Records from 1985 to 2000. Most recent: inspection, 24 March 2000.
Inspection history · 58
24 March 2000
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1048224
13 March 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1401198
18 December 1999
MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1365515
22 November 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 810312
27 March 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 427042
10 March 1999
Quarterly Examination · Deficiency Check · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372535
9 March 1999
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 801133
17 February 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 794552
18 December 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 492193
18 December 1998
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1418449
7 April 1998
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1123358
31 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753952
27 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 192015
27 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 414421
25 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 18803
17 March 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 413875
17 March 1998
Quarterly Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 775437
20 February 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1427464
16 December 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 410998
16 December 1997
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 784037
16 December 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1448991
12 March 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 401677
12 March 1997
Quarterly Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1377975
30 January 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 400023
29 January 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 528584
24 January 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 399842
18 December 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 398576
18 December 1996
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1418068
21 November 1996
Type not recorded
No type recorded · Activities Europe · Activity 1356008
14 March 1996
Quarterly Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1077551
22 December 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1186458
19 December 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 385912
19 December 1995
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1383116
7 April 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1154291
24 March 1995
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 376645
24 March 1995
Quarterly Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1141091
23 December 1994
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158082
25 March 1994
Quarterly Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1391973
20 December 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1162020
29 March 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1140506
12 February 1993
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 835849
17 December 1992
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 355662
17 December 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1473005
12 April 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955379
21 December 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347980
21 December 1991
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 941177
7 April 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 917625
19 December 1989
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1235601
22 December 1988
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1210749
19 December 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1004782
13 August 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1340868
5 May 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1326197
18 December 1986
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310797
25 June 1986
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 309799
4 March 1986
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1292530
17 December 1985
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1300826
17 January 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 300049
17 January 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 300233
Construction/Loadline
Issued 24 March 2000
Resolved
Address and provide documentation concerning indentation/hull and frame inset located starboard side near frame #22. Provide report to U.S. Coast Guard by 13APR2000.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Construction/Loadline
Issued 13 March 2000
Resolved
HAVE CLASS ADDRESS AND PROVIDE DOCUMENTATION CONCERNING HULL INDENTATION AND FRAME INSERT LOCATED STARBOARD SIDE NEAR FRAME #22 AND PROVIDE REPORT TO U.S. COAST GUARD MIAMI, FL.
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Unknown
Issued 27 March 1999
Resolved
