← All vessels
MORILLO
MORILLO is a 1971 freight ship. The Coast Guard has recorded 21 inspections since 1984, most recently in October 2007, along with 42 deficiencies — 11 with no resolution recorded — and 2 operational controls.
Records from 1984 to 2007. Most recent: inspection, 15 October 2007.
- Built
- 1971
- Last inspected
- 15 October 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 42 recorded · 11 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7105031 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
E5U2128
222338
Flag
COOK ISLANDS
—
Maury page id
psix-222338
Inspections, by type
…with no type recorded15
…past their stated due date9
Years with a record
13 calendar years (1984–2007)
The 21 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9983 - Regulatory (Subpart C or D), Gross Ton
5672 - Regulatory (Subpart C or D), Net Ton
10800 - Dead Weight, Ton
5672 - Regulatory (Subpart C or D), Net Ton
10800 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 21
15 October 2007
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3080540
28 September 2007
MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3064712
20 October 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2804446
20 December 2002
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1721672
19 January 2002
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1485094
8 January 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1474779
31 January 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286822
23 January 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286328
24 January 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 274053
19 March 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 388955
22 January 1996
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 386809
20 November 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 384931
20 November 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 715816
21 February 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348928
17 October 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 339830
16 April 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 521733
7 August 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 331900
25 July 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 331684
22 August 1988
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 325213
9 April 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 301338
18 December 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 299550
Deficiency record · 42
Construction/Loadline › Hull › Transverse Frame
Issued 28 September 2007
Resolved
Hull, Port side vicinity of Frame 83- Indent from previous port, crew conducted repairs but repairs were not checked by class society. Vessel to have class verify repairs prior to departure.
Fire Fighting › Emergency Fire Pumps
Issued 8 January 2002
No resolution recorded
Main and Emergency fire pumps are inoperable. Bearings and seals are wasted. Prior to departing the Port of Pascagoula and conduction cargo operations repair both pumps to the satisfaction of Flag/Class and U.S. Coast Guard. (Solas 60 - Reg 6.5)
Engineering › Sea-water System (primary cooling)
Issued 8 January 2002
No resolution recorded
#1 and #2 MDE S/W Pumps are leaking excessively and seals are worn. Repair to the satisfaction of Flag/Class before 18JAN02. LEGACY COMPONENT DESC: Pump
Engineering › Sea-water System (primary cooling)
Issued 8 January 2002
No resolution recorded
#4 ship service generator S/W colling valve to lube oil cooler is leaking. Seal is bad. Repair to the satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Valve
Lifesaving › Inflatable Liferafts
Issued 8 January 2002
No resolution recorded
Provide Life Saving servicing reports prior to departing Port of Pascagoula to U.S. Coast Guard
Engineering › Diesel Engine (propulsion-electric)
Issued 8 January 2002
No resolution recorded
#2 MDE return line STBD/outboard flange is leaking. Repair to the satisfaction of Flag/Class NLT 18January02.
Engineering › Generator (propulsion-electric)
Issued 8 January 2002
No resolution recorded
#3 ship service generator has exhaust leak (bottom level). Repair to the satisfaction of Flag/ Class NLT 18January, 2002. LEGACY COMPONENT DESC: Exhaust
Engineering
Issued 8 January 2002
No resolution recorded
Provide insulation on all exhaust piping as 2nd and 3rd level in engine room. Repair to the satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Exhaust Piping
Engineering
Issued 8 January 2002
No resolution recorded
S/W supply valve to lower level Port side Bilge/Ballast pump is leaking and seal is worn. Repair to the Satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Supply valve/Bilge Ballast Pump
Engineering › Bilge Water Management System
Issued 8 January 2002
No resolution recorded
Discharge Flange on Bilge/Ballast Pump lower level Port side is leaking excessively. Repair to the Satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Discharge Flange
Electrical › Electric Supply System (service)
Issued 8 January 2002
No resolution recorded
Provide non-conductive material/matting at 440 power panel for reefer system. Provide NLT 18January02. (Solas 60 II/27 (a)) LEGACY COMPONENT DESC: 440 Power Panel
Pollution Prevention/Response › Prevention Equipment
Issued 8 January 2002
No resolution recorded
Provide Mechanical means of closing all containment areas. Repair to satisfaction of Flag/Class NLT 18January02.
(33CFR155.310) LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Construction/Loadline
Issued 31 January 2001
Resolved
CLASS TO PROVIDE REPORT ATTESTING TO REPAIRS TO THE PORT SIDE BOW FORWARD OF THE COLLISION BULKHEAD, DAMAGES WERE SUSTAINED DURING A COLLISION WITH ABARGE ON 31JAN01. CORRECT PRIOR TO VESSEL'S DEPARTURE FROM THE PORT OF PENSACOLA, FLORIDA.
Pollution Prevention/Response
Issued 23 January 2001
Resolved
Marine Sanitation device has numerous holes in plating and pinhole leak in discharge piping. (33 CFR 159.7) Make permanent repairs to the satisfaction of the attending marine inspector.
Engineering
Issued 23 January 2001
Resolved
Excessive leakage from fuel oil purifier for generators (SOLAS 60 I/10): Repair prior to departure to the satisfaction of certificate issueing authority.
Engineering
Issued 23 January 2001
Resolved
Excessive oil in bilges, decks, ladders (SOLAS 60 I/10) Clean and remove oil to satisfaction of certificate issueing authority.
Engineering
Issued 23 January 2001
Resolved
Excessive leaks from lube oil system into each cylinder on MDE. SOLAS 60 I/10): Repair prior to departure to the satisfaction of the safety construction certificate issueing authority.
