MAURY USCG vessel records Sign in
← All vessels

SANTE MANNA

SANTE MANNA is a 1972 freight ship. The Coast Guard has recorded 134 inspections since 1984, most recently in June 2012, along with 124 deficiencies and 30 operational controls.

Records from 1984 to 2012. Most recent: operational control imposed, 5 June 2012.

Built
1972
Last inspected
5 June 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7116834 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222479
Flag
PANAMA
—
Maury page id
psix-222479

Inspections, by type

…with no type recorded99
Years with a record 28 calendar years (1984–2012)
The 134 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2556 - Convention (Subpart B), Gross Ton
999 - Regulatory (Subpart C or D), Gross Ton
1036 - Convention (Subpart B), Net Ton
642 - Regulatory (Subpart C or D), Net Ton
2400 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CROSBY POWER Towing Vessel · MISLE 104530 · 3 July 1998 · activity 106961

Inspection history · 134

5 June 2012 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4334575
9 January 2012 Deficiency Check · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4221316
25 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3951170
11 February 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3942628
23 January 2011 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3930793
23 December 2010 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3915153
18 December 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3913076
4 October 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3863281
2 September 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3838654
25 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3684840
22 February 2010 Type not recorded
No type recorded · USCGC DALLAS (WHEC 716) · Activity 3684372
11 February 2010 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3677715
26 December 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3654527
4 December 2009 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3644340
8 July 2009 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3528394
14 May 2009 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3526569
12 February 2009 Administrative Inspection · PII Safety Exam · ISPS III Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3400677
29 August 2008 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3312325
7 August 2008 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3296171
9 July 2008 ISPS III Exam · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3258544
18 April 2008 MARPOL Annex V Examination · ISPS III Exam · PI Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3185447
16 April 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3185730
23 January 2008 Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3129170
14 November 2007 PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3094454
4 October 2007 Type not recorded
No type recorded · Maritime Safety & Security Team Miami (91114) · Activity 3072746
9 July 2007 ISPS II Exam · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2987539
8 July 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2987714
8 July 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2988436
7 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2929899
7 May 2007 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2930325
16 April 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2908634
2 April 2007 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2900055
14 January 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2855460
17 July 2006 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2713902
17 April 2006 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2626279
21 February 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2588872
19 February 2006 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2588117
19 February 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2588120
19 February 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2588309
18 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2431089
25 April 2005 PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2341982
25 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343027
6 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2327775
7 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2297607
31 January 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2297578
8 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2237367
1 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2232329
18 October 2004 PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2222942
14 August 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2165727
6 August 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2157939
2 August 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2153877
11 July 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2130552
6 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2124009
10 June 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2098072
11 May 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2064585
19 April 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2047230
8 December 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1953581
19 October 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1931533
29 August 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1890774
11 August 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1873496
21 July 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1859216
7 July 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1837989
16 June 2003 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1818561
13 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1772897
1 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1766269
24 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1762320
23 March 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1761770
24 February 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1748637
13 January 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1729372
5 August 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1657093
5 August 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1713707
8 July 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1642834
1 July 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1639409
14 June 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1630852
19 May 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1618073
20 December 2001 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1473674
15 December 2001 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1475486
15 November 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 295540
11 May 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 289988
5 April 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 288669
2 August 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 123199
11 May 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 539175
20 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 273908
6 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 273471
24 November 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 435180
9 September 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 432593
7 June 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428864
7 August 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 418792
3 July 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 106961
30 April 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 67963
9 April 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 414715
5 March 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 460459
26 February 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 413212
23 January 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 412182
18 July 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 405930
26 June 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 405129
19 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 395479
7 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 391873
31 May 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 391828
29 December 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 386451
19 December 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 386095
8 September 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 382455
27 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 652949
21 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 11933
7 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 380495
2 June 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 379050
1 June 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367797
20 May 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 366952
11 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 461148
25 February 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 535604
2 January 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 477674
30 December 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 648693
19 December 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 528058
3 December 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 484656
23 September 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 361771
30 July 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 514339
20 May 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 358533
13 November 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 652947
29 October 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 354263
23 October 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 354079
17 September 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 353266
10 August 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 652944
2 June 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 351747
19 May 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 438222
30 November 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347537
15 May 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 337123
23 March 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 329295
14 November 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 326825
23 August 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 508621
10 February 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 321474
1 July 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 317257
12 March 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 314861
29 November 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 305677
29 August 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 297683

Deficiency record · 124

Fire Fighting › Fire Main › Condition
Issued 9 January 2012 Resolved
0900 - The condition of the ship and its equipment shall be maintained to ensure it is fit to proceed to sea. The Bos'n Store and boat deck aft starboard side fire pipes are poorly maintained. The Reefer cable is in poor repair and there is a wire running through the emergency generator. 74 SOLAS (09) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2012
Resolved 13 January 2012
Resolution: Received flag report attesting to proper repairs.
