MAURY USCG vessel records Sign in
← All vessels

SEA HARMONY

SEA HARMONY is a 1957 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1984, most recently in October 1995, along with 144 deficiencies.

Records from 1984 to 1995. Most recent: inspection, 14 October 1995.

Built
1957
Last inspected
14 October 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5339212 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222803
Flag
BAHAMAS, THE
—
Maury page id
psix-222803

Inspections, by type

…with no type recorded33
Years with a record 11 calendar years (1984–1995)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it24413 - Convention (Subpart B), Gross Ton
24413 - Regulatory (Subpart C or D), Gross Ton
13881 - Regulatory (Subpart C or D), Net Ton
4978 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PEBBLE BEACH Tank Barge · MISLE 50114 · 20 September 1992 · activity 49283RIO Passenger (Inspected) · MISLE 222414 · 20 September 1992 · activity 49283HENNA Passenger (Inspected) · MISLE 270122 · 20 September 1992 · activity 49283

Inspection history · 60

14 October 1995 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1189768
29 August 1995 Control Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1374373
28 August 1995 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1193313
24 August 1995 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1183712
3 August 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 755148
27 July 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 32503
27 July 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 194840
23 July 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 194839
23 July 1995 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 761476
22 July 1995 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 189121
22 June 1995 Damage Survey · Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1428509
7 June 1995 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1407496
13 May 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 378288
13 May 1995 Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1402039
23 August 1994 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1470898
31 May 1994 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1412650
25 May 1994 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1359815
23 May 1994 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1412648
22 May 1994 Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1438182
16 May 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 710823
15 May 1994 Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1169913
14 May 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 366709
12 August 1993 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1403672
23 July 1993 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 844504
17 May 1993 Administrative
Administrative · Commandant (CG-CVC) · Activity 1149248
15 May 1993 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1146676
15 May 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1149979
20 September 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 49283
13 August 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 464004
18 June 1992 Certificate of Compliance · Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1267539
27 May 1992 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 494043
16 May 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 350799
30 October 1991 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 666722
30 October 1991 Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 680993
6 October 1991 Certificate of Compliance
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1251390
18 September 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 345949
29 August 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1310779
10 July 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1310783
14 June 1991 Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 933710
11 October 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 921803
22 July 1990 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1226847
31 May 1990 Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1218623
22 December 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 908209
13 October 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1039759
23 June 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1198066
21 April 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 892453
24 March 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 329110
24 March 1989 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1342168
24 March 1989 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1342287
7 July 1988 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1034851
26 May 1988 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1194045
18 May 1988 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1044389
17 May 1988 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1348372
9 May 1988 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1348846
13 April 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1307595
15 December 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 305971
19 August 1985 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1297188
31 May 1985 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 302184
25 November 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 299388
4 September 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 296721

Deficiency record · 144

Documentation
Issued 29 August 1995 Resolved
SUBMIT REPORT OF ASBESTOS MONITORING WHICH IS TO BE CONDUCTED WHEN THE VESSEL HAS RETURNED FROM IT'S FIRST TRIP AND HAS ARRIVED IN CANADA. THE MONITORS MUST BE PLACED AS SOON AFTER ARRIVAL AS POSSIBLE.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 29 August 1995 Resolved
ONCE FINAL COLOR PLANS HAVE BEEN COMPLETED OF THE FIRE CONTROL PLAN SUBMIT 2 COPIES TO [name withheld], SEATTLE, WA.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Electrical
Issued 22 June 1995 Resolved
Non-fire resistant material in cable transists through stairtower and main verticle zone boundaries (crew stairtower, forward end of MVZ 4) must be removed and replaced with material acceptable to the Administration.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 22 June 1995 Resolved
Compliance with the requirements of SOLAS 74, II-1/24 was not adequately documented. Ship's safety officer was not aware of SOLAS requirements.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Navigation
Issued 22 June 1995 Resolved
Could not find evidence that quarterly emergency steering drills required by SOLAS 74 V/19-2(d) are being conducted.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 22 June 1995 Resolved
Weather deck over port side emergency generator space is wasted in way of deck seam; painted canvas was applied over wasted weld/deck.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Documentation
Issued 22 June 1995 Resolved
The master could not provide evidence he is verifying the vessel is in compliance with stability criteria required by SOLAS 74, II-1/8.7.4. Stability information required by SOLAS 74, II-1/8.7
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Documentation
Issued 22 June 1995 Resolved
Deck officers (including [name withheld]) could not locate the stability information required by SOLAS 74, II-1/8.7.1.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Documentation
Issued 22 June 1995 Resolved
The muster list required by SOLAS 74, III/53 did not include the information required by paragraphs 1, 3, 4. In addition the muster list isnot prepared before the vessel sails as required by paragraph 6 (crew numbers not assigned to new crew members until day after vessel sails).
