MAURY USCG vessel records Sign in
← All vessels

MORILLO

MORILLO is a 1971 freight ship. The Coast Guard has recorded 21 inspections since 1984, most recently in October 2007, along with 42 deficiencies — 11 with no resolution recorded — and 2 operational controls.

Records from 1984 to 2007. Most recent: inspection, 15 October 2007.

Built
1971
Last inspected
15 October 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7105031 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
E5U2128
222338
Flag
COOK ISLANDS
—
Maury page id
psix-222338

Inspections, by type

…with no type recorded15
…past their stated due date9
Years with a record 13 calendar years (1984–2007)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9983 - Regulatory (Subpart C or D), Gross Ton
5672 - Regulatory (Subpart C or D), Net Ton
10800 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 21

15 October 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3080540
28 September 2007 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3064712
20 October 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2804446
20 December 2002 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1721672
19 January 2002 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1485094
8 January 2002 Annual Inspection · Ballast Water Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1474779
31 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286822
23 January 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 286328
24 January 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 274053
19 March 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 388955
22 January 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 386809
20 November 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 384931
20 November 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 715816
21 February 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 348928
17 October 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 339830
16 April 1990 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 521733
7 August 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 331900
25 July 1989 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 331684
22 August 1988 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 325213
9 April 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 301338
18 December 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 299550