Stability › Weathertight Integrity › General
Issued 9 January 2012 Resolved
0900- The means for securing and maintaining weathertightness shall ensure tightness in any seas. Broken window on boat deck and AC units and cables ruining integrity via penetrations. Emergency generator stop does not provide weathertight integrity, nor does the cargo hatch cover.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2012
Resolved 12 January 2012
Resolution: Received flag report attesting to proper repairs with the exception of the emergency pull stop watertight which is deferred until next dry dock.
Stability › Weathertight Integrity › General
Issued 9 January 2012 Resolved
0999 - All access openings in bulkheads shall be fitted with doors that provide equivalent strength to the unpierced bulkhead and are weathertight when closed. Boat deck dorrs and main deck port door are not weathertight. ICLL 66 II/12(1)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2012
Resolved 13 January 2012
Resolution: Received flag report attesting to proper repairs.
Stability › Watertight Integrity › General
Issued 9 January 2012 Resolved
The administration shall satisfy itself that the general strength of the hull is sufficient. Mian deck cargo hold vent door unable to close due to fridge. A hole in the wall also ruined watertight integrity. ICLL 66 I/1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2012
Resolved 13 January 2012
Resolution: Received flag report attesting to proper repairs.
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 9 January 2012 Resolved
0240 - Vessels are required to have medical certificates indicating crew members are medically fit for duty. 02 engineering officers and 02 deck crew did not have medical certificates. 33 USC 1223 (b) ILO 147(2)(3)&(4)
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2012
Resolved 13 January 2012
Navigation › Piloting/Steering › Marine Charts
Issued 23 December 2010 Resolved
Vessel has updated electric charts however, paper charts have not been updated since 2009.
Action required: 15 - Rectify deficiencies by next port
Resolved 12 January 2011
Resolution: New charts purchased and updated.
Stability › Weathertight Integrity › General
Issued 23 December 2010 Resolved
ICLL 66, Part 1 Article 15: Cargo hatch covers missing 12 out of 56 total hatch cover securing devices (dogs).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2011
Resolution: Cargo Hatch Dogs, replaced and properly fitted to cargo hatch covers.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 2 March 2009 Resolved
Properly man the vessel in accordance with the Panama Maritime Authority's minimum lay up manning letter date February 18, 2009 (ordered by Sector St. Petersburg COTP Order 09-015).
Action required: 705 - Other - as specified
Resolved 11 March 2009
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 12 February 2009 Resolved
The ships crew and captain have not been paid. All persons employed shall have signed articles of agreement with ship owner, including the amount of his wages and the conditions for its termination. ILO 147 Articles of Agreement, 3 and COMDTINST 16711.12a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: New owner/operator. All crew being paid.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 12 February 2009 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 12 November 2009
Resolution: New owner/operator. All had Flag State endorsements.
Documentation › Safety Management System › Company Responsibility/Authority Documentation
Issued 12 February 2009 Resolved
Multiple deficiencies were discovered during the vessel examination regarding crew training, drills, environmental protection, fire fighting, and overall maintenance of required equipment. Examination of the vessel's SMS has show little or no compliance with the SMS. It is highly recommended that the vessel's Administration and RO conduct an ISM audit to ensure proper functioning of the ship's SMS
Due 19 March 2009
Resolved 12 November 2009
Resolution: New owner/operator. All new SMS onboard.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 12 February 2009 Resolved
Because of the number of crew without the proper Flag endorsement, the vessel must complete satisfactory Port State and ISPS evaluations prior to departing the port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: Conducted satisfactory PSC and ISPS Exam.
Personnel › Training › Ship Maneuvering and Handling
Issued 9 February 2009 Resolved
0936-The vessel’s Chief Engineer and no members of the crew that could demonstrate the proper operation of the auxiliary steering gear. It could not be determined if the equipment was operational. The auxiliary gear shall be capable of being brought speedily into action in an emergency. STCW Chap 1, Reg 4.2.4 and SOLAS 60 Chap 2, Reg 29 (a)(ii
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: New Chief Engineer demonstrated proper operation of steering gear.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 27 January 2009 Resolved
1721-The engine room bilge contained 6 feet of slops throughout the entire engine room (>25,000 gallons). This was verified by sounding of the bilges.The vessel’s sludge tank was full (1,373 gallons). The vessel does not have sufficient capacity remaining for its next intended voyage. The excessive amount of oily mixtures presents a significant fire hazard. Marpol 2006 Annex I, Reg 12
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 27 January 2009 Resolved
1730-The vessel’s Chief Engineer was unable to demonstrate the operation of the equipment; furthermore there were no members of the crew that could demonstrate the proper operation of the OWS. Could not be determined if the equipment was operational. Oil filtering equipment shall be as such as will ensure that any oily mixture discharged will not exceed 15 parts per million. STCW Chap 1, Reg 4.2.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: New Chief Engineer properly demonstrated use of OWS.
