DISCOVERY is a 1972 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1984, most recently in April 2005, along with 65 deficiencies and 1 operational control.

Records from 1984 to 2005. Most recent: operational control imposed, 30 April 2005.

Built
1972
Last inspected
30 April 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7108514 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222374
Flag
BERMUDA
—
Maury page id
psix-222374

Inspections, by type

…with no type recorded44
Years with a record 14 calendar years (1984–2005)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it20186 - Convention (Subpart B), Gross Ton
20186 - Regulatory (Subpart C or D), Gross Ton
3390 - Dead Weight, Ton
11165 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest. Towing vessels are barely present in the record before 1992, so tow-unit membership for activities older than that is recorded only partially.

DIOSKOUROI Freight Barge · MISLE 54414 · 10 October 1991 · activity 519289

Inspection history · 75

30 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2346119
29 March 2005 ISPS II Exam · Deficiency Check · COC-CVE Annual
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2322698
18 March 2004 Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2023022
18 March 2004 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2026984
9 September 1998 Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1395038
15 July 1998 Type not recorded
No type recorded · MSD SITKA · USCG Arctic District (CGD-A) · Activity 40484
11 June 1998 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 521383
5 June 1998 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 417218
5 June 1998 Control Verification · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1415023
27 May 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 422071
11 May 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 414836
15 April 1998 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1123110
25 January 1995 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1353688
11 January 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 374031
19 December 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 374050
19 December 1994 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1428424
8 March 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 365008
8 March 1994 MARPOL Annex V Examination · Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1377143
23 February 1994 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 364983
7 October 1992 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254335
11 September 1992 Certificate of Compliance · Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1254907
9 August 1992 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1393877
30 July 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 687366
30 July 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 687370
31 May 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 538617
16 May 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 350864
16 May 1992 Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 955027
10 October 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 519289
10 October 1991 Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936554
15 July 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 347205
15 July 1991 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1311252
9 April 1991 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 905100
8 January 1991 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341300
8 January 1991 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 909960
29 September 1990 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1212247
13 August 1990 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1229023
8 May 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 526572
8 May 1990 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1223389
28 April 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 926269
28 January 1990 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1229051
23 October 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 333283
23 October 1989 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1199276
27 June 1989 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1036033
20 May 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 522849
7 April 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1044448
13 January 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 886918
14 October 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 326844
14 October 1988 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201897
14 October 1988 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1203333
14 October 1988 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1204618
28 June 1988 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1342272
12 March 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1030977
2 January 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 473605
28 November 1987 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335759
14 November 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 510912
24 August 1987 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1004277
19 May 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 316199
19 May 1987 Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1025369
8 October 1986 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 311871
30 June 1986 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1309261
15 March 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 307540
15 March 1986 Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 995317
18 January 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997137
28 December 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 306133
28 December 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997136
14 December 1985 Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 990707
23 November 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 495480
16 August 1985 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1299740
4 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 301845
4 May 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1290841
24 November 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 299044
24 November 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1282360
19 September 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 460470
18 June 1984 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 296765
11 June 1984 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 296631

