Records from 1991 to 1999. Most recent: inspection, 11 February 1999.
Inspection history · 25
11 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425306
8 May 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415772
2 November 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 409734
25 July 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 406029
29 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 396899
9 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 387758
5 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 35374
5 February 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 171994
16 October 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 383904
17 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 106011
17 January 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 374450
19 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 645861
18 May 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1169514
16 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 366919
14 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 16263
14 May 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 95318
14 May 1994
Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1387534
26 March 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 475970
28 January 1994
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 364101
28 August 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 360316
26 May 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 505176
13 April 1993
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405376
12 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 50300
17 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 352626
3 September 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 345740
Fire Fighting
Issued 2 November 1997
Resolved
VESSEL MISSING SPANNER WRENCHES FROM ALL HOSE STATIONS._x001C_ _x001C_ SOLAS 60 REG 2/56(f)_x001C_
Condition: Unknown
Due 2 December 1997
Resolved 29 December 1997
Electrical
Issued 29 October 1996
Resolved
REPAIR, REPLACE OR REMOVE IMPROPERLY INSTALLED ELECTRICAL WIRING IN AFTER STEERING GEAR COMPARTMENT TO PREVENT SHOCK HAZARD. (SOLAS 60 REG 27). CORRECT BY 15NOV96.
Condition: Unknown
Due 15 August 1997
Resolved 15 August 1997
Engineering
Issued 9 February 1996
Resolved
GENERATOR NUMBER 2 JACKET WATER LINE LEAKING EXCESSIVELY.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Navigation
Issued 9 February 1996
Resolved
STBD STEERING PUMP MAKING EXCESSIVE NOISE. CLASS TO VERIFY OPERATION AND CORRECTION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Engineering
Issued 9 February 1996
Resolved
GENERATOR NUMBER 1 UNDER REPAIRS UNABLE TO TEST PARALLEL AND SINGLE OPERATION FOR POWER FAILURE.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996
Electrical
Issued 9 February 1996
Resolved
GENERATOR NUMBER 3 REV. POWER RELAY QUESTIONABLE, CLASS TO VERIFY OPERATION.
Condition: Unknown
Due 9 February 1996
Resolved 9 February 1996