Electrical › Electric Generation Source (service) › Generator
Issued 27 January 2009 Resolved
1430-The ships service generators speed controllers have been bypassed and do not operate correctly. SOLAS 60 Chap2, Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: New generator was installed and operational.
Navigation › Collision/Grounding Avoidance › Radar
Issued 27 January 2009 Resolved
1530-The ships second Radar as listed on SOLAS Equipment Certificate does not work. All equipment shall be maintained to the conditions at ships survey. SOLAS 60 Chap2, Reg 11
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: All Radars operational.
Electrical › Electric Generation Source (emergency) › Panelboard
Issued 27 January 2009 Resolved
0945-The emergency generator listed on the ships fire control plan is not connected and capable of supplying illumination at launching stations and stowage positions of survival craft. SOLAS 60 Chap2, Reg 26 (b)(iii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: Emergency Generator operational
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 January 2009 Resolved
0810-The emergency switchboard for the emergency generator is not provided with non-conductive mats or gratings to provide protection for the operator. SOLAS 60 Chap2, Reg 27 (a)(ii)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: protection for the operator were in place.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 27 January 2009 Resolved
0420-Ships food stores are inadequate for the size of the crew and duration of the ships voyage. Ships shall have on board food and water supplies. ILO 147 Food and Catering, 2 and COMDTINST 16711.12a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: Adequate food and water supply on board ship.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 27 January 2009 Resolved
0410-Ships freezer is inoperable. Ships equipment shall permit the service of proper meals and shall permit the storage for adequate food supplies. ILO 147 Food and Catering, 3 and COMDTINST 16711.12a
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2009
Resolution: New freezer installed.
Engineering › Diesel Engine (auxiliary) › Distributor (fuel injection)
Issued 6 July 2008 Resolved
Ships service diesel generator #2 had leaking fuel oil coming from the fuel return line on the generator. The leaking fuel was also dripping on a fuel line going into the fuel pump. That fuel line is saturated and should be replaced. SOLAS 60 I Reg. 11
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 August 2008
Resolution: Coast Guard inspector reinspected the defective equipment and found no deficiencies.
Electrical › Electric Generation Source (service) › Generator
Issued 18 April 2008 Resolved
#1 SSDG Shows evidence of not being properly installed or maintained. Loose/exposed wiring is running from the starter, junction box, and both control panels, SSDG has two control panels; one panel is fixed to the generator, the other is hanging by a rope from the overhead. The #1 SSDG overheated and had to be shut down while the PSCOs were on board. Attest to the proper installation/operation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 30 April 2008
Resolution: Flag survey received attesting to proper repairs
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 April 2008 Resolved
The saltwater cooling system for the 1 SSDG has multiple hose and clamp arrangements acting as couplings and an improperly installed 3-way valve in the overboard discharge line. Attest to the proper installation of the saltwater cooling system on the #1SSDG
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2008
Resolved 30 April 2008
Resolution: Flag survey received and repairs completed.
Electrical › Electric Generation Source (emergency) › Generator
Issued 18 April 2008 Resolved
Emergency Generator: Fuel Oil line has steady drip leak at valve and steady lube oil leak.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 April 2008
Resolved 18 April 2008
Resolution: crew rectified problem.
Electrical › Electric Generation Source (emergency) › Generator
Issued 18 April 2008 Resolved
Would not start for initial inspection - valves had been misaligned and fuel lines had drained - crew rectified problem.
Action required: 705 - Other - as specified
Due 18 April 2008
Resolved 18 April 2008
Resolution: crew rectified problem before PSCOs departed.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 23 January 2008 Resolved
Vessel does not have a fixed emergency fire pump installed. Currently the vessel is using a portable pump as the emergency fire pump. This portable pump does not supply two adequate jets of water. SOLAS 60 CH. II-2/ 65(b)(ii)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2008
Resolution: Removed this deficiency and rescinded this item on the vessel''s copy of the Form B dated 23-Jan-08. See narrative for explanation.