Deficiency record · 65

Lifesaving › Lifeboat
Issued 18 March 2004 Resolved
Prior to operating the #8 boat as a passenger tender make repairs to the port engine starter. IAW SOLAS 74/78 Chap III LEGACY COMPONENT DESC: Propulsion Starting System
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 March 2004
Resolution: Made repairs to #8 boats engine starter prior to leaving the hawaiian islands, all sat.
Stability › Watertight Integrity
Issued 18 March 2004 Resolved
Make permanent repairs to class III watertight door #9. IAW SOLAS 60/ II.C Reg. 13. i. i.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2004
Resolved 20 March 2004
Resolution: Made repairs to watertight door #9. Fault caused by non-functioning non-return valve, replaced valve and door working properly now.
Fire Fighting
Issued 5 June 1998 Resolved
COMBUSTIBLE MATERIALS ARE STOWED IN LOCKERS BENEATH AFT PASSENGER STAIR TOWER ON FIESTA DECK.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Electrical
Issued 5 June 1998 Resolved
EXPOSED 220V WIRING FROM BROKEN OUTLET ACROSS FROM CABIN C-43 PRESENTS AND IMMEDIATE SAFETY HAZARD.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 5 June 1998 Resolved
FIRE SCREEN DOORS E-12 AND C-23 DO NOT FULLY CLOSE AND LATCH._x001C_
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Fire Fighting
Issued 5 June 1998 Resolved
INDICATORS FOR FIRE SCREEN DOORS A5 AND F17 GIVE INCORRECT STATUS WHEN_x001C_ DOORS ARE OPEN.
Condition: Unknown
Due 27 July 1998
Resolved 9 September 1998
Construction/Loadline
Issued 5 June 1998 Resolved
MECHANICAL AUDIBLE ALARMS FOR WTD'S 13, 15, AND 17 ARE INOPERABLE.
Condition: Unknown
Due 27 July 1998
Resolved 9 September 1998
Fire Fighting
Issued 5 June 1998 Resolved
SMOKE DETECTOR 26-52 GIVES REPEATED ALARM DUE TO CLOSE PROXIMITY TO #4 GENERATOR AND POSSIBLE EXHAUST LEAKS.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 5 June 1998 Resolved
HEAT DETECTOR IS NOT INSTALLED IN FREEZER #19 ON E-DECK.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 June 1998 Resolved
GALLEY AND CROSS-DECK ALLEYWAY ARRANGEMENT AND VENTILATION SYSTEMS DO NOT MEET REQUIREMENTS OF SOLAS 1992 RFSA'S._x001C_ ISSUE TO BE RESOLVED BETWEEN MSC AND FLAG STATE.
Condition: Unknown
Due 30 September 1998
Resolved 29 March 2005
Resolution: Annual exam from 2004 and letter from MSC dated 24Feb04.
Accommodation/Occupational Safety
Issued 5 June 1998 Resolved
LOW LOCATION LIGHTING IS NOT FULLY INSTALLED IN SEVERAL CREW ACCOMMODATION EGRESS AREAS PER SOLAS 1992 RFSA'S.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Lifesaving
Issued 27 May 1998 Resolved
EXCESSIVE COMBUSTIBLES LOCATED THROUGHOUT VESSEL DUE TO DRYDOCK STATUS
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
GALLEY AND CROSS DECK ALLEYWAY ARRANGEMENT AND VENTILATION SYSTEM DO NOT MEET THE REQUIREMENTS OF SOLAS 92 RFSA
Condition: Unknown
Due 27 July 1998
Resolved 18 February 2004
Accommodation/Occupational Safety
Issued 27 May 1998 Resolved
Low level lighting not in place in crew's berthing
Condition: Unknown
Due 1 July 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
NITROGEN BOTTLES NOT PROPERLY STOWED IN HYDRAULIC ROOM
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
COMPRESED GAS CYLINDERS THROUGHOUT VSL NOT STOWED IN APPROPRIATE LOCKERS
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
UNABLE TO WITNESS OPERATION OF VESSEL LAUNCHES DUE TO DRYDOCK STATUS
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
ELECTRICAL MATTING FOR DECK AREA IN FRONT OF MOTOR CONTROLLER FOR BOW THRUSTER AND FOR DECK AREA IN EMERGENCY GENERATOR SWITCHBOARD AREA MISSING
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
THE FOLLOWING FSD'S INOP DUE TO DRYDOCK STATUS: C17, L6, L10, F17, C25, C36, F19 AND C4
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
PERMANENTLY STOW/SECURE LOOSE METAL SHEETS IN OUTBOARD PORT CORRIDOR NEXT TO GALLEY
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
UNABLE TO WITNESS TEST OF WTD'S TO ENSURE COMPLIANCE WITH RFSA DUE TO DDX STATUS
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
HEAT DETECTORS, VICE SMOKE DETECTORS, ARE INSTALLED IN ENGINE ROOM CASING
Condition: Unknown
