MAURY USCG vessel records Sign in
← All vessels

ANDRIOTISA

ANDRIOTISA is a 1970 freight ship. The Coast Guard has recorded 48 inspections since 1985, most recently in December 2004, along with 119 deficiencies — 1 with no resolution recorded — and 10 operational controls.

Records from 1985 to 2004. Most recent: inspection, 10 December 2004.

Built
1970
Last inspected
10 December 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

222082
Flag
THAILAND
—
Maury page id
psix-222082

Inspections, by type

…with no type recorded40
…past their stated due date1
Years with a record 20 calendar years (1985–2004)
The 48 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1592 - Regulatory (Subpart C or D), Gross Ton
1223 - Regulatory (Subpart C or D), Net Ton
3005 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 48

10 December 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2256805
6 December 2004 Ballast Water Examination · STCW 95 Exam · MARPOL Annex V Examination · PI Safety Exam · ISPS III Exam · ILO-147 Exam · MARPOL Annex I Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2254559
7 October 2004 MARPOL Annex I Examination · STCW 95 Exam · Loadline Exam · MARPOL Annex V Examination · ISPS II Exam · PI Safety Exam · ILO-147 Exam · Ballast Water Examination · ISM Exam · Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2214675
16 August 2004 PII Safety Exam
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2167890
23 June 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2108568
29 November 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1955976
28 November 2003 MARPOL Annex V Examination · Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1955711
17 October 2002 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1695290
13 October 2002 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1690591
4 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1491016
15 July 2001 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 291945
28 August 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 281486
5 March 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 275428
8 September 1999 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 432882
1 August 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 431247
21 June 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 429828
13 April 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 427448
17 June 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 417543
6 December 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 410800
4 December 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 410639
16 June 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 404842
16 April 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 402456
14 May 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 391276
10 May 1995 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 378440
10 May 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 873903
17 March 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 376213
18 October 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 371468
24 May 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 367080
12 April 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 366059
12 April 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1370821
18 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 527632
10 March 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 646696
24 February 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 491314
7 May 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 440059
23 October 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 346845
12 December 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 340942
20 September 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 332680
20 March 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 510437
12 September 1988 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 325573
13 April 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 540149
12 April 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 469295
12 February 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314233
12 August 1986 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 445595
13 June 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 499410
10 March 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 307403
11 December 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 499822
11 October 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 304831
26 July 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 303394

Deficiency record · 119

Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 6 December 2004 Resolved
Vessel was found not to be manned in accordance with the minimum safe manning certificate. The chief mate, second engineer, and AB had invalid licenses and certificates.
Action required: 705 - Other - as specified
Due 6 December 2004
Resolved 7 December 2004
Resolution: Received report from flag.
Engineering › Steering Gear System › Ram
Issued 6 December 2004 Resolved
Hydraulic oil leak on port side steering gear ram.
Action required: 705 - Other - as specified
Due 20 December 2004
Resolved 7 December 2004
Resolution: Received class report.
Engineering › Steering Gear System › Valve
Issued 6 December 2004 Resolved
Hydraulic leak on valves for emergency steering pump.
Action required: 705 - Other - as specified
Due 20 December 2004
Resolved 7 December 2004
Resolution: Received class report.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Injector (fuel injection)
Issued 6 December 2004 Resolved
Main generators have rubber connections on drain valves.
Action required: 705 - Other - as specified
Due 20 December 2004
Resolved 7 December 2004
Resolution: Received class report.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 6 December 2004 Resolved
Fuel leak on emergency firepump.
Action required: 705 - Other - as specified
Due 20 December 2004
Resolved 7 December 2004
Resolution: Received class report.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 6 December 2004 Resolved
Lube oil leak on emergency firepump.
