MAURY USCG vessel records Sign in
← All vessels

FLAG ADRIENNE

FLAG ADRIENNE is a 1968 freight ship. The Coast Guard has recorded 111 inspections since 1987, most recently in September 2007, along with 118 deficiencies — 1 with no resolution recorded — and 9 operational controls.

Records from 1987 to 2007. Most recent: inspection, 17 September 2007.

Built
1968
Last inspected
17 September 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6820907 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
223277
Flag
GREECE
—
Maury page id
psix-223277

Inspections, by type

…with no type recorded78
Years with a record 20 calendar years (1987–2007)
The 111 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it17970 - Dead Weight, Metric Ton
11855 - Regulatory (Subpart C or D), Gross Ton
11855 - Convention (Subpart B), Gross Ton
7172 - Regulatory (Subpart C or D), Net Ton
7172 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 111

17 September 2007 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3059515
30 May 2007 Type not recorded
No type recorded · Station Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2947057
30 May 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2947075
19 April 2007 MARPOL Annex V Examination · ILO-147 Exam · ISPS III Exam · NPV Safety Exam · MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2910684
18 April 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2911556
15 February 2007 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 2872980
27 January 2007 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2861467
9 January 2007 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2852678
23 May 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2656907
10 April 2006 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2621081
19 March 2006 PII Safety Exam · ISPS III Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2605800
17 March 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2604243
2 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2594609
29 November 2005 Random ISPS/MTSA/PSC · NPV Safety Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2542486
1 September 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2480817
25 June 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2402280
9 May 2005 Random ISPS/MTSA/PSC · ISPS III Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2353143
27 April 2005 Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2343984
19 April 2005 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2338153
17 March 2005 PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2310378
8 November 2004 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2237521
21 October 2004 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2233772
24 August 2004 PII Safety Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2175125
24 August 2004 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2176035
28 July 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2148479
8 July 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2126168
6 July 2004 PII Safety Exam
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2123578
3 July 2004 ISPS II Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2116601
28 May 2004 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2080959
3 May 2004 Security Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2058284
16 April 2004 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2045085
23 March 2004 MARPOL Annex I Examination · MARPOL Annex V Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2029540
3 February 2004 Administrative Inspection
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1999384
11 December 2003 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1962601
24 November 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1953587
1 November 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1946481
28 October 2003 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1937590
9 September 2003 Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1900720
9 September 2003 Damage Survey
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1905419
7 August 2003 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1869095
5 August 2003 Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1867353
20 June 2003 Administrative Inspection
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1822215
25 April 2002 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1609369
11 March 2002 Type not recorded
No type recorded · GROUP BOSTON · USCG Northeast District (CGD-NE) · Activity 1607559
17 January 2002 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1479736
12 December 2001 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 296108
19 July 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291915
11 June 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 24543
9 April 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 288875
25 January 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 285853
4 October 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 282841
14 March 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 275781
27 January 2000 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 273544
30 December 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 23666
6 October 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 64317
24 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 432132
22 July 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 430902
9 March 1999 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 426247
18 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425997
11 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 175115
11 May 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 415594
22 April 1998 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 414763
24 March 1998 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 413934
10 March 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 720231
4 March 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 413338
13 January 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 411674
11 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 207483
11 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 765329
22 May 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 720230
19 May 1997 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 118946
19 March 1997 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 401585
1 December 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 397890
22 October 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 396673
6 October 1996 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 396693
19 September 1996 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 395399
10 March 1996 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 388851
9 March 1996 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 753373
8 March 1996 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 193360
1 December 1995 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 385243
14 January 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 374304
13 December 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 373166
24 September 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 370877
5 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 370202
5 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1179318
17 August 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 99532
4 June 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 53703
8 April 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 116094
19 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 365301
1 February 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 364181
31 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 150490
31 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 646731
12 January 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 5118
29 October 1993 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 361976
17 August 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 360211
29 January 1991 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 460844
8 August 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 338661
9 July 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 338133
3 April 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 336264
3 April 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 336371
15 March 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 338141
29 August 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 514788
13 May 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 330343
3 April 1989 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 329439
30 March 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 329430
8 March 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 509300
28 December 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 327655
8 December 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 327279
13 July 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 324493
23 May 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 323695
11 May 1988 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 492284
21 May 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 316268

Deficiency record · 118

Fire Fighting › Fire Main › Condition
Issued 17 September 2007 No resolution recorded
Vessel fire main has several soft patches located just above #2 fire pump. Renew/Replace section of fire main as necessary to the satisfaction of the attending classification surveryor
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Drills/Instruction › Fire
Issued 19 March 2006 Resolved
CREW FAILED TO RESPOND TO FIRE DRILL PROPERLY EQUIPPED AND WITH ADEQUATE PERSONNEL.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2006
Resolved 21 March 2006
Resolution: PERFORMED SATISFACTORY FIRE DRILL.
