CG found grease dripping from a ventilation in the galley above the stove.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 14 March 2007
Resolution: Crewmember cleaned the vent on the spot.
Fire Fighting › Means of Escape › Doorways
Issued 14 March 2007
Resolved
02 engine room doors were found not able to secure or not operating properly.
Action required: 705 - Other - as specified
Due 14 March 2007
Resolved 14 March 2007
Resolution: Engineer from vessel fixed problem on the spot.
Engineering › Steering Gear System › Pump
Issued 14 January 2007
Resolved
The steering gear pump was leaking hydraulic fluid. The steering test was satisfactory even with this leak.
Action required: 705 - Other - as specified
Resolved 2 February 2007
Resolution: The defect was rectified by the C/E and engine crewmembers with renewal inside oil rings. The following tests were carried out during the presence of class surveyor:
1. Emergency manual operation of steering
2. Normal steering operation from bilge.
Engineering › Generator (propulsion/auxiliary-electric) › Receptacle
Issued 27 June 2006
Resolved
Extensive leak in raw jacket water flange #2 port generator.
Action required: 705 - Other - as specified
Due 28 June 2006
Resolved 28 June 2006
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 27 June 2006
Resolved
Protection for lifeboat motor missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2006
Resolved 28 June 2006
Engineering › Lubricating Oil Service System › Piping
Issued 18 April 2006
Resolved
FOUND EXCESS OIL ON MACHINERY AND IN BILGES IN ENGINE ROOM. CLEAN MACHINERY AND PUMP BILGES. PROVE THERE ARE NO EXCESSIVE LEAKS FROM MACHINERY PRIOR TO NEXT US PORT TO THE SATISFACTION OF CLASS.
Action required: 705 - Other - as specified
Resolved 4 May 2006
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 15 February 2006
Resolved
FIX LEAK ON JACKET WATER TANKS FOR DIESEL GENERATOR.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 15 February 2006
No resolution recorded
REPLACE DECK GATES IN STEERING.
Action required: 705 - Other - as specified
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Communications › Internal Communications System › Portable Radios
Issued 15 February 2006
Resolved
REPAIR COMMUNICATIONS BETWEEN STEERING AND BRIDGE.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (hydraulic)
Issued 15 February 2006
Resolved
INSTALL FITTINGS ON RETURN LINE (HYDRAULIC).
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 15 February 2006
Resolved
REMOVE DEAD END CABLES IN STEERING.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 February 2006
Resolved
INSTALL PROTECTIVE COVER FOR AN ANCHOR LIGHT BREAKER.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Engineering › Sea-water System (primary cooling) › Pump
Issued 15 February 2006
Resolved
Demonstrate proper cooling operation of number 1 ship service generator.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: Proper cooling operation was demonstrated to the satisfaction of attending Coast Guard Inspector.
Fire Fighting › Fire Main › Condition
Issued 15 February 2006
Resolved
Repair fire main in area of emergency fire pump feed.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Fire Fighting › Emergency Fire Pumps › Capacity
Issued 15 February 2006
Resolved
Replace gasket on exhaust manifold of emergency fire pump.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Engineering › Lubricating Oil Storage/Transfer System › Pump
Issued 15 February 2006
Resolved
Repair electrical cables on starboard side lube oil pump.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Engineering › Diesel Engine (propulsion-direct drive) › Gear/Clutch Starter (air motor)
Issued 15 February 2006
Resolved
Remove dead end cable on main diesel engine.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Engineering › Compressed Air System (control) › Compressor
Issued 15 February 2006
Resolved
Repair/replace wiring on number 1 and 2 compressor.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Engineering › Lubricating Oil Service System › Purifier
Issued 15 February 2006
Resolved
Remove dead end cable above fuel oil purifier.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Engineering › Diesel Engine (propulsion-direct drive) › Gear, Timing
Issued 15 February 2006
Resolved
Repair/replace pyrometers on main diesel engine.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: Proper cooling operation was demonstrated to the satisfaction of attending Coast Guard Inspector.
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 15 February 2006
Resolved
Log pre-entry steering gear test in vessel logbook.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 15 February 2006
Resolved
Clean excess oil from machinery surfaces.
Action required: 705 - Other - as specified
Resolved 15 February 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 15 February 2006
Resolved
Clean 4th engineer storeroom.
Action required: 705 - Other - as specified
Resolved 29 March 2006
Resolution: According to Classification Survey Report issued by China Corporation Register of Shipping on 21FEB06.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 11 November 2005
Resolved
Remove personal effects from hospital space.
ILO Crew Accommodation Regulation 31
Action required: 15 - Rectify deficiencies by next port
Resolved 1 December 2005
Resolution: TO SATISFACTION OF ATTENDING MARINE INSPECTOR
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 11 November 2005
Resolved
Repair corroded bulkhead, s/bd boat deck engine room bulkhead
Action required: 15 - Rectify deficiencies by next port
Resolved 1 December 2005
Resolution: TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 11 November 2005
Resolved
Replace exhaust leak on emergency fire pump.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 December 2005
Resolution: TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR
Electrical › Electric Generation Source (service) › Generator
Issued 11 November 2005
Resolved
Ensure main generators (port and starboard) in engine rooms capable of paralleling and handling vessels electrical load.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 December 2005
Resolution: TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR
Electrical › Electric Generation Source (service) › Generator Cable
Issued 17 September 2004
Resolved
Replace port generator starting battery cables.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Resolution: Port side generator battery starter cable replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 September 2004
Resolved
Clean and service all starting batteries.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Resolution: All starter batteries cleaned and serviced.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 September 2004
Resolved
To satisfaction of Class-Redirect fuel drain lines and remove open buckets of fuel oil on main engines.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 17 September 2004
Resolved
Remove excess oil in bilge.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Engineering › Lubricating Oil Service System › Purifier
Issued 17 September 2004
Resolved
Replace/Repair cable on L/O purifier pump.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Engineering › Freshwater System (injector cooling) › Filling Line
Issued 17 September 2004
Resolved
Replace insulation on injector cooling lines.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Engineering › Generator (propulsion/auxiliary-electric) › Battery
Issued 17 September 2004
Resolved
Replace emergency generator starting battery.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 September 2004
Resolved
Demonstrate proper operation of emergency generator.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Electrical › Electric Supply System (service) › Cable
Issued 17 September 2004
Resolved
Remove dead end cable and seal stuffing tube on port side-stern.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Engineering › Compressed Air System (control) › Compressor
Issued 17 September 2004
Resolved
Remove/secure waste oil drums and oil on decks and equipment in the compressor house.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Construction/Loadline › Hull › Stiffener
Issued 17 September 2004
Resolved
Crop/renew wasted steel and stiffiners in the area of the deck of muster station from port to stbd side.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 22 November 2004
Resolution: Rcvd class report of completed repairs.
Construction/Loadline › Hull › Stiffener
Issued 17 September 2004
Resolved
Crop and renew wasted stiffners on the main deck, port and stbd side.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 8 October 2004
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 17 September 2004
Resolved
Thoroughly clean galley.
