MAURY USCG vessel records Sign in
← All vessels

MAVERICK II

MAVERICK II is a 1970 freight ship. The Coast Guard has recorded 50 inspections since 1985, most recently in July 2006, along with 97 deficiencies and 7 operational controls.

Records from 1985 to 2006. Most recent: inspection, 14 July 2006.

Built
1970
Last inspected
14 July 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7026596 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP-7516
222062
Flag
VENEZUELA
—
Maury page id
psix-222062

Inspections, by type

…with no type recorded38
Years with a record 17 calendar years (1985–2006)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2042 - Convention (Subpart B), Gross Ton
1068 - Convention (Subpart B), Net Ton
2501 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 50

14 July 2006 MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2712481
17 April 2006 In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2626985
28 February 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2610280
8 February 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2581550
22 January 2006 Ballast Water Examination · PI Safety Exam · ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2570827
11 January 2006 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2564787
10 November 2005 ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PI Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2532614
10 November 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2534578
12 October 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2512773
30 September 2005 ISPS III Exam · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2504988
8 September 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2487126
8 September 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2487459
7 September 2005 PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2486050
26 August 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2475333
26 August 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2475610
26 August 2005 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2475735
25 August 2005 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2474213
22 August 2005 MARPOL Annex I Examination · ILO-147 Exam · MARPOL Annex V Examination · STCW 95 Exam · ISM Exam · Loadline Exam · Ballast Water Examination · ISPS II Exam · PI Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2470739
13 October 2000 Port Security Assessment
Type not classified · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 583621
19 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 273725
6 October 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 433502
17 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 497254
7 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 431357
20 May 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428863
28 January 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 447904
12 August 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418908
6 July 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 417404
24 September 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 408198
13 September 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 407958
4 July 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765286
3 July 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 195107
20 June 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 405181
6 December 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 515746
5 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 395089
15 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 392325
5 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 386479
8 June 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 379170
18 August 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 369633
14 June 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367748
31 May 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367379
1 September 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 652945
22 August 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 360591
22 June 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351959
22 March 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 342689
5 February 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 335470
7 December 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 327280
8 April 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 441957
15 May 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 308821
15 October 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 437389
2 February 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 300451

Deficiency record · 97

Stability › Watertight Integrity › General
Issued 15 July 2006 Resolved
Remove Extension cords running through watertight door leading to the emergency fire pump.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 8 January 2007
Resolution: Received class report
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 July 2006 Resolved
Replace light and light holder for ring bouy next to the cargo hole NO.2 Starboard Side, to the satisfaction of the Coast Guard
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 15 July 2006
Resolved 8 January 2007
Resolution: Received class report
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 14 July 2006 Resolved
Emergency fire pump required to support two jets of water to satisfaction of administration. Emergency fire pump will not start. ( Must be repaired to the satisfaction of the Coast Guard)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2006
Resolved 15 July 2006
Resolution: Witnessed satisfactory operation of the emergency fire pump
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2006 Resolved
Repair overhead light in emergency fire pump space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 August 2006
Resolved 8 January 2007
Resolution: Received class report
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure
Issued 22 January 2006 Resolved
3x Portable Fire Extinguishers in Engine Room overcharged & 1 missing discharge nozzle / SOLAS74(amend) II-2/10.3.2.4
Action required: 705 - Other - as specified
Resolved 22 January 2006
Resolution: Crew rectified deficiency prior to departure of USCG inspectors
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 22 January 2006 Resolved
Company has not established sufficient procedures to ensure that fire extinguishers are maintained in conformity with relevant regulations: monthly check #18 does not provide for verifying pressure of extinguishers / SOLAS74 (amend) IX/5, ISM 10.1
Action required: 705 - Other - as specified
Due 21 February 2006
Resolved 28 February 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 10 November 2005 Resolved
Make permanent repairs to softpatch on sewage pipe and air conditioner pipe. To satisfaction of Flag.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 November 2005
Resolution: RECIEVED CLASS REPORT
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 10 November 2005 Resolved
Fire detection system not ready for immediate operations at all times. Fix to satisfaction of the Administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 November 2005
Resolution: RECIEVED CLASS REPORT
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 30 September 2005 Resolved
Composition of crew insufficient to meet requirements of the Minimum Safe Manning Certificate. (1 Motorman/Oiler not currently onboard.) Rectify to the satisfaction of the Coast Guard. Crew member is anticipated to be onboard 02oct05 @ 0200.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2005
Resolution: Received Flag Administration report attesting to presence of qualified motorman on board as of 2 Oct 2005.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 30 September 2005 Resolved
Emergency fire pump exhaust fills the forepeak space and emergency fire pump space while in operation. Verify proper exhaust and ventilation. To be rectified to the satisfaction of the certificate issuing authority.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2005
Resolution: Received Flag Administration report attesting to satisfactory repair of exhaust gaskets.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 30 September 2005 Resolved
Instructions for operating the CO2 fixed fire fighting system was only found in Russian (working language of the crew). Provide copy written in language of Flag State, English, French, or Spanish.