Deck/Cargo › Mooring/Anchoring › Brake
Issued 19 March 2006 Resolved
WHILE TRANSITTING INTO THE PORT OF TAMPA, FL VESSEL'S ANCHOR GAVE WAY AND DRAGGED THE BOTTOM. VESSEL WAS FORCED TO STOP WAY SWING AROUND AND HEAD OUT BOUND. ONCE SITUATION WAS UNDER CONTROL VESSEL PROCEEDED INBOUND. VESSEL MUST HAVE CLASS ATTEST TO ANCHOR WINDLASS, ANCHOR BRAKE AND ANCHOR STOP IS OPERATING PROPERLY. ADDITIONALALY, ANCHOR STOP RECIEVED FULL WEIGHT OF VESSEL.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 March 2006
Resolved 10 April 2006
Resolution: Sector Charleston received Classification Survey for deficiency.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 29 November 2005 Resolved
Vessel's Safety Radio Certificate is to expire 03 Dec 2005 prior to sailing.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2005
Resolved 5 December 2005
Resolution: DNV issued vessel new Safety Radio Cert.
Communications › Radio Communications › Emergency Source of Power
Issued 29 November 2005 Resolved
02 of the vessel's emergency batteries for lighting and communications were inop
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2005
Resolved 5 December 2005
Resolution: New batteries were installed.
Communications › Radio Communications › Satellite Communications Capability
Issued 29 November 2005 Resolved
Vessel NAVTEX system was inop.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2005
Resolved 5 December 2005
Resolution: Technician attended vessel and installed a new NAVTEX reciever.
Lifesaving › Launching Appliances › Davit
Issued 29 November 2005 Resolved
03 guy pulleys for falls on Port side lifeboat davit were frozen due to lack of maintenance.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2005
Resolved 5 December 2005
Resolution: Vessel''s crew clean up and greased pulleys and proved proper operation.
Lifesaving › Lifeboat › Hull
Issued 29 November 2005 Resolved
Hull tie-in plate for bow pelican hook is rusted through and crack, compromising the structural integrity of the davit support system making the lifeboat inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2005
Resolved 5 December 2005
Resolution: Class and flag state approved in carriage of two additional 25 person liferafts (1 each side) in lieu of lifeboat until lifeboat can be repaired.
Stability › Watertight Integrity › General
Issued 29 November 2005 Resolved
Watertight hatch leading into emergency generator flat could not be made to close watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 December 2005
Resolved 5 December 2005
Resolution: Gasket was replaced and hinges adjusted so that hatch would seal properly.
Lifesaving › Visual Distress Signals (General) › Storage
Issued 29 November 2005 Resolved
Storage for distress flares not properly marked.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2006
Resolution: marked
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 29 November 2005 Resolved
Vessel to properly mark manuevering fact sheet.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2006
Resolution: marked
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2005 Resolved
Provide shatter guards for all exposed light fixtures in hospital space and crew accommodations
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2006
Resolution: guarded
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 29 November 2005 Resolved
Prove proper operation of hospital head light.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2006
Resolution: works
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 November 2005 Resolved
Replace all expired medication.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2006
Resolution: new
Engineering › Steering Gear System › Solenoid Valve
Issued 29 November 2005 Resolved
Vessel's main steering gear was unable to place the rudder at 35 degrees port or stbd. due to a miscalibrated solenoid valve.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 March 2006
Resolution: recieived class report
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 1 September 2005 Resolved
NOA not submitted in compliance with 33CFR160 subpart C. Vessel was denied entry until it could be properly screened.
Action required: 15 - Rectify deficiencies by next port
Resolved 30 September 2005
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 17 March 2005 Resolved
Sliding door to galley does not seal properly (Class A Fire Boundry).
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 22 April 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 17 March 2005 Resolved
Fire extinguishers in dry stores & windlass pump room expired & wasted.