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Lifesaving
Issued 22 June 1995 Resolved
The material condition of lifeboats on the port and starboard side did not meet the requirements of SOLAS 74, III/19.2 (ship's crew identified four out of 14 lifeboats which met minimum requirements prior to being towed from Whittier).
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Lifesaving
Issued 22 June 1995 Resolved
Ship's officers could not provide an inspection checklist required by SOLAS74, III/52.1. Weekly inspections were logged, however documentation on board not sufficient to verify extent of inspections/periodic maintenance schedule.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Fire Fighting
Issued 22 June 1995 Resolved
Demonstrate all fire screen doors self closing per SOLAS 48 II/29(e) to thesatisfaction of the cognizant Officer in Charge, Marine Inspection.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Fire Fighting
Issued 22 June 1995 Resolved
Demonstrate all fire screen doors are smoke tight and acceptable to the Administration.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Fire Fighting
Issued 22 June 1995 Resolved
Demonstrate proper operation of all fire dampers throughout the ship to thesatisfaction of the cognizant Officer in Charge, Marine Inspection. (Several fire dampers located in spaces inside of fan rooms.)
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Navigation
Issued 22 June 1995 Resolved
Port steering pump shows evidence that seal requires replacement; covered cans in place to collect leaking oil.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 22 June 1995 Resolved
Deck in fan room for galley ventilation system heavily wasted.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Electrical
Issued 22 June 1995 Resolved
Electrical cable in areas affected by smoke painted over without being cleaned resulting in increasing fire load due to trapped carbon on cable.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Lifesaving
Issued 22 June 1995 Resolved
REPAIR GEARBOX/SHAFTING #15 LIFEBOAT.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Fire Fighting
Issued 22 June 1995 Resolved
REVERIFY STRUCTURAL FIRE PROTECTION IN ACCORDANCE WITH APPROVED STUCTURAL FIRE PROTECTION PLANS.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 22 June 1995 Resolved
Tank top for heavy oil tank in stabilizer room has concrete patch; patch appears to be leaking.
Condition: Unknown
Due 31 August 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 22 June 1995 Resolved
Rudder stock packing is leaking approximately 10-15 gallon/hour.
Condition: Unknown
Due 31 August 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 22 June 1995 Resolved
Knife edges for weather tight windows on the upper deck wasted; windows no longer weather tight.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Accommodation/Occupational Safety
Issued 22 June 1995 Resolved
Noted a variety of ILO-147 discrepancies throughout crew spaces (including broken sink drains, poor ventilation, general housekeeping).
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Construction/Loadline
Issued 22 June 1995 Resolved
Weather deck wasted in way of funnel in port side emergency generator space.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Electrical
Issued 22 June 1995 Resolved
PROVE SATISFACTORY OPERATION OF EMERGENCY FIRE PUMP.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Electrical
Issued 22 June 1995 Resolved
REPAIR ALL EMERGENCY LIGHTS ON "C" DECK IN VICINITY OF ENGINEROOM. REVERIFYALL EMERGENCY LIGHTS.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Lifesaving
Issued 22 June 1995 Resolved
REPAIR FRACTURE IN DAVIT ARM AFT CABLE PULLEY, #2 LIFEBOAT.
