MAURY USCG vessel records Sign in
← All vessels

PECAN

PECAN is a 1971 freight ship. The Coast Guard has recorded 10 inspections since 1985, most recently in June 1998, along with 17 deficiencies.

Records from 1985 to 1998. Most recent: inspection, 23 June 1998.

Built
1971
Last inspected
23 June 1998
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7038226 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222184
Flag
PANAMA
—
Maury page id
psix-222184

Inspections, by type

…with no type recorded10
Years with a record 7 calendar years (1985–1998)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8068 - Regulatory (Subpart C or D), Gross Ton
8360 - Convention (Subpart B), Gross Ton
4816 - Regulatory (Subpart C or D), Net Ton
4621 - Convention (Subpart B), Net Ton
9876 - Dead Weight, Ton
5330 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 10

23 June 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 416791
15 May 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 415848
29 October 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396800
19 March 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 376324
15 January 1995 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 374217
5 April 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 357183
4 January 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 341162
16 September 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 311468
6 November 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 305238
17 October 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 304875

Deficiency record · 17

Electrical
Issued 15 May 1998 Resolved
PERMANENTLY REPAIR EXHAUST LEAK ON EMERGENCY GENERATOR. CORRECT TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO 14 JUNE 1998.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Electrical
Issued 15 May 1998 Resolved
PERMANENTLY REPAIR ELECTRICAL WIRING AT JUNCTION BOX ABOVE STEERING GEAR._x001C_ CORRECT TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO 14 JUNE 1998.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Construction/Loadline
Issued 15 May 1998 Resolved
PAINT IN CONTRASTING COLOR SHIP'S LOADLINE. CORRECT TO THE SATISFACTION OF CLASS SOCIETY PRIOR TO 14 JUNE 1998.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Lifesaving
Issued 15 May 1998 Resolved
PROVIDE PROPER RECOVERY OF LIFEBOAT FROM WATER TO CRADLE. TO THE SATISFACTION OF CLASS. IAW SOLAS 60/III REG 36(K).
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Lifesaving
Issued 29 October 1996 Resolved
PRIOR TO NEXT U.S. PORT, REPLACE MISSING PORTSIDE LIFEBOAT STEERING OAR. TOSATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. SOLAS 60, III REG 11.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Lifesaving
Issued 29 October 1996 Resolved
PRIOR TO NEXT U.S. PORT, MAKE BOTH LIFEBOAT ENGINE CASINGS FIRE RESISTANT TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. SOLAS 60, CHAP III, REG.9
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Lifesaving
Issued 29 October 1996 Resolved
PRIOR TO NEXT U.S. PORT, REPAIR/REPLACE PORTSIDE LIFEBOAT THWART SEATS TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. SOLAS 60, CHAP.III, REG.5_x001C_
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 29 October 1996 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE PERSONNEL SAFETY GUARDS FOR EMERGENCY FIREPUMP FANS/ROTATING MACHINERY TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. ILO 147
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Engineering
Issued 29 October 1996 Resolved
PRIOR TO NEXT U.S. PORT, REPLACE LEAKING O-RINGS IN LEAKING FUEL SERVICE BOOSTER PUMP PRESSURE GAUGE TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. ILO 147
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Fire Fighting
Issued 29 October 1996 Resolved
PRIOR TO NEXT U.S. PORT, PROVIDE INSTALLED FIXED FIRE FIGHTING SYSTEM IN PAINT LOCKER TO SATISFACTION OF CLASS SOCIETY. PROVIDE SATISFACTORY SURVEYOR'S REPORT TO LOCAL COAST GUARD. SOLAS 74/78 II-2 REG 18.
Condition: Unknown
Due 18 December 1996
Resolved 18 December 1996
Navigation
Issued 15 January 1995 Resolved
provide shaft cover for STBD Steering Gear Pump Motor.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Lifesaving
Issued 15 January 1995 Resolved
remove excess oil from steering gear space.
Condition: Unknown
Due 20 March 1995
Resolved 20 March 1995
Navigation
Issued 5 April 1993 Resolved
A VIO OF 33 C.F.R. 164.33(a)(1)(ii) IN THAT CHARTS 12221, 12222, 12245, 12248, 12251, 12251,12253, ONBOARD THE VESSEL WERE NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 6 April 1993
Resolved 13 April 1993
Navigation
Issued 5 April 1993 Resolved
A VIO OF 33 C.F.R. 164.33(a)(2)(i) IN THAT THERE WAS NO U. S. COAST PILOT PUBLICATION ON BOARD.
Condition: Unknown
Due 6 April 1993
Resolved 13 April 1993
Navigation
Issued 5 April 1993 Resolved
A VIO OF 33 C.F.R. 164.33(a)(2)(ii) IN THAT THE LIGHT LIST PUBLICATION WAS NOT ONBOARD.
Condition: Unknown
Due 6 April 1993
Resolved 13 April 1993
Navigation
Issued 16 September 1986 Resolved
CHART 12333,12334 AND 12349 ONBOARD NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 17 September 1986
Resolved 16 September 1986
Navigation
Issued 17 October 1985 Resolved
CHART NOS 18720 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 17 October 1985
Resolved 17 October 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.