Records from 1989 to 1992. Most recent: inspection, 11 August 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
11 August 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 354423
11 August 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 831628
3 July 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1470864
1 July 1992
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 351702
21 November 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 333806
25 June 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 463155
24 June 1989
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1202608
Fire Fighting
Issued 11 August 1992
Resolved
VSL'S FIRMAIN ISOLATION VALVE IN VICINITY OF #3 COT IS FROZEN.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992
Resolved
VESSEL HAS A SOFT PATCH LOCATED ON THE FIREMAIN A VIOLATION OF SOLAS II-2 REG. 4
Condition: Unknown
Due 11 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992
Resolved
VESSEL DID NOT HAVE AN ANNUAL FOAM ANALYSIS A VIOLATION OF 46 C.F.R. 34.20-10.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992
Resolved
VESSEL'S FIRE PLAN DOES NOT REFLECT TRUE LOCATION OF FIREMAN'S SUITS A VIOLATION OF SOLAS II-2 REG. 20.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992
Resolved
VSL HAS SOFT PATCHES AT FIRE STATIONS ON THE PORT AND STRBD SIDES OF THE MAIN DECK JUST FWD OF DECKHOUSE.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992
Resolved
MAKE PERMINENT REPAIRS TO FIREMAIN IN WAY OF SOFT PATCH, NEAR THE HOUSE AREA FORWARD OF CARGO MAINIFOLD. (SOLAS CHAPTER II-2, REG.4)
Condition: Unknown
Due 11 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 11 August 1992
Resolved
UPDATE THE FIRE PLAN TO REFLECT THE TRUE LOCATION OF FIREMAN'S SUITS._x001C_ (SOLAS CHAPTER II-2 REG 20)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 11 August 1992
Resolved
MAKE PERMINENT REPAIRS TO THE FIRE STATIONS PORT/STBD SIDE ON MAIN DECK JUST FORWARD OF DECK HOUSE IN WAY OF THE EXISTING SOFT PATCHES._x001C_ (SOLAS CHAPTER II-2 REG 4)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 11 August 1992
Resolved
MAKE PERMINENT REPARIS TO THE FROZEN FIREMAIN ISOLATION VALVE IN VICINITY OF #3 COT. (SOLAS CHAPTER II-2 PART A REG 4)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Deck/Cargo
Issued 11 August 1992
Resolved
UPDATE VESSEL'S OIL TRANSFER PROCEDURES TO COMPLY WITH 33 CFR 155.750.
Condition: Unknown
Due 30 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 August 1992
Resolved
CONDUCT ANNUAL FOAM ANALYSIS NO LATER THAN 30 SEPTEMBER 1992 AND PROVIDE A COPY OF THE RESULTS TO THE COAST GUARD. (46 CFR SECTION 34.20-10)
Condition: Unknown
Due 30 September 1992
Resolved 7 January 1993
Fire Fighting
Issued 3 July 1992
Resolved
Provide documentation from Class Society (Bureau Veritras) stating that theemergency fire pump can take suction from sea water while vessel is all conditions of list and trim prior to transfer at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Deck/Cargo
Issued 3 July 1992
Resolved
Provide plugs which have a mechanical means of closure for all cargo and fuel containment areas IAW 33 CFR 155.310 prior to transfer operations at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Navigation
Issued 3 July 1992
Resolved
Permanently mount, on bridge and in steering room, simple operating instructions with block diagram showing steering gear change over IAW SOLAS74 Chapter V, Reg. 19-2 at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Documentation
Issued 3 July 1992
Resolved
Provide certificates of competentcy for all officers from flag state at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Construction/Loadline
Issued 3 July 1992
Resolved
Make a ballast tank gas free, using a certified marine chemist, and available for internal exam by U.S. Coast Guard at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Deck/Cargo
Issued 3 July 1992
Resolved
Make permanent repairs to starboard vent mast flame screen framework so that flame screen can be properly installed prior to transfer at next U.S. port.
Condition: Unknown
Due 3 July 1992
Resolved 3 July 1992
Fire Fighting
Issued 1 July 1992
Resolved
NUMEROUS FIRE HOSES LEAKING WHICH REQUIRE REPLACEMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 July 1992
Resolved 4 July 1992
Documentation
Issued 1 July 1992
Resolved
VESSEL'S OIL TRANSFER PROCEDURES INCOMPLETE AS PER 33 C.F.R. 155.750_x001C_ PROCEDURES TO BE COMPLETED BY NEXT U.S. PORT CALL.
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992
Fire Fighting
Issued 1 July 1992
Resolved
VESSEL'S EMERGENCY FIRE PUMP COULD NOT BE TESTED DUE TO VESSEL'S HIGH DRAFTEMERGENCY FIRE PUMP TO BE TESTED AT NEXT U.S. PORT CALL._x001C_
Condition: Unknown
Due 12 November 1992
Resolved 12 November 1992