Condition: Unknown
Due 22 June 1995
Resolved 22 June 1995
Accommodation/Occupational Safety
Issued 13 May 1995 Resolved
PROPERLY REMOVE AND STOW GARBAGE FROM CARGO LOADING DECK.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Lifesaving
Issued 13 May 1995 Resolved
PROPERLY REPAIR TORN GUNWALE LOCATED FORWARD ON STARBOARD SIDE OF LIFE BOATNO. 10.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Accommodation/Occupational Safety
Issued 13 May 1995 Resolved
PROPERLY REPAIR WASTED VENTILATION DUCTING LOCATED NEXT TO THE PORT SIDE MAIN STACK.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Unknown
Issued 13 May 1995 Resolved
PROPERLY REPAIR LEAKING 1 1/2" PIPE LOCATED JUST AFT OF WATERTIGHT DOOR NO.18.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Construction/Loadline
Issued 13 May 1995 Resolved
PROPERLY REPLACE WASTED BOLTS ON STARBOARD PORTHOLE LOCATED IN CARPENTRY SHOP AND DEMENTRATE PROPER CLOSURE.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Accommodation/Occupational Safety
Issued 13 May 1995 Resolved
PROVIDE PROPER SCREENS FOR VENTS LOCATED IN CREW HEAD JUST AFT OF CARPENTRYSHOP. HEADS TO BE THOROUGHLY CLEANED.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Construction/Loadline
Issued 13 May 1995 Resolved
PROPERLY REPAIR EIGHT INCH CRACK ONPORT CHAIN GUIDE TUBE LOCATED IN WINCH MOTOR ROOM.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 13 May 1995 Resolved
PROPERLY INSTALL PORTABLE FIRE EXTINGUISHER LOCATED AT FRAME E23 PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Navigation
Issued 13 May 1995 Resolved
PROPERLY REPAIR HYDRAULIC LEAK ON PORT AND STAR BOARD PROPELLER PITCH CONTROL PUMP.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 13 May 1995 Resolved
PROPERLY REPAIR AND DEMONSTRATE PROPER OPERATION OF FAULTY REGULATOR ON OBAFOR FIRE SQUAD NO. 3.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Electrical
Issued 13 May 1995 Resolved
PROPERLY INSTALL FLOOR PLATE LOCATED BEHIND THE CONTROL BOOTH OF THE MAIN SWITCH BOARD IN THE ENGINE ROOM.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Fire Fighting
Issued 13 May 1995 Resolved
PROPERLY REPAIR LEAKING FLANGE ON PORT SIDE FIRE MAIN CROSS CONNECTOR TO MAIN DIESEL ENGINE COOLING (THIS HAS BEEN PREVIOUSLY REPAIRED).
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Construction/Loadline
Issued 13 May 1995 Resolved
PROPERLY REPAIR TO GOOD METAL WASTED DECK ABOUT FOUR FEET AROUND HATCH WHICH LEADS TO LOWER PAINT LOCKER IN BOATSWAIN HOLE.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 13 May 1995 Resolved
DEMONSTRATE PROPER OPERATION OF LATCH FOR FIRE SCREEN DOOR NO. P-18.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Fire Fighting
Issued 13 May 1995 Resolved
PROVIDE EQUIPMENT LIST FOR ALL FIRE LOCKERS.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Unknown
Issued 13 May 1995 Resolved
PROPERLY REPAIR SIGHT GLASS TO STARBOARD FRESH WATER TANK.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Engineering
Issued 13 May 1995 Resolved
PROPERLY REPAIR LEAKING FLANGE TO STARBOARD OVERBOARD DISCHARGE FROM THE HOT WELL CONDENSER.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Lifesaving
Issued 13 May 1995 Resolved
PROVIDE PROPERLY WORKING LIGHTS FOR LIFE RINGS LOCATED AT NO. 11 AND NO. 15LIFEBOAT STATIONS.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Lifesaving
Issued 13 May 1995 Resolved
PROPERLY INSTALL AND PROVIDE SATISFACTORY OPERATION OF LIMIT SWITCH FOR LAUNCH NO. 13.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Construction/Loadline
Issued 13 May 1995 Resolved
PROPERLY REPAIR WASTED HATCH COVER ON PAINT LOCKER ESCAPE HATCH LOCATED FORWARD ON MAIN DECK BETWEEN ANCHOR WINCHES.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Lifesaving
Issued 13 May 1995 Resolved
PROPERL REPAIR AND SHOW SATISFACTORY OPERATION OF LAUNCH NO. 13.