Action required: 705 - Other - as specified
Due 15 December 2004
Resolved 8 October 2004
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 17 September 2004
Resolved
Make permanent repairs to hinges on freezer door.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 October 2004
Lifesaving › Lifeboat
Issued 23 April 2004
Resolved
Port Lifeboat is missing reflective tape. Provide required amount of reflective tape on port lifeboat. LEGACY COMPONENT DESC: Hull
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004
Navigation › Piloting/Steering
Issued 23 April 2004
Resolved
Gyro power cable and breaker need to be permanently repaired. Current cable is a temporary fix. Properly secure
temporary cable, stuffing tubes, etc. LEGACY COMPONENT DESC: Gyro Compass
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004
Electrical › Electric Supply System (service)
Issued 23 April 2004
Resolved
Battery in ships emergency battery room is cracked and leaking. Replace with properly sized emergency battery. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004
Accommodation/Occupational Safety › Washroom/Toilet
Issued 23 April 2004
Resolved
Two urinals in crews head are inoperable due to improper piping. Make permanent repairs to piping for urinals. LEGACY COMPONENT DESC: Toilet
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004. The use supplied water and buckets for flushing is acceptable.
Electrical › Electrical Distribution System (service)
Issued 23 April 2004
Resolved
Control panel in A/C room contains deadend cables and wires that need to be removed or reconnected. Remove or
reconnect all deadend cables and wires. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004
Electrical › Electrical Distribution System (service)
Issued 23 April 2004
Resolved
Junction Box in A/C room has several unsealed openings. Properly seal all openings in A/C Room Junction Box. LEGACY COMPONENT DESC: Junction Box
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004
Accommodation/Occupational Safety › Occupational Safety
Issued 23 April 2004
Resolved
Bulkhead separating battery room from ship's passageway is holed. Seal hole in bulkead separting battery room
from ship's passageway.
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004
Fire Fighting › Emergency Fire Pumps
Issued 23 April 2004
Resolved
Lagging on emergency fire pump is wasted. Renew wasted lagging on the emergency fire pump.
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 27 May 2004
Resolution: Cleared item MSD Saipan Activity 2079444 dated 5/27/2004
Electrical › Electric Generation Source (service) › Generator
Issued 23 April 2004
Resolved
Ship's emergency generator found to have an oil leak. Repair oil leak at emergency generator.
Condition: Improper/Lack of Maintenance
Due 22 May 2004
Resolved 23 April 2004
Resolution: Source of leak was found to be a loose oil filter. Oil filter was properly tightened and the oil leak was secured.
Pollution Prevention/Response › Prevention Equipment
Issued 29 September 2003
Resolved
PROVIDE MARPOL PLACARD FOR OIL DISCHARGE
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 September 2003
Resolved
REPAIR/REPLACE THE WASTED PIPE ELBOW FROM MDE TO TURBO.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Lifesaving › Lifeboat
Issued 29 September 2003
Resolved
REPLACE AS NEEDED, SOLAS APPROVED RETRO FOR #1 AND #2 LIFEBOATS
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Construction/Loadline › Structures
Issued 29 September 2003
Resolved
REPAIR TO THE SATISFACTION OF CLASS. THE HOLED BULKHEAD AT THE BOAT DECK, BY #2 LIFEBOAT, UNDER A/C UNIT.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 29 September 2003
Resolved
PROVE PROPER OPERATION OF THE #1 AND #2 SSDG UNDER LOAD.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Engineering › Generator (propulsion/auxiliary-electric)
Issued 29 September 2003
Resolved
HAVE CLASS APRROVE THE INSTALLATION OF THE TEMPORARY GENERATOR MOUNTED ON THE AFT BOAT DECK, INCLUDING FUEL PIPING, STABILITY, AND ACCESS TO LIFEBOATS.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 22 April 2004
Resolution: Class inspected and approved emergency generator mounted on aft deck.
Fire Fighting › Miscellaneous Items
Issued 29 September 2003
Resolved
PROVIDE SPANNER WRENCH FOR FIRE BOX #9 IN E/R.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Accommodation/Occupational Safety › Potable Water System
Issued 29 September 2003
Resolved
PROVE PROPER OPERATION OF THE FRESH WATER OVERBOARD VALVE. REMOVE TEMP HOSES.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 29 September 2003
Resolved
CLEAN UP EXCESSIVE OIL IN THE ENGINE ROOM. WIPE DOWN ALL EQUIPMENT
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Operations/Management › Equipment Service/Testing
Issued 29 September 2003
Resolved
UPDATE VESSEL SPECIFICS FOR FIRE FIGHTING IN THE TRAINING MANUAL.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 October 2003
Lifesaving › Lifeboat Equipment
Issued 29 September 2003
Resolved
PROVIDE MAINTENANCE SCHEDULE FOR LIFE SAVING GEAR, INCLUDING RECORDS, AND THE CREWS DUTIES TO PREFORM ON THE GEAR.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Stability › Watertight Integrity
Issued 29 September 2003
Resolved
REPLACE/RENEW THE 4 MISSING WATERTIGHT DOORS ON THE AFT HOUSE.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Resolution: Fax No. 30-[phone withheld] from class states outside doors of captains deck and boat deck shall be only weathertight. Confirmed doors weathertight, advised Chief Engineer to provide additional gasket material to ensure best seal.
Stability › Weathertight Integrity
Issued 29 September 2003
Resolved
PROPERLY DEMONSRTATE THE ABILITY TO SECURE/SEAL ALL HATCHES ON THE SUPER STRUCTURE. REMOVE ALL WIRES, PIPES, ECT RUNNING THROUGH THESE FITTINGS.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 29 September 2003
Resolved
PROVIDE GLOBES AND CAGES ON ALL EXPOSED LIGHT BULBS THROUGHOUT THE VESSEL.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 29 September 2003
Resolved
REPAIR BROKEN LIGHT IN THE BATTERY ROOM AND REMOVE DEAD END WIRE.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 29 September 2003
Resolved
PROVIDE MECHANICAL PLUG AND ATTACHED LINE FOR ALL FUEL OIL CONTAINMENTS.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Lifesaving
Issued 29 September 2003
Resolved
REPLACE THE MISSING RING BUOY AND LIGHT, AFT OF BOSN LOCKER.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Deck/Cargo › Mooring/Anchoring
Issued 29 September 2003
Resolved
REPLACE THE ROTTEN BOW SPRING LINE.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Fire Fighting › Fire Main
Issued 29 September 2003
Resolved
REPAIR/REPLACE THE WASTED FIREMAIN PIPING, FORWARD, PORT SIDE
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 October 2003
Construction/Loadline › Penetrations
Issued 29 September 2003
Resolved
REPAIR HOLED VENT PIPE IN THE BOSN HOLD.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 October 2003
Construction/Loadline › Penetrations
Issued 29 September 2003
Resolved
REPAIR THE FORE PEAK VENT PIPE
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Construction/Loadline › Penetrations
Issued 29 September 2003
Resolved
MAKE REPAIRS TO THE BULKHEAD WHERE THE CO2 FITTING ENTERS THE SPACE.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Electrical
Issued 29 September 2003
Resolved
REPAIR /REPLACE THE ELECTRICAL WIRE TO THE CARGO ALARMS.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Construction/Loadline › Structures
Issued 29 September 2003
Resolved
REPAIR THE BREACH TO THE CLASS "A" BULKHEAD IN THE HOUSE, ABOVE WATERTIGHT DOOR.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 29 September 2003
Resolved
REPAIR OR REPLACE THE PORT AND STARBOARD ACCOMODATION LADDERS.