Lifesaving › Rescue Boat › Inflated Condition
Issued 23 January 2008 Resolved
The sponson for the rescue boat is not adequately inflated. Vessel crew stated the sponson was inflated prior to departure from previous port but upon arrival in Mobile, AL the sponson had lost inflation. There has been a repair from damage by a crane. SOLAS 60 CH.III/4(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2008
Resolution: Verified the sponson has been holding pressure and is inflated. Recieved letter from the RO attesting to the repairs on the sponson.
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 23 January 2008 Resolved
The ground tackle located on the aft mooring deck, center line, appears to have fractures at the base. The fractures are visible from underneath in the steering room. This presents a flood hazard if the weld seam parts. Complete prior to departure to the satisfaction of the RO. SOLAS 60 CH.I/10
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 January 2008
Resolution: Examined new plate installed and reviewed letter from the RO approving the installation and work being done.
Documentation › Logs/Records › Oil Record Book
Issued 23 January 2008 Resolved
The Oil Record Book is missing entries and has improper entries. Specifically an entry for discharge of sludge to a reception facility is missing for 10-Dec-07 in Miami, FL. Improper entries include using "C-11" codes for transfer of oil residues and "B" codes for internal transfers of fuel oil.
Action required: 705 - Other - as specified
Resolved 23 January 2008
Resolution: Educated the Chief Engineer on proper entries in the ORB
Documentation › Logs/Records › Garbage Recordkeeping
Issued 23 January 2008 Resolved
The Garbage Record Book is missing entries and has improper entries. Specifically an entry for discharge of garbage to a reception facility is missing for 10-Dec-07 in Miami, FL. Improper entries include discharges to reception facilities from NOV 07 - JAN 08. The entry amounts do not match the receipts for amounts received for CAT. 1.
Action required: 705 - Other - as specified
Resolved 23 January 2008
Resolution: Educated the [name withheld] on proper entries for the Garbage Record Book.
Construction/Loadline › Hull › Stiffener
Issued 23 January 2008 Resolved
Several sideshell stiffeners are found to be wasted and holed at the following locations on the main deck: on the port side the second and third stiffeners aft of the forecastle, on the starboard side the first, second, and third stiffeners aft of the forecastle. SOLAS 60 CH.I/10 Complete to the satisfaction of the RO
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2008
Resolution: FLAG SURVEY RECEIVED.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 23 January 2008 Resolved
Found soft patch on the diesel oil line located on the main deck, port side just forward of the superstructure. There does not appear to be a leak currently. Complete to the satisfaction of the RO. SOLAS 60 CH.I/10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 30 April 2008
Resolution: Flag survey received attesting to proper repairs.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 23 January 2008 Resolved
The vessel has not prepared or submitted a Non-Tank Vessel Response Plan to the United States Coast Guard in accordance with the United States Federal Water Pollution Control Act as amended by Section 701 and the Coast Guard Maritime Transportation Act of 2004
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 July 2008
Resolution: Vessels owner verified that the vessel had the Coast Guard approval letter for the non-tank vessel response plan. Deficiency for this has been cleared.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 November 2007 Resolved
Retain oily slops o/b vessel and discharge to an approved disposal facility until demonstration of properly operating oily water separator in the presence of the attending USCG inspector.
Action required: 705 - Other - as specified
Due 16 January 2008
Resolved 23 January 2008
Resolution: Vessel crew demonstrated proper operation of the oily water separator.
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 13 November 2007 Resolved
Provide Flag State approved Cargo Securing Manual.
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 23 January 2008
Resolution: Reviewed approved Cargo Securing Manual.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 November 2007 Resolved
Demonstrate a fully operational navigation bridge. Currently, no power supply is available for approximately 1/2 of the main navigation equipment (GPS, both radars, echo depth sounder, NAVTEX).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2007
Resolution: Def corrected
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 13 November 2007 Resolved
Demonstrate proper operation of emergency fire pump and ensure that EFP is sufficient to provide a steady stream fwd & aft simultaneously.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2007
Resolution: Def corrected
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 7 November 2007 Resolved
Due to change of owner/operator, vessel is to provide copies of all required SOLAS documents and crew licenses/endorsements to Sector Miami for review. Port State control exam to be conducted prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 November 2007
Resolution: Def corrected
Construction/Loadline › Markings › Load Line Mark
Issued 9 July 2007 Resolved
The letters assigned to each freeboard mark were not permanently marked or painted.
Action required: 705 - Other - as specified
Due 8 August 2007
Resolved 16 November 2007
Resolution: Def corrected
Engineering › Steering Gear System › Pump
Issued 14 May 2007 Resolved
Steering pump failed during departure. Pump will need to be replaced.
Action required: 705 - Other - as specified
Resolved 14 May 2007
Resolution: Class survey report faxed attesting to all repairs.
