKSIDE IN PRESENCE OF FLAG SURVEYOR AND PROVIDE REPORT TO USCG._x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 11 June 1992
Resolved
A violation of 46 CFR 42.15-10(a) in that the superstructure access doors could not be made weathertight because 5 inches of gasket on an open deck door were missing. Vessel is subject to U.S. regulations iaw 46 CFR 2.01-13(b).
Deck/Cargo
Issued 11 June 1992
Resolved
Vessel had 2 compressed gas cylinders (one oxygen one aceteylene) making direct contact with vessel deck and sides. Additionally, these cylinders_x001C_ were not protected from direct sunlight.
Deck/Cargo
Issued 11 June 1992
Resolved
One of the vehicles in the cargo hold had the battery cables still connected.
Lifesaving
Issued 11 June 1992
Resolved
Vessel had 55 gallon drums stowed on deck giving no clear access to anchor.
Documentation
Issued 6 September 1988
Resolved
A VIOLATION OF 33 CFR 155.730 IN THAT THERE WERE NO OIL TRANSFER PROCEDURESONBOARD THE VESSEL.
Documentation
Issued 21 October 1987
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Navigation
Issued 21 October 1987
Resolved
NO INLAND NAVIGATION BOOK.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.