Due 17 March 2005
Resolved 17 March 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 17 March 2005 Resolved
Light covers missing throughout vessel.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 22 April 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 March 2005 Resolved
Smoke detectors covers missing throughout vessel.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 22 April 2005
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 17 March 2005 Resolved
Exposed wiring on Bridge & Electrician's Shop.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 22 April 2005
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 March 2005 Resolved
Update Fire Control Plan to include chemical room.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 22 April 2005
Electrical › Electric Supply System (service) › Cable
Issued 24 August 2004 Resolved
Found open and deadend wiring in forward pumproom
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 21 October 2004
Resolution: OPEN WIRE HAS BEEN COVERED BY ELECTRICAL BOXES. THERE IS NOW NO EXPOSED WIRING.
Lifesaving › Lifefloat › Serviceable
Issued 24 August 2004 Resolved
Found cracked and worn liferings on second deck both port and strb, and (1) on foc'sle.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 24 August 2004
Resolution: Received faxed document ifrom Nils Gjesteby (agent) that rations and life rings have been replaced.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 24 August 2004 Resolved
Found (13) airborne food ration packages when inspecting lifeboats A total of twenty-five rations need to be placed in each lifeboat.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2004
Resolved 24 August 2004
Resolution: Received faxed document from agent that rations and life rings have been replaced.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 24 August 2004 Resolved
Containment boom became entangled when Master was preparing to test propulsion gear prior to departure.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 August 2004
Resolved 24 August 2004
Resolution: Received faxed report from [name withheld], Agent operations, that containment boom has been removed with no damage to running gear, note report summary.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 24 August 2004 Resolved
Starboard side, spare anchor is mounted crown down with shank placed in upward position mounted to inward gunnel. Top bracket is fractured at the weld joint. Also noted that fluke brackets were also fractured.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 September 2004
Resolved 21 October 2004
Resolution: THE WELD JOINTS HAVE BEEN SATISFACTORILY REPAIRED.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 July 2004 Resolved
Provide class attestation to proper repairs to secondary independent radar.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 July 2004
Resolved 28 July 2004
Lifesaving › Lifeboat Equipment › Food Ration
Issued 6 July 2004 Resolved
Emergency rations not in sufficient quantity. Vessel to aquire additional 13 rations.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 28 July 2004
Resolved 28 July 2004
Lifesaving › Lifeboat › Markings
Issued 6 July 2004 Resolved
Replace or renew retro tape on lifeboats.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 July 2004
Resolved 28 July 2004
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 6 July 2004 Resolved
CO2 Extinguisher #47 in Engine Room in Poor Condition/ Not Available for imediate use due to cracked hose.
Condition: Improper/Lack of Maintenance
Due 27 July 2004
Resolved 28 July 2004
Documentation › Safety/Response Plans/Programs
Issued 16 April 2004 Resolved
FCP DID NOT HAVE "B" CLASS BULKHEADS IDENTIFIED. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 May 2004
Resolution: ATTENDING OCMI VERIFIED "B" AND "A CLASS BLKHDS PROPERLY LABELED ON F.C.P.
Documentation › Safety/Response Plans/Programs
Issued 23 March 2004 Resolved
Update Fire Control Plan to reflect locations of class "b" bulkheads to the satisfaction of the Class Society. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Due 19 April 2004
Resolved 28 May 2004
Resolution: ATTENDING OCMI VERIFIED LOCATIONS OF "B" CLASS AND "A" CLASS BLKHDS
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 November 2003 Resolved
Cargo hose handling mast to be approved by flag administration for service intended. Every time crane is moved and reinstalled a new class attestation is required.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 December 2003
Resolution: Vessel provided class attestation to the condition of the temporary cargo handling davit.
Lifesaving › Lifeboat
Issued 28 October 2003 Resolved
Repair gunwale fracture forward and shell gelcoat fracture in way of davit block port life boat. Repair to satisfaction of class, within 30 days or prior to return to the U.S., whichever is first. LEGACY COMPONENT DESC: Hull
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 November 2003
Resolved 25 November 2003
Resolution: DNV Class survey report completed and provided to USCG reporting that fracture and gelcoat have been repaired and fwd/aft blocks have been modified for improved support of lifeboat.