Action required: 705 - Other - as specified
Due 30 October 2005
Resolved 2 October 2005
Resolution: Received Flag Administration report attesting to Flag requirement to provide instructions in English prior to 2 Nov 2005.
Personnel › Training › Fire Fighting Basic
Issued 7 September 2005 Resolved
Chief Engineer, 2nd Engineer and crew did not know where or how to start fire pumps.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 7 September 2005 Resolved
Vessel has only one licensed and endorsed GMDSS operator. Vessel is required two at a minimum.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Personnel › Training › GMDSS
Issued 7 September 2005 Resolved
Captain unable to use communications equipment INMARSAT.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 September 2005 Resolved
Ships generator raw water cooling piping has a hole that was soft patched with no intention of permanent repairs.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 7 September 2005 Resolved
USCG doubts the validity of the vessels SMS. Conduct audit of SMS. Request external audit be conducted by third party.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 September 2005 Resolved
Power panel is corroded and will not close in the vestibule to the bow thruster room.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Construction/Loadline › Structures › Door
Issued 7 September 2005 Resolved
WTD on main deck port side passageway is warped and will not close.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Construction/Loadline › Structures › End Bulkhead
Issued 7 September 2005 Resolved
FWD bulkhead in steering gear room has 6" x 6" hole and the repair was not approved by flag admin or class.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Documentation › Logs/Records › Enhanced Survey Report File
Issued 7 September 2005 Resolved
Vessel must provide documentation to USCG attesting to last two drydock dates.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Construction/Loadline › Structures › Door
Issued 7 September 2005 Resolved
Water tight door to bow thruster is warded and has improper gasket and will not close properly.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Documentation › Logs/Records › Logbook (official)
Issued 7 September 2005 Resolved
USCG issued two strucutral defs on 02SEP05, defs were not addressed or reported on vessel SMS. Non conformities, no logged in vessel SMS log.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 7 September 2005 Resolved
USCG doubt validity of ISM certificates including SMC and Document of Compliance. Vessel change classification sociaty and interim. SMC was issued none of the criteria for issuing an interim SMC or DOL were met.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Navigation › Piloting/Steering › Marine Charts
Issued 7 September 2005 Resolved
Nautical charts have not been updated by crew.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Navigation › Piloting/Steering › Notices to Navigation
Issued 7 September 2005 Resolved
Vessel does not have current edition of Notice to Mariners (used to update charts).
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 7 September 2005 Resolved
Emergency steering instructions not posted on the bridge.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 7 September 2005 Resolved
Fire plans not approved by vessels flag. All deficiencies shall be corrected to the satisfaction of an IACS member or direct representative of the flag administration.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2005
Resolved 29 September 2005
Construction/Loadline › Markings › Load Line Mark
Issued 7 September 2005 Resolved
Ensure required load line mark on hull is in accordance with ship's load line document.
