COSTA ALLEGRA is a 1969 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1984, most recently in December 2005, along with 48 deficiencies and 4 operational controls.

Records from 1984 to 2005. Most recent: operational control imposed, 14 December 2005.

Built
1969
Last inspected
14 December 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

6916885 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
223537
Flag
SWEDEN
—
Maury page id
psix-223537

Inspections, by type

…with no type recorded20
Years with a record 10 calendar years (1984–2005)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14369 - Dead Weight, Ton
21337 - Displacement, Ton
28430 - Convention (Subpart B), Gross Ton
28430 - Regulatory (Subpart C or D), Gross Ton
11911 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 32

14 December 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2551276
4 March 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2303402
21 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2302669
19 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2295669
18 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2295423
10 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2297642
7 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2288165
29 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2282918
19 November 2004 Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · COC-CVE Initial
Physical examination · Activities Europe · Activity 2245804
8 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1077790
3 March 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 388477
3 March 1996 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1363509
1 December 1995 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1394423
20 October 1995 Administrative
Administrative · Marine Safety Center (MSC) · Activity 883502
15 February 1995 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1153258
20 January 1995 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 869171
23 November 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 372046
22 November 1994 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1407397
27 March 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 855590
18 December 1993 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 851138
19 March 1993 Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1397894
18 March 1993 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 839400
17 December 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 355186
11 December 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 355435
11 December 1992 Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1471298
2 July 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 442312
2 January 1986 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 306171
8 June 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 525053
4 April 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 538895
3 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 475923
1 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 299122
15 October 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 298370