Action required: 15 - Rectify deficiencies by next port
Resolved 28 November 2003
Construction/Loadline › Structures
Issued 29 September 2003
Resolved
REPAIR TO THE SATIFACTION OF CLASS, ALL WASTAGE AROUND ENGINEROOM BULKHEAD WHERE IT MEETS THE HOUSE.
Action required: 705 - Other - as specified
Resolved 28 November 2003
Construction/Loadline › Structures
Issued 29 September 2003
Resolved
MAKE PERMANENT REPAIRS TO THE HOLED F/W PIPE AT THE FUNNEL DECK.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Accommodation/Occupational Safety › Ventilation
Issued 29 September 2003
Resolved
HAVE CLASS EVALUATE THE WASTED INSULATION IN THE STACK SPACE, REPLACE AS NECESSARY.
Action required: 705 - Other - as specified
Due 31 May 2004
Resolved 22 April 2004
Resolution: Class inspected and replaced wasted insulation in the stack space.
Fire Fighting › Firemans Outfit › Lifeline
Issued 29 September 2003
Resolved
PROVIDE FIRE PROOF LIFELINES FOR OUTFITS.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 October 2003
Operations/Management › Drills/Instruction › Fire
Issued 29 September 2003
Resolved
CONDUCT A SATIFACTORY FIRE DRILL.
Action required: 705 - Other - as specified
Resolved 2 October 2003
Fire Fighting › Structural - A Class Divisions
Issued 29 September 2003
Resolved
PROPERLY SECURE THE ELECTRICAL CABLES ENTERING THE ENGINEERING SPACE (BULKHEAD), NEAR THE E/R STORE ROOM.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 September 2003
Resolved
REMOVE ALL COMBUSTIBLE MATERIALS FROM THE ENGINEERING STORE ROOM.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 October 2003
Operations/Management › Cargo Transfer/Lightering
Issued 24 September 2003
Resolved
PROVIDE WRITTEN PROCEDURES FOR ALL FUELING ACTIVITIES.
LEGACY COMPONENT DESC: Conducted IAW Vessel Transfer Procedures
Action required: 15 - Rectify deficiencies by next port
Resolved 2 October 2003
Documentation
Issued 10 March 2003
Resolved
Prior to next U.S. port vessel to update its Certificate of Financial Responsibility (COFR) pursuant to 33 CFR 138 to reflect new operator.
Action required: 15 - Rectify deficiencies by next port
Resolved 29 September 2003
Fire Fighting › Emergency Fire Pumps
Issued 21 June 2002
Resolved
The emergency fire pump located below the main deck near forward cargo hold has an exhaust leak.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 June 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 June 2002
Resolved
The pain locker fixed CO2 system is not correctly installed. It consists of 2 portable extinguishers piped into the paint locker, 1 extinguisher was not connected.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Fire Fighting › Semiportable CO2 Fire Extinguishers › Securing Means
Issued 21 June 2002
Resolved
Portable extinguishers throughout the vessel are improperly mounted and/or secured. Some extinguishers are secured with rope or wire making them not available for immediate use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Fire Fighting › Combustible Materials
Issued 21 June 2002
Resolved
The flammables in the foscle deck compartment are not properly stowed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Fire Fighting › Combustible Materials
Issued 21 June 2002
Resolved
The flammables in the cargo engine compartment are not properly stowed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 21 June 2002
Resolved
The vent closure for the paint locker does not operate properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Fire Fighting › Structural - A Class Divisions
Issued 21 June 2002
Resolved
Provide proper closures for openings in galley port bulkhead. LEGACY COMPONENT DESC: Bulkheads - Main Galleys
Action required: 15 - Rectify deficiencies by next port
Resolved 21 August 2002
Resolution: CORRECTED
Fire Fighting › Structural - A Class Divisions
Issued 21 June 2002
Resolved
The galley aft port door does not properly close or seal. LEGACY COMPONENT DESC: Openings - Doors
Action required: 15 - Rectify deficiencies by next port
Resolved 21 August 2002
Resolution: CORRECTED
Fire Fighting › Semiportable Chemical-Foam Fire Extinguishers › Securing Means
Issued 21 June 2002
Resolved
The engineroom semi-portable fire extinguisher is not properly secured.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Fire Fighting › Ventilation Systems › Ducts
Issued 21 June 2002
Resolved
The exhaust vents in the engineroom are dirty and present a fire hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2002
Lifesaving › Inflatable Liferafts › Weak Link
Issued 21 June 2002
Resolved
The inflatable liferafts are not equipped with weak-links on their painter lines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2002
Lifesaving › Inflatable Liferafts
Issued 21 June 2002
Resolved
The removable chains for launching the port liferaft are not properly installed and cannot be removed easily for liferaft deployment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 21 June 2002
Resolved
The starboard lifeboat rudder is deteriorated and in need of replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 June 2002
Resolved
The port emergency embarkation light does not work.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 June 2002
Resolved
The starboard emergency embarkation light is deteriorated, improperly secured, and in need of repair or replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Electrical › Electrical Distribution System (service)
Issued 21 June 2002
Resolved
Electrical box covers throughout the vessel are missing covers. LEGACY COMPONENT DESC: Outlet Box
Action required: 15 - Rectify deficiencies by next port
Resolved 21 August 2002
Resolution: CORRECTED
Navigation › Emergency Steering
Issued 21 June 2002
Resolved
Post emergency steering instructions IAW 33CFR164.35
Action required: 15 - Rectify deficiencies by next port
Resolved 25 June 2002
Engineering › Steering Gear System
Issued 21 June 2002
Resolved
Numerous oil leaks in the steering compartment in way of the jockey bar and rudder connections need to be repaired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Operations/Management › Drills/Instruction › Abandon Ship
Issued 21 June 2002
Resolved
The crew must demonstrate proficiency in an abandon ship drill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 June 2002
Operations/Management › Drills/Instruction › Fire
Issued 21 June 2002
Resolved
The crew must demonstrate proficiency in a fire drill.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 June 2002
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 June 2002
Resolved
Provide proof that the vessel's oily water separator is 15ppm and approved for use in US waters.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 June 2002
Resolved
Holes in metal grating around emergency steering station are a tripping/safety hazard.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 21 June 2002
Resolved
Freon bottle in steering compartment is not properly secured.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2002
Pollution Prevention/Response › Prevention Equipment
Issued 21 June 2002
Resolved
Main deck fuel/oil containments do not have proper drain plugs. LEGACY COMPONENT DESC: Fixed Containment
Action required: 15 - Rectify deficiencies by next port
Resolved 21 August 2002
Resolution: CORRECTED
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 21 June 2002
Resolved
Oil leaks/drips in engineroom need to be wiped up.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 21 June 2002
Resolved
Oil containers in steering compartment are not properly secured/stowed.
Action required: 15 - Rectify deficiencies by next port
Resolved 23 June 2002
Engineering › Diesel Engine (auxiliary)
Issued 21 June 2002
Resolved
Generator fuel filters do not have metal flame impingement bowls or metal drain plugs.