Condition: Unknown
Due 13 May 1995
Resolved 13 May 1995
Lifesaving
Issued 31 May 1994 Resolved
INSTALL AND PROPERLY BRACE THE BATTERY LOCATED AFT OF THE STBD ENGINE ON NO. 13 TENDER.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Lifesaving
Issued 31 May 1994 Resolved
CLEAN THE BILGES OF NO. 13 TENDER AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Lifesaving
Issued 31 May 1994 Resolved
AFFECT PROPER REPAIRS TO EXHAUST LINE, NO. 13 TENDER; RED-HAND PATCH IS NOTAN APPROPRIATE REPAIR.
Condition: Unknown
Due 31 May 1994
Resolved 31 May 1994
Lifesaving
Issued 15 May 1994 Resolved
PROPERLY SECURE THE MOTOR CONTROL BOX FOR WEATHER, LIFEBOAT # 16.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
REMOVE HOLD BACK HOOKS FROM THE FSDs B-16, B-27, & D-5.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
REMOVE, OR PROPERLY DEAD-END THE WIRING LOCATED BEHIND FSD # M-8._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
MAKE PERMANENT REPAIRS TO FOREPEAK ON THE # 12 LIFEBOAT/TENDER. NOTED COPIOUS AMOUNT OF REDHAND EPOXY REPAIRS ON INTERIOR.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
RENEW WATER TANK ACCESS COVER BOLTS, LIFEBOAT # 4._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
REPAIR THE SALT WATER COOLING LEAK IN WAY OF FORWARD STARBOARD GENERATOR HEAT EXCHANGER.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Accommodation/Occupational Safety
Issued 15 May 1994 Resolved
REPAIR STEAM PIPE LEAK IN WAY OF # 2 LUBE OIL PURIFIER HEATER.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Accommodation/Occupational Safety
Issued 15 May 1994 Resolved
FIX LOW PRESSURE STEAM LEAK ON TOP OF WATER HEATER TANK IN ENGINEROOM, OPENSTAIRTOWER.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Accommodation/Occupational Safety
Issued 15 May 1994 Resolved
REPLACE THE LEAKING VALVE (VALVE HOUSING) ON HOT WATER SYSTEM PIPING IN WAYOF ENGINEROOM OPEN STAIRTOWER.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Accommodation/Occupational Safety
Issued 15 May 1994 Resolved
COMPLETE PROPER REPAIR OF PINHOLE LEAK IN LOW PRESSURE WATER HEATER TANK, LOWER PIPE WELDMENT, ENGINEROOM OPEN STAIRTOWER.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Accommodation/Occupational Safety
Issued 15 May 1994 Resolved
MAKE PERMANENT REPAIR TO BILGE DISCHARGE PIPING (ELBOW) IN WAY OF SOFT PATCH.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Engineering
Issued 15 May 1994 Resolved
REPAIR OR REPLACE THE MECHANICAL SEAL ON THE COOLING WATER PUMP FOR THE STBD MAIN PROPULSION DIESEL ENGINE.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Accommodation/Occupational Safety
Issued 15 May 1994 Resolved
PROPERLY REPAIR FRESH WATER PIPE IN SHAFT ALLEY NEAR THE WATERTIGHT DOOR. PIPE HAS A SOFT PATCH.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
REPAIR HOLED PIPING IN FIXED FOAM SYSTEM CABINET IN WAY OF CROSS CONNECTIONPIPING BETWEEN F1 AND F2.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
REMOVE UNUSED WIRING OR PROPERLY DEAD-END IN THE JUNCTION BOX IN WAY OF LIFEBOAT #9, #10 AND #14.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
RENEW KICK PIPE COVERING FOR LIFEBOAT #1 MOTOR CONTROLLER WIRING.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
PROVIDE SCREEN GUARD TO SUPPLY VENT BLOWER IN MAIN CONTROL.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
PROVIDE COVER FOR LIGHTS IN MAIN CO2 ROOM.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
RENEW HANDGUARD FOR BLOWER IN FAN ROOM 33.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
RENEW THE LIFELINE FITTINGS ON LIFEBOAT # 16 & # 10. (WORKLIST ITTEMS 61 & 62)