Deficiency record · 48

Documentation
Issued 1 December 1995 Resolved
PROVIDE COMPLETE OIL TRANSFER PROCEEDURES IAW 33 CFR 155.750.
Condition: Unknown
Due 1 January 1996
Resolved 4 January 1996
Navigation
Issued 23 November 1994 Resolved
MANEUVERING FACT SHEET IS INCOMPLETE. MISSING TABLE OF SHAFT REVOLUTIONS FOR REPRESENTATIVE SPEEDS, MANEUVERING INFORMATION FOR NORMAL LOAD AND NORMAL BALLAST CONDITION FOR CALM WEATHER, NO CURRENT, DEEP WATER CONDITIONS, CLEAN HULL AND WARNING STATEMENT.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Documentation
Issued 23 November 1994 Resolved
EACH OPERATION IN THE OIL RECORD BOOK IS MISSING THE SIGNATURE OF THE PERSON IN CHARGE.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Construction/Loadline
Issued 22 November 1994 Resolved
4 hinged class(1) water tight doors shall be fitted with quick action closing devices.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Lifesaving
Issued 22 November 1994 Resolved
Conduct lifeboat drill.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Lifesaving
Issued 22 November 1994 Resolved
Repair and prove proper operation of all lifeboat lowering and releasing gear.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 22 November 1994 Resolved
Provide flag state documentation as to acceptance of construction of panelswith plywood in wall around door frame panels and in in disco walls.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 22 November 1994 Resolved
Replace handle on hose locker 1-071.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 22 November 1994 Resolved
Modify and prove proper operation of firescreen doors in Disco, so to prevent inner door from stopping firescreen doors from closing. ( FD 222 and 223 ).
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 22 November 1994 Resolved
Privide method for testing flow at end of each sprinkler zone. Demonstrate a sample of same the the Coast Guard Inspector at next inspection.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 22 November 1994 Resolved
Ensure FD 5-200 can be and is closed and latched. (Provide proper ventilation for storeroom as necessary to eliminate need to keep door open).
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Fire Fighting
Issued 22 November 1994 Resolved
Remove all materials stored in all crews stairtowers.
Condition: Unknown
Due 22 November 1994
Resolved 22 November 1994
Documentation
Issued 27 March 1994 Resolved
UPDATE "MUSTER LIST" TO INCLUDE WHO IS THE OFFICER IN CHARGE OF MAINTENANCEOF LIFESAVING EQUIPMENT AS REQUIRED BY SOLAS 74, AS AMENDED, REG III.53.3.
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Lifesaving
Issued 27 March 1994 Resolved
REMOVE COMBUSTIBLES(WOOD) BEING STORED IN THE FORWARD CREW STAIRTOWER.
Condition: Unknown
Due 27 March 1994
Resolved 27 March 1994
Fire Fighting
Issued 18 December 1993 Resolved
PROVIDE DOCUMENTATION FROM FLAG ADMINISTRATION EXPLAINING WHY DRAUGHT STOPSARE NOT REQUIRED IN BUFFET ON DECK 7 AND IN CORRIDOR DECK 4 BETWEEN FRAMES 85-124 (SOLAS 74, CH II-2, REG 35.1.1).
Condition: Unknown
Due 18 December 1993
Resolved 18 December 1993
Lifesaving
Issued 18 December 1993 Resolved
ADJUST LENGTH OF ALL LIFEBOAT EMBARKATION LADDERS SO IT WILL REACH WATER'S EDGE WITH 15 DEGREES UNFAVORABLE TRIM (SOLAS 74, CH III REG 11.7).
Condition: Unknown
Due 18 December 1993
Resolved 18 December 1993
Documentation
Issued 18 December 1993 Resolved
C.1 SUBDIVISION LOADLINE MARK TO BE INDICATED IN SHIP'S HULL(SOLAS 74, _x001C_ II-1, REG 13)
Condition: Unknown
Due 18 December 1993
Resolved 18 December 1993
Fire Fighting
Issued 18 December 1993 Resolved
ADJUST ALL FIRE SCREEN DOORS SO THAT THEY CLOSE COMPLETELY
Condition: Unknown
Due 18 December 1993
Resolved 18 December 1993
Navigation
Issued 18 December 1993 Resolved
REVISE & ADJUST THE "EMERGENCY STEERING STATION" IN ORDER TO PROVIDE STEERING WHEEL OPERATOR WITH A SAFE PLACE TO STAND.
Condition: Unknown
Due 18 December 1993
Resolved 18 December 1993
Fire Fighting
Issued 19 March 1993 Resolved
Repair and demonstrate operation of fire screen doors No. 090,098, and_x001C_ 104.
Condition: Unknown
Due 19 March 1993
Resolved 19 March 1993
Documentation
Issued 11 December 1992 Resolved
Oil Transfer Procedure was incomplete, missing means of communication, and means of reporting oil discharge,(phone number)
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Navigation
Issued 11 December 1992 Resolved
Manuevering fact sheet missing Table of speed at which bow thruster is affected.
Condition: Unknown
Due 14 April 1993
Resolved 14 April 1993
Fire Fighting
Issued 11 December 1992 Resolved
PROVE PROPER OPERATION/CLOSURE OF ALL FIRE SCREEN DOORS. VESSEL TO PROVIDEAN ON-SCENE FIRE PATROLMAN TO ENSURE ALL FSD'S PROPERLY CLOSE AFTER FIRES AND FIRE DRILLS. UPON VERIFICATION THAT ALL FSD'S ARE FULLY OPERATIONAL, THE ON-SCENE FIRE PATROL MAY BE WITHDRAWN.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Lifesaving
