Records from 1985 to 1994. Most recent: inspection, 9 March 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
9 March 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 689199
4 March 1994
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 854881
1 April 1992
Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1266429
23 November 1988
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1206417
22 November 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 326966
25 August 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 488926
7 January 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 320705
7 January 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011398
7 January 1988
MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011402
15 June 1986
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1326887
3 June 1986
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 536543
3 June 1986
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1326884
17 March 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994267
12 March 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 307713
21 October 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 304903
21 October 1985
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 994864
Fire Fighting
Issued 4 March 1994
Resolved
PRIOR TO TRANSFER CARGO IN U.S. PORT, PROVIDE A CLASS SOCIETY REPORT TO DETERMINE IF STEAM SMOTHERING SYSTEM IS REQUIRED OR ADEQUATED.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Lifesaving
Issued 1 April 1992
Resolved
ENSURE PROPER OPERATION OF WATER LIGHTS ON ALL RING LIFE BOUYS
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Engineering
Issued 1 April 1992
Resolved
ENSURE PROPER OPERATION OF OILY WATER SEPARATOR ELECTRONIC MONITOR/AND ASSOCIATED ALARM
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 1 April 1992
Resolved
REPLACE FLAME SCREENS ON CARGO TANK VENT HEADERS
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 1 April 1992
Resolved
TEST IGS SYSTEM, IN NEXT U.S. PORT, WHEN AND IF, CARRYIN A PRODUCT REQUIRING IGS
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 7 January 1988
Resolved
STARBOARD CARGO DISCHARGE CONTAINMENT HAS NO MECHANICAL MEANS OF CLOSING THE DRAIN.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Engineering
Issued 7 January 1988
Resolved
VESSEL'S 15PPM OILY WATER SEPERATOR ALARM DIRECTIONAL CONTROL VALVE WAS NOTOPERATING PROPERLY.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Deck/Cargo
Issued 7 January 1988
Resolved
VESSEL'S STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING SYSTEM WAS CONDUC-TED IMPROPERLY (NOT DONE TO THE CORRECT PRESSURE).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 7 January 1988
Resolved
VESSEL'S ONE MONTH TEMPORARY IOPP HAD EXPIRED AND THE VESSEL FAILED TO CON-TACT IT'S CLASSIFICATION SOCIETY TO OBTAIN THE PERMANENT IOPP CERTIFICATE.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Deck/Cargo
Issued 7 January 1988
Resolved
UNABLE TO TEST INERT GAS SYSTEM DUE TO FREEZING OF OXYGEN SENSOR AND INABILITY TO CALIBRATE SYSTEM. PRIOR TO RETURNING TO U.S. WATERS CONDUCT TESTS OF IGS AND LOG THE SATISFACTORY RESULTS OF THESE TESTS IN THE VESSELS LOG.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Fire Fighting
Issued 7 January 1988
Resolved
COMPLETE REPAIRS TO EMERGENCY FIRE PUMP PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Unknown
Issued 17 March 1986
Resolved
REMOVE OIL RESIDUE FROM ENGINE ROOM BILGES PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Fire Fighting
Issued 17 March 1986
Resolved
MAKE PERMANENT REPAIRS TO SOFT PATCHES IN SLOP LINES STBD MAIN DECK AND FIRE MAIN PAST MAIN DECK PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986
Resolved
RENEW WASTED DECK PLATES LOWER CARGO PUMP ROOM PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Fire Fighting
Issued 17 March 1986
Resolved
ALL FIRE EXTINGUISHING EQUIPMENT MUST BE SERVICED BY AN AUTHORIZED FACILITYPRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Deck/Cargo
Issued 17 March 1986
Resolved
HYDRO TEST ALL CARGO & BUNKER PIPING TO 1.5 MAWP PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Documentation
Issued 17 March 1986
Resolved
PROVIDE COMPLETE OIL TRANSFER PROCEDURES PRIOR TO OFF LOADING CARGO 16MAR86.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986
Resolved
PROVIDE PROOF THAT PORTABLE RADIOS ARE INTRINSICALLY SAFE PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Deck/Cargo
Issued 17 March 1986
Resolved
MAKE PROPER REPAIRS TO DRESSER COUPLINGS IN CARGO AND BUNKER PIPING PORT & STBD MAIN DECK PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986
Resolved
MAKE PROPER REPAIRS TO LADDERS & VENT DUCTS FORWARD PUMP ROOM PRIOR TO NEXTU.S. PORT. (NOTE: NOT IN CARGO PUMP ROOM).
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986
Resolved
REPAIR SCREENS IN GALLEY AND ACOMODATION VENTS ON FANTAIL PROIR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Deck/Cargo
Issued 12 March 1986
Resolved
EXCESSIVE PRODUCT IN PUMPROOM BILGE.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Engineering
Issued 12 March 1986
Resolved
OILY WATER SEPARATOR FOR ENGINE ROOM SPACES INOPERATIVE. THE OWS WAS DISASSEMBLED.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Engineering
Issued 12 March 1986
Resolved
BUNKER CONTAINMENT FORWARD STARBOARDSIDE CRUSHED
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Electrical
Issued 12 March 1986
Resolved
CARGO PUMP EMERGENCY SHUTDOWNS INOPERABLE. SHUTDOWNS ON THE PORT AND STARBOARD CARGO PUMPS WERE WIRED IN THE RUN POSITION.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Deck/Cargo
Issued 12 March 1986
Resolved
PUMP ROOM FIRE DAMPERS INOPERABLE. STARBOARD FIRE DAMPERS CONTROL ROD WAS FROZEN WITH RUST AND COULD NOT BE TURNED.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Documentation
Issued 12 March 1986
Resolved
NO RECORD OF HYDROSTATIC TESTS FOR THE VESSELS CARGO AND BUNKERING PIPING.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Fire Fighting
Issued 12 March 1986
Resolved
EMERGENCY FIRE PUMP INOPERABLE. PRIME MOVER WAS REMOVED FOR REPAIRS.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Engineering
Issued 12 March 1986
Resolved
VESSEL PERSONNEL DRAINING MACHINERY OIL INTO BILGE.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Fire Fighting
Issued 12 March 1986
Resolved
FIRE STATIONS NOT PROPERLY EQUIPPED. NO FIRE HOSES OR NOZZLES WERE FOUND AT MANY OF THE FIRE STATIONS ON DECK.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Deck/Cargo
Issued 12 March 1986
Resolved
FLAME SCREENS IN PRESSURE VACUUM VALVES WERE WASTED.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Deck/Cargo
Issued 12 March 1986
Resolved
SOFT PATCHES IN NUMBER ONE AND NUMBER TWO CARGO PUMP DISCHARGE LINES.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Documentation
Issued 12 March 1986
Resolved
VESSEL HAD NO OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Unknown
Issued 21 October 1985
Resolved
THE OUTSTANDING ITEMS OF ABS IGS SURVEY DATED 17JAN84 (PG. 12) SHALL BE CORRECTED/COMPLETED.
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985
Unknown
Issued 21 October 1985
Resolved
THE IGS SHALL EITHER BE CERTIFIED BY THE FLAG ADMINISTRATION TO BE IN COMPLIANCE WITH REGULATION 62 OF SOLAS 74 OR BROUGHT INTO STRICT COMPLIANCEWITH 46 CFR 32.53.
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985