Action required: 705 - Other - as specified
Due 20 December 2004
Resolved 7 December 2004
Resolution: Received class report.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 6 December 2004 No resolution recorded
The M/V ANDRIOTISA is hereby denied entry into all U.S. ports until adequate proof of compliance with the ISM code is provided to the cognizant COTP/[name withheld] shall be in the form of a five-year SMC, and documented internal and external ISM audits by an acceptable third party recognized organization. Members recognized by the IACS are considered to be acceptable third party organizations.
Action required: 705 - Other - as specified
Due 6 December 2004 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 October 2004 Resolved
Both ship radars are inoperable. (33 CFR 164.35)
Action required: 705 - Other - as specified
Resolved 19 October 2004
Resolution: Received tech report stating one radar is fully operational. Vessel is only required one operational radar.
Lifesaving › Launching Appliances › Davit
Issued 7 October 2004 Resolved
Neither lifeboat sits in davit cradle. (SOLAS 60 Chapter III, Regulation 36)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received report from IBS stating both lifeboats sit in cradles.
Lifesaving › Launching Appliances › Davit
Issued 7 October 2004 Resolved
Forward gripe on starboard lifeboat davit wasted. (SOLAS 60 Chapter III, Regulation 36)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: IBS sent report stating gripe on stbd boat was renewed.
Lifesaving › Launching Appliances › Davit
Issued 7 October 2004 Resolved
The davit lifeboat dog is frozen and inoperable. (SOLAS 60, Chapter III, Regulation 36)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: IBS states both lifeboat dogs have been released and are operable.
Lifesaving › Launching Appliances › Davit
Issued 7 October 2004 Resolved
The davit track wheels for portside lifeboat are frozen. (SOLAS 60, Chapter III, Regulation 36)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: IBS states davit track wheels on port side have been released and are operable.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 7 October 2004 Resolved
Vessel not manned in accordance with minimum safe manning certificate. Three AB's are without national licenses, and Chief Mate does not have Panamanian endorsement on board. (SOLAS 60, Chapter V, Regulation 13)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Lifesaving › Launching Appliances › Falls
Issued 7 October 2004 Resolved
Port and Starboard lifeboat falls show lack of maintenance. (SOLAS 60, Chapter III, Regulation 36)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: IBS reports lifeboat falls have received maintenance and have been greased.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 7 October 2004 Resolved
Missing handrail on starboard main deck ladder. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: PRS reports hand rail found repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 October 2004 Resolved
Starboard main engine lube oil cooler has saltwater leak. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Deck/Cargo › Ballast › Piping
Issued 7 October 2004 Resolved
Ballast pump saltwater inlet pipe has soft patch. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: PRS reports pipe is repaired.
Fire Fighting › Fire Main › Condition
Issued 7 October 2004 Resolved
Vessel has hole in fire main in engine room. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: PRS reports the fire main was found repaired.
Engineering › Fuel Oil Service System › Piping
Issued 7 October 2004 Resolved
Remove rubber oil drain lines from both main engines. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 7 October 2004 Resolved
Saltwater inlet pipe for freshwater cooling system has numerous holes. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 6 December 2004
Resolution: Received class report.
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 7 October 2004 Resolved
Vessel to remove all epoxy resin patches from fresh water coolers. (SOLAS 60, Chapter I, regulation 11)
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 6 December 2004
Resolution: Received class report.
Electrical › Electric Generation Source (service) › Generator
Issued 7 October 2004 Resolved
Port Generator missing RPM gauge. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 6 December 2004
Resolution: Received class report.
Electrical › Electric Generation Source (service) › Generator
Issued 7 October 2004 Resolved
Port generator saltwater inlet pipe holed and leaking. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Electrical › Electric Generation Source (service) › Generator
Issued 7 October 2004 Resolved
Starboard generator has soft patch on saltwater pipe. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Electrical › Electric Generation Source (service) › Generator
Issued 7 October 2004 Resolved
Exhaust leak on starboard generator. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: PRS reports repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 October 2004 Resolved
Starboard main engine saltwater inlet pipe holed and leaking. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Engineering › Fuel Oil Service System › Pump
Issued 7 October 2004 Resolved
Starboard main engine has fuel leaks on #2, 3, & 4 fuel pumps. (SOLAS 60, Chapter I, Regulation 35)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: PRS reports leaks were found remedied.
