MAURY USCG vessel records Sign in
← All vessels

SHOTA

SHOTA is a 1970 tank ship. The Coast Guard has recorded 7 inspections since 1989, most recently in August 1992, along with 20 deficiencies.

Records from 1989 to 1992. Most recent: inspection, 11 August 1992.

Built
1970
Last inspected
11 August 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7040891 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222211
Flag
SOVIET UNION
—
Maury page id
psix-222211

Inspections, by type

…with no type recorded4
Years with a record 2 calendar years (1989–1992)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10814 - Regulatory (Subpart C or D), Gross Ton
5671 - Regulatory (Subpart C or D), Net Ton
16540 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 7

11 August 1992 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 354423
11 August 1992 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831628
3 July 1992 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1470864
1 July 1992 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 351702
21 November 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333806
25 June 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 463155
24 June 1989 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1202608

Deficiency record · 20

Fire Fighting
Issued 11 August 1992 Resolved
VSL'S FIRMAIN ISOLATION VALVE IN VICINITY OF #3 COT IS FROZEN.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992 Resolved
VESSEL HAS A SOFT PATCH LOCATED ON THE FIREMAIN A VIOLATION OF SOLAS II-2 REG. 4
Condition: Unknown
Due 11 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992 Resolved
VESSEL DID NOT HAVE AN ANNUAL FOAM ANALYSIS A VIOLATION OF 46 C.F.R. 34.20-10.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992 Resolved
VESSEL'S FIRE PLAN DOES NOT REFLECT TRUE LOCATION OF FIREMAN'S SUITS A VIOLATION OF SOLAS II-2 REG. 20.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992 Resolved
VSL HAS SOFT PATCHES AT FIRE STATIONS ON THE PORT AND STRBD SIDES OF THE MAIN DECK JUST FWD OF DECKHOUSE.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992 Resolved
MAKE PERMINENT REPAIRS TO FIREMAIN IN WAY OF SOFT PATCH, NEAR THE HOUSE AREA FORWARD OF CARGO MAINIFOLD. (SOLAS CHAPTER II-2, REG.4)
Condition: Unknown
Due 11 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 11 August 1992 Resolved
UPDATE THE FIRE PLAN TO REFLECT THE TRUE LOCATION OF FIREMAN'S SUITS._x001C_ (SOLAS CHAPTER II-2 REG 20)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 11 August 1992 Resolved
MAKE PERMINENT REPAIRS TO THE FIRE STATIONS PORT/STBD SIDE ON MAIN DECK JUST FORWARD OF DECK HOUSE IN WAY OF THE EXISTING SOFT PATCHES._x001C_ (SOLAS CHAPTER II-2 REG 4)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 11 August 1992 Resolved
MAKE PERMINENT REPARIS TO THE FROZEN FIREMAIN ISOLATION VALVE IN VICINITY OF #3 COT. (SOLAS CHAPTER II-2 PART A REG 4)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Deck/Cargo
Issued 11 August 1992 Resolved
UPDATE VESSEL'S OIL TRANSFER PROCEDURES TO COMPLY WITH 33 CFR 155.750.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992 Resolved
CONDUCT ANNUAL FOAM ANALYSIS NO LATER THAN 30 SEPTEMBER 1992 AND PROVIDE A COPY OF THE RESULTS TO THE COAST GUARD. (46 CFR SECTION 34.20-10)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 3 July 1992 Resolved
Provide documentation from Class Society (Bureau Veritras) stating that theemergency fire pump can take suction from sea water while vessel is all conditions of list and trim prior to transfer at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Deck/Cargo
Issued 3 July 1992 Resolved
Provide plugs which have a mechanical means of closure for all cargo and fuel containment areas IAW 33 CFR 155.310 prior to transfer operations at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Navigation
Issued 3 July 1992 Resolved
Permanently mount, on bridge and in steering room, simple operating instructions with block diagram showing steering gear change over IAW SOLAS74 Chapter V, Reg. 19-2 at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Documentation
Issued 3 July 1992 Resolved
Provide certificates of competentcy for all officers from flag state at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Construction/Loadline
Issued 3 July 1992 Resolved
Make a ballast tank gas free, using a certified marine chemist, and available for internal exam by U.S. Coast Guard at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Deck/Cargo
Issued 3 July 1992 Resolved
Make permanent repairs to starboard vent mast flame screen framework so that flame screen can be properly installed prior to transfer at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Fire Fighting
Issued 1 July 1992 Resolved
NUMEROUS FIRE HOSES LEAKING WHICH REQUIRE REPLACEMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 July 1992
Resolved 4 July 1992
Documentation
Issued 1 July 1992 Resolved
VESSEL'S OIL TRANSFER PROCEDURES INCOMPLETE AS PER 33 C.F.R. 155.750_x001C_ PROCEDURES TO BE COMPLETED BY NEXT U.S. PORT CALL.
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992
Fire Fighting
Issued 1 July 1992 Resolved
VESSEL'S EMERGENCY FIRE PUMP COULD NOT BE TESTED DUE TO VESSEL'S HIGH DRAFTEMERGENCY FIRE PUMP TO BE TESTED AT NEXT U.S. PORT CALL._x001C_
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.