MAURY USCG vessel records Sign in
← All vessels

RIO COLORADO

RIO COLORADO is a 1967 tank ship. The Coast Guard has recorded 30 inspections since 1984, most recently in August 1991, along with 23 deficiencies.

Records from 1984 to 1991. Most recent: inspection, 1 August 1991.

Built
1967
Last inspected
1 August 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6712916 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
222918
Flag
UNITED KINGDOM
—
Maury page id
psix-222918

Inspections, by type

…with no type recorded26
Years with a record 8 calendar years (1984–1991)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it15842 - Regulatory (Subpart C or D), Gross Ton
10870 - Regulatory (Subpart C or D), Net Ton
25215 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

1 August 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 656106
7 May 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 472749
2 May 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 343699
5 November 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1213841
4 November 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 472017
27 June 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1218869
19 June 1990 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 926677
24 May 1990 Certificate of Compliance
Administrative · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1226653
22 May 1990 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 337277
8 January 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 469798
22 September 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 332733
5 September 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 332472
27 June 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 331244
13 May 1989 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 330347
13 May 1989 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1033160
17 September 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 470222
28 March 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 322202
25 March 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 322260
25 March 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1301579
5 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 529666
30 October 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1020304
23 June 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 316917
23 June 1987 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1015466
9 June 1987 Administrative
Administrative · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001752
2 April 1987 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 443651
21 June 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 309688
1 June 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 509646
28 October 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 526574
1 April 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 514646
8 September 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 297842