Engineering › Fuel Oil Service System › Pump
Issued 7 October 2004 Resolved
Port main engine has fuel leaks on #1, 2, 3, and 5 fuel pumps. (SOLAS 60, Chapter I, Regulation 35)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: PRS reports leaks are repaired.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 7 October 2004 Resolved
Epoxy resin patches on type III MSD holding tank. (33 CFR 159)
Action required: 705 - Other - as specified
Due 21 October 2004
Resolved 6 December 2004
Resolution: Received class report.
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 7 October 2004 Resolved
Fuel leak on emergency fire pump. (SOLAS 60, Chapter I, Regulation 35)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 7 October 2004 Resolved
Exhaust leak on emergency fire pump. (SOLAS 60, Chapter I, Regulation 11)
Action required: 705 - Other - as specified
Resolved 14 October 2004
Resolution: Received class report stating repairs were completed.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 3 December 2003 Resolved
Vsl's port anchor broke and fell into the ocean at the Savannah River Anchorage. Vsl still has operational starboard anchor. Class attended vsl and gave a 30 day extension to replace missing port anchor. Solas 60 CH I Reg 11 LEGACY COMPONENT DESC: Anchor
Condition: Improper/Lack of Maintenance
Due 3 January 2004
Resolved 16 August 2004
Resolution: Received fax from Class stating that the port side anchor was replaced satisfactory.
Documentation › Certificates/Documents
Issued 28 November 2003 Resolved
Minimum Safe Manning Certifcate is for Caribbean Sea ports Only. Vessel is operating outside of Certificate restriction. STCW 95 I/14-1,2. LEGACY COMPONENT DESC: Minimum Safe Manning Document
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2003
Resolved 5 December 2003
Resolution: Vessel was issued a New Safe Manning Certificate form Panama Stating that vessel can engage in voyages between Gulf of Mexico, East coast of USA and Caribean sea ports. also VSL is manned w/ Required Qualified 3rd Engineer.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 November 2003 Resolved
#3 Fuel Injector on starboard main engine fuel line is leaking. Solas 60 CH1 Reg 11 LEGACY COMPONENT DESC: Injector (fuel injection)
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2003
Resolved 28 November 2003
Resolution: Fuel injector leak was fixed and inspected by [name withheld] and found satisfactory.
Engineering › Freshwater System (jacketwater cooling)
Issued 28 November 2003 Resolved
Fresh Water cooling pump on starboard main engine found leaking in way of Mechanical Seal. Solas 60 Ch1/ Reg 11 LEGACY COMPONENT DESC: Reciever
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2003
Resolution: Class report from PRS States that a new Mechanical seal has been put into place and after re-xamination a satisfactory test was conducted.
Documentation › Logs/Records
Issued 28 November 2003 Resolved
Oil record book has almost a two year gap between entries. Vessel is to provide missing oil record books. LEGACY COMPONENT DESC: Oil Record Book
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 December 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 November 2003 Resolved
Vessel is to install jacketed high pressure fuel lines on Main engines. Solas 74amends CHII-2/ Reg 15.2.9
Action required: 17 - Rectify deficiencies prior to departure
Due 28 November 2003
Resolved 5 December 2003
Resolution: Class report From PRS States that Shielded High Pressure fuel oil lines on both main engines have been installed,
Construction/Loadline › Hull
Issued 17 October 2002 Resolved
Noted several large and prominent insets on Port & Starboard Bow. Flag State to attest to condition & repairs if necessary prior to vessel's departure. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2002
Resolution: Shell plating was satifactorlly inspected by Class and temp repairs were made. Permanent repairs to be carried out not later than 30NOV2002.
