MAURY USCG vessel records Sign in
← All vessels

LORY I

LORY I is a 1971 freight ship. The Coast Guard has recorded 26 inspections since 1985, most recently in December 2001, along with 50 deficiencies.

Records from 1985 to 2001. Most recent: inspection, 9 December 2001.

Built
1971
Last inspected
9 December 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7105586 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP9226
222343
Flag
GREECE
—
Maury page id
psix-222343

Inspections, by type

…with no type recorded25
Years with a record 15 calendar years (1985–2001)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1598 - Regulatory (Subpart C or D), Gross Ton
1225 - Regulatory (Subpart C or D), Net Ton
3054 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 26

9 December 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 648010
27 November 2001 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 296164
11 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294620
15 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278899
20 March 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 276061
15 January 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 412249
23 September 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 408238
19 September 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 408100
16 September 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 69191
16 December 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 398563
3 November 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 384431
23 June 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 380915
12 September 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 370619
20 July 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 538936
19 April 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 443771
29 October 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347898
1 May 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 343514
28 November 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 528337
30 March 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 336280
6 November 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 484175
19 April 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 329909
18 April 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 322724
2 November 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 437782
22 April 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 315614
29 April 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 308408
1 April 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 301195

Deficiency record · 50

Navigation
Issued 27 November 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 November 2001
Resolved 27 November 2001
Resolution: MARINE VIOLATION CASE INITIATED.
Engineering
Issued 11 October 2001 Resolved
STBD GENERATOR HAS EXCESSIVE F/O AND L/O LEAKS. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Lifesaving
Issued 11 October 2001 Resolved
ENGINE ROOM AND STEERING COMPARTMENT MACHINERY COVERED WITH OIL. WIPE DOWN ALL MACHINERY AND REMOVE STANDING OIL PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Navigation
Issued 11 October 2001 Resolved
VESSEL'S ECHO DEPTH SOUNDER DOES NOT WORK. REPAIR TO THE SATISFACTION OF CLASS OR PROVIDE TECH REPORT PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Navigation
Issued 11 October 2001 Resolved
VESSEL'S AUTO PILOT IS INOPERABLE. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Navigation
Issued 11 October 2001 Resolved
VESSEL'S STBD RADAR DOES NOT OPERATE. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Navigation
Issued 11 October 2001 Resolved
VESSEL DID NOT PERFORM OR LOG EQUIPMENT TESTS AS REQUIRED BY 33 CFR 164.25.VESSEL MUST PERFORM TESTS PRIOR TO ENTRY INTO U.S. WATERS.
Condition: Unknown
Due 11 October 2001
Resolved 11 October 2001
Engineering
Issued 11 October 2001 Resolved
PORT GENERATOR HAS LEAKING LIQUID STEEL PATCH ON TOP OF AIR COOLER. MAKE PERMANENT REPAIRS TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 December 2001
