← All vessels
CAPTA SPYROS
CAPTA SPYROS is a 1972 freight ship. The Coast Guard has recorded 13 inspections since 1984, most recently in July 1995, along with 30 deficiencies and 1 operational control.
Records from 1984 to 1995. Most recent: operational control imposed, 17 July 1995.
- Built
- 1972
- Last inspected
- 16 July 1995
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7203376 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EKM5
222660
Flag
GREECE
—
Maury page id
psix-222660
Inspections, by type
…with no type recorded13
Years with a record
8 calendar years (1984–1995)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it13120 - Convention (Subpart B), Gross Ton
23236 - Dead Weight, Ton
23236 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
16 July 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 380654
15 February 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 182524
2 December 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347390
2 May 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 336738
3 April 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 329049
20 March 1989
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 329185
14 September 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 458988
15 March 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 321998
11 September 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 520782
22 January 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 313926
19 May 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 308950
9 May 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 308732
8 November 1984
Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 298769
Deficiency record · 30
Fire Fighting
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING FIRE FIGHTING SPRAY NOZZLES HAVE BEEN PROVIDED AT EACH FIRE HOSE STATION IN THE MACHINERY SPACES.
Engineering
Issued 16 July 1995
Resolved
PRIOR TO CONDUCTING BUNKERING OPERATIONS IN U.S. WATERS PROVIDE DOCUMENTATION TO THE COGNIZANT [name withheld] OF THE TEST REQUIREDBY 33 CFR 156.170 ON THE BUNKER PIPING SYSTEM (1 1/2 TIMES MAWP).
Engineering
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT OF PROPER OPERATION OF THE OILY WATER SEPARATOR.
Lifesaving
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT THAT THE GLASS COVER FOR THE #2 EMERGENCY STOPSWITCH LOCATED IN THE PORT MAIN ACCOMMODATION HOUSE PASSAGEWAY HAS BEEN INSTALLED.
Engineering
Issued 16 July 1995
Resolved
PRIOR TO CONDUCTING BUNKER OPERATIONS IN U.S. WATERS DEMONSTRATE TO A COASTGUARD REPRESENTATIVE THE BUNKER TRANSFER PROCEDURES MEET 33 CFR 155.750 OR PROVIDE A COPY TO THE COGNIZANT OCMI.
Accommodation/Occupational Safety
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT FOR REPAIR TO WASTED STEPS IN WAY OF THE LADDER BETWEEN THE 01 AND 02 DECK LOCATED ON THE AFT END OF THE ACCOMMODATION HOUSE.
Construction/Loadline
Issued 16 July 1995
Resolved
PROVIDE CLASS REPORT FOR INSTALLATION OF MISSING BOW COMPARTMENT HATCH COVER SECURING DEVICES.
Lifesaving
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT FOR WITNESS OF LIFEBOAT BEING OPERATED IN THE WATER WITHIN THE PAST 3 MONTHS.
Construction/Loadline
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT FOR REPAIRS TO STBD, AFT, MAIN DECK C02 COMPARTMENT WATERTIGHT DOOR CLOSURE/TIGHTNESS.
Fire Fighting
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT WITNESSING OPERATION OF ADEQUATE EMERGENCY FIRE PUMP WATER STREAM.
Fire Fighting
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT FOR ALL ITEMS NEEDED FOR THE INTERNATIONAL SHORE CONNECTIONS HAVE BEEN PROVIDED (GASKET & 4 BOLTS, WASHERS & NUTS).
Fire Fighting
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT WITNESSING FIRE STATION #6 HAS ALL REQ'D EQUIPMENT (MISSING NOZZLE & SPANNER WRENCH).
Lifesaving
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING LIFERING BUOY WATERLIGHT STBD SIDE MAIN DECK IS OPERATIONAL.
Fire Fighting
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT FOR UPDATING ALL FIRE PLANS WITH CURRENT VESSEL NAME.
Lifesaving
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT THAT TWO COMPLETE FIRE SUITS HAVE BEEN PROVIDED.
Lifesaving
Issued 16 July 1995
Resolved
PROVIDE CLASS REPORT INDICATING TWO COMPLETE SELF-CONTAINED BREATHING APPARATUS (SCBA) HAVE BEEN PROVIDED.
Lifesaving
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING TWO ELECTRIC LANTERNS HAVE BEEN PROVIDED FOR THE FIREMAN OUTFITS.
Lifesaving
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT WITNESS PROPER OPERATION OF STBD LIFEBOAT ENGINE (STALLS IN NEUTRAL).
Fire Fighting
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT OF SERVICE TECHNICIAN EXAMINING AND SERVICING THE CARGO HOLD CO2 FIXED CYLINDERS IN WAY OF TWO WITH TWISTED FLEX LOOPS AND ONE WITH THE FLEX LOOP BROKEN OFF.
Construction/Loadline
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT FOR REPAIRS TO THE MAIN DECK ACCOMMODATION HOUSE WATERTIGHT DOORS PROVING WATERTIGHTNESS.
Documentation
Issued 16 July 1995
Resolved
PROVIDE PROOF OF REISSUE TO NEW OWNER/OPERATOR THE CERTIFICATE OF FINANCIALRESPONSIBILITY.
Documentation
Issued 16 July 1995
Resolved
PROVIDE CLASS SOCIETY REPORT INDICATING ALL THE EMERGENCY EQUIPMENT REQ'D BY THE VESSEL'S SHIPBOARD OIL POLLUTION EMERGENCY PLAN (MARPOL REG 26) IS ONBOARD.
Deck/Cargo
Issued 16 July 1995
Resolved
PROVIDE CLASS REPORT ON RECOMMENDATION FOR #4 CARGO HATCH EXTERNAL HYDRAULIC LIFTING CYLINDER AND BRACKET DAMAGE.
Engineering
Issued 2 May 1990
Resolved
FLAME SCREENS FOR THE FUEL OIL AND LUBE OIL TANK VENTS WERE WORN AND _x001C_ NEEDED REPLACING.
Accommodation/Occupational Safety
Issued 2 May 1990
Resolved
VESSELS MSD TYPE II DID NOT HAVE CHLORINE TABLETS FOR THEIR OPERATIN_x001C_ MSD.
Navigation
Issued 15 March 1988
Resolved
33CFR164.35(K) NO BLOCK DIAGRAM FOR STEERING GEAR POSTED ON BRIDGE.
Documentation
Issued 15 March 1988
Resolved
33CFR151.25(D)(3) DISPOSAL OF OIL RESIDUES (SLUDGE) NOT ENTERED IN VESSEL'SOIL RECORD BOOK.
Documentation
Issued 15 March 1988
Resolved
33CFR155.750(A) VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Documentation
Issued 9 May 1986
Resolved
NO POLLUTION PLACARD ONBOARD AS REQUIRED BY 33CFR155.40
Lifesaving
Issued 9 May 1986
Resolved
ANNUAL LIFERAFT SERVICING CERTIFICATES EXPIRED 21MAR86
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National