Engineering › Generator (propulsion-electric)
Issued 17 October 2002 Resolved
Repair numerous fuel oil leaks on Main Engines and #2 Main Generator. Flag State to attest to correction prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2002
Resolution: Class report attesting to the Misc F.O. leaks of Main Engine and Main generators, temporary measure of tightened to stop the weeping. Permanent repairs n.l.t. 30NOV2002.
Documentation › Safety Management System
Issued 17 October 2002 Resolved
Noted no evidence of a Safety Management System aboard vessel. Observed empty ISM binders & Master had no working knowledge of ISM. Flag State to investigate & conduct audit prior to vessel departure. LEGACY COMPONENT DESC: Company Responsibility/Authority Documentation
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2002
Resolution: An initial SMC audit was carried out.
Personnel › Certificates/Documents/Licenses
Issued 17 October 2002 Resolved
Vessel to acquire properly Licensed & Certificated Master and Chief Engineer prior to departure. Flag State to verify that vessel is Manned IAW Minimum Safe Manning Certificate. LEGACY COMPONENT DESC: [name withheld], Chief Engineer
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2002
Resolution: Vessel acquied a new Master and Chief Engineer prior to Departure.
Lifesaving › Embarkation Appliances/Stations
Issued 17 October 2002 Resolved
Noted Embarkation Lighting to not be connected to Emergency source of power. Flag State to attest to correction prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2002
Resolution: Received Class report stating that the Emergency embarkation lights were satifactorlly tested. Polski Rejestr Statkons
Navigation
Issued 15 July 2001 Resolved
CHARTS FOR AREA WERE NOT CORRECTED.
Condition: Unknown
Due 15 July 2001
Resolved 20 July 2001
Accommodation/Occupational Safety
Issued 15 July 2001 Resolved
FOOD STORES IN CREW ACCOMMODATIONS
Condition: Unknown
Due 15 July 2001
Resolved 15 July 2001
Engineering
Issued 15 July 2001 Resolved
LEAKY PACKING GLAND ON #2 DIESEL ENGINE FRESH WATER COOLING PUMP.
Condition: Unknown
Due 15 July 2001
Resolved 20 July 2001
Navigation
Issued 28 August 2000 Resolved
CHARTS FOR NEW YORK AREA NOT CURRENTLY CORRECTED. UPDATE CHARTS FOR AREA PRIOR TO DEPARTING PIER.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Fire Fighting
Issued 28 August 2000 Resolved
CREW UNABLE TO CONDUCT SATISFACTORY FIRE DRILL. CONDUCT SATISFACTORY FIRE DRILL PRIOR TO DEPARTURE NEW YORK.
Condition: Unknown
Due 1 September 2000
Resolved 1 September 2000
Accommodation/Occupational Safety
Issued 28 August 2000 Resolved
ENGINE ROOM HANDRAIL MISSING FROM AROUND CATWALK, GENERATOR DECK (2). INSTALL HAND RAIL AROUND CATWALK PRIOR TO 28SEP00.
Condition: Unknown
Due 8 January 2001
Resolved 8 January 2001
Documentation
Issued 5 March 2000 Resolved
Engineer's license was expired. STCW95 1/4-2.4
Condition: Unknown
Due 5 March 2000
Resolved 11 March 2000
Lifesaving
Issued 5 March 2000 Resolved
Vessel did not have a motorized lifeboat. 60 SOLAS III Reg 8(b)
Condition: Unknown
Due 5 March 2000
Resolved 8 March 2000
Documentation
Issued 5 March 2000 Resolved
Vessel did not have a valid COFR. 33CFR130.1
Condition: Unknown
Due 6 March 2000
Resolved 8 March 2000
Fire Fighting
Issued 5 March 2000 Resolved
Vessel had an old and faded fire control plan.74 SOLAS Ammended II-2 Reg 20
Condition: Unknown
Due 5 April 2000
Resolved 11 March 2000
Lifesaving
Issued 5 March 2000 Resolved
Vessel's SARTS were expired. 74 SOLAS Ammended III Reg 19.2
Condition: Unknown
Due 5 March 2000
Resolved 11 March 2000
Lifesaving
Issued 5 March 2000 Resolved
Vessel's emergency rations were expired. 60 SOLAS III Reg 17 (xvi)
Condition: Unknown
Due 5 March 2000
Resolved 11 March 2000
Unknown
Issued 5 March 2000 Resolved
Vessel was planning 1400 mile voyage. Vessel is restricted to voyages of 600 miles or less with current crew and Safe Manning Certificate._x001C_ 60 SOLAS III Reg 2(a)
Condition: Unknown
Due 5 March 2000
Resolved 11 March 2000
Documentation
Issued 5 March 2000 Resolved
Vessel did not have two licensed radio personnel in accordance with the Safety Radio Telegraphy Certificate.