Have safety officer conduct meeting with crew to discuss and resolve concerns with safety issues as outlined in vessels Safety Management Certificate.
Condition: Unknown
Due 27 April 1999
Resolved 29 April 1999
Fire Fighting
Issued 18 December 1998
Resolved
PROVIDE DOCUMENTATION FROM THE ADMINISTRATIONPROVING THAT THE VENEERS ON THE OVERHEAD PANELS AND PAINT ON THE WOOD FRAMING SUPPORTING THE OVERHEAD PANELS MEET THE REQUIREMENTS OF SOLAS 60 REG 49(e) AND REG 35(m) FOR A METHOD II VESSEL IN CABIN OVERHEADS.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Documentation
Issued 18 December 1998
Resolved
PROVIDE ENTRY IN SHIPS LOG BOOK RECORDING THE OFFICIAL WORKING LANGUAGE OF THE CREW.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Lifesaving
Issued 18 December 1998
Resolved
REMOVE ALL COMBUSTIBLES (PAINTS, THINNERS, SOLVENTS STOWED IN ENGINE ROOM PARTS LOCKER OR RELOCATE ITEMS TO PAINT LOCKER.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Lifesaving
Issued 18 December 1998
Resolved
PROVIDE EVIDENCE FROM THE FLAG ADMINISTRATION OR CLASS SOCIETY IN REFERENCETO LIFEBOAT FALLS INSTALLATION DATE.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Documentation
Issued 18 December 1998
Resolved
PROVIDE EVIDENCE THAT VSL IS PROVIDED AN OPERATIONAL LIMITATIONS MANUAL OR EQUIVELANT.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Lifesaving
Issued 18 December 1998
Resolved
PROVIDE FLAG APPROVAL ATTESTING TO THE CONDITION OF LIFERAFT STATION #2 WIRE FALLS AND RESPLICING OF LIFERAFT WIRE CABLE EYE END.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Fire Fighting
Issued 18 December 1998
Resolved
ENLARGE LOBBY ENTERING AUXILIARY MACHINERY SPACE TO 9.0 SQ METERS. INSTALLSMOKE DETECTOR, SPRINKLER, AND FIRE HOSE STATION. REQUIREMENT WAS ISSUE VIA PH CALL WITH [name withheld] THE V.P. OF THE TECH DEPT. DRAWINGSOF LOBBY ARE ONE FILE AT MSO SAN JUAN AND G-MSC.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Fire Fighting
Issued 18 December 1998
Resolved
FIRE STATION NEAR FSD 117A NEEDS TO BE MODIFIED IN ORDER TO MAINTAIN HOSE CONNECTION TO HYDRANT AT ALL TIMES.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Fire Fighting
Issued 18 December 1998
Resolved
PROVIDE A-60 INSULATION IN THE OVERHEAD IN THE MAIN LAUNDRY ON THE PORT ANDSTBD AFT ENDS ADJACENT TO THE SIDE SHELL AND IN AREAS ABOVE THE VENTILATIONDUCTING.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Fire Fighting
Issued 18 December 1998
Resolved
PROVIDE A-60 INSULATION IN THE PORT AND STBD STOREROOM OVERHEADS AT THE MAIN DECK FRAME 33.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Engineering
Issued 18 December 1998
Resolved
PROVIDE COMPLETE OIL TRANSFER PROCEDURES IAW 33 CFR 157.750. ITEMS MISSING WERE DIAGRAMATIC DRAWING OF TRANSGER SYSTEM, PRODUCTS TRANSFERED LISTING, AND OUTLINED RESPONSIBILITIES OF EACH INDIVIDUAL INVOLVED IN THE TRANSFER OPERATION.
Condition: Unknown
Due 18 December 1998
Resolved 18 December 1998
Construction/Loadline
Issued 7 April 1998
Resolved
Complete required repairs to Number 10 (B) Fuel Oil Deep Tank and provide Class Society attestment of permanent and proper repairs.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Construction/Loadline
Issued 7 April 1998
Resolved
Provide for adherence to outstanding Condition of Class imposed 01APR98 (Provisional) in regards to Number 10 (B) Fuel Oil Deep Tank.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Construction/Loadline
Issued 27 March 1998
Resolved
PRIOR TO RETURNING TO U.S. WATERS, PROVIDE CLASS REPORT ATTESTING TO CONDITION OF #10B STBD FUEL OIL TANK. CONTINUE TO MONITOR FOR ADDITIONAL LEAKS AND REPORT ANY SUCH LEAKS TO THE [name withheld].
Condition: Unknown
Due 10 April 1998
Resolved 8 April 1998
Fire Fighting
Issued 20 February 1998
Resolved
PROVIDE INSULATION ON OVERHEAD AND FWD BULKHEAD IN STOREROOM AT MAIN DECK AT FRAME 35. PROVIDE PROOF THAT CINEMA FLOOR (ABOVE STOREROOM) HAS SFP INSULATION INSTEAD OF INSULATING STOREROOM OVERHEAD.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 20 February 1998
Resolved
PROVIDE FIRE STATION IN LOBBY LOCATED OUTSIDE OF WTD (FRAME 125) TO AUX. MACHINERY SPACE ON HOLD & STORES DECK.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 20 February 1998
Resolved
MODIFY ALL SLIDING FIRE DOORS TO ALLOW THEM TO BE OPENED BY PASSENGERS.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 20 February 1998
Resolved
PROVIDE DOCUMENTATION THAT SURFACES ON OVERHEADS OF PASSENGER CABINS ARE OFLOW FLAME SPREAD CHARACTERISTICS.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 20 February 1998
Resolved
PROVIDE AUTOMATIC SPRINKLERS IN ALL REFRIGERATED STOREROOMS.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 20 February 1998
Resolved
PROVIDE LOW FLAME SPREAD CHARACTERISTICS ON ALL CONCEALED SURFACES BEHIND BULKHEADS IN THE DISCOTHEQUE.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 20 February 1998
Resolved
REMOVE AND RELOCATE THE ACCESS DOOR AT THE VERTICAL LOBBY BETWEEN THE MACHINERY SPACE AND THE EMERALD DECK (I.A.W. MSC LTR H2-9703957).