Action required: 15 - Rectify deficiencies by next port
Resolved 21 August 2002
Resolution: CORRECTED
Pollution Prevention/Response › Prevention Equipment
Issued 21 June 2002
Resolved
Provide proof of certification for sewage treatment plant IAW 33CFR159. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 15 - Rectify deficiencies by next port
Resolved 21 August 2002
Resolution: CORRECTED
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 21 June 2002
Resolved
The port main deck shower does not properly drain.
Action required: 15 - Rectify deficiencies by next port
Resolved 25 June 2002
Construction/Loadline › Hull
Issued 21 June 2002
Resolved
Have cracks and wastage of bulwark flanges inspected by Flag State and provide US Coast Guard with a copy of the report at next US port call. LEGACY COMPONENT DESC: Bracket
Action required: 15 - Rectify deficiencies by next port
Resolved 31 October 2002
Resolution: Cleared after MSO Guam received satisfactory class report from CRS.
Accommodation/Occupational Safety › Occupational Safety
Issued 21 June 2002
Resolved
The piping insulation in the engineroom has been damaged and friable asbestos fibers exposed. Properly seal/remove all friable asbestos and have space certified safe for entry. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 15 - Rectify deficiencies by next port
Resolved 31 October 2002
Resolution: Cleared after MSO Guam received satisfactory industrial hygenist report.
Construction/Loadline
Issued 8 October 2001
Resolved
18 in x 2 inch epoxy hull repair & others made w/o knowledge of SOLAS Safety Construction Certificate Issuing Authority, NKK. Vsl to provide NKK w/full details regarding temporary hull repairs & institute appropriate corrective action.
Condition: Unknown
Due 19 October 2001
Resolved 19 October 2001
Documentation
Issued 30 April 2001
Resolved
Remove all outdated manuals and publications throughout the vessel IAW the ISM code.
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Fire Fighting
Issued 30 April 2001
Resolved
Provide adeguate washers for the International Shore Connection assembly. Solas 60 Chap. II/Reg. 56(h).
Condition: Unknown
Due 10 May 2001
Resolved 10 May 2001
Deck/Cargo
Issued 30 April 2001
Resolved
Properly ground metal sheathing armor for electrical cable supplied by #1 generator IAW Solas 60 Chap. II/Reg.27(a)(IV)(1)
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Electrical
Issued 30 April 2001
Resolved
Remove all unused "dead ends" electrical wiring and cables throughout engine room IAW Solas 60 Chap. II/Reg. 27
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Fire Fighting
Issued 30 April 2001
Resolved
Provide spanner wrenches for all fire hydrants throughout the vessel IAW Solas 60 Reg. 65(c).
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Fire Fighting
Issued 30 April 2001
Resolved
Provide "fire control plan" with the information and smybology required by Solas 74 Chap. II/-2/Reg. 20
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Navigation
Issued 30 April 2001
Resolved
VESSEL NEEDS TO PROVIDE THE FOLLOWING NAVIGATIONAL PUBS SAILING DIRECTIONS,TIDAL CURRENT TABLES, INTERNATIONAL RULES OF THE ROAD, AND INLAND RULES OF THE ROAD. SOLAS 74/78 V 20
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Construction/Loadline
Issued 30 April 2001
Resolved
REPAIR DOORS LEADING TO ENGINE ROOM SO THAT THEY PREVENT PASSAGE OF SMOKE AND FLAMES IAW SOLAS 60 REG. 38(d).
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Deck/Cargo
Issued 30 April 2001
Resolved
Install non-conductive matting on deck in the rear of main switch board IAWSolas 60 Chap. II/Reg. 27(1)(ii)
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Lifesaving
Issued 30 April 2001
Resolved
Arrange both bridge ring buoys/smoke light so that they are ready for quickrelease IAW Solas 74 Reg.7.1.3
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Lifesaving
Issued 30 April 2001
Resolved
Provide drain valve system for #1 lifeboat that automatically closes when boat is waterborn. Solas 74 Chap. III/Reg. 7.1
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Lifesaving
Issued 30 April 2001
Resolved
Provide liferaft launching instructions for the liferafts which are installed on the ship IAW Solas 74 Chap. III/Reg. 9
Condition: Unknown
Due 3 June 2001
Resolved 3 June 2001
Lifesaving
Issued 11 April 2000
Resolved
Prove proper operation of port and starboard lifeboat davit limit switches.SOLAS 60 III/29(l)
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 11 April 2000
Resolved
Install missing securing dog on watertight door, located aft superstructure, poop deck, outside galley. ICLL 1966, Annex I Reg 12
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 11 April 2000
Resolved
Make weathertight door located port side, poop deck operable. ICLL 1966, Article 15
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 11 April 2000
Resolved
Permanently repair discharge line from E/R bilge pump to #4 CTR slop tank. MARPOL 73/78 Annex I, Reg 4
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 11 April 2000
Resolved
Prove operation of all general alarm call boxes. SOLAS 74 amend I/11
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Fire Fighting
Issued 11 April 2000
Resolved
Update fire control plan to include all emergency equipment using standard IMO symbology. SOLAS 74 amend II/20
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Fire Fighting
Issued 11 April 2000
Resolved
Permanently repair exhaust pipe for emergency fire pump. SOLAS 74 amend I/11
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 11 April 2000
Resolved
Remove all paint from forecastle and properly stow in paint locker. SOLAS 74 amend I/11
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Fire Fighting
Issued 11 April 2000
Resolved
Ensure all required SCBA air bottles and spares are re-filled and serviceable. SOLAS 60 2/63
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 11 April 2000
Resolved
Correct loadline markings on ship's hull to correspond to current Loadline Certificate. ICLL 1966 Annex I, Reg 6
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 11 April 2000
Resolved
Repair/replace securing bracket for pnuematic motor on starboard lifeboat davit (motor is used for raising lifeboat). SOLAS 74 amend I/11
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Engineering
Issued 25 November 1999
Resolved
Hydro test oil transfer piping to 1 and 1/2 times Maximum Allowable WorkingPressure (& provide proof). 33 C.F.R. 156.170
Condition: Unknown
Due 29 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Renew all deteriorated and holed gaskets and properly adjust dogs on watertight doors entering the deckhouse, main deck port and starboard sidesas well as the forward and center watertight doors on the port and starboard sides entering the compressor room. ICLL 1966 Article 15
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanent repairs shall be completed to wasted #3 fuel oil tank top under the conveyor belt, in the conveyor tunnel near frames 90-95. ICLL 1966, Article 15
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanent repairs shall be completed to the hole in the bottom shell plating and tank top of #4 center ballast tank. This will require access be provided to all internal spaces of #4 center ballast tank. ICLL 1966, Article 15
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanently isolate ballast piping from #4 center bilge water holding tank.Install metallic piping from the tank to a pump, other than the ballast and/or fire pump, to enable the tank to be pumped ashore. MARPOL 73/78 Annex I/17
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanently repair to the satisfaction of class society wasted, holed, and fractured bulwark assemblies along the entire cargo deck, port and starboard sides. ICLL 1966, Article 15
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanently remove the drain piping and hoses installed between the compressor room and #4 port ballast tank to the satisfaction of class. ICLL 1966, Article 15
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Lifesaving
Issued 1 September 1999
Resolved
Permanently repair stbd aft gunwale on the stbd lifeboat to the satisfaction of class. SOLAS 60 III/2-5
Condition: Unknown
Due 1 October 1999
Resolved 17 September 1999
Engineering
Issued 1 September 1999
Resolved
In lieu of soft patched, permanently repair to the satisfaction of class the independent fuel tank located at the aft compressor house. SOLAS 74 I/11
Condition: Unknown
Due 1 October 1999
Resolved 17 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanently repair to the satisfaction of class society wasted, holed ventilation ducts and wasted, seized and missing ventilators for the compressor room, located on the top of the compressor room house.