Condition: Unknown
Due 5 March 2000
Resolved 11 March 2000
Documentation
Issued 21 June 1999 Resolved
MISSING EXEMPTION CERTIFICATE FOR FIXED FIRE FIGHTING IN HOLDS AS REFERRED TO IN THE SAFETY EQUIPMENT CERTIFICATE. PROVIDE CLASS REPORT CONCERING WHEREABOUTS OF EXEMPTION CERTIFICATE PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Accommodation/Occupational Safety
Issued 21 June 1999 Resolved
WATER VALVES IN CREW COMMON HEAD NOT FUNCTIONAL. REPLACE INOPERATIVE VALVESPRIOR TO 21 JULY 99.
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Documentation
Issued 21 June 1999 Resolved
MISSING FOUR MEDICAL CERTIFICATES FOR CREW MEMBERS. PROVIDE MEDICAL CERTIFICATES PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 11 August 1999
Resolved 11 August 1999
Construction/Loadline
Issued 21 June 1999 Resolved
RAIL ON MAIN DECK MISSING. REPLACE LENGTH OF RAIL ON MAIN DECK AFT AND PROVIDE CLASS REPORT PRIOR TO 21JUL99.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Lifesaving
Issued 21 June 1999 Resolved
PORT AND STARBOARD LIFEBOAT DAVITS SHOW HEAVY WASTAGE. PROVIDE CLASS REPORTCONCERNING CONDITION OF DAVITS PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Fire Fighting
Issued 21 June 1999 Resolved
CEMENT PATCH FOUND ON FIRE MAIN FORWARD. REPAIR/ RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Fire Fighting
Issued 21 June 1999 Resolved
VESSEL'S CREW UNFAMILIAR WITH FIREFIGHTING PROCEDURES AND THE PROPER OPERATION OF THE BREATHING APPARATUS. CREW TO COMPLETE SATISFACTORY DRILL AND MAKE ALL EQUIPMENT OPERATIONAL TO THE SATISFACTION OF FLAG STATE.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Lifesaving
Issued 21 June 1999 Resolved
LIFERAFT TIED DOWN AND HYDROSTATIC RELEASE IS OUTDATED. MAKE RAFT FLOAT FREE CAPABLE AND PROVIDE CLASS REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Engineering
Issued 21 June 1999 Resolved
MAIN ENGINE FRESH WATER COOLING PUMP IS LEAKING, REPAIR/ RENEW PRIOR TO 21 JULY 99, PROVIDE CLASS REPORT PRIOR TO DEPARTURE STATING THAT VESSEL IS SEAWORTHY.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Engineering
Issued 21 June 1999 Resolved
REPAIR/ RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURN U.S. WATERS.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Fire Fighting
Issued 21 June 1999 Resolved
EMERGENCY FIRE PUMP LEAKS AT PUMP AND PRIME MOVER HAS FUEL LEAK. REPAIR/ RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURN U.S. WATERS.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Lifesaving
Issued 21 June 1999 Resolved
VESSEL'S LIFEBOATS MISSING THE NOT STENCILED WITH THE REQUIRED INFORMATION.REPAIR/ RENEW AND PROVIDE CLASS REPORT PRIOR TO 21 JULY 99.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Engineering
Issued 21 June 1999 Resolved
SEVERAL FUEL LEAKS FOUND ON THE MAIN ENGINE AND MAIN SERVICE GENERATOR. REPAIR/ RENEW AND PROVIED CLASS REPORT ON ALL FUEL LEAKS PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Documentation
Issued 21 June 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 June 1999
Resolved 25 June 1999
Documentation
Issued 21 June 1999 Resolved
VESSEL HAD AN AB STANDING THE MATE DUTY AND THE COOK WAS STANDING THE O.S. DUTY. VESSEL IS TO REPLACE THESE PEOPLE WITH PERSONS OF THE PROPER RATING PRIOR TO DEPARTURE.