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 20 February 1998
Resolved
PROVIDE SFP INSULATION,(A-60) ON OVERHEAD IN MAIN LAUNDRY, TO SEPERATE FROMTHE ACCOMMODATION SPACES ABOVE.
Condition: Unknown
Due 20 February 1998
Resolved 20 February 1998
Fire Fighting
Issued 16 December 1997
Resolved
CLEAN OR REPLACE SPRINKLER HEAD UNIT IN THE LAUNDRY.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 16 December 1997
Resolved
REMOVE GREASE FROM LAUNDRY FIRE SCREEN DOOR NAME PLATE.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 16 December 1997
Resolved
REPLACE TWO FIRE EXTINGUISHERS; ONE LOCATED IN THE AFT SHAFT ALLEY AND ONE USED FOR THE FIRE DRILL (BOTH EXTINGUISHERS MISSING SEALS.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Engineering
Issued 16 December 1997
Resolved
tighten or replace packing gland for port side main engine sea suction.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Fire Fighting
Issued 16 December 1997
Resolved
TIGHTEN OR REPLACE PACKING GLAND FOR STARBOARD SIDE FIRE PUMP.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Electrical
Issued 16 December 1997
Resolved
PROVIDE PROPER ENCLOSURE FOR OVERHEAD ELECTRICAL CONNECTION IN #3 LIFEBOAT.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Accommodation/Occupational Safety
Issued 16 December 1997
Resolved
REMOVE CLOTHE LINE FROM THE SPRINKLER PIPES IN THE LAUNDRY ROOM.
Condition: Unknown
Due 17 December 1997
Resolved 18 December 1997
Documentation
Issued 16 December 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Lifesaving
Issued 16 December 1997
Resolved
PROVIDE DOCUMENTATION OF CLASS SOCIETY ACCEPTANCE OF FIBERGLASS REPAIR TO #4 LIFEBOAT HULL.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Accommodation/Occupational Safety
Issued 16 December 1997
Resolved
INSTALL HOLDBACK DEVICE OR ADJUST DECORATIVE SWINGING GLASS DOOR LEADING FROM EMBARKATION DECK TO STAIRWAYS.
Condition: Unknown
Due 23 February 1998
Resolved 23 February 1998
Navigation
Issued 18 December 1996
Resolved
PROVIDE GUARD COVER FOR PORT AND STBD STEERING GEAR PUMP PULLEYS.
Condition: Unknown
Due 26 January 1997
Resolved 27 January 1997
Navigation
Issued 18 December 1996
Resolved
SECURE ALL LOOSE GEAR IN STEERING ROOM
Condition: Unknown
Due 26 January 1997
Resolved 27 January 1997
Engineering
Issued 18 December 1996
Resolved
PROVIDE A COMPLETE OIL TRANSFER PROCEDURE PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 26 January 1997
Resolved 27 January 1997
Navigation
Issued 18 December 1996
Resolved
REPAIR WATER LEAKAGE ON PORT STERN TUBE RUDDER POST BY VOID SPACE AND FEED WATER SERVICE TANK COFFERDAM #913. REPAIR TO THE SATISFACTION OF CLASS AND PROVIDE MSO A COPY OF CLASS REPORT.
Condition: Unknown
Due 18 January 1997
Resolved 26 December 1996
Lifesaving
Issued 18 December 1996
Resolved
INSTALL BOTTLE BRACKETS FOR FREON BOTTLES IN STEERING ROOM.