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
Provide a handle for the fire damper located on the bridge deck, pantry, port side.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
PROPERLY MARK THE ACCESS DOOR FOR FIRE DAMPER LOCATED IN FAN ROOM 33.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
PROVIDE AN APPROPRIATE SPANNER WRENCH AT FIRESTATION #1.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
REMOVE THE HOLD BACK HOOK FOR FSD A-27.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
REMOVE THE LOCK FROM FSD NO B-13.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
REMOVE LOCKS AND PROVIDE A HANDLE FOR THE LIFEJACKET LOCKER T-5 & THE ADULTLIFEJACKET LOCKER ADJACENT TO IT.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
PROVE PROPER OPERATION OF FSD # UP-3.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Accommodation/Occupational Safety
Issued 15 May 1994 Resolved
REPAIR/REPLACE WASTED GUARDRAIL ADJACENT TO LIFEBOAT # 8, AND LIFEBOAT # 10.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
BLANK-OFF THE UNUSED PANEL SWITCHES IN WAY OF THE MAIN CONSOLE SWITCHBOARD (TOTAL OF 9).
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT # 12: REPAIR FRACTURED GRABRAIL AT STBD EMBARCATION; PROPERLY MOUNT STERN LIGHT & PROVE OPERATIONAL; PROPERLY REPAIR SPLICED BATTERY CABLES. (WORKLIST ITEMS 43 & 44)
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
# 9 L/B MAKE PERMANENT REPAIRS TO THE HULL IN WAY OF WASTAGE, NEAR MIDSHIPSDRAIN. FRP PATCHED.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Electrical
Issued 15 May 1994 Resolved
FREE UP THE EMERGENCY AND FLOOD LIGHT SWIVEL MOUNTS FOR THE LIFEBOAT DECK._x001C_MOUNTS ARE FROZEN.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
RENEW OARLOCKS IN THE FOR #5 LIFEBOAT.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Construction/Loadline
Issued 15 May 1994 Resolved
PROVIDE PROPOSAL TO RENEW WASTED UNDER DECK TRANSVERSE BEAMS FOR THE BRIDGEDECK. WASTAGE IS TO EXPOSED BEAMS WHICH ARE VISIBLE FROM THE BOAT DECK NEAR THE LIFEBOATS. BOTH PORT AND STBD SIDE.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
MAKE OPERABLE FSD # A-19. (BETWEEN A & B DECK AT BOTTOM OF STAIRWELL). IF DOOR IS TO BE SEALED CLOSED, CLOSE OFF THE STAIRWELL, AND ASSURE THAT PASSENGER AND CREW ACCESS/EGRESS IS ADEQUATE.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
#13 LIFEBOAT/TENDER; PROPERLY REPAIR EXHAUST LINE, RED HAND PATCH IS NOT APPROPRIATE REPAIR.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
#13 LIFEBOAT/TENDER: INSTALL AND PROPERLY BRACE THE BATTERY LOCATED AFT OF THE STBD ENGINE.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
#13, 14, 15 AND 16 LIFEBOATS (OR TENDERS); CLEAN THE BILGES, MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
REPAIR THE HANDLE FOR THE DOOR, STBD SIDE, CREW'S DISCO._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
CONNECT THE HOSE TO THE FIRE MAIN AT STAIONS B9,B11, BR5, BR2, UP2, UP4A, PIC, P1B, & A11.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Unknown
Issued 15 May 1994 Resolved
SECURE OXYGEN BOTTLES IN "DONKERE KAMER" ROOM
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
REPLACE THE MISSING FLANGE BOLTS FOR FOAM PIPING IN THE FIXED FOAM SYSTEM CABINET.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
INSTALL NOZZLE ON FIREHOSE, STATION B-9._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
FOR LIFEBOAT # 7: REPAIR FWD GRIPE ASSEMBLY, (BROKEN AT GUNNEL); SECURE LIFEBOAT COVER FRAME, BROKEN MOUNTS; RENEW CRACKED OAR. [ITEMS 30/31 & 32 ON THE WORKLIST].