Lifesaving › Lifeboat
Issued 28 October 2003 Resolved
Obtain class approval for repairs carried out on starboard lifeboat. (MSO Boston Item #1 of 09 September 2003). To satisfaction of class, within 30 days or prior to return to the U.S., whichever is first. LEGACY COMPONENT DESC: Hull
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2003
Resolved 25 November 2003
Resolution: Repair of cracks were surveyed and found in order by vessel''s class society, DNV.
Construction/Loadline › Structures
Issued 28 October 2003 Resolved
Address wastage to main deck in way of crane pedestal base. Deck recently covered in concrete. Remove concrete or inspect / UTthickness gauge from underside. (Boston Item #3 of 09 September 2003). To satisfaction of classification society, prior to using crane or within 30 days, whichever is first. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2003
Resolved 25 November 2003
Resolution: DNV conducted class survey and reports that the concrete cover inside the crane pedestal has been removed and new brackets have been fitted. UTM carried out of deck plating inside pedestal. Readings verified and found in order.
Construction/Loadline › Structures
Issued 28 October 2003 Resolved
Refasten/support 440 volt electrical panel supported by plastic ties in base of crane. Wiring pigtailed prevents closure of additional junction box, same location. (Boston Item #3 of 09 September 2003). Repair prior to using crane, prior to return to the U.S., or within 30 days, whichever is first.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 November 2003
Resolved 25 November 2003
Resolution: Vessel''s class society, DNV, conducted a class survey and reports that electrical cables and panels in the base of the crane are now in order.
Deck/Cargo › Cargo Transfer (solid)
Issued 28 October 2003 Resolved
Cargo hose-handling mast to be approved by flag administration for service intended, and to satisfaction of each OCMI on current voyage. Temp mast designed & fabricated by ship's crew. No test of safe working load carried out. Mast must be relocated dependent on berth arrangements. LEGACY COMPONENT DESC: Carge hose-handling mast
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 November 2003
Resolution: Examined and found sat. cargo hose handling davit. Master provided a copy of DNV survey report authorizing a SWL of 0.5 metric tons based on the load test to 1.0 metric tons.
Lifesaving › Lifeboat
Issued 9 September 2003 Resolved
The Stbd lifeboats stbd gunwale had several cracks that extend through the fiberglass and need to be repaired. Cause appears to have been excessive cable/line tension while the boat was cradled (crew speculation on cause) LEGACY COMPONENT DESC: Hull
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Resolution: Deficiency re-issued by MSO Providence.
Deck/Cargo › Cargo Transfer (solid)
Issued 9 September 2003 Resolved
A crane failed, falling on the port side section of cargo transfer piping, cracking the pipe. LEGACY COMPONENT DESC: piping
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Resolution: Piping replaced by vessel crew.
Construction/Loadline › Structures
Issued 9 September 2003 Resolved
Main deck inside base of the pedestal crane was excessively wasted - having 1-1.5 inches of scale rust and an unknown amount of wastage underneath. supports for the electrical distribution panel were wasted through - zip ties kept unit upright. A vertical stiffener had a section cut out as well. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Resolution: Deficiency re-issued by MSO Providence.
Deck/Cargo › Cargo Transfer (solid)
Issued 9 September 2003 Resolved
The topping lift cable for a deck crane parted in mid-span, resulting in the crane arm falling to the deck, injuring a crewman and damaging a cargo line. Crane arm was destroyed beyond repair. LEGACY COMPONENT DESC: deck crane
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Resolution: Deficiency re-issued by MSO Providence.
Documentation › Safety Management System
Issued 9 September 2003 Resolved
Safety policy missing: Maintenance and Inspection program for existing deck crane does not exist. No maintenance records (outside of one test) are maintained on the vessel. No cargo book for crane maintained. All operating procedures for crane are verbal. LEGACY COMPONENT DESC: Safety/Environmental Protection Policy
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Resolution: Deficiency re-issued by MSO Providence.
Operations/Management › Equipment Service/Testing
Issued 9 September 2003 Resolved
Maintenance and Inspection program for existing deck crane does not exist. No maintenance records (outside of one test) are maintained on the vessel. No cargo book for crane maintained. All operating procedures for crane are verbal.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 October 2003
Resolution: Deficiency re-issued by MSO Providence.