Condition: Unknown
Due 24 June 1999
Resolved 25 June 1999
Construction/Loadline
Issued 21 June 1999 Resolved
EXCESSIVE FUEL OIL IN THE BILGES, CLEAN E/R BILGES PRIOR TO DEPARTURE AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 24 June 1999
Resolved 28 June 1999
Navigation
Issued 6 December 1997 Resolved
MAGNETIC COMPASS NOT CALIBRATED.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Navigation
Issued 6 December 1997 Resolved
ECHO DEPTH SOUNDER NOT FUNCTIONING.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Documentation
Issued 6 December 1997 Resolved
VESSEL NOT MANNED IAW SAFE MANNING DOCUMENT. MISSING 1 DECK OFFICER, 1 ENGINEER OFFICER, AND 2 ABLE SEAMEN. VESSEL DETAINED UNDER SOLAS.
Condition: Unknown
Due 12 February 1998
Resolved 12 February 1998
Lifesaving
Issued 16 June 1997 Resolved
MAKE PROPER LOG ENTRIES IN SHIPS LOG BOOK FOR QUARTERLY LOWERING AND LAUNCHING OF VESSELS LIFEBOATS.
Condition: Unknown
Due 9 December 1997
Resolved 9 December 1997
Navigation
Issued 16 June 1997 Resolved
OBTAIN CURRENT CORRECTIONS FOR LIGHT LIST AND COAST PILOT PUBLICATIONS.
Condition: Unknown
Due 16 June 1997
Resolved 17 June 1997
Documentation
Issued 16 April 1997 Resolved
VESSEL NOT MANNED IAW SAFE MANNING DOCUMENT.
Condition: Unknown
Due 17 April 1997
Resolved 18 April 1997
Unknown
Issued 17 March 1995 Resolved
UPON ARRIVAL AT NEXT U.S. PORT, PROVIDE A UNITED STATE COAST MARINE INSPECTOR WITH RESULTS OF SURVEYORS REPORT AND ANY OUTSTANDING CONDITIONS OF CLASS.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Engineering
Issued 17 March 1995 Resolved
PROVE PROPER OPERATION STARBOARD MAIN DIESEL; #4 CYLINDER IS NOT FUNCTIONING. PROVIDE CLASSIFICATION CERTIFICATES DEMONSTRATING VESSEL'S COMPLIANCE WITH CLASS REQUIREMENTS FOR MACHINERY INCLUDE ANY OUTSTANDING COMMENTS/CONDITION OF CLASS.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Fire Fighting
Issued 17 March 1995 Resolved
Firemain piping port side engine room is holed; crop and renew and hydrostatically test.
Condition: Unknown
Due 23 March 1995
Resolved 27 March 1995
Deck/Cargo
Issued 17 March 1995 Resolved
Anchor washdown branch line in way of paint locker has soft patch. Make proper repairs and hydro test.
