The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for NORTH CAPE, retrieved 18 September 2026. mauryrecords.com/v/psix-223320.html
Documentation record
Tonnage as PSIX records it54540 - Regulatory (Subpart C or D), Gross Ton 36680 - Regulatory (Subpart C or D), Net Ton 104447 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
16 April 1991Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 343250
16 April 1991Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917591
12 April 1990Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 525216
THE VESSEL'S ECHO DEPTH SOUNDING DEVICE WAS NOT OPERABLE AS REQUIRED_x001C_ IN 33 CFR 164.35(h) _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 16 April 1991Resolved
THE VESSEL'S OILY WATER SEPERATOR WAS NOT OPERABLE AS REQUIRED IN 33 CFR _x001C_ 155.380(b)
Condition: Unknown
Due 18 May 2002
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 16 April 1991Resolved
THE VESSEL'S #1 CARGO PUMP SHUTDOWN WAS NOT OPERABLE AS REQUIRED IN_x001C_ 33 CFR 155.785(a)
Condition: Unknown
Due 16 June 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 28 September 1989Resolved
PROVE PROPER OPERATION OF 3 CM RADAR PRIOR TO NEXT U. S. PORT.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Fire Fighting
Issued 28 September 1989Resolved
PROVIDE ONE FIRE SUIT PRIOR TO NEXT U. S. PORT.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Lifesaving
Issued 28 September 1989Resolved
PROVE PROPER OPERATION OF STBD LIFEBOAT EMBARKATION LIGHT AND REMOVE OR PROPERLY DEADEND OLD CABLES FOR SAME PRIOR TO NEXT U. S. PORT.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Engineering
Issued 28 September 1989Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR PRIOR TO NEXT U. S. PORT.
Condition: Unknown
Due 28 September 1989
Resolved 28 September 1989
Fire Fighting
Issued 20 June 1988Resolved
MAKE PERMANENT REPAIRS TO THE EXHAUST PIPING SYSTEM ON THE EMERGENCY FIRE PUMP ENGINE.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Fire Fighting
Issued 6 June 1988Resolved
PROVIDE ON BOARD OPERABLE EMERGENCY FIRE PUMP IN ACCORDANCE WITH SOLAS 74, II-2 REG. 52. DEMONSTRATE OPERATIONAL TEST TO SATISFACTION OF COGIZANT OCMI.
Condition: Unknown
Due 6 June 1988
Resolved 6 June 1988
Navigation
Issued 6 June 1988Resolved
PROVIDE ON BOARD CHART OF AREA TO BE TRANSITTED (CHART #11347) IN ACCORDANCE WITH 33 CFR 164.33 (A)(1).
Condition: Unknown
Due 7 June 1988
Resolved 6 June 1988
Unknown
Issued 6 June 1988Resolved
PROVIDE ON BOARD SIGN TO WARN PERSONS APPROACHING THE GANGWAY IN ACCORDANCEWITH 46 CFR 35.30-1 (B).
Condition: Unknown
Due 6 June 1988
Resolved 6 June 1988
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.