Condition: Unknown
Due 13 September 1999
Resolved 17 September 1999
Electrical
Issued 1 September 1999
Resolved
Clean all fuel and oil residue from all electrical motors, controllers, distribution panels and cables in the engine room.
Condition: Unknown
Due 13 September 1999
Resolved 17 September 1999
Fire Fighting
Issued 1 September 1999
Resolved
Ensure all fire screen doors throughout vessel are in place and properly/completely close and latch.
Condition: Unknown
Due 13 September 1999
Resolved 17 September 1999
Unknown
Issued 1 September 1999
Resolved
Vessel failed to notify the Coast Guard of seven seperate oil discharge incidents.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Engineering
Issued 1 September 1999
Resolved
Renew the wasted and holed flame screen for the compressor room fuel tank.
Condition: Unknown
Due 13 September 1999
Resolved 17 September 1999
Engineering
Issued 1 September 1999
Resolved
Properly insulate turbochargers and exhaust piping on ship service generators and compressor drive engines.
Condition: Unknown
Due 13 September 1999
Resolved 17 September 1999
Engineering
Issued 1 September 1999
Resolved
All licensed engineers shall demonstrate proper operation of the Oily-waterseparator prior to departure from Guam. MARPOL 73/78, Reg. 16, STCW III/2
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanent repairs shall be completed to wasted and holed main deck between the engine room and main deck cabins, forward starboard side passageway. ICLL 1966, Article 15
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Unknown
Issued 1 September 1999
Resolved
The vessel has no installed discharge piping for the removal of oily waste from # 4 Center Bilge Holding Tank to a reception facility.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Permanently repair wasted and holed superstructure-to-deck connection port and stbd sides (at least 30 linear feet). ICLL 1966 Article 15
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
In lieu of soft patches, make permanent repairs to the satisfaction of class society all piping systems in the compressor room, silo room and engine room. ICLL 1966 Article 15
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Prior to entry into U.S. waters, the above listed deficiencies shall be corrected to the satisfaction of NKK class society. A written survey report from NKK class society shall be provided to MSO Guam for review and approval prior to entry into U.S. waters.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Clean #4 port and starboard ballast tanks and make suitable for carriage ofclean ballast. MARPOL 73/78 Annex I/14
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Documentation
Issued 1 September 1999
Resolved
The vessels Oil Record Book was not filled out or maintained properly.
Condition: Unknown
Due 7 October 1999
Resolved 7 October 1999
Engineering
Issued 1 September 1999
Resolved
The vessesl hoses and transfer pipeline were not tested to 1 1/2 times the MAWP.
Condition: Unknown
Due 30 November 1999
Resolved 1 December 1999
Unknown
Issued 1 September 1999
Resolved
Vessel discharged oily waste into the waters of the EEZ on 7 separate occasions.
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Unknown
Issued 1 September 1999
Resolved
Vessel could not provide required records for hose information or test records for hoses or pipeline.
Condition: Unknown
Due 29 November 1999
Resolved 29 November 1999
Documentation
Issued 1 September 1999
Resolved
The vessel crew were not complying with the transfer procedures and the transfer procedures were missing some required information.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
The vessel crew intentionally dumped approximately 18 gallons of Diesel Oilinto the bilge.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Engineering
Issued 1 September 1999
Resolved
The transfer hoses used to pump oily waste were not marked properly.
Condition: Unknown
Due 22 September 1999
Resolved 22 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Prove proper operation of the bilge pumping system, pumping water from eachbilge suction fitting located in the conveyor belt tunnel, port and starboard sides. ICLL 1966 Article 15
Condition: Unknown
Due 30 November 1999
Resolved 1 December 1999
Construction/Loadline
Issued 1 September 1999
Resolved
The engine room waste oil tank and #4 center/port/stbd ballast tanks shall be pumped ashore and cleaned. A class survey report indicating internal exam of each ballast tank must be provided to the [name withheld] to ballast tank manhole covers shall be approved by class. MARPOL73/78, Reg.17
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Engineering
Issued 1 September 1999
Resolved
#5 Starboard Fuel Oil Tank vent pipe is fractured and filled with cement. Class society shall survey entire tank and provide survey report attesting to the structural and watertight integrity of the tank. ICLL 1966, Article 20
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Lifesaving
Issued 1 September 1999
Resolved
Pump ashore and clean all oil and fuel from the engine room bilges. All open drums filled with oil and/or fuel shall be properly disposed ashore. 33CFR155.770
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Navigation
Issued 1 September 1999
Resolved
Vessel not manned in accordance with Safe Manning Certificate. SOLAS 1974,Reg. V/13
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Watertight door and adjacent through fitting on starboard main deck is wasted and in need of repair (water leaks into crew compartment). Make watertight to the satisfaction of class. ICLL 1966, Article 12
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Main deck wasted and holed, starboard side amidships. Make permanent repairs to the satisfaction of class. ICLL 1966, Article 15
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Construction/Loadline
Issued 1 September 1999
Resolved
Provide class survey report indicating vessel is in satisfactory condition for its intended route ad service. COTP Order 7-99
Condition: Unknown
Due 2 September 1999
Resolved 17 September 1999
Electrical
Issued 19 April 1999
Resolved
Enclose stepdown transformer attached to underside of reefer plant control panel. SOLAS 60 II-27.
Condition: Unknown
Due 19 May 1999
Resolved 23 April 1999
Deck/Cargo
Issued 19 April 1999
Resolved
Pad-eye, turnbuckle, and shackle boom mast guy stay are wasted. SOLAS 74 (amend) I/11.
Condition: Unknown
Due 19 May 1999
Resolved 23 April 1999
Engineering
Issued 19 April 1999
Resolved
Several fuel oil tank vent containments are holed.
Condition: Unknown
Due 19 May 1999
Resolved 23 April 1999
Engineering
Issued 19 April 1999
Resolved
Repair/replace flame screens for #3 port fuel oil tank vent. SOLAS 74 (amend) I/11.