Engineering › Lubricating Oil Service System › Purifier
Issued 16 April 2007 Resolved
Fuel and lube oil seperator or purifier has numerous exposed wires surrounding this area.
Due 16 April 2007
Resolved 17 April 2007
Construction/Loadline › Penetrations › Gasket
Issued 16 April 2007 Resolved
Gasket on emergency generator door is wasted
Action required: 705 - Other - as specified
Due 15 May 2007
Resolved 16 July 2007
Resolution: Received satisfactory class report.
Electrical › Electric Supply System (service) › Cable
Issued 16 April 2007 Resolved
Junction box above main diesel engine for thermostat has exposed and badly spliced wires.
Action required: 15 - Rectify deficiencies by next port
Due 17 April 2007
Resolved 16 July 2007
Resolution: Received satisfactory class report.
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 16 April 2007 Resolved
Vessel does not have an approved fire control plan onboard
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 16 July 2007
Resolution: Received satisfactory class report
Construction/Loadline › Markings › Load Line Assigning Authority Mark
Issued 16 April 2007 Resolved
Plimsol mark does not match loadline certificate.
Action required: 705 - Other - as specified
Due 17 May 2007
Resolved 18 April 2007
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 April 2007 Resolved
EPIRB batter is dead.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 April 2007
Resolved 17 April 2007
Personnel › Certificates/Documents/Licenses › Medical Fitness Document
Issued 17 April 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 24 April 2006
Resolved 17 July 2006
Resolution: CG Inspectors verified def cleared (LT [name withheld], [name withheld], [name withheld])
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 17 April 2006 Resolved
Starboard ship service generator is leaking oil from cylinder head cover onto exhaust line. Make permananent/proper repairs to stop leak.
Action required: 705 - Other - as specified
Due 24 April 2006
Resolved 17 July 2006
Resolution: CG Inspectors verified def cleared (LT [name withheld], [name withheld], [name withheld])
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 17 April 2006 Resolved
Port ship service generator is leaking coolant from main block. Make permanent/proper repairs to stop leak.
Due 24 April 2006
Resolved 17 July 2006
Resolution: CG Inspectors verified def cleared (LT [name withheld], [name withheld], [name withheld])
Stability › Weathertight Integrity › General
Issued 17 April 2006 Resolved
Door accessing A/C spance is bent/damaged and gasket is wasted not allowing a weathertight seal.
Action required: 705 - Other - as specified
Due 1 May 2006
Resolved 17 July 2006
Resolution: CG Inspectors verified def cleared (LT [name withheld], [name withheld], [name withheld])
Navigation › Piloting/Steering › Gyro Compass
Issued 2 August 2004 Resolved
Repair inoperable gyrocompass, prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 16 August 2004
Engineering
Issued 19 April 2004 Resolved
Cooling pipe to main engine needs to be replaced and approved by flag state rep.
Due 5 May 2004
Resolved 11 May 2004
Engineering
Issued 19 April 2004 Resolved
Properly repair fuel lines with soft patches to the satisfaction of flag state rep.
Due 5 May 2004
Resolved 11 May 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 16 June 2003 Resolved
Engine Room CO2 discharge alarm is inop. Repair prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Resolution: Owner sent in fax.
Lifesaving › Lifeboat Equipment
Issued 16 June 2003 Resolved
Vessel has an inop GMDSS life boat radio. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2003
Resolution: Fax sent by owner.
Electrical › Electrical Distribution System (service)
Issued 16 June 2003 Resolved
Dead ended wiring on Emergency Generator and Main Generators. Remove dead ended wiring or terminate in a box. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 7 July 2003
Resolved 7 July 2003
Electrical › Electric Generation Source (emergency)
Issued 16 June 2003 Resolved
Fuel return line on Emergency Generator is not proper. Replace with proper tubing; currently ship is using tubing with a rubber hose in the middle. LEGACY COMPONENT DESC: Fuel Lines
Condition: Placed in Improper Service
Due 7 July 2003
Resolved 7 July 2003
Stability › Watertight Integrity
Issued 13 January 2003 Resolved
Have Class Surveyor address and provide, in writing, a repair proposal for the wasted deck located on the main deck starboard side, forward of the cargo hold.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2003
Resolved 14 January 2003
Fire Fighting › Fire Main
Issued 13 January 2003 Resolved
Have Class surveyor address soft patch in fire main located port side midships. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2003
Resolved 14 January 2003
Electrical › Electrical Distribution System (service)
Issued 13 January 2003 Resolved
Repair or remove deadend wiring throughout the ship: Engine room just outside engine control room, emergency generator room, etc. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 14 January 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 13 January 2003 Resolved
Make permanent storage bracket for acetylene bottles located main deck forward of cargo hold. Class must address and approve the installation. LEGACY COMPONENT DESC: Welding/Hot Work
Action required: 705 - Other - as specified
Due 13 February 2003
Resolved 24 February 2003
Resolution: Inspected sat onboard.
