MAURY USCG vessel records Sign in
← All vessels

BRAHMS

BRAHMS is a 1972 tank ship. The Coast Guard has recorded 16 inspections since 1985, most recently in March 1994, along with 35 deficiencies.

Records from 1985 to 1994. Most recent: inspection, 9 March 1994.

Built
1972
Last inspected
9 March 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7127950 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222628
Flag
CYPRUS
—
Maury page id
psix-222628

Inspections, by type

…with no type recorded9
Years with a record 5 calendar years (1985–1994)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28557 - Simplified, Gross Ton
17680 - Simplified, Net Ton
48825 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

9 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 689199
4 March 1994 Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 854881
1 April 1992 Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1266429
23 November 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1206417
22 November 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 326966
25 August 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 488926
7 January 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 320705
7 January 1988 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011398
7 January 1988 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1011402
15 June 1986 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1326887
3 June 1986 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 536543
3 June 1986 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1326884
17 March 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 994267
12 March 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 307713
21 October 1985 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 304903
21 October 1985 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 994864

Deficiency record · 35

Fire Fighting
Issued 4 March 1994 Resolved
PRIOR TO TRANSFER CARGO IN U.S. PORT, PROVIDE A CLASS SOCIETY REPORT TO DETERMINE IF STEAM SMOTHERING SYSTEM IS REQUIRED OR ADEQUATED.
Condition: Unknown
Due 8 March 1994
Resolved 8 March 1994
Lifesaving
Issued 1 April 1992 Resolved
ENSURE PROPER OPERATION OF WATER LIGHTS ON ALL RING LIFE BOUYS
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Engineering
Issued 1 April 1992 Resolved
ENSURE PROPER OPERATION OF OILY WATER SEPARATOR ELECTRONIC MONITOR/AND ASSOCIATED ALARM
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 1 April 1992 Resolved
REPLACE FLAME SCREENS ON CARGO TANK VENT HEADERS
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 1 April 1992 Resolved
TEST IGS SYSTEM, IN NEXT U.S. PORT, WHEN AND IF, CARRYIN A PRODUCT REQUIRING IGS
Condition: Unknown
Due 1 April 1992
Resolved 1 April 1992
Deck/Cargo
Issued 7 January 1988 Resolved
STARBOARD CARGO DISCHARGE CONTAINMENT HAS NO MECHANICAL MEANS OF CLOSING THE DRAIN.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Engineering
Issued 7 January 1988 Resolved
VESSEL'S 15PPM OILY WATER SEPERATOR ALARM DIRECTIONAL CONTROL VALVE WAS NOTOPERATING PROPERLY.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Deck/Cargo
Issued 7 January 1988 Resolved
VESSEL'S STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING SYSTEM WAS CONDUC-TED IMPROPERLY (NOT DONE TO THE CORRECT PRESSURE).
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 7 January 1988 Resolved
VESSEL'S ONE MONTH TEMPORARY IOPP HAD EXPIRED AND THE VESSEL FAILED TO CON-TACT IT'S CLASSIFICATION SOCIETY TO OBTAIN THE PERMANENT IOPP CERTIFICATE.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Deck/Cargo
Issued 7 January 1988 Resolved
UNABLE TO TEST INERT GAS SYSTEM DUE TO FREEZING OF OXYGEN SENSOR AND INABILITY TO CALIBRATE SYSTEM. PRIOR TO RETURNING TO U.S. WATERS CONDUCT TESTS OF IGS AND LOG THE SATISFACTORY RESULTS OF THESE TESTS IN THE VESSELS LOG.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Fire Fighting
Issued 7 January 1988 Resolved
COMPLETE REPAIRS TO EMERGENCY FIRE PUMP PRIOR TO RETURNING TO U.S. WATERS.
Condition: Unknown
Due 7 January 1988
Resolved 7 January 1988
Unknown
Issued 17 March 1986 Resolved