Electrical › Lighting (service)
Issued 7 August 2003 Resolved
LIGHT FIXTURE AT BOTTOM OF LOWER LEVEL ENGINGE ROOM LADDER HANGING LOOSE. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Resolution: Deficiency cleared
Electrical › Electric Supply System (service)
Issued 7 August 2003 Resolved
BATTERY CHARGER IS MISSING SIDE PANEL. LEGACY COMPONENT DESC: Battery Charger
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Construction/Loadline › Penetrations
Issued 7 August 2003 Resolved
WINDOW IS SHATTERED IN SPARE C ABIN # 120. LEGACY COMPONENT DESC: SHATTERED WINDOW
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Resolution: WITTNESSED INSTALLATION OF NEW WINDOW.
Lifesaving › Lifeboat Equipment
Issued 7 August 2003 Resolved
EQUIPMENT IN STARBOARD LIFE BOAT WAS WATER LOGGED.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2003
Lifesaving › Lifeboat Equipment
Issued 7 August 2003 Resolved
VACCUM SEAL IN FOOD RATION PACKAGE BROKEN, RATIONS WERE WATER LOGGED. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2003
Lifesaving › Lifeboat
Issued 7 August 2003 Resolved
REPLACE LIFELINE ON STARBOARD BOAT. LEGACY COMPONENT DESC: LIFELINE
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Fire Fighting › Ventilation Systems
Issued 7 August 2003 Resolved
4 FIRE DAMPERS ON BRIDGE NOT LABELED. LEGACY COMPONENT DESC: Ducts
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Deck/Cargo › Mooring/Anchoring
Issued 7 August 2003 Resolved
HINGE PIN ON BRAKE IS DISLODGED, STARBOARD MOORING WINCH. LEGACY COMPONENT DESC: Winch
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Lifesaving › Inflatable Liferafts
Issued 7 August 2003 Resolved
SPARE RAFT IS STORED UNDER FWD LADDER TO FOCSLE'. SEA PAINTER NOT ATTACHED TO WEAK LINK OR HYHDROSATIC RELEASE. ALSO NEEDS PELICAN HOOK FOR MANUAL RELEASE. LEGACY COMPONENT DESC: STOWAGE
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2003
Electrical › Electric Supply System (service)
Issued 7 August 2003 Resolved
MISSING COVER ON J- BOX IN PUMP ROOM ON DECK. LEGACY COMPONENT DESC: J-BOX COVER
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Construction/Loadline › Penetrations › Gasket
Issued 6 August 2003 Resolved
MISSING GASKET MATERIAL IN AFT WINDOW OF CREW'S MESS.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 August 2003
Resolution: WITTNESSED INSTALLATION OF NEW GASKET MATERIAL.
Fire Fighting › Emergency Fire Pumps
Issued 6 August 2003 Resolved
EXCESSIVE WATER LEAKING FROM DISCHARGE SIDE OF EMERGENCY FIRE PUMP. PUMP STILL SUPPLIED ADEQUATE WATER. LEGACY COMPONENT DESC: LEAKAGE
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 September 2003
Resolved 6 August 2003
Lifesaving › Lifebuoys
Issued 6 August 2003 Resolved
PEDANTS FOR SMOKE SIGNALS ON BRIDGE HAVE UV DAMAGE. LEGACY COMPONENT DESC: Self-Activitating Smoke Signals
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2003
Documentation
Issued 19 July 2001 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 July 2001
Resolved 1 August 2001
Engineering
Issued 19 July 2001 Resolved
No. 2 & 3 generators cooling water overboard pipe has fiberglass patch. Repair permanently to satisfactionof class.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Engineering
Issued 19 July 2001 Resolved
Emergency generator remote fuel shut off cable frozen and does not activatevalve. Prove proper operation by next U.S. port.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 19 July 2001 Resolved
All embarkation rope ladders in poor condition. Repair or replace by 01 Aug 01.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Lifesaving
Issued 19 July 2001 Resolved
Lifebuoy on stbd side poop deck light housing is cracked.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Engineering
Issued 19 July 2001 Resolved
M/E outboard S/W cooling pump outlet pipe has temporary patch. Repair permanently to satisfaction of class.
