Records in 2016. Most recent: operational control imposed, 17 March 2016.
Documentation › Certificates/Documents › Certificate of Fitness (GC Code)
Issued 17 March 2016
Resolved
Prior to conducting cargo - 17 abc - An international Certificate of Fitness for the Carriage of Liquid Gases in Bulk shall be issued after an initial or periodical survey and be on board for inspection at all times. The COF does not list any authorized cargoes.
74SOLAS(14) VII/13
IGC 1.5.4
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2016
Resolved 18 March 2016
Resolution: Proper COF issued w/cargoes.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 17 March 2016
Resolved
Prior to cargo ops. 17abc -The condition of the ship and its equipment shall be maintained to ensure the ship in all respects will remain fit to proceed to sea without danger to the crew or ship. There is two to three inches of fuel oil in the machinery space bilge. 74SOLAS(14) I/11
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2016
Resolved 18 March 2016
Resolution: Machinery bilge cleaned.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 17 March 2016
Resolved
Prior to cargo ops - 17abc - A sufficient quantity of dry chemical powder should be stored to provide a minimum 45 second discharge time for the cargo deck fixed firefighting system. A firefighting service report from Drew Marine indicates all pressure regulators on dry chemical N2 fixed firefighting system are faulty.
74SOLAS(14) VII/13
IGC 11.4.6
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 March 2016
Resolution: Satisfactory 3rd party cert attesting to replacement of N2 regulating valves received, dry chem room walked and found sat.
Construction/Loadline › Structures › Door
Issued 17 March 2016
Resolved
Doors to and from airlocks should be self-closing. The outer motor room door does not self-close, making the airlock between the gas dangerous cargo deck and the gas safe motor room defective.
74SOLAS(14) VII/13
IGC 3.6.2
Action required: 705 - Other - as specified
Resolved 18 March 2016
Resolution: Self closing door works.
Communications › Alarms/Indicators › Fire Alarm
Issued 17 March 2016
Resolved
Detained 30abc - The audible and visual alarm system should be provided to indicate if more than one door is moved from the closed position. There are no audible alarms when both doors are open. 74SOLAS(14) VII/13
IGC 3.6.3
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2016
Resolution: Audible alarm works.
Lifesaving › Rescue Boat › Construction
Issued 17 March 2016
Resolved
Rescue boats shall be stowed in a state of continuous readiness for launching in not more than 5 minutes and recovered in not more than 5 minutes. There is no rescue boat davit winch installed. The freefall lifeboat was designated as the rescue boat. There is no alternate way to retrieve the rescue boat or freefall lifeboat within 5 minutes.
74SOLAS(14) III/14, 17
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 20 March 2016
Resolution: Witnessed satisfactory launching and recovery of rescue boat.
Deck/Cargo › Cargo Stowage › General
Issued 17 March 2016
Resolved
The changing of the safety relief valves shall be carried out under the supervision of the master in accordance with procedures approved by the Administration and specified in the ship's operating manual. The ship does not have procedures detailing how to change the safety relief valve setting. 74SOLAS(14) VII/13
IGC 8.2.6
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 March 2016
Resolution: Procedures approved by class were provided.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 17 March 2016
Resolved
Prior to departure - 17abc - Based on the above eight deficiencies identified during the exam, the COTP recommends an external ISM audit be conducted prior to departure. 74SOLAS(14) IX/3
ISM 1.4
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 March 2016
Resolution: Class completed external audit. Cannot release draft copy until Class HQ reviews and approves.