Issued 11 December 1992 Resolved
PLACE SIGNS THAT CLEARLY INDICATE ESCAPE ROUTE IN ALL HORIZONTAL STAIRWAY ENCLOSURES.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Electrical
Issued 11 December 1992 Resolved
INSTALL SFFICIENT EMERGENCY LIGHTS IN THE PANTRY FOR THE YACHT CLUB BUFFET.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 11 December 1992 Resolved
REPLACE DEAD BOLT LOCKS ON STAIRWAY DOORS LEADING TO OPENING DECKS WITH ACCEPTABLE OPENING TYPE LOCKS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Documentation
Issued 11 December 1992 Resolved
CORRECT THE PASSENGER SHIP SAFETY CERTIFICATE TO SHOW THE CORRECT NUMBER OFLIFERAFTS FOR WHICH APPROVED LAUNCHING DEVICES ARE REQUIRED, AND NUMBER OF PERSONS IN THEM.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Electrical
Issued 11 December 1992 Resolved
INSTALL SUFFICIENT EMERGENCY LIGHTS IN THE PANTRY FOR THE NIGHT CLUB ON DECK #7.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 11 December 1992 Resolved
INSTALL EXIT SIGNS FOR THE PORT AND STBD DOORS IN THE ATHWARTSHIP CORRIDOR AT THE FORWARD END OF DECK #7.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
ENCLOSE ELEVATOR WITH "A" CLASS ENCLOSURE IN FORWARD STOREROOM AT FRAME 150, DECKS 0 - 3.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Electrical
Issued 11 December 1992 Resolved
DEMONSTRATE EMERGENCY LIGHTS IN THE FOLLOWING LOCATIONS: A) CHILDREN'S PLAYROOM-DECK #9, B) MASSAGE AND WHIRLPOOL ROOMS-DECK #9, C) OUTSIDE YACHT CLUB BUFFET-PORT DECK #7, D) PORTSIDE BETWEEN LIFEBOATS 4 & 6-DECK #6, E) PORTSIDE LIFERAFT #2, F) PORT AND STBD WEATHER DECK AFT OF BRIDGE WINGS-DK8
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Electrical
Issued 11 December 1992 Resolved
DEMONSTRATE EMERGENCY LIGHTS IN THE FOLLOWING LOCATIONS (CONT.): G) PORTSIDE OF AFTER DECK HOUSE ON WEATHER DECK BULKHEAD - DECK #8.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Documentation
Issued 11 December 1992 Resolved
PROVIDE MEDICAL CERTIFICATES FOR EXAMINATION FOR ALL CREW MEMBERS ON BOARD IN ACCORDANCE WITH ILO 147.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
PROPERLY INSTALL MISSING INSULATION ON THE STARBOARD SIDE DECK #7 IN WAY OFTHE ELEVATOR IN ACCORDANCE WITH APPROVED VESSEL PLANS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
PROVIDE SPARE SPRINKLER HEADS AT EACH SPRINKLER STATION AS PER SOLAS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Lifesaving
Issued 11 December 1992 Resolved
DEMONSTRATE AT NEXT QUARTERLY CONTROL VERIFICATION EXAM THE LIFEBOAT CREW KNOWLEDGE IN THE "EMERGENCY RELEASE" FOR THE FALLS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
MAINTAIN DECK TO DECK INTEGRITY IN FORWARD STOREROOM AT FRAME 155, DECKS 1 - 2 BY "A" CLASS ENCLOSURE.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
INSTALL MANUAL CALL POINTS AS PROMISED IN FLAG STATE REPRESENTATIVES FAX OF3 DEC 92.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
UNTIL SWITCH AND RELEASE ARE INSTALLED, MUSTER LIST MUST SHOW PERSON ASSIGNED TO CHECK DOOR 4/180B IN EMERGENCY.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 11 December 1992 Resolved
IN STAIRWAY DECK 5 AFT - SIGN INDICATING MUSTER STATION IS CONFUSING (DIRECTS PEOPLE TO OUTSIDE DEAD END BALCONY).
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 11 December 1992 Resolved
PROVIDE RINA APPROVAL ON FLAME CARTS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
PROVIDE FOR ALL SPRINKLER STATIONS, A LIST OR PLAN INDICATING SPACES COVERED AND THE LOCATION OF THE ZONE.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
INSTALL DRAUGHT STOPS AS REQUIRED BY SOLAS 74/81/83 II-2 REG 35.1.1 IN BUFFET ON DECK 7 AND CORRIDOR DECK 4 BETWEEN FRAMES 85 - 124.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Fire Fighting
Issued 11 December 1992 Resolved
PROVIDE GENERAL ALARM BELL INSIDE PANTRY, DECK #6, SHOP'S AREA, IN ACCORDANCE WITH FIRE CONTROL PLANS.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 11 December 1992 Resolved
WASTE RECEPTICLES IN PASSENGER CABINS DO NOT COMPLY WITH SOLAS CHAPTER II- 2, REGULATION 18.5
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 11 December 1992 Resolved
INSTALL EXIT SIGNS AT THE TOP OF THE STAIRWAYS (PORT AND STBD) LEADING FROMTHE DINING ROOM TO DECK #7.
Condition: Unknown
Due 11 December 1992
Resolved 11 December 1992
Accommodation/Occupational Safety
Issued 15 October 1984 Resolved
MSD TYPE II MISSING MARINE SANITATION DEVICES CERTIFICATION PLACARD
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984
Navigation
Issued 15 October 1984 Resolved
U.S. COAST PILOT 20TH EDITION, JUNE 1984 CONTAINED NO CORRECTIONS, THERE ARE SIX (6) APPLICABLE NOTICE TO MARINER CORRECTIONS.
Condition: Unknown
Due 15 October 1984
Resolved 15 October 1984

Ownership record