Condition: Unknown
Due 7 August 2001
Resolved 7 August 2001
Construction/Loadline
Issued 9 April 2001 Resolved
PROVIDE CLASS REPORT ON WASTAGE ON ALL SEA CHESTS.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Construction/Loadline
Issued 9 April 2001 Resolved
PROVIDE CLASS REPORT ON CONDITION OF AUX PIPING IN BILGE AREA, ENGINEROOM.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Lifesaving
Issued 9 April 2001 Resolved
REPLACE MOORING LINES.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Accommodation/Occupational Safety
Issued 9 April 2001 Resolved
PROVIDE BRACKETS FOR ALL O2 AND A2 TANKS.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Fire Fighting
Issued 9 April 2001 Resolved
MAKE REPAIRS TO LEAKS IN FIREMAIN.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Accommodation/Occupational Safety
Issued 9 April 2001 Resolved
RENEW ALL SAFETY RAILINGS.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Lifesaving
Issued 9 April 2001 Resolved
MAKE REPAIRS TO LIFEBOAT DAVIT FOUNDATIONS.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Construction/Loadline
Issued 9 April 2001 Resolved
MAKE REPAIRS TO ANCHOR/MOORING WINCH APPARATUS FOUNDATIONS.
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Fire Fighting
Issued 9 April 2001 Resolved
MOUNT #14 PORTABLE FIRE EXTINGUISHER IN BRACKET
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Construction/Loadline
Issued 9 April 2001 Resolved
PROVIDE CLASS REPORT ON INSET LOCATED PORT SIDE AFT.
Condition: Unknown
Due 6 June 2001
Resolved 6 June 2001
Fire Fighting
Issued 9 April 2001 Resolved
REMOVE ALL WIRES/ ROPES HOLDING OPEN DOORS AND EMERGENCY ESCAPES
Condition: Unknown
Due 17 May 2001
Resolved 17 May 2001
Navigation
Issued 4 October 2000 Resolved
ECHO DEPTH SOUNDER AND RECORDER INOP. [33 C.F.R. 164.35(i) & (h)].
Condition: Unknown
Due 5 February 2001
Resolved 5 February 2001
Fire Fighting
Issued 14 March 2000 Resolved
HAVE ALL SCBA BOTTELS AND APPARATUS SERVICED.
Condition: Unknown
Due 14 March 2000
Resolved 20 March 2000
Fire Fighting
Issued 14 March 2000 Resolved
DEMOOSTRATE PRPPER FIRE DRILL
Condition: Unknown
Due 14 March 2000
Resolved 20 March 2000
Navigation
Issued 27 January 2000 Resolved
INDEPENDENT SECOND RADAR, PORTSIDE, NOT OPERATING. VESSEL REQUIRED TO REPAIR RADAR PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 2 February 2000
Resolved 2 February 2000
Fire Fighting
Issued 22 July 1999 Resolved
THERE WERE PINHOLES IN THE FIREMAIN. THEY WILL NEED TO BE FIXED PRIOR TO NEXT U.S. PORT OR NO LATER THAN 03AUG99.
Condition: Unknown
Due 3 August 1999
Resolved 5 August 1999
Navigation
Issued 22 July 1999 Resolved
FOUND THAT SLAVE RADAR WAS NOT OPERATABLE BECAUSE OF CORROSION, AND CONDESATION RESIDUE.
Condition: Unknown
Due 5 August 1999
Resolved 5 August 1999
Engineering
Issued 9 March 1999 Resolved
EMERGENCY F/O SHUTOFF (REMOTE) LOCATED ON FANTAIL ISN'T MARKED.
Condition: Unknown
Due 10 March 1999
Resolved 11 March 1999
Navigation
Issued 9 March 1999 Resolved
SMALL HYDRAULIC LEAK ORIGINATING AROUND #1 STEERING PUMP.
Condition: Unknown
Due 10 March 1999
Resolved 11 March 1999
Navigation
Issued 11 May 1998 Resolved
VESSEL OVER 10,000 GT SECOND MARINE RADAR WAS INOPERABLE.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Lifesaving
Issued 4 March 1998 Resolved
PRIOR TO DEPARTURE, DEMONSTRATE LOWERING AND LAUNCHING OF PORT LIFEBOAT. QUARTERLY TEST NOT COMPLETED.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Deck/Cargo
Issued 4 March 1998 Resolved
PRIOR TO DEPARTURE, DEMONSTRATE OPERATION OF STERN ANCHOR WINDLASS TO THE SATISFACTION OF THE CLASS SURVEYOR.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Navigation
Issued 4 March 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE A CURRENT COPY OF CHART 11417 FOR TAMPA BAY.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Lifesaving
Issued 4 March 1998 Resolved
PRIOR TO DEPARTURE, REPLACE BUOYANT LINES ON ALL LIFERING LINES.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Lifesaving
Issued 4 March 1998 Resolved
REPAIR BOTH LIFEBOAT DAVITS AS REQUIRED BY CLASS SURVEYOR. CLASS CONDEMNEDLIFEBOAT DAVITS AND FLAG STATE GRANTED PERMISSION FOR VSL TO PLACE ADDITIONAL LIFERAFTS ONBOARD UNTIL LIFEBOAT DAVITS HAVE BEEN REPAIRED.