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT #11, AFT DAVIT ARM, LOWER DAVIT ROLLER, REAR ROLLER IS FROZEN. FREE UP AND PROVE OPERATION.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT #15, REPLACE BROKEN HATCHET.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT # 16, REPAIR FRACTURED GUNNEL, PORTSIDE, AFT.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT # 4, REPAIR FORWARD BOAT HOOK, PENETRATION THROUGH FOREDECK AT GUNNEL IS LOOSE.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT # 14; FWD DAVIT ARM, UPPER WIRE SHEAVE WHEEL ON THE AFT SIDE OF DAVIT, SHEAVE IS FRACTURED AT THE EDGE.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
RENEW FIREMAIN STAND PIPES WHICH ARE SOFT PATCHED, TOTAL OF FOUR ON THE BRIDGE AND BOAT DECK.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT # 1 DAVITS, REPAIR DETERIOATED SAFETY CABLE, CABLE EYE IS ROTTED. CABLE SPANS BETWEEN THE GRAVITY DAVIT MECHANICAL SECURING HOOKS.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
LIFEBOAT # 16; REPAIR LEAKING HYDRAULIC SYSTEM & PROPERLY MOUNT FIRE EXTINGUISHER.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
REPAIR WASTED PAD EYE FOR BOAT LAUNCH PLATFORM BETWEEN LIFEBOATS #1 & 3. BOAT LAUNCH PLATFORM IS LOWERED ON A CABLE TO SIDEPORT, FACILITATES PASSENGER ACCESS TO TENDERS.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
REPAIR AND PROVE OPERATION OF LIMIT SWITCHES ON THE LIFEBOATS #6, #7, #10, #11, & #14.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
INSTALL PROPER MECHANICAL PLUGS FOR DRAINS ON LIFEBOAT # 12, PLUG FOUND BROKEN._x001C_
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
#14 L/B, REPAIR AFT BOAT HOOK BRACE AT THE STERN GUNNEL. REINFORCING RING IS DETERIORATED.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Lifesaving
Issued 15 May 1994 Resolved
REPAIR RING BUOY LIGHT, RING BUOY LOCATED ON BOAT DECK, STBD SIDE, AFT.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Fire Fighting
Issued 15 May 1994 Resolved
PROVIDE AN APPROPRIATE SPANNER WRENCH FOR FIRESTATION B-4.
Condition: Unknown
Due 15 May 1994
Resolved 15 May 1994
Navigation
Issued 14 May 1994 Resolved
U.S. CHART 18773 OR ITS EQUIVELANT NOT ONBOARD AND CURRENTLY CORRECTED.
Condition: Unknown
Due 30 May 1994
Resolved 20 May 1994
Navigation
Issued 14 May 1994 Resolved
U.S. COAST PILOT VOL. 7, 1994 OR ITS EQUIVELANT NOT ONBOARD AND CURRENTLY CORRECTED.
Condition: Unknown
Due 30 May 1994
Resolved 20 May 1994
Navigation
Issued 14 May 1994 Resolved
U.S. LIGHT LIST VOL. VI, 1992 NOT CURRENTLY CORRECTED; MISSING NOTICE TO MARINER CORRECTIONS AS FOLLOWS: 1993-15,16,17,18,19,20,21,22,23,24,25, 26,27,28,29,30,31,32,33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53. 1994-1,2,3,4,5,6,7,8,10.
Condition: Unknown
Due 30 May 1994
Resolved 20 May 1994
Documentation
Issued 14 May 1994 Resolved
OIL RECORD BOOK DID NOT CONTAIN ENTRIES FOR THE RECEIVING OF FUEL OIL.
