MAURY USCG vessel records Sign in
← All vessels

BEAUREGARD

BEAUREGARD is a 2001 offshore supply vessel. The Coast Guard has recorded 40 inspections since 2001, most recently in May 2026, along with 46 deficiencies, 1 operational control and 2 casualty investigations between 2007 and 2009.

Records from 2001 to 2026. Most recent: inspection, 13 May 2026.

Built
2001
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8967498 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDA5093
Flag
UNITED STATES
366816410
Maury page id
psix-22270

Inspections, by type

…with no type recorded5
Years with a record 22 calendar years (2001–2026)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)121.6 ft × 32.0 ft × 12.5 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)121.6 ft × 32.0 ft × 12.5 ft
ITC tonnagegross 389 / net 116
BuilderLA FORCE SHIPYARD INC · BAYOU LA BATRE, AL, UNITED STATES · built 2001
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 January 2026 · expires 28 February 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
389 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
116 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDA5093MMSI 366816410 · active · compulsorily equipped · granted 30 April 2021, expires 22 June 2031
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 40

13 May 2026 MTSA Verification · Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8320055
6 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8291012
12 March 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8092091
26 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7885393
18 March 2024 Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7881059
13 March 2024 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7879019
17 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7690811
10 May 2023 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7686243
9 April 2022 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7427607
27 May 2021 Drydock Exam · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7208398
28 May 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6963062
4 June 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6703001
31 May 2019 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6699074
8 August 2018 Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6504630
12 July 2018 MTSA/ISPS Verification · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6441383
21 February 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6358845
22 August 2017 Type not recorded
No type recorded · Station Lake Charles · USCG Heartland District (CGD-H) · Activity 6248620
9 May 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6142239
13 April 2017 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6119220
9 June 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5902656
8 May 2014 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4852819
2 May 2014 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4848370
16 May 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4313280
9 May 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4306559
16 April 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3453579
12 April 2009 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3451589
9 June 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3231676
25 September 2007 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3065498
24 September 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3081624
18 April 2007 Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2909940
25 July 2006 Re-Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2724017
16 August 2005 Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2464855
29 July 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2444298
17 May 2005 Internal Structural Exam · MTSA Verification · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2353913
21 April 2005 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2339849
5 May 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2059868
1 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1784401
9 May 2002 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1616262
27 June 2001 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1067764
26 April 2001 Hull Examination · Initial Construction-Excluding Oversight · Initial Certification · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1462216