Condition: Unknown
Due 23 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 17 March 1995 Resolved
LARGE B-V FIRE EXTINGUISHER IN ENGINE ROOM HAS DETERIORATED HOSE; REPAIR HOSE.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 17 March 1995 Resolved
FIXED CO2 SYSTEM PIPING IS CRIMPED IN WAY OF FORWARD PAINT LOCKER. PROVIDE PROPER PIPING.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Engineering
Issued 17 March 1995 Resolved
REMOTE SHUT DOWNS FOR FUEL OIL SYSTEMS ARE INOP/REMOVED. PROVE PROPER OPERATION OF SHUT DOWNS.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 17 March 1995 Resolved
FIRE HOZE NOZZLES ARE STRAIGHT STREAM TYPE IN ENGINE ROOM; REPLACE WITH COMBINATION TYPE.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 17 March 1995 Resolved
SPOOL PIECE FOR INTAKE MANIFOLD FOR MAIN FIRE PUMP IS LEAKING AND SOFT PATCH. MAKE PROPER REPAIRS.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Engineering
Issued 17 March 1995 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Accommodation/Occupational Safety
Issued 17 March 1995 Resolved
MAKE PROPER REPAIRS TO WASTED POTABLE WATER PIPING
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 17 March 1995 Resolved
BILGE EDUCTOR LINE IN AFTER STEERING SPACE HAS SOFT PATCH. MAKE PROPER REPAIRS.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 17 March 1995 Resolved
PROVIDE FIREFIGHTING SUITS ABOARD VESSEL.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 17 March 1995 Resolved
CROP AND RENEW WASTED FIREMAIN PIPING UP FORWARD IN WAY OF ANCHOR WINDLASS.
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Lifesaving
Issued 17 March 1995 Resolved
REMOVE EXCESSIVE FUEL OIL FROM ENGINE ROOM BILGE AND PROPERLY DISPOSE OF OIL.
Condition: Unknown
Due 23 March 1995
Resolved 28 March 1995
Engineering
Issued 17 March 1995 Resolved
LOCATE SOURCE OF FUEL OIL LEAKS IN ENGINE ROOM
Condition: Unknown
Due 22 March 1995
Resolved 28 March 1995
Electrical
Issued 17 March 1995 Resolved
Provide approved wiring and explosion proof fixture in paint locker.
Condition: Unknown
Due 22 March 1995
Resolved 27 March 1995
Electrical
Issued 17 March 1995 Resolved
Locate and repair grounds on main switchboard in engine room IAW Solas 60.
Condition: Unknown
Due 22 March 1995
Resolved 27 March 1995
Electrical
Issued 17 March 1995 Resolved
Generators on upper engine room flat are inoperative. Prove proper operation.
Condition: Unknown
Due 22 March 1995
Resolved 27 March 1995
Fire Fighting
Issued 17 March 1995 Resolved
Emergency fire pump does not produce sufficient pressure. Repair/replace and demonstrate operation of emergency fire pump.
Condition: Unknown
Due 22 March 1995
Resolved 27 March 1995
Navigation
Issued 17 March 1995 Resolved
REPAIR DISCREPANCY BETWEEN RUDDER ANGLE INDICATOR ON BRIDGE AND STEERING FLAT.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Electrical
Issued 17 March 1995 Resolved
CLEAR ABS REQUIREMENT #1 REGARDING WASTED PORT GENERATOR FLAT.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Engineering
Issued 17 March 1995 Resolved
CLEAR ABS REQUIREMENT #2 REGARDING ENGINE ROOM PUMP FOUNDATIONS.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Engineering
Issued 17 March 1995 Resolved
CLEAR ABS REQUIREMENT #3 REGARDING TEMPORARY REPAIRS TO STARBOARD MAIN ENGINE.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Fire Fighting
Issued 17 March 1995 Resolved
CLEAR ABS REQUIREMENT #5 REGARDING DOUBLER ON FIRE PUMP INTAKE MANIFOLD.