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 12 October 2005
Construction/Loadline › Structures › Door
Issued 22 August 2005 Resolved
Watertight door leading to the bow thruster room from the weather deck has damaged gasket preventing the door from sealing properly. Door must be fixed to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 September 2005
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 22 August 2005 Resolved
Forward bulkhead between main engine room and steering gear room has a 6" x 6" hole. Hole must be fixed to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 September 2005
Resolved 29 September 2005
Operations/Management › Drills/Instruction › Fire
Issued 22 August 2005 Resolved
Fire drills were inadequate. Fire drill must be completed to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Resolution: Attended vessel and viewed satisfactory fire drill.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 22 August 2005 Resolved
Abandon ship drills were inadequate. Abandon ship drill must be completed to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 August 2005
Resolution: Attended vessel and witnessed satisfactory abandon ship drill.
Fire Fighting › Fire Hoses › Condition
Issued 22 August 2005 Resolved
All weather deck fire hoses are either worn, wasted, or improperly assembled including missing nozzles and/or couplings. Repair and replace as necessary prior to departure from port
Action required: 705 - Other - as specified
Resolved 24 August 2005
Resolution: Received receipt via fax for the purchase of new fire hoses.
Electrical
Issued 13 October 2000 Resolved
Replace missing light cover in stairway entering pilot house.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Unknown
Issued 13 October 2000 Resolved
PROVIDE PROOF OF PROPER OPERATION OF OWS PRIOR TO DEPARTURE.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Navigation
Issued 13 October 2000 Resolved
Provide current charts with corrections.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Documentation
Issued 13 October 2000 Resolved
Provide main deck referance mark IAW vsl LoadLine certificate, and provide class report that items have been corrected.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Lifesaving
Issued 13 October 2000 Resolved
Replace hose on dewatering pump in port lifeboat and repair hose in stbd lifeboat.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Navigation
Issued 13 October 2000 Resolved
Provide continuous operation of depth sounding recorder.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Documentation
Issued 13 October 2000 Resolved
Provide garbage management plan.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Lifesaving
Issued 13 October 2000 Resolved
Provide (post) launching instructions at lifeboat stations (port + stbd)
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Documentation
Issued 13 October 2000 Resolved
UPDATE SOPEP WITH CURRENT INFO AND APPROVAL BY FLAG STATE PRIOR TO DEPARTURE.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Documentation
Issued 13 October 2000 Resolved
PROVIDE CREW LIST IN ACCORDANCE WITH SAFE MANNING DOCUMENT PRIOR TO DEPARTURE.
Condition: Unknown
Due 16 October 2000
Resolved 16 October 2000
Documentation
Issued 7 August 1999 Resolved
PROVIDE ON BOARD AN UPDATED ITC TONNAGE CERTIFICATE.
Condition: Unknown
Due 15 October 1999
Resolved 8 October 1999
Deck/Cargo
Issued 7 August 1999 Resolved
PROVIDE A SPILL CONTAINMENT FOR THE LUBE OIL FILL LINE STARBOARD SIDE._x001C_ PRIOR TO LOADING LUBE OIL IN U.S. WATERS.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Engineering
Issued 7 August 1999 Resolved
PROVIDE ON BOARD A STANDARD DISCHARGE CONNECTION IN ACCORDANCE WITH THE VESSELS IOPP CERTIFICATE. PRIOR TO DISCHARGING SLOPS.
Condition: Unknown
Due 7 October 1999
Resolved 8 October 1999
Documentation
Issued 7 August 1999 Resolved
UPDATE THE SHIPS SOPEP WITH CURRENT INFORMATION FOR THE PORT OF MIAMI, IN THE NOTIFICATION SECTION. PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Lifesaving
Issued 7 August 1999 Resolved
MAKE REPAIR TO THE PORT LIFEBOAT DAVIT GEAR BOX. PRIOR TO DEPARTURE.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Documentation
Issued 7 August 1999 Resolved
Provide Class report for all 3 prior to departure items to MSO Miami, Priorto departure.
Condition: Unknown
Due 9 August 1999
Resolved 9 August 1999
Documentation
Issued 7 August 1999 Resolved
Provide a licensed second mate on board vessel in accordance with the vessels safe manning doc. Prior to departure.