Deficiency record · 46

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 March 2024 Resolved
Steering gear must be capable of moving the rudder from 35 degrees to 30 degrees in 28 seconds; rudder could not go beyond 30 degrees stbd. 46 CFR 130.130(c)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2025
Resolved 18 March 2024
Resolution: RAI calibrated
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 May 2023 Resolved
Vessel shall ensure that the vessel is in satisfactory condition and is fit for the service for which it is intended. Vessel had Port Gen Air Starter blow diesel onto the engine and had the fuel soaked rag under the RACOR. Vessel also had not desposed of the prior nights fuel filter change was in a bucket near the air compressors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 May 2023
Resolution: SSG(s) starting system was overhauled and witnessed to be in satisfactory condition. All oily rags and filters were removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 May 2023 Resolved
Vessel shall maintain watertight integrity. The Port & STBD Engine Room Hatches required adjustment as air was felt roming through in multiple places. STBD Escape Hatch would not dog. Galley WTD was adjusterd and Corrected during the inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2023
Resolution: ABS observed WTD correction and signed ILLC. Using signed ILLC as objective evidence to clear def.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 10 May 2023 Resolved
Fire Drills shall be held on alternating weeks. Vessel went 6 weeks w/o a fire drill.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2023
Resolution: Notified Vessel Rep, Master, & Mate on requirement. Vessel had done a fire drill just prior to the inspection.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 10 May 2023 Resolved
Abandon Ship drills must be held on each vessel in alternating weeks. Last abandon ship drill prior to insepction was on 27MAR2023.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2023
Resolution: Conducted Abandon Ship drill during inspection allowing the vessel to come into complaince.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 April 2022 Resolved
A fuel leak was found on the port generator and a lube oil leak was found on the starboard generator. Vessel is required to rectify the leak before operation.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2022
Resolved 12 April 2022
Resolution: Engines and generators were operated with no leaks observable leak.
11 - Life Saving Appliances › N/A - No Subsystem › Embarkation arrangement survival craft
Issued 9 April 2022 Resolved
Each embarkation station must be adequately lighted. No lighting was present at the survival craft embarkation station. Vessel is required to install lighting for the embarkation station.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 11 April 2022
Resolved 12 April 2022
Resolution: Embarkation lighting was installed and verified to operate on Emergency Power.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 April 2022 Resolved
Doubler plate on port aft of the vessel, approximately 6 feet above the water line has an 8 inch crack. The doubler plate acts to protect the frame of the vessel. Crack must be non-destructively tested to confirm it is only in the doubler plate and not in the frame of the vessel.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2022
Resolved 12 April 2022
Resolution: Weld was completed on the doubler plate that was cracked. This satifies the requirement.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 April 2022 Resolved
Navigation light indicator panel must have an audible and visual alarm if there is a failure of the navigation lights. Vessels panel did not audibly alarm. Alarm must be audible.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2022
Resolved 12 April 2022
Resolution: Navigation lighting panel audible and visual alarm was operable.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 27 May 2021 Resolved
All access openings in bulkheads at ends of enclosed superstructures shal be fitted with doors of steel or other equivalent material, permanently and strongly attached to the bulkhead, and rframed, and stiffened and fitted so that the whole structure is of equivalent strength to the unpiereced bulkhead and weathertight when closed; 02 watertight doors and the starboard side escape hatch scuttle leading to the main deck were unable to be secured to create a watertight seal.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 June 2021
Resolution: Watertight doors were adjusted to create a watertight seal prior to completing the inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2021 Resolved
The rules concerning lights shall be complied with from sunset to sunrise; masthead light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 June 2021
Resolution: New bulb for masthead light was installed prior to the completion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 May 2021 Resolved
Lifesaving appliances and arrangements are subject to tests and amd inspections as described i this section during OSV boardings to ensure that the appliances and arrangements comply with applicable requirements, are in satisfactory condition, and remain fit for service; retro-reflective tape on lifefloats were sun-damaged.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 3 June 2021