Condition: Unknown
Due 15 July 1998
Resolved 15 July 1998
Navigation
Issued 4 March 1998 Resolved
PRIOR TO 04APR98, OBTAIN 1998 LIGHT LIST VOL. III.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 4 March 1998 Resolved
PRIOR TO DEPARTURE, REMOVE EXCESS PIPING ON MAIN DECK OR STOW PIPING IN ENGINE ROOM.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Engineering
Issued 13 January 1998 Resolved
RENEW STEEL ON CORRODED OIL CONTAINMENT UNITS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Deck/Cargo
Issued 13 January 1998 Resolved
REPLACE STERN ANCHOR CHAIN, AND INSURE WINDLASS AND CAPSTAN IS IN GOOD WORKING CONDITION._x001C_ CORRECT IN DRYDOCK IN FEB 98.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 13 January 1998 Resolved
REPAIR CORRODED GUARDRAILS IN ACCORDINANCE WITH;_x001C_ ILLC 66 ANNEX 1/25
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Construction/Loadline
Issued 13 January 1998 Resolved
REPLACE ALL WATER TIGHT DOOR GASKETS ON MAIN AND ACCOMADATION DECK; GREASE AND LOOSEN DOGS._x001C_ ILLC 64 R.12
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Accommodation/Occupational Safety
Issued 13 January 1998 Resolved
MSD NEEDS FIXED APPROVED PLACARD
Condition: Unknown
Due 3 February 1998
Resolved 3 February 1998
Documentation
Issued 19 March 1997 Resolved
VESSEL SAFETY RADIO CERTIFICATE INVALID.
Condition: Unknown
Due 13 April 1997
Resolved 13 April 1997
Navigation
Issued 19 September 1996 Resolved
PROVIDE INFORMATION FOR MANUVERING FACT SHEET INDICATING VESSEL'S _x001C_ CONDITION WHEN BALLAST AND LOADED.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Fire Fighting
Issued 19 September 1996 Resolved
PROVIDE AND INSTALL NEW LIFELINES ON FIRE SUITS WHERE THEY ARE MISSING._x001C_ IN ACCORDANCE WITH SOLAS CHAPTER II-2 REGULATION 17.3.
Condition: Unknown
Due 2 December 1996
Resolved 2 December 1996
Lifesaving
Issued 14 January 1995 Resolved
The vessel needs to provide proper working lights on each of its personal floatation devices.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Lifesaving
Issued 14 January 1995 Resolved
The vessel needs to provide Weak Links on port and starboard Liferafts.
Condition: Unknown
Due 26 January 1995
Resolved 26 January 1995
Navigation
Issued 17 August 1993 Resolved
SECONDARY RADAR INOPERATIVE
Condition: Unknown
Due 21 March 1994
Resolved 21 March 1994
Navigation
Issued 3 April 1990 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST (VOL 2) USED BY THE VSL WAS NOT CORR UP THRU NTM 01/90, WHICH WERE REASONABLY AVAILABLE AND CON- TAINED CORR APPLICABLE TO THE VSLS RTE FM SMITH PT. VA. TO BALTIMORE HBR. NO FOREIGN EQUIVALENT O/B.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Documentation
Issued 3 April 1990 Resolved
A VIO OF 33 CFR 151.25(H) IN THAT EACH COMPLETED OPERATION SPECIFIED IN THEVSLS OIL RECORD BOOK WAS NOT SIGNED BY THE PERSON IN CHARGE OF THE OPERA- TION CONCERNED.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Documentation
Issued 15 March 1990 Resolved
A VIO OF 33CFR151.25(D) IN THAT THE ENTRIES IN THE VSLS OIL RECORD BOOK_x001C_ WERE INCOMPLETE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Documentation
Issued 15 March 1990 Resolved