Engineering › Steering Gear System
Issued 14 June 2002 Resolved
Class/Flag to address Rudder Angle Indicator error between the Helm Station Indicator, the indicator on the bridge overhead, and the indicator in the steering flat. LEGACY COMPONENT DESC: Rudder Angle Indicator
Due 28 June 2002
Resolved 25 June 2002
Resolution: Received class report stating differences are within acceptible range.
Pollution Prevention/Response › Prevention Equipment
Issued 14 June 2002 Resolved
Vessel does not have plugs for scuppers onboard. Provide plugs onboard. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Due 28 June 2002
Resolved 8 July 2002
Resolution: Scuppers in place.
Construction/Loadline › Structures
Issued 14 June 2002 Resolved
Weathertight door to galley has opening in it. Make door weathertight. LEGACY COMPONENT DESC: Door
Due 28 June 2002
Resolved 8 July 2002
Resolution: Welded steel insert into place.
Deck/Cargo › Ballast
Issued 14 June 2002 Resolved
Make permanent repairs to gooseneck vent for ballast tank #1 stbd in place of soft patch. LEGACY COMPONENT DESC: Vents
Due 28 June 2002
Resolved 8 July 2002
Resolution: Replaced entire gooseneck vent pipe.
Documentation › Certificates/Documents
Issued 19 May 2002 Resolved
Have Flag & Class address differences in International Tonnage Certificate and all other statuatory certificates. LEGACY COMPONENT DESC: International Tonnage Certificate
Due 19 July 2002
Resolved 25 June 2002
Engineering › Shafting/Propeller Arrangements
Issued 15 December 2001 Resolved
Loss of Propulsion/Power IAW 33 CFR 160.111. Correct to the satisfaction of the Certificate Issuing Authority. LEGACY COMPONENT DESC: Intermediate Shaft
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2001
Resolved 15 December 2001
Resolution: cleared
Documentation
Issued 5 April 2001 Resolved
Provide a valid safety Radio certificate.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Fire Fighting
Issued 5 April 2001 Resolved
Prior to departure provide fire suit to fit fire fighter IAW assigned Muster List or reasign a smaller man to that position. Corrected on the spot.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 5 April 2001 Resolved
Provide fixed fuel oil containment for port and stbd #7 tank vents and day tank vents on stbd side. Vsl made temp repairs and must make permanent repairs by 28APR01.
Condition: Unknown
Due 11 May 2001
Resolved 11 May 2001
Lifesaving
Issued 5 April 2001 Resolved
Prior to departure provide 15 life jackets (solas type) and fax receipt to MSO Miami.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Navigation
Issued 9 September 1999 Resolved
Prior to 09OCT99, commence making chart and nautical publications corrections with notice to mariners.
Condition: Unknown
Due 7 January 2000
Resolved 7 January 2000
Navigation
Issued 9 September 1999 Resolved
Prior to arrival in next U.S. port, provide new magnetic compass deviation table.
Condition: Unknown
Due 7 January 2000
Resolved 7 January 2000
Fire Fighting
Issued 9 September 1999 Resolved
Prior to 09OCT99, repair bracket and properly mount fire extinguisher in emergency generator room.
Condition: Unknown
Due 7 January 2000
Resolved 7 January 2000
Electrical
Issued 9 September 1999 Resolved
Prior to 09OCT99 properly secure portable battery charger in emergency generator room.
Condition: Unknown
Due 7 January 2000
Resolved 7 January 2000
Accommodation/Occupational Safety
Issued 9 September 1999 Resolved
Prior to 09OCT99, provide nameplate or certification letter for marine sanitation device.
Condition: Unknown
Due 8 January 2000
Resolved 21 January 2000
Documentation
Issued 9 September 1999 Resolved
Prior to 09OCT99 provide flag approved stability book.
Condition: Unknown
Due 27 January 2000
Resolved 26 January 2000
Accommodation/Occupational Safety
Issued 9 September 1999 Resolved
Prior to 09OCT99, provide operating instructions or manual for marine sanitation device.
Condition: Unknown
Due 8 January 2000
Resolved 21 January 2000
Navigation
Issued 9 September 1999 Resolved
Prior to 09OCT99, commence logging and conducting emergency steering drills.
Condition: Unknown
Due 7 January 2000
Resolved 7 January 2000
Navigation
Issued 7 August 1998 Resolved
Provide on board, current & corrected NOAA Chart 11470, USCP 4, and Lightlist IAW SOLAS 74 CH V/20, prior to departure.
