Records from 1985 to 1992. Most recent: inspection, 8 March 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
8 March 1992
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1254720
26 November 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 654352
17 November 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 949238
20 March 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 462682
27 August 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 339007
27 August 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1246181
22 March 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 329133
22 March 1989
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1273994
19 February 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 321408
10 September 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 318348
13 April 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1026551
13 April 1987
Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329992
13 April 1987
Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331230
11 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 314756
8 February 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 306897
10 December 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 305727
Deck/Cargo
Issued 17 November 1991
Resolved
TEST OPS OF CARGO PUMP REMOTE TRIPS(NOT TESTED STX) PRIOR TO NEXT ARRIVAL U.S. WATERS BUT NLT 01DEC91.
Condition: Unknown
Due 17 November 1991
Resolved 17 November 1991
Deck/Cargo
Issued 17 November 1991
Resolved
MAKE PERMANENT REPAIRS TO CARGO LINE ON MAIN DECK PRIOR TO NEXT ARRIVAL U.S. WATERS BUT NLT 05DEC91.
Condition: Unknown
Due 17 November 1991
Resolved 17 November 1991
Accommodation/Occupational Safety
Issued 17 November 1991
Resolved
TEMPORARY PATCHES ON MSD FWD PORT SIDE. MAKE PERMANENT REPAIRS.
Condition: Unknown
Due 17 November 1991
Resolved 17 November 1991
Deck/Cargo
Issued 17 November 1991
Resolved
AS RESULT OF POLLUTION INCIDENT, CARGO LINES CONDITION SUSPECT. VSL REQUIRED TO HYDROSTATICALLY TEST ALL CARGO LINES TO NO LESS THAN 225PSI PRIOR TO NEXT ARRIVAL U.S. WATERS OR NLT 05DEC91.
Condition: Unknown
Due 17 November 1991
Resolved 17 November 1991
Navigation
Issued 10 September 1987
Resolved
PROVIDE REPAIRS & PROVE PROPER OPERATION OF THE AUTOMATIC RADAR PLOTTING AID ON BOARD. VESSEL WAS GRANTED A DEVIATION TO DEPART PATMS WITH IOPERABLE AUTOMATIC RADAR PLOTTING AID, PENDING REPAIR WHEN PARTS ARE RECEIVED.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987
Fire Fighting
Issued 11 March 1987
Resolved
PROVIDE A FIXED FIRE FIGHTING SYSTEM FOR THE PROTECTION OT THE FORWARD PUMP ROOM ON BOARD AND PROVE ADEQUATE INSTALLATION AND OPERATION TO THE SATISFACTION OF AN AUTHOREZED CLASS SOCIETY.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Fire Fighting
Issued 11 March 1987
Resolved
PROVIDE A FIXED FIRE FIGHTING SYSTEM FOR THE PAINT LOCKER ON BOARD AND PROVE ADEQUATE INSTALLATION AND OPERATION TO THE SATISFACTION OF AN AUTHORIZED CLASS SOCIETY.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Fire Fighting
Issued 11 March 1987
Resolved
PROVIDE A FIXED FIRE PROTECTION SYSTEM FOR CARGO TANK SPACES ON BOARD AND PROVE ADEQUATE INSTALLATION AND OPERATION TO THE SATISFACTION OF AN AUTHORIZED CLASS SOCIETY.
Condition: Unknown
Due 11 March 1987
Resolved 11 March 1987
Navigation
Issued 10 December 1985
Resolved
NO VISUAL ALARM FOR STEERING SYSTEM POWER FAILURE, A VIOLATION OF 33 CFR 164.39(A).
Condition: Unknown
Due 10 December 1985
Resolved 10 December 1985
Documentation
Issued 10 December 1985
Resolved
THE ANNUAL TEST AND INSPECTION OF THE CARGO PIPING AND HANDLING GEAR SYSTEMOVERDUE AS OF JUNE/JULY 85, A VIOLATION OF 33 CFR 155.820(B). LAST INSPECTION JULY 84.
Condition: Unknown
Due 10 December 1985
Resolved 10 December 1985
Deck/Cargo
Issued 10 December 1985
Resolved
INTAKE AND DISCHARGE CARGO LINES DETERIORATING ON ELBOW FLANGE CONNECTION LOCATED JUST INSIDE CARGO PUMP ROOM HOUSE.
Condition: Unknown
Due 10 December 1985
Resolved 10 December 1985