MAURY USCG vessel records Sign in
← All vessels

CAPTA SPYROS

CAPTA SPYROS is a 1972 freight ship. The Coast Guard has recorded 13 inspections since 1984, most recently in July 1995, along with 30 deficiencies and 1 operational control.

Records from 1984 to 1995. Most recent: operational control imposed, 17 July 1995.

Built
1972
Last inspected
16 July 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7203376 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222660
Flag
GREECE
—
Maury page id
psix-222660

Inspections, by type

…with no type recorded13
Years with a record 8 calendar years (1984–1995)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13120 - Convention (Subpart B), Gross Ton
23236 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 13

16 July 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 380654
15 February 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 182524
2 December 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347390
2 May 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 336738
3 April 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 329049
20 March 1989 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 329185
14 September 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 458988
15 March 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 321998
11 September 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 520782
22 January 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 313926
19 May 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 308950
9 May 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 308732
8 November 1984 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 298769

Deficiency record · 30

Fire Fighting
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING FIRE FIGHTING SPRAY NOZZLES HAVE BEEN PROVIDED AT EACH FIRE HOSE STATION IN THE MACHINERY SPACES.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Engineering
Issued 16 July 1995 Resolved
PRIOR TO CONDUCTING BUNKERING OPERATIONS IN U.S. WATERS PROVIDE DOCUMENTATION TO THE COGNIZANT [name withheld] OF THE TEST REQUIREDBY 33 CFR 156.170 ON THE BUNKER PIPING SYSTEM (1 1/2 TIMES MAWP).
Condition: Unknown
Due 18 July 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT OF PROPER OPERATION OF THE OILY WATER SEPARATOR.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Lifesaving
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT THAT THE GLASS COVER FOR THE #2 EMERGENCY STOPSWITCH LOCATED IN THE PORT MAIN ACCOMMODATION HOUSE PASSAGEWAY HAS BEEN INSTALLED.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Engineering
Issued 16 July 1995 Resolved
PRIOR TO CONDUCTING BUNKER OPERATIONS IN U.S. WATERS DEMONSTRATE TO A COASTGUARD REPRESENTATIVE THE BUNKER TRANSFER PROCEDURES MEET 33 CFR 155.750 OR PROVIDE A COPY TO THE COGNIZANT OCMI.
Condition: Unknown
Due 18 July 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT FOR REPAIR TO WASTED STEPS IN WAY OF THE LADDER BETWEEN THE 01 AND 02 DECK LOCATED ON THE AFT END OF THE ACCOMMODATION HOUSE.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Construction/Loadline
Issued 16 July 1995 Resolved
PROVIDE CLASS REPORT FOR INSTALLATION OF MISSING BOW COMPARTMENT HATCH COVER SECURING DEVICES.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Lifesaving
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT FOR WITNESS OF LIFEBOAT BEING OPERATED IN THE WATER WITHIN THE PAST 3 MONTHS.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Construction/Loadline
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT FOR REPAIRS TO STBD, AFT, MAIN DECK C02 COMPARTMENT WATERTIGHT DOOR CLOSURE/TIGHTNESS.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Fire Fighting
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT WITNESSING OPERATION OF ADEQUATE EMERGENCY FIRE PUMP WATER STREAM.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Fire Fighting
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT FOR ALL ITEMS NEEDED FOR THE INTERNATIONAL SHORE CONNECTIONS HAVE BEEN PROVIDED (GASKET & 4 BOLTS, WASHERS & NUTS).
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Fire Fighting
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT WITNESSING FIRE STATION #6 HAS ALL REQ'D EQUIPMENT (MISSING NOZZLE & SPANNER WRENCH).
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Lifesaving
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING LIFERING BUOY WATERLIGHT STBD SIDE MAIN DECK IS OPERATIONAL.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Fire Fighting
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT FOR UPDATING ALL FIRE PLANS WITH CURRENT VESSEL NAME.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Lifesaving
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT THAT TWO COMPLETE FIRE SUITS HAVE BEEN PROVIDED.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Lifesaving
Issued 16 July 1995 Resolved
PROVIDE CLASS REPORT INDICATING TWO COMPLETE SELF-CONTAINED BREATHING APPARATUS (SCBA) HAVE BEEN PROVIDED.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Lifesaving
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING TWO ELECTRIC LANTERNS HAVE BEEN PROVIDED FOR THE FIREMAN OUTFITS.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Lifesaving
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT WITNESS PROPER OPERATION OF STBD LIFEBOAT ENGINE (STALLS IN NEUTRAL).
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Fire Fighting
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT OF SERVICE TECHNICIAN EXAMINING AND SERVICING THE CARGO HOLD CO2 FIXED CYLINDERS IN WAY OF TWO WITH TWISTED FLEX LOOPS AND ONE WITH THE FLEX LOOP BROKEN OFF.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Construction/Loadline
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT FOR REPAIRS TO THE MAIN DECK ACCOMMODATION HOUSE WATERTIGHT DOORS PROVING WATERTIGHTNESS.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Documentation
Issued 16 July 1995 Resolved
PROVIDE PROOF OF REISSUE TO NEW OWNER/OPERATOR THE CERTIFICATE OF FINANCIALRESPONSIBILITY.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Documentation
Issued 16 July 1995 Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING ALL THE EMERGENCY EQUIPMENT REQ'D BY THE VESSEL'S SHIPBOARD OIL POLLUTION EMERGENCY PLAN (MARPOL REG 26) IS ONBOARD.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Deck/Cargo
Issued 16 July 1995 Resolved
PROVIDE CLASS REPORT ON RECOMMENDATION FOR #4 CARGO HATCH EXTERNAL HYDRAULIC LIFTING CYLINDER AND BRACKET DAMAGE.
Condition: Unknown
Due 23 July 1995
Resolved 23 July 1995
Engineering
Issued 2 May 1990 Resolved
FLAME SCREENS FOR THE FUEL OIL AND LUBE OIL TANK VENTS WERE WORN AND _x001C_ NEEDED REPLACING.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Accommodation/Occupational Safety
Issued 2 May 1990 Resolved
VESSELS MSD TYPE II DID NOT HAVE CHLORINE TABLETS FOR THEIR OPERATIN_x001C_ MSD.
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Navigation
Issued 15 March 1988 Resolved
33CFR164.35(K) NO BLOCK DIAGRAM FOR STEERING GEAR POSTED ON BRIDGE.
Condition: Unknown
Due 15 March 1988
Resolved 15 March 1988
Documentation
Issued 15 March 1988 Resolved
33CFR151.25(D)(3) DISPOSAL OF OIL RESIDUES (SLUDGE) NOT ENTERED IN VESSEL'SOIL RECORD BOOK.
Condition: Unknown
Due 15 March 1988
Resolved 15 March 1988
Documentation
Issued 15 March 1988 Resolved
33CFR155.750(A) VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Condition: Unknown
Due 15 March 1988
Resolved 15 March 1988
Documentation
Issued 9 May 1986 Resolved
NO POLLUTION PLACARD ONBOARD AS REQUIRED BY 33CFR155.40
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986
Lifesaving
Issued 9 May 1986 Resolved
ANNUAL LIFERAFT SERVICING CERTIFICATES EXPIRED 21MAR86
Condition: Unknown
Due 9 May 1986
Resolved 9 May 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.