Condition: Unknown
Due 7 August 1998
Resolved 8 August 1998
Lifesaving
Issued 7 August 1998 Resolved
Replace 2nd from bottom step on pilot ladder IAW SOLAS 74 CH V/17, prior todeparture.
Condition: Unknown
Due 7 August 1998
Resolved 8 August 1998
Lifesaving
Issued 7 August 1998 Resolved
Provide 1 more line throwing unit to comply with the require 4 IAW SOLAS 60CH III/23, proir to departure.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Documentation
Issued 7 August 1998 Resolved
Commence logging of weekly test of general alarm IAW SOLAS 74 Chapter III/19.6.3, starting today, 07AUG98.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Documentation
Issued 7 August 1998 Resolved
Provide on board, a ship's Master with a valid certificate IAW STCW 78 I/10, proir to departure. If Cert. is not issued by vessel's Flag Administration, provide documentation from vessel's Flag Admin. indicating subject Cert. is acceptable.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Documentation
Issued 7 August 1998 Resolved
Commence logging of life-saving appliance inspections, both weekly and monthly IAW SOLAS 74 CH III/19.6 & 19.7, starting today, 07AUG98.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Electrical
Issued 7 August 1998 Resolved
Repair/replace start button for emergency generator IAW SOLAS 74 CH II/26, no later than 28AUG98.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Fire Fighting
Issued 7 August 1998 Resolved
Make permanent repairs to firemain & prove proper operation IAW SOLAS 74 CHII-2/21, prior to departure.
Condition: Unknown
Due 7 August 1998
Resolved 8 August 1998
Lifesaving
Issued 7 August 1998 Resolved
Provide embarcation ladder for port side liferaft IAW SOLAS 74 CH III/19, prior to departure.
Condition: Unknown
Due 7 August 1998
Resolved 8 August 1998
Lifesaving
Issued 7 August 1998 Resolved
Properly install the hydrostatic release unit on the STBD liferaft, IAW SOLAS 74 CH III/19, proir to departure.
Condition: Unknown
Due 7 August 1998
Resolved 7 August 1998
Lifesaving
Issued 7 August 1998 Resolved
Replace rescue boat first aid kit IAW SOLAS 74 CH III/19, prior to departure.
Condition: Unknown
Due 7 August 1998
Resolved 8 August 1998
Engineering
Issued 23 January 1998 Resolved
Prior to 23FEB98, make proper repair to lube oil vent pipe in way of duct tape.
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Navigation
Issued 23 January 1998 Resolved
Prior to 23FEB98, provide corrected charts of local area.
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Engineering
Issued 23 January 1998 Resolved
Prior to 23FEB98, provide a plug for starboard side fuel/lube oil containment
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Construction/Loadline
Issued 23 January 1998 Resolved
Prior to 23FEB98, paint loadline a contrasting color to the hull IAW the vessels Loadline certificate.
Condition: Unknown
Due 27 February 1998
Resolved 27 February 1998
Deck/Cargo
Issued 23 January 1998 Resolved
Prior to 23FEB98, make permanent repair to the speed control handles on theanchor windlass.
Condition: Unknown
Due 12 March 1998
Resolved 10 April 1998
Fire Fighting
Issued 18 July 1997 Resolved
UPDATE FIREPLAN TO REFLECT REQUIREMENTS OF SOLAS 74 CH II-2 REG. 20.
Condition: Unknown
Due 12 August 1997
Resolved 12 August 1997
Documentation
Issued 26 June 1997 Resolved
MUST PROVIDE CURRENT MEDICAL CERTIFICATES FOR ALL CREW, AS PER ILO 147.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Navigation
Issued 26 June 1997 Resolved
GYROCOMPASS IS 4 DEGREES OFF. MUST ADJUST AND PROVIDE SERVICE REPORT PRIORTO NEXT US PORT, AS PER SOLAS 74 CH V, REG 12.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Fire Fighting
Issued 26 June 1997 Resolved
FIRE PLAN DID NOT FULLY COMPLY WITH SOLAS 74, CH II-2, REG 20. MUST UPDATEAND HAVE CLASS APPROVED BY 27JUL97.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 26 June 1997 Resolved
PROVIDE MUSTER LIST AND EMERGENCY INSTRUCTIONS IN LANGUAGE UNDERSTOOD BY THE CREW (SPANISH)
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Accommodation/Occupational Safety
Issued 26 June 1997 Resolved
REMOVE R-12 CAN FROM CHILL SYSTEM TO MEAT LOCKER.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Lifesaving
Issued 26 June 1997 Resolved
PROVIDE COVERS FOR BELTS ON AIR COMPRESSORS AND FRESH WATER PUMP.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Navigation
Issued 26 June 1997 Resolved
PROVIDE SAFETY SHIELD FOR #1 HYDRAULIC STEERING PUMP COUPLING SHAFT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Engineering
Issued 26 June 1997 Resolved
CROP AND RENEW VENTS FOR #7 PORT AND STBD. DIESEL TANKS.