Resolved 9 December 2001
Navigation
Issued 11 October 2001 Resolved
THE FLEXIBLE HOSES ON THE PORT AND STARBOARD STEERING GEAR ARE CRACKED AND LEAKING. REPLACE HOSES TO THE SATISFACTORY OF CLASS PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Navigation
Issued 11 October 2001 Resolved
THE STEERING GEAR EMERGENCY STEERING HAND PUMP LEAKS EXCESSIVLY WHEN OPERATED. REPAIR TO THE SATISFACTION OF CLASS, PRIOR TO THE DEPARTING PORT.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Engineering
Issued 11 October 2001 Resolved
THE 3 WAY VALVE ON THE OWS IS INOPERABLE. REPAIR OR REPLACE VALVE TO THE SATISFACTION OF CLASS PRIOR TO OPERATING OWS IN US WATERS.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Lifesaving
Issued 11 October 2001 Resolved
CREW UNABLE TO PERFORM SATISFACTORY FIREAND ABANDON SHIP DRILLS. PERFORM SATISFACTORY FIRE AND ABANDON SHIP DRILLS PRIOR TO DEPARTING PORT. (SOLAS 74A I/11)
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Accommodation/Occupational Safety
Issued 11 October 2001 Resolved
VESSEL SUPERSTRUCTURE IS INFESTED WITH ROACHS. PROVE THAT PROPER FUMIGATIONHAS BEEN CARRIED OUT PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Accommodation/Occupational Safety
Issued 11 October 2001 Resolved
VESSEL DOES NOT HAVE CLEAN DRINKING WATER ABOARD. CREW HAS BEEN USING LIFE BOAT EMERGENCY RATIONS. PROVIDE ADEQUATE DRINKING WATER FOR CREW.
Condition: Unknown
Due 12 October 2001
Resolved 16 November 2001
Lifesaving
Issued 11 October 2001 Resolved
CREW HAS BEEN USING EMERGENCY RATIONS WATER FROM LIFE BOAT. PROVIDE PROPER WATER STORES FOR LIFEBOATS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Lifesaving
Issued 11 October 2001 Resolved
PORT AND STARBOARD LIFEBOAT DAVIT CABLES MUST BE END FOR ENDED PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Construction/Loadline
Issued 11 October 2001 Resolved
THE ACCOMODATION DRAIN PIPE OVERBOARD CHECK VALVE IS BROKEN AND TAKING IN WATER IN ROUGH SEAS. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTINGPORT.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Accommodation/Occupational Safety
Issued 11 October 2001 Resolved
SHIPS TYPE III MSD SYSTEM IS INOPERABLE DUE TO FROZEN INLET VALVE ON THE HOLDING TANK. SHIP IS TO PROVIDE PORTABLE TOILETS ABOARD IMMEDIATELY AND MAINTAIN ONBOARD UNTIL TYPE III MSD IS REPAIRED TO THE SATISFACTION OF US COAST GUARD.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Engineering
Issued 11 October 2001 Resolved
#1 AND #2 CRANKCASE EXHAUST VENTS FOR PORT AND STARBOARD GENERATOR ON THE BOAT DECK LEAKING OIL. PROVIDE CONTAINMENT TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Documentation
Issued 11 October 2001 Resolved
VESSELS C/O AND AB HAVE EXPIRED TRANSITIONAL LICENSES AND C/E AND AB DO NOTHAVE APPLICATION AND/OR PANAMANIAN LICENSE. PROVIDE UP TO DATE LICENSES OR APPLICATIONS FORLICENSES PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Construction/Loadline
Issued 11 October 2001 Resolved
ALL VESSELS WATERTIGHT DOORS AND HATCHES ARE SEVERLY WASTED AND NOT SEALING. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Navigation
Issued 11 October 2001 Resolved
SOFT PATCH FOUND LEAKING IN STEERING COMPARTMENT PORT SIDE PIPING FROM RUDDER COMPARTMENT. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Engineering
Issued 11 October 2001 Resolved
PORT M/E HAS FUEL OIL LEAKS ON THE #3 & #5 HIGH PRESS FUEL OIL INJECTION PUMPS. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Engineering
Issued 11 October 2001 Resolved
STARBOARD MAIN ENGINE IS LEAKING OIL CONTINUOUSLY FROM CRANK CASE COVERS. REPAIR TO THE SATISFACTION OF CLASS PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 October 2001
Resolved 16 November 2001
Engineering
Issued 20 March 2000 Resolved
REPAIR SUCTION LINE TO THE OILY WATER SEPARATOR.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 20 March 2000 Resolved
UPDATE FIRE CONTROL PLAN.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Documentation
