Records from 1985 to 2002. Most recent: inspection, 9 January 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
9 January 2002
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1477084
9 January 2002
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1477091
29 October 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 641689
23 October 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 294931
2 October 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1075492
18 September 2001
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 293843
18 September 1989
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1037083
18 September 1989
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1345439
10 September 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 332553
3 May 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 475709
16 October 1985
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 998069
13 October 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 304716
2 August 1985
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 303461
18 June 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 303849
30 May 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 503035
Navigation
Issued 18 September 2001
Resolved
REPAIR OR REPLACE STEERING GEAR TO MEET THE REQUIREMENTS OF SOLAS 74 AMENDED CHAPTER II-1/29.19.1._x001C_ CLASS REPORT REQUIRED PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 18 October 2001
Resolved 9 January 2002
Resolution: Administratively closed due to age of deficiencies.
Lifesaving
Issued 18 September 2001
Resolved
PROVIDE CLASS REPORT APPROVING TEMPORARY REPAIR TO STARBOARD LIFEBOAT._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Lifesaving
Issued 18 September 2001
Resolved
REPAIR PORT SIDE LIFEBOAT BRAKE HANDLE._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Lifesaving
Issued 18 September 2001
Resolved
REPAIR CRACK IN KEEL OF STARBOARD LIFEBOAT._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Documentation
Issued 18 September 2001
Resolved
VESSEL FAILED TO COMPLY WITH THE REQUIREMENTS OF SOLAS 74 AMENDED CH. IX. VESSEL IS REQUIRED TO COMPLETE EXTERNAL AUDIT OF THE SMS WITHIN 72 HOURS.
Condition: Unknown
Due 21 September 2001
Resolved 4 October 2001
Accommodation/Occupational Safety
Issued 18 September 2001
Resolved
PROVIDE AUTHORIZATION FOR TEMPORARY REPAIRS TO BULKHEAD IN SEWAGE TREATMENTPLANT SPACE._x001C_ CLASS REPORT REQUIRED WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Accommodation/Occupational Safety
Issued 18 September 2001
Resolved
REPAIR WASTED SEWAGE LINE IN SPACE 1 DECK ABOVE MSD II._x001C_ CORRECT PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Electrical
Issued 18 September 2001
Resolved
REPAIR #2 GENERATOR, SUSPECT BURNT INTAKE VALVE, COMPRESSION BACKFIRING THROUGH TURBO INTAKE._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
REPAIR MAIN ENGINE SCAVENGING AIR SYSTEM, EXCESIVE LUBE OIL IN SYSTEM SEAPING FROM ALL GASKET JOINTS._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
PROVIDE SMALL DISCHARGE CONTAINMENT FOR LUBE OIL VENTS ON PORT AND STARBOARD AFT._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Lifesaving
Issued 18 September 2001
Resolved
REMOVE STRING HOLDING ACETYLENE BOTTLES AND PROVIDE BRACKETS._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Construction/Loadline
Issued 18 September 2001
Resolved
PROVIDE CLASS APPROVAL FOR TEMPORARY REPAIR IN PAINT LOCKER. INSERT WAS WELDED ON ONE SIDE ONLY._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
PROVIDE PLUGS FOR SMALL DISCHARGE CONTAINMENT PORT AND STARBOARD FORWARD._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
REPAIR STEAM LINE AMIDSHIPS. PIPE HAS BEEN REPAIRED WITH A DOUBLER WHICH HAS WASTED AWAY._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Navigation
Issued 18 September 2001
Resolved
#1 STEERING GEAR PUMP FAILS TO GO STARBOARD._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
WASTED LUBE OIL LINE ON MAIN ENGINE AT ALL CORNER ELBOW JOINTS._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
REPAIR FUEL LINE FEEDING HIGH PRESSURE PUMP ON MAIN ENGINE._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Navigation
Issued 18 September 2001
Resolved
STEERING GEAR RETURNING TO AMIDSHIPS WHEN OPERATING IN EMERGENCY._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
REPAIR WASTED/LEAKING STEAM PIPE IN STEAM RE-HEATER._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Navigation
Issued 18 September 2001
Resolved
INSTALL INDICATOR FOR STEERING GEAR PUMPS WHEN IN OPERATION._x001C_ CORRECT WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 2001
Resolved 9 January 2002
Resolution: Administratively closed due to age of deficiencies.
Engineering
Issued 18 September 2001
Resolved
REPAIR PACKING GLANDS ON EVAPORATOR WATER PUMP._x001C_ CORRECT WITHIN 30 DAYS
Condition: Unknown
Due 18 October 2001
Resolved 9 January 2002
Resolution: Administratively closed due to age of deficiencies.
Accommodation/Occupational Safety
Issued 18 September 2001
Resolved
REPAIR AERATING PUMP FOR SEWAGE TREATMENT PLANT._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Electrical
Issued 18 September 2001
Resolved
MISSING NON CONDUCTIVE RUBBER MATTING IN FRONT OF THE FOLLOWING ELECTRICAL PANELS: EMERGENCY FIRE PUMP CONTROL ROOM, BILGE CONDENSATION PANEL, PURIFIER ROOM PANEL, COMPRESSOR PANEL, HYDRO FRESH WATER PANEL, BOS'N HOLE STARBOARD BOW. CORRECT WITHIN 30 DAYS
Condition: Unknown
Due 18 October 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
OILY WATER SEPARATOR FAILS TO DRAW SUCTION._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Engineering
Issued 18 September 2001
Resolved
PROVIDE CLASS APPROVAL FOR TEMPORARY REPAIR TO STEAM PIPE IN STARBOARD FORWARD STORAGE SPACE._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Lifesaving
Issued 18 September 2001
Resolved
REPAIR DAMAGED GRAB RAIL AND RUDDER ON STARBOARD LIFE BOAT._x001C_ CLASS REPORT REQUIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 19 September 2001
Resolved 4 October 2001
Navigation
Issued 10 September 1989
Resolved
VESSEL HAD A 1989 EDITION BRITISH ADMIRALTY COAST PILOT ON BOARD NOT CORRECTED UP TO DATE THROUGH THE LATEST NOTICE TO MARINERS.
Condition: Unknown
Due 4 October 2001
Resolved 4 October 2001
Deck/Cargo
Issued 13 October 1985
Resolved
MAKE PERMANENT REPAIRS TO #4 CARGO PUMPS VACCUM LINE. (LOCATED ON THE SECOND LEVEL OF THE PUMP ROOM)
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 13 October 1985
Resolved
REPLACE MECHANICAL SEAL ON #1 CARGO PUMP.
Condition: Unknown
Due 13 October 1985
Resolved 13 October 1985
Deck/Cargo
Issued 18 June 1985
Resolved
REPAIR HOLE IN DISCHARGE LINE ABOVE BUTTERFLY VALVE AT #1 CARGO PUMP.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Deck/Cargo
Issued 18 June 1985
Resolved
REPAIR EXCESSIVE LEAK IN #2 CARGO PUMP.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Deck/Cargo
Issued 18 June 1985
Resolved
HOLE IN DISCHARGE LINE BELOW THE BRANCH AT #3 CARGO PUMP.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Deck/Cargo
Issued 18 June 1985
Resolved
HOLE IN THE OVERBOARD BALLAST DISCHARGE LINE LEADING FROM #4 CARGO PUMP.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985