MAURY USCG vessel records Sign in
← All vessels

TRANSPINE

TRANSPINE is a 2002 freight ship. The Coast Guard has recorded 27 inspections since 1984, most recently in July 2011, along with 12 deficiencies and 4 operational controls.

Records from 1984 to 2011. Most recent: inspection, 20 July 2011.

Built
2002
Last inspected
20 July 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9216638 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222625
Flag
SWEDEN
—
Maury page id
psix-222625

Inspections, by type

…with no type recorded9
Years with a record 11 calendar years (1984–2011)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it20851 - Convention (Subpart B), Gross Ton
18100 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

20 July 2011 PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4088035
25 January 2011 Deficiency Check
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3933435
7 January 2011 ISPS III Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3922380
18 October 2010 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3872247
28 July 2008 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3282344
29 May 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3221027
4 October 2007 Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3072790
12 June 2007 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2959088
6 July 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2703745
9 May 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2644441
13 February 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2584467
10 November 2005 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2532165
24 January 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2280419
13 October 2004 NPV Safety Exam · ISPS III Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2219756
21 August 2004 NPV Safety Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2172185
8 July 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2126435
7 July 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2124373
18 May 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2076419
25 December 2003 Administrative Inspection
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1975111
23 December 2003 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1968738
29 May 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1798970
29 May 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1804770
21 April 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1777885
6 March 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1491695
15 November 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 305738
6 May 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 471562
8 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 299257

Deficiency record · 12

Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 January 2011 Resolved
One half of the total number of lifebuoys shall be self-igniting lights. Two of the self-igniting lights are inoperable.
Condition: Improper/Lack of Maintenance
Due 7 January 2011
Resolved 7 January 2011
Resolution: The ship ordered and received new lights prior to the end of the inspection.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 January 2011 Resolved
The electrical installation where the accumulator batteries for the reserve source of energy (battery room for radio installations) is unsafe. The explosion proof lighting was found partially disassembled and the light is not working, which is a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 January 2011
Resolution: Lighting has been properly repaired and was operational at time of re-inspection.
Construction/Loadline › Structures › Superstructure
Issued 29 May 2008 Resolved
Crew is extending catwalk and railing on deck nine (9) to facilitate the on load of stores. Class to attest to the modifications. ICLL 02 Part I/15
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 July 2008
Resolution: Received flag state report attesting to the modifications of catwalk on deck nine (9).
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 9 May 2006 Resolved
While conducting steering gear test it was noted that the rudder angle indicator on the bridge varied from the rudder angle indicator on the steering gear by 06 degress. The indicator showed 35 degr.on the bridge and 41 degr. on the steering gear. Captain to place warning note for pilots stating the variance in the rudder angle indicators. Violation of SOLAS 74A 2004 Chapter II-I Reg. 29 11.1
Action required: 705 - Other - as specified
Due 16 May 2006
Resolved 6 July 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2006 Resolved
Vessel is missing 07 protective light covers in the engine control room. Violation of ILO 147 Rectify within 30 days to the satisfaction of class
Action required: 705 - Other - as specified
Due 9 June 2006
Resolved 6 July 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 24 January 2005 Resolved
MSO PHILADEPHIA ISSUED LOD 05 - 05 TO M/V FINNPINE FOR INOPERABLE X-BAND RADAR
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2005
Resolved 26 January 2005
Resolution: INOP X-BAND RADAR WAS INSPECTED AND TESTED TO THE SATISFACTION OF THE REPAIR TECH. MSO PHILADELPHIA RESCINDED LOD 05 - 05.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 May 2004 Resolved
inop radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2004
Resolved 21 May 2004
Resolution: inspected and tested to the satisfaction of the repair technician.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 25 December 2003 Resolved
Vessel lost stbd anchor and chain.
Condition: Unknown
Due 1 March 2004
Resolved 21 August 2004
Resolution: Received Class Report attesting to the correction of the deficiency.
Fire Fighting › Combustible Materials
Issued 21 April 2003 Resolved
Oil soaked lagging located on pipes next to bunker fuel filter and behind the heavy fuel oil pumping mechanism. Oil soaked lagging presents a fire hazard. Solas 74/78, Ch. II-2, Reg. 15.2. Correct prior to next U.S. port after sailing foreign or within 30 days. LEGACY COMPONENT DESC: Insulation
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 May 2003
Resolved 29 May 2003
Resolution: Oil soaked lagging has been replaced with new.
Fire Fighting › International Shore Connection
Issued 21 April 2003 Resolved
International shore connection is missing a rubber gasket. Gasket must be stored with shore connection. Solas 74/78, Ch. II-2, Reg. 19.4. Correct prior to next U.S. port after sailing foreign or within 30 days. LEGACY COMPONENT DESC: Gasket
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 May 2003
Resolved 29 May 2003
Resolution: New gasket has been placed with the international shore connection.
Navigation
Issued 15 November 1985 Resolved
33 CFR 164.30: VESSEL WAS OPERATING WITHOUT A TIDAL CURRENT TABLES REQUIREDBY 33 CFR 164.33(A)(3)(II).
Condition: Unknown
Due 16 November 1985
Resolved 15 November 1985
Navigation
Issued 8 December 1984 Resolved
NOS CHARTS 18746,18749,18751 NOT CORRECTED UP TO DATE. TIDAL CURRENT TABLES WEST COAST NOT ON BOARD.
Condition: Unknown
Due 8 December 1984
Resolved 8 December 1984

Ownership record