Issued 15 January 1998 Resolved
REPLACE GENERAL ARRANGEMENT PLAN_x001C_ SOLAS 60 II/20
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Navigation
Issued 15 January 1998 Resolved
LEAKING STEERING RAM_x001C_ SOLAS 60 II/29A
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Engineering
Issued 15 January 1998 Resolved
REPLACE AND TEST PORT RAW WTER COOLING PUMP._x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Construction/Loadline
Issued 15 January 1998 Resolved
LEAKING PACKING ON GENERAL SERVICE PUMP._x001C_ SOLAS 74 AMND II-2/21
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Construction/Loadline
Issued 15 January 1998 Resolved
LEKING PACKING ON BALLAST PUMP_x001C_ SOLAS 60 II/18
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 15 January 1998 Resolved
LEAKING PACKING ON EMERGENCY FIREPUMP_x001C_ SOLAS 74 AMND II-2/21
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Construction/Loadline
Issued 15 January 1998 Resolved
MISSING VALVE HANDLE FOR EMERGENCY BILGE SUCTION._x001C_ SOLAS 60 REG II/18 (G)(I)
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Electrical
Issued 15 January 1998 Resolved
REPAIR LIGHTS IN ENGINE ROOM_x001C_ SOLAS 60 II/27A
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Electrical
Issued 15 January 1998 Resolved
MISSING LIGHT COVERS IN ENGINE ROOM AND STEERING GEAR ROOM._x001C_ SOLAS 60 REG II/27A
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Electrical
Issued 15 January 1998 Resolved
LOOSE WIRING ON LGHTING IN ENGINE ROOM AND STEERING ROOM._x001C_ SOLAS 60 REG II/27A
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Navigation
Issued 15 January 1998 Resolved
REPLACE INDACATOR LIGHT #2 STEERING PUMP._x001C_ SOLAS 60 REG II/29
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Engineering
Issued 15 January 1998 Resolved
SEA WATER COOLING LEAK ON PORT MAIN ENGINE._x001C_ SOLAS 60 REG II/11
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 15 January 1998 Resolved
REMOVE PAINT STORES FROM STEERING ROOM._x001C_ SOLAS 74 AMND II-2/20.1
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 15 January 1998 Resolved
DISCHARGED PORTABLE EXTINGUISHER IN ENGINE ROOM_x001C_ SOLAS 74 AMND II-2/21
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Electrical
Issued 15 January 1998 Resolved
MISSING RUBBER MATTING AT MAIN SWITCHBOARD._x001C_ SOLAS 60 II/27A ii
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 15 January 1998 Resolved
UPDATE FIRE CONTROL PLAN._x001C_ SOLAS 74 AMND II-2/20.1
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Electrical
Issued 15 January 1998 Resolved
MAIN SWITSHBOARD COVERS MISSING._x001C_ SOLAS 60 REG II/27 A ii
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Construction/Loadline
Issued 15 January 1998 Resolved
VALVE HANDLE FOR BALLAST TANK MISSING_x001C_ SOLAS 60 REG II/18
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Engineering
Issued 15 January 1998 Resolved
SEA WATER COOLING LINE TO MAIN ENGINE WASTED._x001C_ SOLAS 60 REG I/11
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Fire Fighting
Issued 15 January 1998 Resolved
FIRE MAIN FORWARD OF SUPER STRUCTURE WASTED/MISSING._x001C_ SOLAS 74 AMND II-2/21
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Electrical
Issued 15 January 1998 Resolved
INSTALL DUNNAGE TO SECURE EMERGENCY BATTERIES._x001C_ SOLAS 60 REG I/11
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Engineering
Issued 15 January 1998 Resolved
REPLACE FLAME SCREENS PORT/STARBOARD FUEL VENTS._x001C_ SOLAS 60 REG I/11.
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Accommodation/Occupational Safety
Issued 15 January 1998 Resolved
REPAIR LEAKING GALLEY DRAIN_x001C_ SOLAS 60 I/11
Condition: Unknown
Due 15 January 1998
Resolved 27 January 1998
Engineering
Issued 23 June 1995 Resolved
OWS NOT WORKING PROPERLY DUE TO GENERATOR DOWN.WHEN FIX HAVE CLASS COME ONBOARD TO VERFY PROPER OPERATION.
Condition: Unknown
Due 1 August 1995
Resolved 24 July 1995

Ownership record