Due 27 July 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
FSD INDICATOR PANEL LIGHTS F4, E5, C5 AND R2 INOP
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
FSD INDICATORS A5, D21 INOP
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
SMOKE DETECTORS 26-03, 26-04, 26-52, AND 26-35 INOP
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
HEAT DETECTOR IN FREEZER #19, E DECK, MISSING
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Lifesaving
Issued 27 May 1998 Resolved
LOCATION OF CONTROLS FOR FSD #B6, LOCATED IN CABIN B346, NOT ADEQUATELY LABELED OUTSIDE SPACE. RECOMMEND THAT LOCATION OF CONTROL ADDITIONALLY BE ADDED TO FCP TO VERIFY USCG ACCEPTANCE
Condition: Unknown
Due 5 June 1998
Resolved 18 February 2004
Engineering
Issued 11 May 1998 Resolved
Install lagging on steam pipe at the corner of the starboard aft engine casing in the fan room on the observation deck.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Lifesaving
Issued 11 May 1998 Resolved
Effect repairs to the #4 lifeboat rudder gudgeon and pintle assembly to thesatisfaction of class.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Accommodation/Occupational Safety
Issued 11 May 1998 Resolved
Remove storage from staircase enclosures in the way of sideports.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Accommodation/Occupational Safety
Issued 11 May 1998 Resolved
Remove stores from blocking fire flap 27, Coral Deck.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Accommodation/Occupational Safety
Issued 11 May 1998 Resolved
Remove room attendant service carts from passageways when not in use.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Accommodation/Occupational Safety
Issued 11 May 1998 Resolved
Install escape signs in crew staircases, where missing.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Accommodation/Occupational Safety
Issued 11 May 1998 Resolved
Remove locker containing cleaning chemicals from passageway forward of the crew's bar.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Accommodation/Occupational Safety
Issued 11 May 1998 Resolved
Provide key in ready position onboard for security padlock to storeroom 668.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 11 May 1998 Resolved
Install smoke detectors in all cold storage rooms with ambient temp of lessthan 5 degrees Celsius. Heat detectors may be installed in lieu of smoke detectors where condensation is a problem.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 11 May 1998 Resolved
Prove proper operation of smoke detector 24-44 in sausage storeroom.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 11 May 1998 Resolved
Remove combustible stores from #1 fan room, properly stow.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 11 May 1998 Resolved
Replace missing structural fire protection insulation on bulkheads and_x001C_ overhead of aft steering and Omni purification plant spaces.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 11 May 1998 Resolved
Properly insulate new vent ducting and seal aft bulkhead penetrations in steering space.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Engineering
Issued 11 May 1998 Resolved
Repair to the satisfaction of class exhaust leaks on #3 and #4 ship's_x001C_ service diesel generators.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Engineering
Issued 11 May 1998 Resolved
Permanently repair to the satisfaction of class the following leaking pipes; 2 S/W pipes above #2 S/W cooling pump E/R stbd side; firemain pipingat the fwd foam station E/R stbd; grey water pipe outboard of the fwd evaporator E/R stbd; fuel return header piping on #2 main diesel engine.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Engineering
Issued 11 May 1998 Resolved
In lieu of a rubber drain hose, install class society approved vent drain_x001C_ piping for fuel oil day tank, stabilizer flat.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Construction/Loadline
Issued 11 May 1998 Resolved
Renew wasted gussets for overboard spool piece starboard side forward in_x001C_ the bow thruster switchboard room.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Documentation