Condition: Unknown
Due 15 June 1995
Resolved 15 June 1995
Navigation
Issued 12 April 1994 Resolved
VESSEL CHART 11361 WAS NOT CURRENTLY CORRECTED.LAST CORRECTION WAS 37/91
Condition: Unknown
Due 15 April 1994
Resolved 13 April 1994
Navigation
Issued 12 April 1994 Resolved
VESSEL'S CHART 11364 WAS NOT CURRENTLY CORRECTED FOR TRANSITEING THE AREA LAST CORRECTION WAS 26/92
Condition: Unknown
Due 15 April 1994
Resolved 13 April 1994
Navigation
Issued 12 April 1994 Resolved
VESSEL WAS MISSING CHART 11370 FOR TRANSITING THE AREA.
Condition: Unknown
Due 15 April 1994
Resolved 13 April 1994
Navigation
Issued 12 April 1994 Resolved
VESSEL FAILED TO HAVE A CURRENTLY CORRECTED COPY OF THE U.S.COAST PILOT _x001C_OR A FOREIGN EQUIVALANT ONBROAD._x001C_
Condition: Unknown
Due 15 April 1994
Resolved 13 April 1994
Navigation
Issued 12 April 1994 Resolved
VESSEL DID NOT HAVE ONBOARD A CURRENTLY CORRECTED COPY OF COAST GUARD LIGHT LIST OR EXTRACT.
Condition: Unknown
Due 15 April 1994
Resolved 13 April 1994
Navigation
Issued 12 April 1994 Resolved
VESSEL TIDE TABLES WERE OUTDATED (1993) AND WERE NOT CURRENTLY CORRECTED
Condition: Unknown
Due 15 April 1994
Resolved 13 April 1994
Navigation
Issued 12 April 1994 Resolved
VESSEL FAILED TO HAVE A CURRENTLY CORRECTED COPY OR APPLICABLE EXTRACT OF TIDAL CURRENT TABLES ONBOARD.
Condition: Unknown
Due 15 April 1994
Resolved 13 April 1994
Engineering
Issued 12 April 1994 Resolved
Place proper flame screens on fuel oil vents on the main deck.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 12 April 1994 Resolved
Place intrinsically safe lighting and wiring to lights in the paint locker.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Electrical
Issued 12 April 1994 Resolved
Install emergency batteries for radio.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Navigation
Issued 12 September 1988 Resolved
VESSEL FAILED TO HAVE ONBOARD A MARINE CHART WITH ENOUGH DETAIL TO MAKE SAFE NAVIGATION OF THE AREA POSSIBLE.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Navigation
Issued 12 September 1988 Resolved
VESSEL FAILED TO HAVE ONBOARD A CURRENT EDITION OF THE TIDAL CURRENT TABLESPUBLISHED BY THE NATIONAL OCEAN SERVICE OR A FOREIGN EQUIVALENT OF THAT PUBLICATION.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Documentation
Issued 26 July 1985 Resolved
33CFR155.750(A)(1): A LIST OF THE PRODUCTS TRANSFERRED TO OR FROM THE VESSEL WAS NOT INCLUDED IN THE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 29 August 1985
Resolved 26 July 1985
Documentation
Issued 26 July 1985 Resolved
33CFR155.750(A)(7)PROCEDURES FOR TOPPING OFF OF THE SHIPS TANKS WAS NOT DESCRIBED IN THE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 29 August 1985
Resolved 26 July 1985
Documentation
Issued 26 July 1985 Resolved
33CFR155.750(A)(2)(III) A DESCRIPTION OF AND PROCEDURES FOR EMPTYING THE DISCHARGE CONTAINMENT SYSTEM WAS NOT DESCRIBED IN THE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 29 August 1985
Resolved 26 July 1985
Documentation
Issued 26 July 1985 Resolved
33CFR155.750(A)(2)(II)THE LOCATION OF THE SHUTOFF VALVE OR OTHER ISOLATION DEVICE THAT SEPARATES ANY BILGE OR BALLAST SYSTEM FROM THE OIL TRANSFER SYSTEM WAS NOT DESCRIBED IN THE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 29 August 1985
Resolved 26 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.