Condition: Unknown
Due 6 June 1999
Resolved 6 June 1999
Lifesaving
Issued 2 April 1999
Resolved
MAKE THE AFT LIFEBUOYS LOCATED ON THE LIFEBOAT DECK ARE INACCESSIBLE DUE TOTHE STORAGE OF MOORING LINES AS REQUIRED BY SOLAS 60 III/21, CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Lifesaving
Issued 2 April 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Fire Fighting
Issued 2 April 1999
Resolved
UPDATE ALL COPIES OF THE VESSEL'S FIRE CONTROL PLAN TO INCLUDE THE INSTALLATION OF A NEW EMERGENCY FIRE PUMP AS REQUIRED BY SOLAS 74 AMENDED II-2/20, CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Documentation
Issued 2 April 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Navigation
Issued 2 April 1999
Resolved
EMERGENCY STEERING DRILLS NOT CONDUCTED QUARTERLY, AS REQUIRED BY SOLAS 74 AMENDED V/19-2, CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Lifesaving
Issued 2 April 1999
Resolved
OPERATION OF LIFEBOAT ENGINES NOT CONDUCTED WEEKLY AS REQUIRED BY SOLAS AMENDED III/19.6.2, CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 April 1999
Resolved 23 April 1999
Fire Fighting
Issued 18 May 1998
Resolved
Number 1 fire station hydrant valve nonfunctional,(forward most port side hydrant) repair as per SOLAS Chp II-2 reg 6.2.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
Fire hose in number 1 fire station is holed, replace as per, SOLAS Chp II-2reg 7.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Construction/Loadline
Issued 18 May 1998
Resolved
Emergency escape scuttle for aftr steering cannot be opened from the inside, and the escape ladder is missing, repair as per SOLAS Chp 1 reg 11,ILO-147
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Construction/Loadline
Issued 18 May 1998
Resolved
Bolts missing for man hole access covers, in forepeak, for water tanks and anchor chain locker, install fasteners as per SOLAS Chp 1 reg 11.
Condition: Unknown
Due 18 June 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
Fire hose nozzels missing from fire station #8 and #9, located in engine room, replace as per SOLAS Chp II-2 reg 8.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Navigation
Issued 18 May 1998
Resolved
Installed phone system between ships bridge and aft steering not functional, repair as per SOLAS Chp V reg 19-2(b)(iii).
Condition: Unknown
Due 18 June 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
Emergency fire pump does not provide adequate water pressure for fire fighting, repair as per SOLAS Chp II-2 reg 4.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Lifesaving
Issued 18 May 1998
Resolved
The fiberglass on the port lifeboat gunwale is cracked, in way of gripes are cracked, repair as per SOLAS 74 amended Chp III reg 19.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
Firemain valve, in way of Caterpillar room is frozen shut preventing firemain flow through the space, repair as per SOLAS 74 amended I/11, repair prior to entry into next U.S. port.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
Ventilation closures and dampers throughout the vessel are inoperable in muliple spaces, ccorrect as per SOLAS 74 amended I/11.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
Vent for paint locker cannot be shut thus allowing air flow in an event of fire in space, repair as per SOLAS 74 amended I/11.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
The fixed extinguishing system for the paint locker is set up for 2 10 lbs.extinguishers, there is only one installed, correct as per SOLAS 74 amendedI/11.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
The aft bulkhead of the paint locker is holed thus allowing the extinguishing agent to escape from the space when activated, correct as perSOLAS 74 amended I/11.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Fire Fighting
Issued 18 May 1998
Resolved
A portable fire extingusher is missing from station #22 in the caterpillar room, SOLAS 74 amended I/11, II-2/21.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Electrical
Issued 18 May 1998
Resolved
Globe guards and associated safety cage is missing on light fixtures in thepaint locker and caterpillar room, repair as per SOLAS 74 I/11, SOLAS 60 II/27.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Electrical
Issued 18 May 1998
Resolved
The lighting fixture in the laundry/shower room is missing a protective covering, SOLAS 74 amended I/11, SOLAS 60 II/27.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Navigation
Issued 18 May 1998
Resolved
The weld securing the upper rudder post housing to the deck are cracked. The impact of this discrepancy is undeterminable because the vessel has no manuals or plans on board, repair to the satisfaction of Flag Administration.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Navigation
Issued 18 May 1998
Resolved
The pin securing the hydraulic ram to the tiller assembly is missing a cotter pin, so as to prevent the loss of nut, preventing any steering casualties, repair as per SOLAS 74 amended I/11.
Condition: Unknown
Due 19 May 1998
Resolved 20 May 1998
Unknown
Issued 18 May 1998
Resolved
none
Condition: Unknown
Due 22 July 1998
Resolved 22 July 1998
Accommodation/Occupational Safety
Issued 18 May 1998
Resolved
No water pressure in hospital space to the sink or toilet, correct as per ILO-147.
Condition: Unknown
Due 19 May 1998
Resolved 22 July 1998
Lifesaving
Issued 14 October 1997
Resolved
Starboard davit span securing brackets excessively worn. Vessel is required to correct this non-adherence with SOLAS 60 III/36 prior to next U.S. port.
Condition: Unknown
Due 15 October 1997
Resolved 14 October 1997
Lifesaving
Issued 14 October 1997
Resolved
One half of total number of life buoys not equipped with efficient self- igniting lights. Vessel required to correct this non-adherence to SOLAS 60III/21(e) prior to next U.S. port.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Lifesaving
Issued 14 October 1997
Resolved
Starboard lifeboat cover severely wasted. Vessel required to correct this non-adherence with SOLAS 60 III/9 prior to next U.S. port.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Lifesaving
Issued 14 October 1997
Resolved
Starboard lifeboat rubber rubrail is not properly secured to lifeboat, i.e.screws holding the rubrail to the boat are not holding and rubrail is not affixed to the craft. Vessel is required to correct this non-adherence to SOLAS 60 III/4 prior to next U.S. port.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Lifesaving
Issued 14 October 1997
Resolved
Port lifeboat forward and aft lower fall block long links and rings for attaching to the slinghooks are excessively worn [Measured reduction fm 4.25 inch circumferance to 3.0 inch]. Vsl required to correct this non- adherence with SOLAS 60 III/36 prior to next U.S. port.
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Port and starboard lifeboat oar crutches were not attached to the lifeboatswith lanyard or chain. Vessel is required to correct this non-adherence to SOLAS 60 CH III/REG 11(a)(i).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboat has fracture on portside gunnel. Fracture approximately3 inches long. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 5(a).
Condition: Unknown
Due 30 October 1997
Resolved 30 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Oar blade damaged thereby reducing overall effectiveness. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(i).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard motor lifeboat not kept so as to be at all times ready for use inthat the wet exhaust system is severly deteriorated (holed) due to corrosion; the exhaust thru-hull fitting is damaged as to render it not fitfor service, and the engine headstart is broken.
Condition: Unknown
Due 12 September 1997
Resolved 21 September 1997
Lifesaving
Issued 3 September 1997
Resolved
Port and starboard lifeboats oil lamps were of such condition as to appear not operational. Vessel is required to correct this non-adherence to SOLAS60 CH III/Reg 11(a)(v).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Port lifeboat missing galvanized wire stays for mast. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(vi).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Construction/Loadline
Issued 3 September 1997
Resolved
Hole in bow and evidence of significant wastage of hull in bow area. Vessel required to correct this non-adherence to SOLAS 60 CH II/Reg 14/ICLL66.