Condition: Unknown
Due 26 January 1997
Resolved 27 January 1997
Navigation
Issued 19 December 1995
Resolved
PROVE PROPER OPERATION OF MAGNETIC COMPASS
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSTALL STOPS TO ENSURE GLASS DOORS DO NOT BLOCK FSD #24
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
LABEL FIRESTATION #28 ON OUTSIDE OF LOCKER DOOR
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Lifesaving
Issued 19 December 1995
Resolved
CONDUCT BOAT DRILL IN PRESENTS OF CG MARINE INSPECTOR.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Lifesaving
Issued 19 December 1995
Resolved
PROPERLLY INSTALL RETRO MATERIAL ON ALL CHILDERNES LIFEJACKETS
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #26
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #20
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #21
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #43
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #72
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF SFD # 46
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #61
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #19
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
ISURE PROPER OPERATION OF FSD #13
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD # 25
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Lifesaving
Issued 19 December 1995
Resolved
PROVIDE PROPER LIGHTS FOR ALL LIFEJACKETS
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURTE PROPER OPERATION OF FSD #77
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #99
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #85
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #96
Condition: Unknown
Due 22 December 1995
Resolved 22 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSURE PROPER OPERATION OF FSD #71
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Construction/Loadline
Issued 19 December 1995
Resolved
RENEW GASKET ON STBD BUNKER STATION SIDEPORT
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Accommodation/Occupational Safety
Issued 19 December 1995
Resolved
REMOVE BUILD UP OF LINT FROM LAUNDRY EXHAUST VENTS
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 19 December 1995
Resolved
INSTALL STOPS TO ENSURE GLASS DOORS DO NOT BLOCK FSD #27
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 24 March 1995
Resolved
PROVE STRUCTURAL INTEGRITY OF MAIN FIRE PUMP DISCHARGE VALVE IN ENGINEROOM AND PIPING (ELBOW) JUST AFTER GLOBE VALVE AT NEXT ANNUAL COC. VALVE BODY AND BOTTOM OF ELBOW ARE FIBERGLASSED (PATCHED). ENGINEERS CONTEND THIS IS NOT DAMAGE/CORROSION BUT CONDENSATION/CORROSION PREVENTION.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Documentation
Issued 20 December 1993
Resolved
C.1 SUBDIVISION LOADLINE TO BE MARKED ON SHIP'S SIDES.
Condition: Unknown
Due 20 December 1993
Resolved 20 December 1993
Documentation
Issued 20 December 1993
Resolved
ALL CREWMEMBERS TO HAVE UPDATED MEDICAL CERTIFICATES AS PER I.L.O. 147
Condition: Unknown
Due 20 December 1993
Resolved 20 December 1993
Lifesaving
Issued 20 December 1993
Resolved
PROVIDE DOCUMENTATION THAT FLOAT FREE LIFERAFTS HAVE THE REQUIRED PAINTER'S"WEAK LINK" STORED INSIDE CANISTER.
Condition: Unknown
Due 20 December 1993
Resolved 20 December 1993
Navigation
Issued 17 December 1992
Resolved
Provided an updated List of Lights for vessel's operating area.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Lifesaving
Issued 17 December 1992
Resolved
Replace all crew lifejackets showing signs of deterioration.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Lifesaving
Issued 17 December 1992
Resolved
Provide a total of twelve (12) parachute flares.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Documentation
Issued 17 December 1992
Resolved
Ensure log book entries are made whenever side shell doors are opened_x001C_ below the margin the line.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Construction/Loadline
Issued 17 December 1992
Resolved
Repair watertight doors 9, 10, and 15. Doors slowly creep open after_x001C_ they have been closed locally by power.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Construction/Loadline
Issued 17 December 1992
Resolved
Access door to manual watertight door pump can not be opened when_x001C_ watertight door no. 9 is closed. Remove or reconstruct access door.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Fire Fighting
Issued 17 December 1992
Resolved
Repair fire screen doors 35 and 53, doors will not fully close.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Construction/Loadline
Issued 17 December 1992
Resolved
Remove excess paint from port light covers in the crew's galley and _x001C_ prove proper operation of covers.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Documentation
Issued 21 December 1991
Resolved
The vessels oil transfer procedures were incomplete in that the procedures for emptying the manifold containment, procedures for operating communications, procedures for topping off tanks and procedures for reporting discharges were missing.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Engineering
Issued 21 December 1991
Resolved
The vessel failed to have "discharge of oil prohibitted" placards in the pumproom and at bunker stations.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992