Records from 1985 to 1994. Most recent: inspection, 2 June 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
2 June 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 484790
7 April 1994
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 519430
31 March 1994
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 855635
11 March 1994
Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 854927
4 January 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 472964
25 October 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 333383
15 September 1989
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1024774
12 September 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 526619
27 March 1989
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 436497
5 October 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1043545
7 September 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 325406
7 September 1988
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1040423
10 March 1988
Control Verification
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1030812
9 September 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 318190
10 July 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1015869
15 May 1987
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1330928
23 April 1987
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1009787
15 January 1987
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1315287
2 January 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 462461
11 December 1986
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1309322
15 November 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 312600
5 February 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 525116
Documentation
Issued 11 March 1994
Resolved
Submit Class of flag state approved plans per NVIC 1-93 detailing bulkhead/deck construction; fire zone boundaries; fire barrier penetration details. Plans required in accordance with initial Control Verification requirements of NVIC.
Condition: Unknown
Due 11 June 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 11 March 1994
Resolved
Provide a gastight lighting fixture in the paint locker.
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Construction/Loadline
Issued 11 March 1994
Resolved
Effect permanent repairs to the #2 cargo hold tank top in way of wasted tank top. Noted as a condition of class with Lloyds (03DEC93).
Condition: Unknown
Due 31 October 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 11 March 1994
Resolved
Effect permanent repair to the fire screen doors; 08, B83, B101, 37. Doorsto be repaired prior to departing the Port of Jacksonville.
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Accommodation/Occupational Safety
Issued 11 March 1994
Resolved
Remove motor gas, oil and bottle gas containers from the flammable stores locker below deck, located stbd side forward.
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Documentation
Issued 11 March 1994
Resolved
Provide a waste management plan for MARPOL V items.
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Navigation
Issued 11 March 1994
Resolved
Repair aft deck steering helm station, pointer missing.
Condition: Unknown
Due 31 March 1994
Resolved 31 March 1994
Engineering
Issued 11 March 1994
Resolved
Reduce tailshaft water leakage to acceptable minimum leakage rate.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Fire Fighting
Issued 11 March 1994
Resolved
Test three on deck fire stations with vessels firemain pressure.
Condition: Unknown
Due 14 March 1994
Resolved 16 March 1994
Accommodation/Occupational Safety
Issued 11 March 1994
Resolved
Demonstrate proper operation of the forward MSD (Omnipure) unit.
Condition: Unknown
Due 16 March 1994
Resolved 16 March 1994
Fire Fighting
Issued 7 September 1988
Resolved
BULKHEAD PENETRATIONS AT FIRE DOORS 84, 86, 128, 137, 144, 154, AND 156 ARENOT BLOCKED OFF WITH STUFFING TUBES. WIRING PENETRATIONS THROUGH BULKHEAD NEED TO BE PROPERLY STUFFED.
Condition: Unknown
Due 7 September 1988
Resolved 7 September 1988
Fire Fighting
Issued 7 September 1988
Resolved
TEST OF FIRE FIGHTING SYSTEM REVEALED THREE HOSES WITH PINHOLE LEAKS NEAR CONNECTORS. TEST REMAINING HOSES AND RENEW LEAKING HOSES.
Condition: Unknown
Due 7 September 1988
Resolved 7 September 1988
Accommodation/Occupational Safety
Issued 7 September 1988
Resolved
VENTILATION DUCTING IN GALLEY HAS ACCUMULATION OF GREASE AND OIL. NO GREASETRAPS FILTERS IN PLACE. CLEAN GREASE FROM INSIDE VENTS AND INSTALL GREASE TRAP FILTERS.
Condition: Unknown
Due 7 September 1988
Resolved 7 September 1988
Electrical
Issued 7 September 1988
Resolved
PROVIDE RUBBER GROUNDING MAT IN FRONT OF EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 7 September 1988
Resolved 7 September 1988
Construction/Loadline
Issued 7 September 1988
Resolved
WATERTIGHT DOOR DOES NOT OPEN UNDER MANUAL CONTROL. REPAIR WATERTIGHT DOOR SO THAT IT CAN BE OPERATED REMOTELY BY HAND.
Condition: Unknown
Due 7 September 1988
Resolved 7 September 1988
Fire Fighting
Issued 23 April 1987
Resolved
REMOVE LOCK FROM EMERGENCY ESCAPE AND FIRE DOOR FD B113.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Fire Fighting
Issued 23 April 1987
Resolved
ADJUST FIRE DOOR FD 68 (PORT).
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Fire Fighting
Issued 23 April 1987
Resolved
DEMONSTRATE PROPER OPERATION OF FIREMAIN RELIEF DEVICE OR OBTAIN CLASSIFICATION SOCIETY APPROVAL TO REMOVE THE RELIEF DEVICE.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Fire Fighting
Issued 23 April 1987
Resolved
REPAIR PIN HOLE LEAK IN FIREMAIN PIPING NEAR FIRE PUMP IN MAIN ENGINEROOM.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Fire Fighting
Issued 23 April 1987
Resolved
OBTAIN CLASSIFICATION SOCIETY PLAN APPROVAL ON MODIFICATIONS MADE TO FIREMAIN PIPING.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987
Fire Fighting
Issued 23 April 1987
Resolved
INSTALL CAPTIVE CHAINS ON "ALL PURPOSE" FIRE NOZZLES.
Condition: Unknown
Due 23 April 1987
Resolved 23 April 1987