A VIO OF 33CFR151.25(H) IN THAT THE MASTER OR OTHER PERSON IN CHARGE FAIL-_x001C_ED TO SIGN EACH COMPLETED PAGE OF THE VSLS OIL RECORD BOOK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Documentation
Issued 15 March 1990 Resolved
A VIO OF 33CFR151.25(H) IN THAT EACH COMPLETED OPERATION SPECIFIED IN THE_x001C_ OIL RECORD BOOK WAS NOT SIGNED BY THE PERSON IN CHARGE OF THE OPERATION_x001C_ SPECIFIED._x001C_ _x001C_
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Navigation
Issued 15 March 1990 Resolved
A VIO OF 33CFR164.30 IN THAT THE US COAST PILOT VOL 3 1988 EDITION USED BY THE VSL WAS NOT CURRENTLY CORR UP THRU NTM 51/89, WHICH WERE REASONABLY_x001C_ AVAILABLE AND CONTAINED CORRS APPLICABLE TO THE VSLS RTE FM SMITH PT VA TO_x001C_BALTIMORE HBR. NO FOREIGN EQUIVALENT ON BOARD._x001C_
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Documentation
Issued 15 March 1990 Resolved
A VIO OF 33CFR156.150 IN THAT THE PERSON IN CHARGE OF THE OIL XFER DID NOT_x001C_FILL OUT AND SIGN THE DECLARATION OF INSPECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Documentation
Issued 15 March 1990 Resolved
A VIO OF 33CFR155.730 IN THAT THE VSL OPERATOR DID NOT REQUIRE THE VSLS _x001C_ CREW TO COMPLY WITH THE OTPS WHILE THE VSL WAS INVOLVED IN AN OIL XFER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 March 1990
Resolved 15 March 1990
Navigation
Issued 3 April 1989 Resolved
33 CFR 164.33(A)(1) THE VESSEL DID NOT HAVE ON BOARD MARINE CHARTS OF THE AREA TRANSITED(I.E.: BOSTON INNER HARBOR CHART NO. 13272).
Condition: Unknown
Due 3 April 1989
Resolved 3 April 1989
Navigation
Issued 8 December 1988 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE ON BOARD U.S. CHARTS 12274,& 12277,OR ITS FOREIGN EQUIVALENT WHICH WAS REQUIRED FOR THE VSLS ROUTE FROM C&D CANAL TO BALTIMORE HBR.
Condition: Unknown
Due 28 December 1988
Resolved 8 December 1988
Navigation
Issued 13 July 1988 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE USCG LIGHT LIST (VOL 2) USED BY THE VSL WAS NOT CORRECTED UP THRU NTMS 16/88, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS ROUTE FROM SMITHPT VA TO BALT HBR. NO FOREIGN EQUIVALENTS ON BOARD.
Condition: Unknown
Due 28 December 1988
Resolved 13 July 1988
Navigation
Issued 23 May 1988 Resolved
MANEUVERING INFORMATION FACT SHEET DID NOT CONTAIN A TABLE OF SPEEDS FOR THE VESSELS BOW THRUSTER I.A.W. 33 CFR 164.35(G)(3).
Condition: Unknown
Due 13 July 1988
Resolved 23 May 1988
Navigation
Issued 23 May 1988 Resolved
NO STEERING GEAR BLOCK DIAGRAM POSTED ON THE BRIDGE OR IN THE STEERING GEAR COMPARTMENT I.A.W. 33 CFR 164.35(K).
Condition: Unknown
Due 13 July 1988
Resolved 23 May 1988
Navigation
Issued 23 May 1988 Resolved
LORAN C RECIEVER DID NOT HAVE THE LABLE AND MANUFACTORERS STATEMENT RE- QUIRED BY 33 CFR 164.41(A)(1).
Condition: Unknown
Due 23 May 1988
Resolved 23 May 1988
Documentation
Issued 23 May 1988 Resolved
OIL TRANSFER PROCEDURES DID NOT CONTAIN THE INFORMATION REQUIRED BY 33 CFR155.750(A)(2)(III);(A)(3);(A)(5);(A)(7) AND (A)(8).
Condition: Unknown
Due 13 July 1988
Resolved 23 May 1988
Accommodation/Occupational Safety
Issued 23 May 1988 Resolved
TYPE II MARINE SANITATION DEVICE INSTALLED ONBOARD HAD NO CERTIFICATION LABLE NOR OTHER PROOF OF CERTIFICATION ONBOARD.
Condition: Unknown
Due 13 July 1988
Resolved 23 May 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.