Condition: Unknown
Due 12 September 1997
Resolved 21 September 1997
Lifesaving
Issued 3 September 1997
Resolved
Port lifeboat missing sail. Vessel is required to correct this non- adherence to SOLAS 60 CH III/Reg 11(a)(vi).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Cleat on the sail mast of port lifeboat needs reattaching. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(vi).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
As a result of severe corrosion the port lifeboat was missing the mast support bracket and one of two stay brackets. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(vi).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
No vegetable, fish, or animal oil is onboard port lifeboat. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg ii(a)(xvi).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
One waterproof electric torch suitable for signalling was extremely weak, thereby indicating a need to replace the batteries. There were no spare batteries onboard and no spare bulb onboard. Extra torch which was onboardwas not operational.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboat waterproof electric torch suitable for signalling was not operational, nor was there one spare set of batteries. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xviii).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboats quantity of vegetable, fish, or animal oil is less thanrequired gallon (or four and half liters). Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xi).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Port lifeboat was missing the jack-knife fitted with a tin opener and lanyard. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xx).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Port lifeboat manual pump is not operable due to missing suction and discharge hose. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xxiii).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboat manual pump is not operable due to torn diaphram. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xxiii).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Port and starboard lifeboats releasing hook mount bolt heads were severly wasted. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 5(a).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboat sea anchor straps deteriorated to the extent that the sea anchor is not deployable. Vessel is required to correct this non- adherence to SOLAS 60 CH III/Reg 11(a)(ix).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboats flares either expired or were observed soaking in waterfilled container thereby raising significant doubts as to said flares fitness for service. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xiv).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboats waterproof container to hold waterproof electric torch not waterproof. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xviii).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboats jack-knife fitted with a tin opener was corroded to thepoint as to render it not fit for service. Vessel is required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xx).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Starboard lifeboat was missing the approved cover of a highly visible colorcapable of protecting occupants from exposure. Vessel required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(xx).
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Deck/Cargo
Issued 3 September 1997
Resolved
Hole in hydraulic line in way of starboard side of NO. 1 hatch. Vessel is required to correct this non-adherence to SOLAS 60 CH II.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Lifesaving
Issued 3 September 1997
Resolved
Port and starboard lifeboats were missing a bailer and two buckets. Vesselis required to correct this non-adherence to SOLAS 60 CH III/Reg 11(a)(iii).
Condition: Unknown
Due 12 September 1997
Resolved 21 September 1997
Electrical
Issued 3 September 1997
Resolved
Ship's generator air breather ventilation pipe IWO of starboard lifeboat holed and severely wasted. Vessel is required to correct this non- adherence to SOLAS 60 CH II/Reg 27.
Condition: Unknown
Due 14 October 1997
Resolved 14 October 1997
Accommodation/Occupational Safety
Issued 25 April 1997
Resolved
Conducted a FOLLOW UP boarding of the vessel and found that the MSD onboardthe vessel was NOT operable and had not been operating in a long time. TheC.E. of the vessel stated that the vessel did not have any chemical for thetype two MSD. the vessel was using the type II MSD as a type III this is
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 25 April 1997
Resolved
While conducting the FOLLOW UP boarding of the vessel found that the lifeboat davits were missing the fore and aft penants for the proper lowering of the lifeboat. As required under SOLAS 60 Reg. 36(h). Vessel was given 30 days to repair.
Condition: Unknown
Due 8 May 1997
Resolved 11 May 1997
Engineering
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the emergency fuel shut offs for the vessels bunker valves were not properly ina condition to shutoff the fuel in an emergency. They would not operate orshut down the fuel vales. SOLAS 60 II Reg. 69(c).
Condition: Unknown
Due 25 April 1997
Resolved 11 May 1997
Construction/Loadline
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the vessel's watertight doors on the main deck port and starboard would not properly close as required under SOLAS 60 II/Reg. 15.
Condition: Unknown
Due 25 April 1997
Resolved 11 May 1997
Electrical
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the wiring of the vessel to be exposed and to be a danger of electrical shock._x001C_SOLAS 60II/Reg. 27 (a)(VI).
Condition: Unknown
Due 25 April 1997
Resolved 12 May 1997
Electrical
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the vessel's forward lighting fixtures were missing the required guards._x001C_ SOLAS 60 II/27(a)(2)(V).
Condition: Unknown
Due 25 April 1997
Resolved 12 May 1997
Lifesaving
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the vessel's lifeboat davit's sheaves were wasted and in need of repair/ replacement. SOLAS 60 III/Reg. 36(f).
Condition: Unknown
Due 25 April 1997
Resolved 12 May 1997
Accommodation/Occupational Safety
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the vessel's ladders on the vessels deck were severly wasted and in need of repair. ILLC.
Condition: Unknown
Due 25 April 1997
Resolved 12 May 1997
Construction/Loadline
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the vessel's cargo pump room flooring was severly wasted and in need of repair._x001C_ ILLC.
Condition: Unknown
Due 25 April 1997
Resolved 12 May 1997
Navigation
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the vessel's depth sounder recorder was inoperable. Vessel must have an operable depth sounder recorder as required under 33CFR164.35(i).
Condition: Unknown
Due 25 April 1997
Resolved 12 May 1997
Fire Fighting
Issued 18 April 1997
Resolved
WHILE CONDUCTING A BOARDING OF THE VESSEL FOUND THAT THE FIXED C02 SYSTEM ACTVATION SWITCH WAS DISASSEMBLED. SOLAS 60 II/ REG 66.
Condition: Unknown
Due 25 April 1997
Resolved 29 April 1997
Lifesaving
Issued 18 April 1997
Resolved
WHILE CONDUCTING A BOARDING OF THE VESSEL FOUND THAT THE CREW COULD NOT PERFORM PROPER FIRE AND ABANDON SHIP DRILLS. SOLAS 74 III/REG 18.
Condition: Unknown
Due 25 April 1997
Resolved 29 April 1997
Fire Fighting
Issued 18 April 1997
Resolved
While conducting a FOLLOW UP boarding of the vessel it was found that the vessel did not have proper fire fighting outfits, outfits were missing axes, lights, face plates improper, one missing a jacket, and missing tag lines. SOLAS 60 II reg. 63.
Condition: Unknown
Due 25 April 1997
Resolved 11 May 1997
Unknown
Issued 22 December 1996
Resolved
Light fixtures did not have covers/guards as required by SOLAS 60 II- 27(a)(5).
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Unknown
Issued 22 December 1996
Resolved
Electrical wiring unsupported and exposed. SOLAS 60 II/27 (a) (vi)
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Unknown
Issued 22 December 1996
Resolved
Water tight doors were in operable. SOLAS 60 II/15 (a)(i)
Condition: Unknown
Due 30 June 1997
Resolved 30 June 1997
Unknown
Issued 22 December 1996
Resolved
Lifeboat davits were rusted through in several locations and in need of repair. SOLAS 60 V/36 (f)
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Unknown
Issued 22 December 1996
Resolved
FWD machinery space had an excess of fuel on the deck.
Condition: Unknown
Due 15 May 1997
Resolved 15 May 1997
Unknown
Issued 22 December 1996
Resolved
Life rings were not accessible as required by SOLAS 60 III/21 (h).
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Unknown
Issued 22 December 1996
Resolved
Steering room did not have non-slip surface or grating on the deck as required by SOLAS 74 Amended II-1 29-13.2
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Unknown
Issued 22 December 1996
Resolved
Ventilation in foward paintlocker did not have closure capabilities as required by SOLAS 60 II/69 (a).
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Unknown
Issued 22 December 1996
Resolved
Radar is not operable on 9 GHZ range as required by SOLAS 74 Amended V/12 (g).
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Accommodation/Occupational Safety
Issued 22 December 1996
Resolved
Vessel was equipped with a type 2 MSD that was inoperable. The chief engineer stated that it had not been working for approximately one month.
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Unknown
Issued 22 December 1996
Resolved
Fire control plan was not posted in an accessible position as required by SOLAS 60 II/70.