Condition: Unknown
Due 7 August 1999
Resolved 7 August 1999
Lifesaving
Issued 7 August 1999 Resolved
Provide a crew watch schedule on board the vessel in accordance with STCW 95 VIII/1 .
Condition: Unknown
Due 4 September 1999
Resolved 7 August 1999
Navigation
Issued 7 August 1999 Resolved
PROVIDE CHARTS 11460, 11466 AND 11468 AND THE INLAND NAVIGATIONAL RULES OF THE ROAD.
Condition: Unknown
Due 4 September 1999
Resolved 7 August 1999
Fire Fighting
Issued 7 August 1999 Resolved
PROVIDE AN UPDATED FIRE CONTROL PLAN.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Fire Fighting
Issued 7 August 1999 Resolved
PROVIDE BELT GUARDS AND REPAIR PRESSURE GAUGE AND LOCATE EXHAUST LEAK ON THE EMERGENCY FIRE PUMP.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Lifesaving
Issued 7 August 1999 Resolved
PROVIDE RETRO REFLECTIVE TAPE ON THE BOTTOM OF THE PORT AND STARBOARD LIFEBOATS.
Condition: Unknown
Due 4 September 1999
Resolved 7 August 1999
Unknown
Issued 7 August 1999 Resolved
REPLACE VENT COVER AND GASKET FOR A/C VENT AT OUTSIDE AFT BRIDGE DECK PORT SIDE.
Condition: Unknown
Due 6 October 1999
Resolved 6 October 1999
Lifesaving
Issued 7 August 1999 Resolved
PROVIDE AN OPERATIONAL RING BUOY LIGHT FOR THE RING BUOY LOCATED AFT MAIN DECK STARBOARD SIDE.
Condition: Unknown
Due 4 September 1999
Resolved 7 August 1999
Navigation
Issued 7 August 1999 Resolved
PROVIDE A CLASS SOCIETY REPORT ADDRESSING THE DIFFERENCE IN DEGREES BETWEENTHE AUX STEERING ROOM RUDDER ANGLE INDICATOR AND THE MAIN STEERING STATION.DIFFERENCE IS BETWEEN 5 AND 6 DEGREES.
Condition: Unknown
Due 4 September 1999
Resolved 7 August 1999
Deck/Cargo
Issued 6 July 1998 Resolved
Prior to 01 AUG 1998, provide missing cargo hatch securing dogs.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Electrical
Issued 6 July 1998 Resolved
No later than 29 July 1998, replace cracked and wasted battery wires for emergency power system.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Fire Fighting
Issued 6 July 1998 Resolved
Prior to departure, perform satisfactory fire and abandon ship drills in the presence of a USCG marine inspector.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Fire Fighting
Issued 6 July 1998 Resolved
Prior to loading, prove satisfactory fire main hose pressure with both the main and emergency fire pumps.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Documentation
Issued 6 July 1998 Resolved
VESSEL HAD A CONTAINER THAT WAS NOT MANIFESTED, NO SHIPPING PAPERS AND NO PLACARDS THAT CONTAINED A VEHICLE. MUST PROVIDE ALL PAPERWORK PRIOR TO DEPARTURE.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Fire Fighting
Issued 6 July 1998 Resolved
Prior to 01 August 1998, provide and post fire control plan with appropriate color coding that is legible.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Documentation
Issued 6 July 1998 Resolved
No later than 29 July 1998, Class society to address the remarks section onthe vessel's Tonnage certificate to reflect the vsl's National tonnage of 1567. This tonnage is indicated on the class-issued certificates, but not on the Tonnage certificate.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Fire Fighting
Issued 6 July 1998 Resolved
Prior to departure, service the fixed CO2 system. A CO2 bottle in the Fixed system storage space had frost on the cap, and a hissing noise indicating a CO2 leak.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Lifesaving
Issued 6 July 1998 Resolved
Prior to departure, provide a proper sea painter, securing strap and servicing for the port side liferaft. The weathertight seals on the liferaft were opened and may have taken on water.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Deck/Cargo
Issued 6 July 1998 Resolved
Prior to offloading cargo, remove placards from empty containers IAW 49 CFR172.500. Vessel had an empty container on board with a corrosive placard on the container.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Electrical
Issued 6 July 1998 Resolved
No later than 29 July 1998, provide cover for exposed electrical panel by generator space.