Resolution: New retro-reflective tape was applied to the lifefloats prior to the completion of the inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Tonnage certificate
Issued 27 May 2021 Resolved
A certificate of measurement issued by an authorized official is the only acceptable evidence of the gross and net tonnage of a vessel measured in accordance with subaprt B, C, or D of 46 CFR Part 69; vessel's tonnage certificate was not present on the vessel at the time of inspection and not present in ship's files.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2021
Resolved 18 June 2021
Resolution: Company emailed attending MI a copy of the company's request to the CG to have a new copy of the vessel's tonngae certificate mailed out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2020 Resolved
ALL INSTALLATIONS SHALL BE OF MARINE TYPE ENGINES SUITABLE FOR INTENDED SERVICE; VSL HAD AN EXHAUST LEAK ON THE PORT ENGINE; VSL REPLACED SEAL TO MAKE "GASTIGHT" PRIOR TO INSPECTION COMPLETION.
Action required: 10 - Deficiency Rectified
Due 29 May 2020
Resolved 29 May 2020
Resolution: Replaced seal
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 May 2020 Resolved
EACH GENERATOR MUST HAVE AN OVERSPEED DEVICE THAT IS INDEPENDENT OF NORMAL OPERATING GOVENOR; VSL'S PORT GENERATOR WAS INOPERABLE; PROVIDE TECH REPORT VERIFYING PROPER OPERATION.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 May 2020
Resolved 1 October 2020
Resolution: Verified port generator operational and overspeed tested.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 May 2020 Resolved
SELF-IGNIGTING LIGHTS MUST BE ATTACHED TO LIFEBUOYS WITH A BUOYANT LIFELINE; THE LIFELINE WAS WASTED AND NOT SERVICABLE; VSL REPLACED LINE PROIR TO INSPECTION COMPLETION.
Action required: 10 - Deficiency Rectified
Due 29 May 2020
Resolved 29 May 2020
Resolution: Line was replaced prior to inspection completion.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 May 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Due 29 May 2020
Resolved 29 May 2020
Resolution: Replaced batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 May 2020 Resolved
EACH LIFEBOAT AND RESCUE BOAT MUST BE MARKED WITH TYPE II RETRO-REFLECTIVE MATERIAL; THE THREE LIFE FLOATS DID NOT HAVE APPROVED RETRO TAPE; VSL REPLACED TAPE WITH APPROVED MATERIAL PRIOR TO COMPLETION OF INSPECTION. 46CFR131.855(d)
Action required: 10 - Deficiency Rectified
Due 29 May 2020
Resolved 29 May 2020
Resolution: Replaced retro-reflective tape
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2019 Resolved
Navigation Light screens were painted green and not matt black. Paint navigation light screens matt black. 33 CFR 84.05
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 June 2019
Resolved 4 June 2019
Resolution: Navigation Light screens painted matt black.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 July 2018 Resolved
Vessel crew could not prove proper operation of ship service generators. Prove proper operation.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 8 August 2018
Resolution: Obtained objective evidence that a third party completed test of overspeed shutdowns.
Lifesaving › Lifeboat Equipment › Life Saving Signals Card
Issued 13 April 2017 Resolved
Vessel did not have lifesaving signal and helicpoter recovery placard
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 9 May 2017
Resolution: Placard is now posted
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 13 April 2017 Resolved
Vessel had log book but preunderway checks were not being logged.
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 9 May 2017
Resolution: Appropriate entries are now being made
Lifesaving › Line-Throwing Appliances › Lines
Issued 13 April 2017 Resolved
Vessel captain and crew could not find auxliary line. The line had to be pointed out by port captain
Due 13 April 2017
Resolved 13 April 2017
Resolution: Port Captain provided location of sufficient aux line.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 13 April 2017 Resolved
Vessel is equiped with more than one type and size of extinguisher. None were marked with stowage location number.
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 14 April 2017
Resolution: Stowage locations were clearly marked and all portable extiguishers were of type and stowed in locations as defined on vessels fire and safety plan.
Engineering › Diesel Engine (propulsion-electric) › Emergency shutdown
Issued 13 April 2017 Resolved
emergency shutdown and overspeed not operational. SSDG also did not run smooth and hunted.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2017
Resolved 14 April 2017
Resolution: Emergency shutdow poperly operated when actuated.
Engineering › Fuel Oil Service System › Valve, Solenoid
Issued 13 April 2017 Resolved
Excessive fuel leak on bow thruster fuel pressure sensor.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 April 2017
Resolved 14 April 2017
Resolution: Fuel Presure sensor was replace. No leaks detected.
Communications › Public Address System › Loudspeaker
Issued 13 April 2017 Resolved