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Unknown
Issued 22 December 1996
Resolved
CO2 system was inoperable.
Condition: Unknown
Due 26 December 1996
Resolved 27 January 1997
Unknown
Issued 22 December 1996
Resolved
No non-conducting mats at the swithcboards as required by SOLAS 60 II/27 (a)(ii).
Condition: Unknown
Due 11 February 1997
Resolved 11 February 1997
Navigation
Issued 9 April 1996
Resolved
Continuous recorder for echo depth sounder was inoperable.
Condition: Unknown
Due 11 July 1996
Resolved 11 July 1996
Documentation
Issued 20 March 1994
Resolved
The vessel's Oil Record Book has not been maintained for three years as required.
Condition: Unknown
Due 1 February 1995
Resolved 12 April 1994
Documentation
Issued 20 March 1994
Resolved
The vessel's oil transfer procedures were incomplete(e.g. the procedures concering emergency shutdown and communications, the procedures for emptying manifold containment, the cargo information required for each cargo transferred)
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Accommodation/Occupational Safety
Issued 20 March 1994
Resolved
The vessel's marine sanitation device was missing the required label. The marine sanitation device was described as a type II device.
Condition: Unknown
Due 12 April 1994
Resolved 12 April 1994
Navigation
Issued 14 April 1992
Resolved
COAST PILOT NAVIGATION PUBLICATION WAS NOT UP TO DATE.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Documentation
Issued 14 April 1992
Resolved
VESSEL HAD NO OIL RECORD BOOK.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Navigation
Issued 14 April 1992
Resolved
VESSEL HAD NO TIDE TABLES NAVIGATION PUBLICATION ON BOARD.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Accommodation/Occupational Safety
Issued 14 April 1992
Resolved
VESSEL HAD NO MARPOL V WASTE MANAGEMENT PLAN ON BOARD. CG FURNISHED A COPY.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Accommodation/Occupational Safety
Issued 14 April 1992
Resolved
VESSEL DID NOT HAVE A MARPOL V PLACARD ON BOARD. CG FURNISHED A COPY.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Documentation
Issued 14 April 1992
Resolved
THE VESSEL DID NOT HAVE OIL TRANSFER PROCEDURES ON BOARD. CG FURNISHED A SAMPLE COPY FOR THE VESSEL.
Condition: Unknown
Due 21 April 1992
Resolved 21 April 1992
Navigation
Issued 14 April 1992
Resolved
LIGHT LIST NAVIGATION PUBLICATION WAS NOT UP TO DATE.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Lifesaving
Issued 16 September 1987
Resolved
IN INTERIOR SHELL PORT LIFEBOAT, PORT SIDE: REPAIR DRY ROTTER AREA (6X12")FORWARD OF PROVISIONS LOCKER.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
EFFECT PERMANENT REPAIRS TO FRAMING NOTED IN ITEM D1.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
EFFECT PERMANENT REPAIRS IN AREA FROM FOOT OF STEM TO APPROXIMATELY 9" ABOVE THE FOOT. AREA TO BE REPAIRED SHOWS EVIDENCE OF DRY ROT.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
IN AREA IMMEDIATELY UNDER AFTER CHOCK GUARD, ON KEEL, EFFECT PERMANENT REPAIRS TO DRY ROT (PORT LIFEBOAT).
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
IN AREA OF STERN (PORT AND STARBOARD) OF PORT LIFEBOAT EFFECT PERMANENT REPAIRS AT GARBOARD STRAKE WHERE DRY ROTTED (APPROXIMATELY 3 FEET).
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
REPLACE RUDDER POST MOUNT (UPPER), PORT LIFEBOAT.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
AS A TEMPORARY REPAIR, SISTER FRAMES 13, 14, 15 (AS NUMBERED FROM STERN) STARBOARD SIDE OF PORT LIFEBOAT, BETWEEN KEEL AND FIRST LONGITUDINAL.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
CROP/RENEW/REPLACE FORWARD AND AFTER RELEASE HOOK BASE PLATES PORT LIFEBOAT
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
PROPERLY REINSTALL ALL BUOYANCY TANKS AND PROVISIONS PORT LIFEBOAT.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Lifesaving
Issued 16 September 1987
Resolved
CROP/RENEW/REPLACE FORWARD BASE PLATE FOR RELEASING HOOK, STARBOARD LIFE- BOAT.
Condition: Unknown
Due 16 September 1987
Resolved 16 September 1987
Navigation
Issued 24 February 1987
Resolved
33CFR164.33,33USC1232,$25000. BOARDING OBSERVED THE LIGHT LIST FOR THE VSL WAS A 1980 WITH NO CORRECTIONS.
Condition: Unknown
Due 24 February 1987
Resolved 24 February 1987
Unknown
Issued 24 February 1987
Resolved
33CFR159.7,33USC1322(J),$2000. BOARDING OFFICER WAS INFORMED BY THE MASTER THAT THERE WAS NO MARINE SANITATION DEVICE ON BOARD THE VESSEL.
Condition: Unknown
Due 24 February 1987
Resolved 24 February 1987
Navigation
Issued 24 February 1987
Resolved
33CFR164.33,33USC1232,$25000. BOARDING OFFICER OBSERVERED THE CHARTS OF THEAREA TO BE TRANSITTED WERE 1985 WITH NO CORRECTIONS.
Condition: Unknown
Due 24 February 1987
Resolved 24 February 1987
Unknown
Issued 24 February 1987
Resolved
33CFR151.25(H),33USC1321(J)(2),$25000. BOARDING OFFICER BOARDED THE VESSEL AND WAS ADVISED BY THE MASTER THAT THE OIL RECORD BOOK HAD NOT BEEN SIGNED.
Condition: Unknown
Due 24 February 1987
Resolved 24 February 1987
Navigation
Issued 31 October 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Navigation
Issued 31 October 1986
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Navigation
Issued 31 October 1986
Resolved
33CFR164.33(A)(3)(II) THE VESSEL DID NOT HAVE CURRENT TIDAL CURRENT TABLES.THEY HAD A 1983 EDITION.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Navigation
Issued 31 October 1986
Resolved
33CFR164.33(A)(2)(II) THE VESSEL DID NOT HAVE A CURRENTLY CORRECTED LIGHT LIST. THEY HAD A 1979 LIGHT LIST WITH NO UPDATES ENTERED.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Navigation
Issued 31 October 1986
Resolved
33CFR164.33(A)(3)(I) THE VESSEL DID NOT HAVE CURRENT TIDE TABLES. THEY HAD A 1983 EDITION.
Condition: Unknown
Due 31 October 1986
Resolved 31 October 1986
Navigation
Issued 2 October 1986
Resolved
33CFR164.11(Q) THE TESTS REQUIRED BY 33CFR164.25 WERE MADE BUT WERE NOT LOGGED.
Condition: Unknown
Due 31 October 1986
Resolved 2 October 1986
Navigation
Issued 2 October 1986
Resolved
33CFR164.41 THE VESSEL DID NOT HAVE ANY ELECTRONIC POSITION FIXING DEVICES ON BOARD.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Documentation
Issued 2 October 1986
Resolved
33CFR151.19(B) VESSEL'S IOPP CERTIFICATE WAS EXPIRED.
Condition: Unknown
Due 31 October 1986
Resolved 2 October 1986