Condition: Unknown
Due 6 July 1998
Resolved 6 July 1998
Deck/Cargo
Issued 6 July 1998 Resolved
Prior to 01 AUG 1998, replace wasted anchor chain for starboard anchor.
Condition: Unknown
Due 13 August 1998
Resolved 13 August 1998
Lifesaving
Issued 20 June 1997 Resolved
PROVIDE NEW BATTERY FOR EPIRB EXPIRED 1995.
Condition: Unknown
Due 20 June 1997
Resolved 4 July 1997
Lifesaving
Issued 20 June 1997 Resolved
PROVE PROPER OPERATION OF STBD LIFEBOAT MOTOR.
Condition: Unknown
Due 20 June 1997
Resolved 4 July 1997
Lifesaving
Issued 20 June 1997 Resolved
REPLACE/REPAIR SCBA FIRE SUIT. PURGE IS STICKING.
Condition: Unknown
Due 20 June 1997
Resolved 4 July 1997
Unknown
Issued 20 June 1997 Resolved
PROVIDE INFORMATION IN SOPEP FOR CLEAN-UP CONNTRACTOR LOCAL AREA AND UPDATEUSCG CONTACT NUMBERS. PROVIDE LOG FOR LOGGING SPILL DRILLS.
Condition: Unknown
Due 20 June 1997
Resolved 4 July 1997
Navigation
Issued 20 June 1997 Resolved
PROVIDE NON SKID SURFACE STEERING SPACE.
Condition: Unknown
Due 16 September 1997
Resolved 16 September 1997
Documentation
Issued 20 June 1997 Resolved
PROPERLY INDICATE ALL TANK LOCATIONS AND QUANTITIES IN OIL RECORD BOOK.
Condition: Unknown
Due 20 June 1997
Resolved 4 July 1997
Lifesaving
Issued 20 June 1997 Resolved
PROVIDE NEW BATTERIES FOR WATER LIGHTS BOTH STBD AND PORT SIDE.
Condition: Unknown
Due 4 July 1997
Resolved 4 July 1997
Fire Fighting
Issued 20 June 1997 Resolved
PROVIDE CLASS STATEMENT ON LOW PRESSURE FROM STERN EMERGENCY FIRE PUMP LOCATION.
Condition: Unknown
Due 20 June 1997
Resolved 4 July 1997
Navigation
Issued 20 June 1997 Resolved
PROVE OPERATION OF SECONDARY STEERING PUMP.
Condition: Unknown
Due 20 June 1997
Resolved 4 July 1997
Unknown
Issued 20 June 1997 Resolved
PROVIDE CLASS STATEMENT ADDRESSING REQUIREMENTS PRIOR TO RETURN TO US WATERS.
Condition: Unknown
Due 16 September 1997
Resolved 16 September 1997
Documentation
Issued 20 June 1997 Resolved
PROVIDE EVIDENCE OF WASTE/SLUDGE OIL SINCE LAST LOGGED ENTRY OF OCT93 IN OIL RECORD BOOK.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Documentation
Issued 20 June 1997 Resolved
PROPERLY LOG ENTRIES IN OIL RECORD BOOK FOR TRANSFERS OF OIL RESIDUES/WASTE/SLUDGE FROM VSL TO RECEPTION FACILITY.
Condition: Unknown
Due 16 September 1997
Resolved 16 September 1997
Documentation
Issued 15 June 1996 Resolved
PROVIDE APPROVED STABILITY BOOK FROM CLASS SOCIETY.
Condition: Unknown
Due 5 September 1996
Resolved 5 September 1996
Fire Fighting
Issued 5 January 1996 Resolved
repair pinhole lead to firemain piping on stbd side main deck fire station aft of cargo hold.