Deficiency record · 42

Construction/Loadline › Hull › Transverse Frame
Issued 28 September 2007 Resolved
Hull, Port side vicinity of Frame 83- Indent from previous port, crew conducted repairs but repairs were not checked by class society. Vessel to have class verify repairs prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2007
Resolution: Received report from class addressing the Hull indent, to be permanently repaired at next drydock. See scanned copy of class report in the documents section.
Fire Fighting › Emergency Fire Pumps
Issued 8 January 2002 No resolution recorded
Main and Emergency fire pumps are inoperable. Bearings and seals are wasted. Prior to departing the Port of Pascagoula and conduction cargo operations repair both pumps to the satisfaction of Flag/Class and U.S. Coast Guard. (Solas 60 - Reg 6.5)
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Engineering › Sea-water System (primary cooling)
Issued 8 January 2002 No resolution recorded
#1 and #2 MDE S/W Pumps are leaking excessively and seals are worn. Repair to the satisfaction of Flag/Class before 18JAN02. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Engineering › Sea-water System (primary cooling)
Issued 8 January 2002 No resolution recorded
#4 ship service generator S/W colling valve to lube oil cooler is leaking. Seal is bad. Repair to the satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Lifesaving › Inflatable Liferafts
Issued 8 January 2002 No resolution recorded
Provide Life Saving servicing reports prior to departing Port of Pascagoula to U.S. Coast Guard
Action required: 17 - Rectify deficiencies prior to departure
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld] rcvd copies of service reports.
Engineering › Diesel Engine (propulsion-electric)
Issued 8 January 2002 No resolution recorded
#2 MDE return line STBD/outboard flange is leaking. Repair to the satisfaction of Flag/Class NLT 18January02.
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Engineering › Generator (propulsion-electric)
Issued 8 January 2002 No resolution recorded
#3 ship service generator has exhaust leak (bottom level). Repair to the satisfaction of Flag/ Class NLT 18January, 2002. LEGACY COMPONENT DESC: Exhaust
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Engineering
Issued 8 January 2002 No resolution recorded
Provide insulation on all exhaust piping as 2nd and 3rd level in engine room. Repair to the satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Exhaust Piping
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Engineering
Issued 8 January 2002 No resolution recorded
S/W supply valve to lower level Port side Bilge/Ballast pump is leaking and seal is worn. Repair to the Satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Supply valve/Bilge Ballast Pump
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Engineering › Bilge Water Management System
Issued 8 January 2002 No resolution recorded
Discharge Flange on Bilge/Ballast Pump lower level Port side is leaking excessively. Repair to the Satisfaction of Flag/Class NLT 18January02. LEGACY COMPONENT DESC: Discharge Flange
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Electrical › Electric Supply System (service)
Issued 8 January 2002 No resolution recorded
Provide non-conductive material/matting at 440 power panel for reefer system. Provide NLT 18January02. (Solas 60 II/27 (a)) LEGACY COMPONENT DESC: 440 Power Panel
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Pollution Prevention/Response › Prevention Equipment
Issued 8 January 2002 No resolution recorded
Provide Mechanical means of closing all containment areas. Repair to satisfaction of Flag/Class NLT 18January02. (33CFR155.310) LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Due 18 January 2002 — due date passed with no resolution recorded
Resolution: Repaired to satisfaction of the Administration/Cayman Islands Shipping Registry, dtd 18Jan02 by Surveyor/[name withheld].
Construction/Loadline
Issued 31 January 2001 Resolved
CLASS TO PROVIDE REPORT ATTESTING TO REPAIRS TO THE PORT SIDE BOW FORWARD OF THE COLLISION BULKHEAD, DAMAGES WERE SUSTAINED DURING A COLLISION WITH ABARGE ON 31JAN01. CORRECT PRIOR TO VESSEL'S DEPARTURE FROM THE PORT OF PENSACOLA, FLORIDA.
Condition: Unknown
Due 1 February 2001
Resolved 4 April 2001
Pollution Prevention/Response
Issued 23 January 2001 Resolved
Marine Sanitation device has numerous holes in plating and pinhole leak in discharge piping. (33 CFR 159.7) Make permanent repairs to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 23 February 2001
Resolved 8 January 2002
Resolution: MSD repaired to the sat. of the attending USCG Marine Inspector.
Engineering
Issued 23 January 2001 Resolved
Excessive leakage from fuel oil purifier for generators (SOLAS 60 I/10): Repair prior to departure to the satisfaction of certificate issueing authority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Engineering
Issued 23 January 2001 Resolved
Excessive oil in bilges, decks, ladders (SOLAS 60 I/10) Clean and remove oil to satisfaction of certificate issueing authority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Engineering
Issued 23 January 2001 Resolved
Excessive leaks from lube oil system into each cylinder on MDE. SOLAS 60 I/10): Repair prior to departure to the satisfaction of the safety construction certificate issueing authority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Lifesaving
Issued 23 January 2001 Resolved
Missing Retro reflective tape on hull of both life boats (SOLAS 74 AMN III/Reg 30.2.7) Replace.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Electrical