Vessels two way communication system was not operable on E power.
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 14 April 2017
Resolution: Two way comms system operated correctly on E power.
Communications › Alarms/Indicators › General Alarm
Issued 10 May 2012 Resolved
Visual indicator for General Alarm in the engine room was not operating.
Condition: Improper/Lack of Maintenance
Due 17 May 2012
Resolved 11 May 2012
Resolution: Received email from vsl rep, item corrected.
Construction/Loadline › Structures › Scuttle
Issued 10 May 2012 Resolved
Port and STBD escape hatches were both out of adjustment. Port hatch would not close.
Condition: Improper/Lack of Maintenance
Due 14 May 2012
Resolved 11 May 2012
Resolution: Received email from vsl rep, items corrected.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 10 May 2012 Resolved
Tested stbd ssdg overspeed. Genset did not shut-down.
Condition: Improper/Lack of Maintenance
Due 17 May 2012
Resolved 11 May 2012
Resolution: Received email from vsl rep, bad solenoid, item corrected.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 10 May 2012 Resolved
Vsl had not been logging monthly abandon ship drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2013
Resolution: Drills were logged and current.
Operations/Management › Drills/Instruction › Fire
Issued 10 May 2012 Resolved
Vsl had not been logging monthly fire drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2013
Resolution: Drills were logged and current.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 10 May 2012 Resolved
Vsl had not been logging monthly man overboard drills.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2013
Resolution: Drills were logged and current.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2012 Resolved
Vsl was missing for the fire pump coupling.
Condition: Improper/Lack of Maintenance
Due 17 May 2012
Resolved 11 May 2012
Resolution: Received email from vsl rep, item corrected.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 10 May 2012 Resolved
Found wrong battery in float-light. Battery was spring type and vsl needs screw post.
Condition: Improper/Lack of Maintenance
Due 10 May 2012
Resolved 10 May 2012
Resolution: Vsl installed the correct battery in float-light.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 May 2012 Resolved
Vessel's COI was 22 days past expiration date at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 May 2012
Communications › Radio Communications › EPIRB
Issued 9 May 2012 Resolved
Vsl had not been logging monthly EPIRB tests.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 April 2013
Resolution: EPIRB tests were logged and current.
Construction/Loadline › Hull › Hull Plating
Issued 25 September 2007 Resolved
Vessel allowed to proceed to Galliano for repairs to stbd bow hull plate and affected internals. Two each swash bulkheads tripped/buckled, hull plate hulled approx. 4' x 5'. Repairs to be made to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2007
Resolved 3 October 2007
Resolution: Damage repairs made under the oversight of attending ABS surveyor, and to the satisfaction of the attending Marine Inspector. See attached ABS repair survey report.
Engineering › Diesel Engine (propulsion-reduction gear) › Turbocharger
Issued 18 April 2007 Resolved
Supply service ticket from service tech for port MDE turbo replacement and adjustment of genset overspeen trips.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2007
Resolution: corrected same day
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 25 July 2006 Resolved
Renew weak links in lifefloats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2006
Engineering › Compressed Air System (start air) › Valve
Issued 25 July 2006 Resolved
Renew pressure relief valve on port side air receiver.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2006
Lifesaving › Rescue Boat › Boarding Ladder
Issued 25 July 2006 Resolved
Add winch to rescue platform so it is operable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 July 2006
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 25 July 2006 Resolved
Provide updated charts of LNTM
Due 25 August 2006
Resolved 28 July 2006
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 25 July 2006 Resolved
Post Fuel oil transfer procedures near pump/manifold
Action required: 705 - Other - as specified
Due 25 August 2006
Resolved 28 July 2006
Documentation › Certificates/Documents › Stability Letter
Issued 10 May 2005 Resolved
Provide corrected stability letter to match load line certificates by 17Jun2005. Vessel is authorized to operate pending correction of load line and stability. Vsl is to adhere to current certificates.
Action required: 705 - Other - as specified
Due 25 June 2005
Resolved 16 August 2005
Resolution: Provided correct stability letter.
Documentation
Issued 26 April 2001 Resolved
Re-submit Electrical drawings to MSC after corrections have been made.
Condition: Unknown
Due 10 July 2001
Resolved 27 June 2001

Casualty record · 2

24 September 2007Routine · role: Involved in a Marine Casualty · activity 3081624
12 April 2009Routine · role: Involved in a Marine Casualty · activity 3451589
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.