Condition: Unknown
Due 5 January 1996
Resolved 8 January 1996
Fire Fighting
Issued 5 January 1996 Resolved
MAKE PERMANENT REPAIRS TO PINHOLE LEAK IN FIREMAIN, STBD SIDE MAIN DECK FIRE STATION AFT OF CARGO HOLD AND PROVIDE STATEMENT FROM CLASS REGARDING THE REPAIR.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Documentation
Issued 8 June 1995 Resolved
PROVIDE PROPER ENDORSEMENT ON CARGO SHIP SAFETY CONSTRUCTION CERTIFICATE.
Condition: Unknown
Due 12 July 1995
Resolved 16 June 1995
Documentation
Issued 8 June 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 June 1995
Resolved 16 June 1995
Lifesaving
Issued 31 May 1994 Resolved
THE VESSEL DID NOT HAVE THE PROPER AMOUNT OF PERSONAL FLOTATION DEVICES FOREVERY PERSON ON BOARD. AS REQUIRED BY 46 C.F.R 25.25
Condition: Unknown
Due 30 June 1994
Resolved 2 June 1994
Navigation
Issued 31 May 1994 Resolved
VESSEL DECK LOGBOOK DID NOT HAVE THE PROPER PRE ARRIVAL AND DEPARTURE GEAR TEST LOGGED AS REQUIRED BY 33 C.F.R. 146.25(A)
Condition: Unknown
Due 30 June 1994
Resolved 2 June 1994
Documentation
Issued 31 May 1994 Resolved
THE VESSEL DID NOT HAVE STABILITY INFORMATION IN THE PROPER BOOKLET FORMAT AS REQUIRED BY 46 C.F.R. 42.15-1_x001C_ _x001C_
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Engineering
Issued 22 August 1993 Resolved
OIL TRANSFER PROCEDURES FOUND TO BE INCOMPLETE. FIRST TIME THIS VESSEL _x001C_ HAS BEEN ISSUED A NOTICE OF VIOLATION FOR THIS TYPE OF DISCREPANCY. COMDTINST 16200.3A RECOMMENDS A $500.00 PENALTY FOR FIRST TIME OFFENDERS,_x001C_
Condition: Unknown
Due 15 June 1994
Resolved 15 June 1994
Construction/Loadline
Issued 22 August 1993 Resolved
UPPER DECK LOAD LINE WAS NOT PAINTED. THIS IS SHIPS FIRST LOAD LINE DISCREPANCY.
Condition: Unknown
Due 23 August 1993
Resolved 1 September 1993
Construction/Loadline
Issued 22 June 1992 Resolved
A violation of 46 C.F.R. 42.13-40(a) in that the upper deck mark was not plainly visible.Vsl is subject to U.S. regulations per 46 CFR 2.01-13(b).
Condition: Unknown
Due 22 June 1992
Resolved 15 July 1992
Documentation
Issued 22 June 1992 Resolved
IOPP was not available for inspection.
Condition: Unknown
Due 22 June 1992
Resolved 15 July 1992
Documentation
Issued 22 March 1991 Resolved
A VIO OF 33 CFR 164.333(A)(2)(ii), IN THAT IN VSL FAILED TO HAVE ONBOARD A CURRENT COPY OF THE USCG LIGHT LIST OR FOREIGN EQUIVALENT
Condition: Unknown
Due 22 June 1992
Resolved 15 July 1992
Documentation
Issued 22 March 1991 Resolved
A VIOLATION OF 33 CFR 164.35(k), IN THAT THE VSL FAILED TO HAVE ONBOARD A COPY OF THE BLOCK DIAGRAM FOR THE STEERING CHANGEOVER PROCEDURES FOR REMOTESTEERING GEAR CONTROL SYSTEMS.
Condition: Unknown
Due 22 June 1992
Resolved 15 July 1992
Navigation
Issued 5 February 1990 Resolved
A VIOLATION OF 33 CFR 164.35(G)(6) IN THAT THE VESSEL HAD A MANEUVERING FACT SHEET BUT IT WAS INCOMPLETE.
Condition: Unknown
Due 22 March 1991
Resolved 5 February 1990

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.