Deficiency record · 23

Documentation
Issued 2 May 1991 Resolved
33 CFR 155.740 THERE WERE NO OIL TRANSFER PROCEDURES ONBOARD FOR INSPECTION
Condition: Unknown
Due 2 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 2 May 1991 Resolved
33 CFR 151.25(h) EACH OPERATION IN OIL RECORD BOOK WAS NOT SIGNED BY THE PERSON IN CHARGE_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Construction/Loadline
Issued 24 May 1990 Resolved
MAKE PERMANENT REPAIRS TO THE WASTED PLATE ON THE MAIN DECK AS PER CLASS SOCIETY REQUIREMENT. TEMPORARY REPAIRS ACCEPTED IN THE INTERIM.
Condition: Unknown
Due 1 August 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 24 May 1990 Resolved
UPON COMPLETION OF THIS VOYAGE, THE VESSEL SHALL NOT ENTER U.S. WATERS UNTIL BOTH CARGO PUMPROOMS HAVE BEEN CLEANED OF ALL CARGO RESIDUE INBILGES.
Condition: Unknown
Due 24 May 1990
Resolved 24 May 1990
Unknown
Issued 27 June 1989 Resolved
A VIOLATION OF 33 CFR 155.310 IN THAT THE VSL DID NOT HAVE A FIXED CONTAINER OR ENCLOSED DECK AREA THAT, UNDER ALL SHIPS LOADING CONDITIONS, HAD A CAPACITY OF AT LEAST 1/2 BBL UNDER OR AROUND EACH OIL LOADING MANIFOLD AND OIL TRANSFER CONNECTION POINT.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Navigation
Issued 27 June 1989 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE U.S. COAST PILOT (VOL.3) USED BY THE VSL WAS NOT CORRECTED UP THRU NTMS 15/89, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO VSLS ROUTE FROM SMITH PT VA TO BALTIMORE HBR. NO FOREIGN EQUIVALENT O/B.
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 27 June 1989 Resolved
A VIOLATION OF 33 CFR 164.11(R) IN THAT THE SECONDARY RADAR REQ BY 33 CFR 164.37(A) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/WIN THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Navigation
Issued 27 June 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 June 1989
Resolved 27 June 1989
Deck/Cargo
Issued 13 May 1989 Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OTP REQ BY 33 CFR 155.720 WAS INCOMPLETE. THE OTP DID NOT CONTAIN A LIST OF EACH PRODUCT TRANSFERRED.
Condition: Unknown
Due 13 May 1989
Resolved 13 May 1989
Deck/Cargo
Issued 13 May 1989 Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OTP REQ BY 33 CFR 155.720 WAS INCOMPLETE. THE OTP DID NOT CONTAIN NUMBER OF PERSONS REQ ON DUTY DURING OIL TRANSFER OPERATIONS.
Condition: Unknown
Due 13 May 1989
Resolved 13 May 1989
Deck/Cargo
Issued 13 May 1989 Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OTP REQ BY THE 33 CFR 155.720 WERE INCOMPLETE. THE OTP DID NOT CONTAIN DUTIES BY TITLE OF EACH OFFICER, PERSON-IN-CHARGE, TANKERMAN, DECKHAND, ETC., REQ FOR EACH OIL TRANSFER OPERATION.
Condition: Unknown
Due 13 May 1989
Resolved 13 May 1989
Navigation
Issued 13 May 1989 Resolved
A VIO OF 33 CFR 164.11(R) IN THAT THE SECONDARY RADAR REQ BY 33 CFR 164.37 (A) WAS NOT MAINTAINED IN AN OPERABLE CONDITION WHILE THE VSL WAS U/W IN THE NAVIGABLE WATERS OF THE U.S.
Condition: Unknown
Due 13 May 1989
Resolved 13 May 1989
Documentation
Issued 25 March 1988 Resolved
A VIO OF 33 CFR 155.750 IN THAT THE OIL TRANSFER PROCEDURES REQUIRED BY 33 CFR 155.720 WERE INCOMPLETE, IN THAT THEY DID NOT CONTAIN THE REQUIRED INFO DESCRIBED IN 33 CFR 155.750 PARAGRAPHS (A)(1)(I), (A)(2)(III), (A)(3),(A)(4), (A)(6), (A)(8), & (A)(9).
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Unknown
Issued 25 March 1988 Resolved
CARGO TANK COMMON VENT RISER REQUIRES FLAME SCREEN REPLACEMENT. (INDIVIDUAL GOOSE NECK BENTS ON CARGO TANKS ARE SATISFACTORY FOR GRADE E CARGOES ONLY.)
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Electrical
Issued 23 June 1987 Resolved
MAKE OPERATIONAL THE EMERGENCY GENERATOR LOCATED FORWARD VIA THE HYDRAULIC START.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Electrical
Issued 23 June 1987 Resolved
EMERGENCY POWER COULD NOT BE GENERATED BY THE CATAPILLAR EMERGENCY GENERATOR LOCATED AFT.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Electrical
Issued 23 June 1987 Resolved
THE LIGHTING IN THE FOCSLE AREA WAS NOT OPERATIONAL.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Deck/Cargo
Issued 23 June 1987 Resolved
THE CARGO PIPING JOINT CONNECTION ON THE #4 CARGO PIPELINE LOCATED OVER #8 CENTER CARGO TANK NEEDS TO BE REPAIRED.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Electrical
Issued 23 June 1987 Resolved
THE LIGHTING FIXTURE HALF WAY DOWN THE AFT PUMPROOM WAS NOT OPERATIONAL.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Deck/Cargo
Issued 23 June 1987 Resolved
VESSEL DID NOT HAVE A STANDARD SHORE DISCHARGE CONNECTION ON BOARD.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Unknown
Issued 23 June 1987 Resolved
TWO ACETYLENE AND TWO OXYGEN COMPRESSED GAS CYLINDERS UTILIZED FOR WELDING WERE BEYOND THEIR HYDROSTATIC TEST DATE AS REQUIRED BY 46 CFR 147.04-1.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Unknown
Issued 23 June 1987 Resolved
REPLACE FLAME SCREEN IN GOOSENECK VENT AND REPAIR VALVE IN SUPPLY LINE OF CATAPILLAR GENERATOR FUEL TANK.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Deck/Cargo
Issued 23 June 1987 Resolved
ALL FLAME SCREENS IN REGARD TO THE CARGO TANK PRESSURE VACUUM VALVES NEED TO BE REPLACED WITH NEW AS ORGINAL.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.