Issued 23 January 2001 Resolved
Electrical panel boxes in crane towers missing covers (SOLAS 60 II/REG 27(a)(i)(1); Install covers.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Engineering
Issued 23 January 2001 Resolved
Wasted fuel oil vent cover stbd side aft (33 CFR 155.320); Repair to the satisfaction of the certificate(s) issuing authority.
Condition: Unknown
Due 23 February 2001
Resolved 8 January 2002
Resolution: Fuel oil vent repaired to the Satisfaction of the Admin/CJ, surveyor/[name withheld], ltr dtd 18JAN02.
Electrical
Issued 23 January 2001 Resolved
Oil leaks around cylinder heads on #4 ships service generator (SOLAS 60 I/11); Repair to the satisfaction of the certificate(s) issueing authority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Lifesaving
Issued 23 January 2001 Resolved
missing and loose beckets on port lifeboat (60SOLAS III/Reg 8); Repair/replace to the satisfaction of the certificate(s) issueing authority
Condition: Unknown
Due 28 February 2001
Resolved 31 January 2001
Electrical
Issued 23 January 2001 Resolved
Paint locker explosion proof light missing screws (SOLAS 60 II/27) Relace to the satisfaction of the certificate(s) issueing athority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Unknown
Issued 23 January 2001 Resolved
lagging on fire pump exhaust flammable natural fiber (cotton) (SOLAS 74 AMNII-2/21); remove flammable lagging to the satisfaction of the certificate(s) issueing authority
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Engineering
Issued 23 January 2001 Resolved
Excessive oil on deck of emergency fire pump & steering gear spac (SOLAS 60I/11); Clean to the satisfaction of the certificate(s) issueing authority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Construction/Loadline
Issued 23 January 2001 Resolved
Stbd aft weld Deteriorated on bulwark (ILLC 66 Annex I/15): repair, replaceto satisfaction of certificate issueing authority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Engineering
Issued 23 January 2001 Resolved
Excessive fuel oil leaks on all ships service generators (SOLAS 60 I/11): Repair to the satisfaction of class prior to departing the Port of Houston.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Engineering
Issued 23 January 2001 Resolved
Excessive fuel oil leak in #6 cylinder from MDE (SOLAS 60 I/11): Repair to the satisfaction of class prior to departing the Port of Houston.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Deck/Cargo
Issued 23 January 2001 Resolved
Overfill containmnet missing plugs thru out vessel. (33CFR 155.320 (b) Replace to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Electrical
Issued 23 January 2001 Resolved
Numerous explosion proof light covers cracked in engine room (SOLAS 74 AMNDCH II/REG 27) Repair/replace to satisfaction of the safety construction certificate issueing authority.
Condition: Unknown
Due 23 February 2001
Resolved 31 January 2001
Lifesaving
Issued 24 January 2000 Resolved
PRIOR TO DEPARTURE CLEAR DEBRIS IN THE PUMP ROOMS LOCATED ON DECK WHICH IS CREATING A FIRE HAZARD.
Condition: Unknown
Due 24 January 2000
Resolved 26 January 2000
Lifesaving
Issued 24 January 2000 Resolved
PRIOR TO DEPARTURE REMOVE TIES OF ALL LIFERAFTS.
Condition: Unknown
Due 24 January 2000
Resolved 26 January 2000
Documentation
Issued 24 January 2000 Resolved
PRIOR TO DEPARTURE PROVIDE COPIES OF THE CERTIFICATE OF REGISTRY AND COFR.
Condition: Unknown
Due 24 January 2000
Resolved 26 January 2000
Construction/Loadline
Issued 24 January 2000 Resolved
MARK VESSEL'S LOADLINE IN ACCORDANCE WITH THE LOADLINE CERTIFICATE AND PROVIDE CLASS REPORT ATTESTING TO PROPER MARKING PRIOR TO 24FEB00._x001C_
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Engineering
Issued 24 January 2000 Resolved
OILY WATER SEPARATOR SHOWING EXCESSIVE LEAKAGE. PROVIDE CLASS REPORT ATTESTING TO PROPER OPERATION PRIOR TO 24FEB00.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Fire Fighting
Issued 24 January 2000 Resolved
PROVIDE CLASS REPORT ADDRESSING POSITION OF FIXED CO2 BOTTLES. BOTTLES ARE RESTING ON THE DECK AND ARE SHOWING SIGNS OF RUSTING. PRIOR TO 24FEB00.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Fire Fighting
Issued 24 January 2000 Resolved
PRIOR TO DEPARTURE REMOVE PORTABLE EXTINGUISHERS STOWED IN CO2 ROOM.
Condition: Unknown
Due 24 January 2000
Resolved 26 January 2000
Navigation
Issued 20 November 1995 Resolved
BLOCK DIAGRAM MISSING FROM REMOTE STEERING GEAR CHANGE OVER PROCEDURES._x001C_ VESSEL HAS A PICTURE OF THE UNIT ON THE PROCEDURES IN LIEU OF BLOCK DIAGRAMOF THE UINT ON THE BRIDGE IAW 33 C.F.R. 164.35(K)._x001C_
Condition: Unknown
Due 19 March 1996
Resolved 19 March 1996
Electrical
Issued 20 November 1995 Resolved
PROVIDE LIGHT COVERS FOR LIGHTS IN ENGINE ROOM AND CARPENTRY SHOP LOCATED_x001C_ ON MAIN DECK IAW SOLAS CHAPTER II-1 REGULATION 40 PARAGRAPH 1.3._x001C_ CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 19 March 1996
Resolved 19 March 1996
Documentation
Issued 17 October 1990 Resolved
VESSES OIL TRANSFER PROCEDURES DID NOT CONTAIN PROCEDURES FOR EMPTYING MANIFOLD, PROCEDURES FOR TOPPING OFF TANKS AND PROCEDURES FOR REPORTING OILDISCHARGE INTO WATER AS REQUIRED BY 33CFRE155.750(a)(2)(iii),(7) & (9).
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Navigation
Issued 17 October 1990 Resolved
VESSELS B.A. CHART 899 WAS NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(b).
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Navigation
Issued 18 December 1984 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 November 1995
Resolved 21 November 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.