Issued 11 May 1998 Resolved
Satisfy all comments of Marine Safety Center letter #POO3472 dated 05MAY98.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 11 May 1998 Resolved
Repair fire screen door C14A located at the forward entrance of the passenger galley.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 11 May 1998 Resolved
Replace missing smoke detector in the starboard side aft passageway of thepassenger galley.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Fire Fighting
Issued 19 December 1994 Resolved
Repair fire screen door C-32 so it will close completely when activated.
Condition: Unknown
Due 15 February 1995
Resolved 15 February 1995
Fire Fighting
Issued 19 December 1994 Resolved
Repair hydraulic closer on fire screen door C-9.
Condition: Unknown
Due 15 February 1995
Resolved 15 February 1995
Lifesaving
Issued 9 April 1991 Resolved
Procure and post illuminated lifeboat station signs.
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Electrical
Issued 8 January 1991 Resolved
INSTALL ADDITIONAL DECK LIGHTING FOR BOTH BUNKER STATIONS.
Condition: Unknown
Due 11 October 1991
Resolved 11 October 1991
Lifesaving
Issued 28 November 1987 Resolved
REPLACE WATERLIGHT/SMOKE SIGNAL ON STBD BRIDGEWING LIFEBUOY WATERLIGHT (EXPIRATION DATE IS 12/87).
Condition: Unknown
Due 28 November 1987
Resolved 28 November 1987
Fire Fighting
Issued 28 November 1987 Resolved
SERVICE/CLEAN THE FWD INT'L SHORE CONNECTION STORAGE LOCKER TO ENSURE THAT CONNECTION MAY BE EASILY REMOVED IN THE EVENT OF AN EMERGENCY.
Condition: Unknown
Due 28 November 1987
Resolved 28 November 1987
Fire Fighting
Issued 28 November 1987 Resolved
RENEW/REPAIR LEAKING FIRE HOSE AT PORTSIDE FIRE STATION OF AFT MOORING DECK.
Condition: Unknown
Due 28 November 1987
Resolved 28 November 1987
Lifesaving
Issued 28 November 1987 Resolved
SHORTEN #2 LIFEBOAT LIFELINES TO AN ACCEPTABLE LENGTH THAT PERMITS SAFE USEOF LINES AND SAFE DEPLOYMENT OF LIFEBOAT.
Condition: Unknown
Due 28 November 1987
Resolved 28 November 1987
Lifesaving
Issued 28 November 1987 Resolved
RESTENCIL SUPPLY/PROVISION SPACE ON #11 LIFEBOAT AND ADD ALCOHOL TO COMPASSIN SAME.
Condition: Unknown
Due 28 November 1987
Resolved 28 November 1987
Fire Fighting
Issued 28 November 1987 Resolved
DEMONSTRATE PROPER OPERATION OF FIRESCREEN DOOR # FDC-18F FROM REMOTE LOCATION.
Condition: Unknown
Due 28 November 1987
Resolved 28 November 1987
Navigation
Issued 8 October 1986 Resolved
33 CFR 164.25 VESSEL DUD NOT LOG VITAL MACHINERY TESTS 12HRS BEFORE ENTERING HONOLULU HARBOR.
Condition: Unknown
Due 8 October 1986
Resolved 8 October 1986
Unknown
Issued 15 March 1986 Resolved
CONDUCT 1ST QUARTERLY CONTROL VERIFICATION RE-EXAM
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Unknown
Issued 15 March 1986 Resolved
CONDUCT 2ND QUARTERLY CONTROL VERIFICATION RE-EXAMINATION
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Fire Fighting
Issued 15 March 1986 Resolved
INSTALL CLOSELY FITTING DRAFT STOPS AT NO MORE THAN 46' INTERVALS IN THE AIR SPACES ENCLOSED BEHIND CEILINGS IN ALL CORRIDORS AND ALLEYWAYS IN THE ACCOMODATION AND SERVICE SPACES.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Fire Fighting
Issued 15 March 1986 Resolved
UNTIL MISSING DRAFT STOPS ARE INSTALLED, POST ADDITIONAL FIRE PATROLS IN AREAS NOT PROTECTED BY DRAFT STOPS.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Fire Fighting
Issued 14 December 1985 Resolved
VESSEL FOUND NOT IN COMPLIANCE WITH SOLAS 60 REGULATIONS 49 PARA.C WHICH REQUIRES DRAFT STOPS IN AIRSPACES ENCLOSED BEHIND CEILING PANELS NOT MORE THAN 45 FEET APART IN ALL ACCOMMODATIONS AND SERVICE SPACES.VESSEL WILL NOTBE ALLOWED TO EMBARK PASSENGERS IN ANY U.S. PORT IF THIS IS NOT CORRECTED.
Condition: Unknown
Due 14 December 1985
Resolved 14 December 1985
Documentation
Issued 4 May 1985 Resolved
VESSEL WAS MISSING THE FOLLOWING INFORMATION IN REGARDS TO OIL TRANSFER INFORMATION: EMPTYING CONTAINMENT TENDING MOORINGS
Condition: Unknown
Due 15 March 1986
Resolved 4 May 1985
Navigation
Issued 4 May 1985 Resolved
VESSEL'S MAGNETIC COMPASS DEVIATION TABLE WAS DATED JULY 1981.
Condition: Unknown
Due 4 May 1985
Resolved 4 May 1985

Ownership record