Lifesaving
Issued 23 January 2001
Resolved
Missing Retro reflective tape on hull of both life boats (SOLAS 74 AMN III/Reg 30.2.7) Replace.
Electrical
Issued 23 January 2001
Resolved
Electrical panel boxes in crane towers missing covers (SOLAS 60 II/REG 27(a)(i)(1); Install covers.
Engineering
Issued 23 January 2001
Resolved
Wasted fuel oil vent cover stbd side aft (33 CFR 155.320); Repair to the satisfaction of the certificate(s) issuing authority.
Electrical
Issued 23 January 2001
Resolved
Oil leaks around cylinder heads on #4 ships service generator (SOLAS 60 I/11); Repair to the satisfaction of the certificate(s) issueing authority.
Lifesaving
Issued 23 January 2001
Resolved
missing and loose beckets on port lifeboat (60SOLAS III/Reg 8); Repair/replace to the satisfaction of the certificate(s) issueing authority
Electrical
Issued 23 January 2001
Resolved
Paint locker explosion proof light missing screws (SOLAS 60 II/27) Relace to the satisfaction of the certificate(s) issueing athority.
Unknown
Issued 23 January 2001
Resolved
lagging on fire pump exhaust flammable natural fiber (cotton) (SOLAS 74 AMNII-2/21); remove flammable lagging to the satisfaction of the certificate(s) issueing authority
Engineering
Issued 23 January 2001
Resolved
Excessive oil on deck of emergency fire pump & steering gear spac (SOLAS 60I/11); Clean to the satisfaction of the certificate(s) issueing authority.
Construction/Loadline
Issued 23 January 2001
Resolved
Stbd aft weld Deteriorated on bulwark (ILLC 66 Annex I/15): repair, replaceto satisfaction of certificate issueing authority.
Engineering
Issued 23 January 2001
Resolved
Excessive fuel oil leaks on all ships service generators (SOLAS 60 I/11): Repair to the satisfaction of class prior to departing the Port of Houston.
Engineering
Issued 23 January 2001
Resolved
Excessive fuel oil leak in #6 cylinder from MDE (SOLAS 60 I/11): Repair to the satisfaction of class prior to departing the Port of Houston.
Deck/Cargo
Issued 23 January 2001
Resolved
Overfill containmnet missing plugs thru out vessel. (33CFR 155.320 (b) Replace to the satisfaction of the attending marine inspector.
Electrical
Issued 23 January 2001
Resolved
Numerous explosion proof light covers cracked in engine room (SOLAS 74 AMNDCH II/REG 27) Repair/replace to satisfaction of the safety construction certificate issueing authority.
Lifesaving
Issued 24 January 2000
Resolved
PRIOR TO DEPARTURE CLEAR DEBRIS IN THE PUMP ROOMS LOCATED ON DECK WHICH IS CREATING A FIRE HAZARD.
Lifesaving
Issued 24 January 2000
Resolved
PRIOR TO DEPARTURE REMOVE TIES OF ALL LIFERAFTS.
Documentation
Issued 24 January 2000
Resolved
PRIOR TO DEPARTURE PROVIDE COPIES OF THE CERTIFICATE OF REGISTRY AND COFR.
Construction/Loadline
Issued 24 January 2000
Resolved
MARK VESSEL'S LOADLINE IN ACCORDANCE WITH THE LOADLINE CERTIFICATE AND PROVIDE CLASS REPORT ATTESTING TO PROPER MARKING PRIOR TO 24FEB00._x001C_
Engineering
Issued 24 January 2000
Resolved
OILY WATER SEPARATOR SHOWING EXCESSIVE LEAKAGE. PROVIDE CLASS REPORT ATTESTING TO PROPER OPERATION PRIOR TO 24FEB00.
Fire Fighting
Issued 24 January 2000
Resolved
PROVIDE CLASS REPORT ADDRESSING POSITION OF FIXED CO2 BOTTLES. BOTTLES ARE RESTING ON THE DECK AND ARE SHOWING SIGNS OF RUSTING. PRIOR TO 24FEB00.
Fire Fighting
Issued 24 January 2000
Resolved
PRIOR TO DEPARTURE REMOVE PORTABLE EXTINGUISHERS STOWED IN CO2 ROOM.
Navigation
Issued 20 November 1995
Resolved
BLOCK DIAGRAM MISSING FROM REMOTE STEERING GEAR CHANGE OVER PROCEDURES._x001C_ VESSEL HAS A PICTURE OF THE UNIT ON THE PROCEDURES IN LIEU OF BLOCK DIAGRAMOF THE UINT ON THE BRIDGE IAW 33 C.F.R. 164.35(K)._x001C_
Electrical
Issued 20 November 1995
Resolved
PROVIDE LIGHT COVERS FOR LIGHTS IN ENGINE ROOM AND CARPENTRY SHOP LOCATED_x001C_ ON MAIN DECK IAW SOLAS CHAPTER II-1 REGULATION 40 PARAGRAPH 1.3._x001C_ CORRECT PRIOR TO NEXT U.S. VOYAGE.
Documentation
Issued 17 October 1990
Resolved
VESSES OIL TRANSFER PROCEDURES DID NOT CONTAIN PROCEDURES FOR EMPTYING MANIFOLD, PROCEDURES FOR TOPPING OFF TANKS AND PROCEDURES FOR REPORTING OILDISCHARGE INTO WATER AS REQUIRED BY 33CFRE155.750(a)(2)(iii),(7) & (9).
Navigation
Issued 17 October 1990
Resolved
VESSELS B.A. CHART 899 WAS NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(b).
Navigation
Issued 18 December 1984
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.