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Documentation
Issued 26 June 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 July 1997
Resolved 18 July 1997
Fire Fighting
Issued 31 May 1996 Resolved
UPDATE FIRE CONTROL PLAN TO INDICATE LOCATION OF SHORE CONNECTION AND FIRE PROTECTION EQUIPMENT IN THE FWD MACHINERY SPACE._x001C_
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Fire Fighting
Issued 31 May 1996 Resolved
REPAIR FIRE ALARM CALL SYSTEM._x001C_
Condition: Unknown
Due 28 August 1996
Resolved 19 September 1996
Fire Fighting
Issued 31 May 1996 Resolved
PROVIDE REQUIRED PORTABLE FIRE PROTECTION EQUIPMENT TO FWD MACHINERY SPACE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1996
Resolved 7 June 1996
Unknown
Issued 19 December 1995 Resolved
PRIOR TO NEXT U.S PORT, PROVIDE CLASS REPORT OF ACCEPTANCE OF NEW RUDDER AND PROOF OF STEERING TEST BEING CONDUCTED.
Condition: Unknown
Due 3 January 1996
Resolved 3 January 1996
Construction/Loadline
Issued 2 June 1995 Resolved
APPLY BOLTS TO FOREPEAK COVER
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Electrical
Issued 2 June 1995 Resolved
REMOVE LIVE WIRES (24V) BETWEEN BATTERIES FOR GENERATORS FORWARD
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Navigation
Issued 2 June 1995 Resolved
PROVIDE CURRENT CHARTS UPDATED TO LOCAL NOTICE TO MARINERS
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Navigation
Issued 2 June 1995 Resolved
PROVIDE 1995 EDITIONS OF : US COAST PILOT_x001C_ COAST GUARD LIGHT LIST_x001C_ INLAND NAV RULES
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Accommodation/Occupational Safety
Issued 2 June 1995 Resolved
SUPPORT DECK PLATING IN ENGINE ROOM FORWARD OF MAIN ENGINE
Condition: Unknown
Due 11 July 1995
Resolved 11 July 1995
Documentation
Issued 2 June 1995 Resolved
PROVIDE MEDICAL CERTIFICATES FOR ALL CREW MEMBERS
Condition: Unknown
Due 11 July 1995
Resolved 11 July 1995
Construction/Loadline
Issued 2 June 1995 Resolved
REPAIR WASTED HATCH COVER ON BOW
Condition: Unknown
Due 21 July 1995
Resolved 11 September 1995
Documentation
Issued 2 June 1995 Resolved
PROVIDE SAFE MANNING CERTIFICATE AND PROVIDE DOCMENTATION FROM FLAG THAT VESSEL IS SUFFICIENTLY AND EFFICIENTLY MANNED.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Documentation
Issued 2 June 1995 Resolved
PROVIDE VALID SAFETY RADIO CERTIFICATE
Condition: Unknown
Due 11 July 1995
Resolved 11 July 1995
Fire Fighting
Issued 2 June 1995 Resolved
PROVIUDE CYLINDERS FOR BREATHING APPARATUS
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Documentation
Issued 2 June 1995 Resolved
PROVIDE EVIDENCE OF ANNUAL ENDORSEMENT BY CLASS SOCIETY FOR IOPP, LOADLINE,AND SAFETY CONSTRUCTION CERTIFICATES.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Electrical
Issued 2 June 1995 Resolved
REPAIR REMOTE OPERATION OF GENERATOR CIRCUIT BREAKERS_x001C_ (NOTIFY CLASS SOCIETY [B.V.] OF CONDITION )
Condition: Unknown
Due 11 July 1995
Resolved 11 July 1995
Lifesaving
Issued 2 June 1995 Resolved
PROVIDE DOCUMENTATION FROM SERVICING FACILITY THAT LIFERAFT HYDROSTATIC RELEASE UNITS HAVE HAD ANNUAL INSPECTION
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Lifesaving
Issued 2 June 1992 Resolved
The vessel was doing hotwork in the cargo hold, which was open to the maindeck, while they were taking on #2 diesel oil. The vessel is in violation of 33 CFR 126.13(b) in that they were handling dangerous cargo, diesel fuel, and conducting hotwork.
Condition: Unknown
Due 10 August 1992
Resolved 10 August 1992

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.