Condition: Unknown
Due 3 June 1994
Resolved 3 June 1994
Documentation
Issued 12 August 1993 Resolved
Correct via the vessel's Classification Society the International loadline certificate to correctly reflect the assigned C1 and Freshwater marks, and mark hull accordingly.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Lifesaving
Issued 12 August 1993 Resolved
Demonstrate proper operation of lifeboat #16 winch brake in the presence ofa USCG marine inspector.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Fire Fighting
Issued 12 August 1993 Resolved
Hold off posting the vessel's new fire control plan until all modificationsare made during your drydock period planned for September 1993. Note that the fire control plan must be approved by the vessel's Classification Society or home government inspection office.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Lifesaving
Issued 12 August 1993 Resolved
Demonstrate proper operation of the propulsion equipment in all modes for lifeboat #4 in the presence of a marine inspector.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Engineering
Issued 12 August 1993 Resolved
Realign ventilation shutdown damper system for the engineroom so it can be mechanically operated as designed.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Electrical
Issued 12 August 1993 Resolved
Repair and make operational explosion proof lights and fixtures in the forward paint locker.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Electrical
Issued 12 August 1993 Resolved
Replace the light fixtures over the work bench in the after part of the paint locker with an explosion proof light and fixture.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Lifesaving
Issued 12 August 1993 Resolved
Repair or replace damaged lens covers and make operational all embarkation deck side shell lights.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Lifesaving
Issued 12 August 1993 Resolved
Inspect and repair/replace all wasted/corroded parts/assemblies of flemminggear, releasing hooks and foundations, and single point release mechanisms on all lifeboats/tenders as applicable.
Condition: Unknown
Due 12 August 1993
Resolved 12 August 1993
Construction/Loadline
Issued 12 August 1993 Resolved
Repair open electrical connections noted in watertight door locker #8.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Fire Fighting
Issued 12 August 1993 Resolved
Repair and make operational fire dampers in fan rooms #14 , #24, and #33.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Fire Fighting
Issued 12 August 1993 Resolved
Recharge fire extinguishers E-1, E-13A, E-15, E-19, B-17A, and replace missing fire extinguisher E-24.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Fire Fighting
Issued 12 August 1993 Resolved
Fire Station B-8 replace missing fire nozzle and for Fire Station B-6 recharge dry chemical fire extinguisher.
Condition: Unknown
Due 26 August 1993
Resolved 27 August 1993
Lifesaving
Issued 15 May 1993 Resolved
RENEW RETROREFLECTIVE TAPE ON LIFEJACKETS AS NECESSARY. (FOUND ABOUT 1 IN 20 TO NEED NEW TAPE ON UPPER FRONT.) NOTIFY THE LOCAL USCG MARINE SAFETY OFFICE WHEN COMPLETED.
Condition: Unknown
Due 15 May 1993
Resolved 15 May 1993
Fire Fighting
Issued 15 May 1993 Resolved
PROVIDE UPDATED FIRE CONTROL PLANS SHOWING ALL MODIFICATIONS, INCLUDING THEADDITION OF A NEW FIRE DOOR AT THE STAIRWAY NEAR THE CREW'S LOUNGE ON B DECK. THIS ITEM IS TO BE COMPLETED BY THE END OF THE NEXT SCHEDULED DRYDOCKING (PLANNED FOR OCTOBER 1993).
Condition: Unknown
Due 15 May 1993
Resolved 15 May 1993
Documentation
Issued 16 May 1992 Resolved
OIL RECORD BOOK WAS NOT SIGNED BY THE MASTER ON EACH PAGE.