REMOVE OIL RESIDUE FROM ENGINE ROOM BILGES PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Fire Fighting
Issued 17 March 1986 Resolved
MAKE PERMANENT REPAIRS TO SOFT PATCHES IN SLOP LINES STBD MAIN DECK AND FIRE MAIN PAST MAIN DECK PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986 Resolved
RENEW WASTED DECK PLATES LOWER CARGO PUMP ROOM PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Fire Fighting
Issued 17 March 1986 Resolved
ALL FIRE EXTINGUISHING EQUIPMENT MUST BE SERVICED BY AN AUTHORIZED FACILITYPRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Deck/Cargo
Issued 17 March 1986 Resolved
HYDRO TEST ALL CARGO & BUNKER PIPING TO 1.5 MAWP PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Documentation
Issued 17 March 1986 Resolved
PROVIDE COMPLETE OIL TRANSFER PROCEDURES PRIOR TO OFF LOADING CARGO 16MAR86.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986 Resolved
PROVIDE PROOF THAT PORTABLE RADIOS ARE INTRINSICALLY SAFE PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Deck/Cargo
Issued 17 March 1986 Resolved
MAKE PROPER REPAIRS TO DRESSER COUPLINGS IN CARGO AND BUNKER PIPING PORT & STBD MAIN DECK PRIOR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986 Resolved
MAKE PROPER REPAIRS TO LADDERS & VENT DUCTS FORWARD PUMP ROOM PRIOR TO NEXTU.S. PORT. (NOTE: NOT IN CARGO PUMP ROOM).
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Unknown
Issued 17 March 1986 Resolved
REPAIR SCREENS IN GALLEY AND ACOMODATION VENTS ON FANTAIL PROIR TO RETURN TO NEXT U.S. PORT.
Condition: Unknown
Due 17 March 1986
Resolved 17 March 1986
Deck/Cargo
Issued 12 March 1986 Resolved
EXCESSIVE PRODUCT IN PUMPROOM BILGE.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Engineering
Issued 12 March 1986 Resolved
OILY WATER SEPARATOR FOR ENGINE ROOM SPACES INOPERATIVE. THE OWS WAS DISASSEMBLED.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Engineering
Issued 12 March 1986 Resolved
BUNKER CONTAINMENT FORWARD STARBOARDSIDE CRUSHED
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Electrical
Issued 12 March 1986 Resolved
CARGO PUMP EMERGENCY SHUTDOWNS INOPERABLE. SHUTDOWNS ON THE PORT AND STARBOARD CARGO PUMPS WERE WIRED IN THE RUN POSITION.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Deck/Cargo
Issued 12 March 1986 Resolved
PUMP ROOM FIRE DAMPERS INOPERABLE. STARBOARD FIRE DAMPERS CONTROL ROD WAS FROZEN WITH RUST AND COULD NOT BE TURNED.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Documentation
Issued 12 March 1986 Resolved
NO RECORD OF HYDROSTATIC TESTS FOR THE VESSELS CARGO AND BUNKERING PIPING.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Fire Fighting
Issued 12 March 1986 Resolved
EMERGENCY FIRE PUMP INOPERABLE. PRIME MOVER WAS REMOVED FOR REPAIRS.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Engineering
Issued 12 March 1986 Resolved
VESSEL PERSONNEL DRAINING MACHINERY OIL INTO BILGE.
Condition: Unknown
Due 12 March 1986
Resolved 12 March 1986
Fire Fighting
Issued 12 March 1986 Resolved
FIRE STATIONS NOT PROPERLY EQUIPPED. NO FIRE HOSES OR NOZZLES WERE FOUND AT MANY OF THE FIRE STATIONS ON DECK.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Deck/Cargo
Issued 12 March 1986 Resolved
FLAME SCREENS IN PRESSURE VACUUM VALVES WERE WASTED.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Deck/Cargo
Issued 12 March 1986 Resolved
SOFT PATCHES IN NUMBER ONE AND NUMBER TWO CARGO PUMP DISCHARGE LINES.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Documentation
Issued 12 March 1986 Resolved
VESSEL HAD NO OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 17 March 1986
Resolved 12 March 1986
Unknown
Issued 21 October 1985 Resolved
THE OUTSTANDING ITEMS OF ABS IGS SURVEY DATED 17JAN84 (PG. 12) SHALL BE CORRECTED/COMPLETED.
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985
Unknown
Issued 21 October 1985 Resolved
THE IGS SHALL EITHER BE CERTIFIED BY THE FLAG ADMINISTRATION TO BE IN COMPLIANCE WITH REGULATION 62 OF SOLAS 74 OR BROUGHT INTO STRICT COMPLIANCEWITH 46 CFR 32.53.
Condition: Unknown
Due 21 October 1985
Resolved 21 October 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.