Condition: Unknown
Due 16 May 1992
Resolved 18 May 1992
Unknown
Issued 31 May 1990 Resolved
CERTIFICATE IS ISSUED SUBJECT TO DETERMINATION BY THE COMMANDANT AS TO WHETHER THE MODS COMPLETED IN 1987 CONSTITUTE A MAJOR MOD, AS APPEALED BY VES- SEL AGENT ON JUNE 14, 1990.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Engineering
Issued 9 May 1988 Resolved
TEMPORARILY REPAIR AREA WHERE PORT FUEL OIL SETTLING TANK IS LEAKING THRU BULKHEAD TO MASSAGE ROOM AND THEN THROUGH DECK TO STABILIZER ROOM. RESTOREOILTIGHTNESS OF BULKHEAD AND FUMETIGHTNESS OF DECK; ENSURE STRUCTURAL FIRE PROTECTION LEVEL OF BOTH IS EQUAL TO EXISTING DESIGN.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Fire Fighting
Issued 9 May 1988 Resolved
REPLACE ALL STORED CHARGE DRY CHEMICAL EXTINGUISHERS SHOWING "DISCHARGE" ON GAUGE. CHECK VESSEL CAREFULLY FOR ADDITIONAL DISCHARGED EXTINGUISHERS. THESE WERE NOTED IN THE AFT FIRE EQUIPMENT LOCKER, ENGINEROOM AND AFT CREW SPACES.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Navigation
Issued 9 May 1988 Resolved
PROVIDE CURRENT COPIES OF THE FOLLOWING NAVIGATION PUBLICATIONS; U.S. COAST PILOT, COAST GUARD LIGHT LIST, TIDE CURRENT TABLES.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Navigation
Issued 9 May 1988 Resolved
UPDATE NAVIGATION CHARTS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Fire Fighting
Issued 9 May 1988 Resolved
DRILL CREW IN F/FIGHTING ORG, PARTICULARLY WITH REGARD TO OFFICERS & SCENE LDRS AWARENESS OF VSL SYSTEMS, SURROUNDING COMPARTMENTS, ETC. IT IS STRONG-LY RECOMMENDED THAT THE EXISTING PLANS BE IMPROVED, REDUCED, LAMINATED AND MADE AVAIL. BOTH ON THE BRIDGE & AT THE SQUAD MUSTER PTS. OR EQUIP. LOCKER.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Lifesaving
Issued 9 May 1988 Resolved
DRILL CREW IN BOAT HANDLING, PARTICULARLY WITH REGARD TO SAFE LOWERING AND RAISING PROCEDURES.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Lifesaving
Issued 9 May 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Engineering
Issued 9 May 1988 Resolved
CLEAN UP EXCESS OIL IN MACHINERY SPACES, ESPECIALLY AROUND MAIN ENGINES, ONTOPS OF SETTLING TANKS AND UNDER PROPELLER SHAFTS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Engineering
Issued 9 May 1988 Resolved
PERMANENTLY REPAIR DEFICIENCY #1 TO THE SATISFACTION OF THE FLAG ADMINISTRATION AND CLASSIFICATION SOCIETY.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Fire Fighting
Issued 9 May 1988 Resolved
REPLACE SMALL AREAS OF STRUC. FIRE PROTECTION INSULATION WHERE REMOVED FOR WORK ON PIPES OR PIPE HANGERS. THERE IS 1 LARGE AREA IN THE PORT SIDE OF ER CASING (AROUND A HEAVY BEAM SUPP EXHAUST PIPE) & SMALL AREAS IN BOTH THECASING AND AT THE FORWARD BOUNDARY OF EACH OF THE TWO NEW ACCOMMODATIONS.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Fire Fighting
Issued 9 May 1988 Resolved
THE FORWARD OF THESE IS JUST BELOW THE OVERHEAD PANELLING IN THE AFT BULK- HEAD OF THE L-SHAPED PASSAGEWAY USED FOR ESCAPE FROM TWO ZONES, JUST TO PORT OF THE FIRE DOOR IN THE FORWARD BULKHEAD NEAR THE STBD END. THE AFT OF THESE IS JUST OFF THE DECK AND JUST TO PORT OF THE FIRE DOOR, ON THE
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Fire Fighting
Issued 9 May 1988 Resolved
AFT SIDE OF THE BOUNDARY BETWEEN NEW AND OLD SPACES, IN WAY OF A PIPE FLANGE.
Condition: Unknown
Due 9 May 1988
Resolved 9 May 1988
Fire Fighting
Issued 15 December 1985 Resolved
NUMEROUS FIRE SCREEN DOORS THROUGHOUT VESSEL DID NOT LATCH FULLY CLOSED. DOORS ADJUSTED AND CORRECTED PRIOR TO COMPLETION OF EXAM.
Condition: Unknown
Due 15 December 1985
Resolved 15 December 1985
Navigation
Issued 15 December 1985 Resolved
STEERING GEAR INSTRUCTIONS REQUIRED BY 33CFR164.35(K) NOT POSTED ON BRIDGE.
Condition: Unknown
Due 15 December 1985
Resolved 15 December 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.