Records from 1984 to 1991. Most recent: inspection, 16 September 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
16 September 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 711534
28 August 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353262
18 August 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 345339
18 August 1991
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1353292
16 October 1990
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 339809
22 January 1990
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 486993
4 April 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 329485
4 April 1989
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1203713
30 September 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 325819
7 April 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 322446
7 April 1988
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031918
16 December 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 498235
14 June 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 309561
14 June 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 996271
29 July 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 303452
1 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 301202
1 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 979589
22 August 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 297448
18 April 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 452043
Deck/Cargo
Issued 28 August 1991
Resolved
Remove temporary repair on main discharge cargo pipeline and make permanentrepairs. Damaged area forward of pump room. Pipeline to hydrotested to 1.5_x001C_MAWP.
Condition: Unknown
Due 26 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 28 August 1991
Resolved
clean excessive hydrolic oil from behind cargo control consoles, find leaking connections and make permanent repairs.
Condition: Unknown
Due 26 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 28 August 1991
Resolved
clean excessive oil in engine room bilges.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 28 August 1991
Resolved
remove broken gate valve on intake pipeline to bilge transfer pump.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 28 August 1991
Resolved
make permanent repairs to bilge pump manifold, due to numerous small leaks and temporary patch repairs.
Condition: Unknown
Due 26 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 28 August 1991
Resolved
remove temporary repairs on lube oil return line outboard of lube oil cleaning unit.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Fire Fighting
Issued 28 August 1991
Resolved
make permanent repairs to t-section of firemain pipeline just forward of pump room, item has excessive leaks.
Condition: Unknown
Due 6 September 1991
Resolved 6 September 1991
Construction/Loadline
Issued 28 August 1991
Resolved
remove temporary repairs on starboard cargo pump (no1) suction intake line and make permanent repairs, and hydro test.
Condition: Unknown
Due 26 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 18 August 1991
Resolved
33 CFR 151.63(a) THE MASTER OF THE VESSEL DID NOT ENSURE ALL GARBAGE WAS TAKEN ASHORE IN ACCORDANCE WITH 33 CFR 151.67._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 August 1991
Resolved
MAKE PERMANENT REPAIRS TO IGS AUDIBLE ALARMS AND PRESSURE/OXYGEN SENSORS_x001C_ AND DEMONSTRATE PROPER OPERATION OF ALL ALARMS AND SHUT-DOWNS PRIOR TO_x001C_ LOADING CARGOES REQUIRING INERTING.
Condition: Unknown
Due 18 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 18 August 1991
Resolved
PRIOR TO LOADING ANY OIL CARGOES MAKE PERMANENT REPAIRS TO HOLE BETWEEN #4_x001C_CARGO TANK AND #2 WING BALLAST TANK STBD IN WAY OF GRAIN LOADING CHUTE_x001C_ PENETRATION AT AFT CORNER OF CARGO HATCH #4.
Condition: Unknown
Due 18 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 August 1991
Resolved
CARGO TANK ULLAGE & SAMPLING OPENINGS OPEN WITH OUT PERSON IN ATTENDANCE_x001C_ AND NOT EQUIPPED WITH FLAME SCREENS.
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Construction/Loadline
Issued 18 August 1991
Resolved
CLEAN EXCESS OIL FROM CARGO PUMP ROOM LOWER BILGES PRIOR TO CARGO OPS.
Condition: Unknown
Due 19 September 1991
Resolved 5 September 1991
Fire Fighting
Issued 18 August 1991
Resolved
MAKE TEMPORARY REPAIR TO LEAK IN FIRE MAIN PIPING ON C/L FWD OF PUMPROOM._x001C_ TEST FOR LEAKS TO SATIS OF ATTEND MARINE INSP. PRIOR TO CARGO DISCH. PERM._x001C_REPAIR TO BE COMPLETED PRIOR TO ARRIVAL NEXT U.S. PORT.
Condition: Unknown
Due 19 September 1991
Resolved 5 September 1991
Accommodation/Occupational Safety
Issued 18 August 1991
Resolved
INSTALL METAL GRATINGS ON CATWALK FORWARD OF PUMP ROOM.
Condition: Unknown
Due 18 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 18 August 1991
Resolved
RENEW FLAME SCREENS ON ALL MAIN DECK BUNKER TANK VENTS P&S OF DECKHOUSE_x001C_ PRIOR TO RELOADING ANY COMBUSTIBLE OR FLAMMABLE OIL CARGOES.
Condition: Unknown
Due 18 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 August 1991
Resolved
RENEW PV VALVE FLAME SCREENS ON P&S SLOP TANKS PRIOR TO CARGO OPS.
Condition: Unknown
Due 18 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 August 1991
Resolved
RENEW CARGO TANK PV VALVE FLAME SCREENS PRIOR TO RELOADING COMBUSTIBLE OR_x001C_ FLAMMABLE OIL CARGOES.
Condition: Unknown
Due 18 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 18 August 1991
Resolved
INSTALL FLAME SCREENS IN ALL BALLAST TANK VENTS PRIOR TO RELOADING ANY COMBUSTIBLE OR FLAMMABLE OIL CARGOES.
Condition: Unknown
Due 18 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 18 August 1991
Resolved
INSTALL FLAME SCREENS ON VENTS FOR BETWEEN TANK VOIDS ON CENTERLINE PRIOR_x001C_ TO RELOADING ANY COMBUSTIBLE OR FLAMMABLE OIL CARGOES.
Condition: Unknown
Due 18 September 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 18 August 1991
Resolved
REMOVE BUCKETS OF OIL AND OILY RAGS FROM AFT STEERING ROOM PRIOR TO CARGO_x001C_ OPS.
Condition: Unknown
Due 19 September 1991
Resolved 5 September 1991
Fire Fighting
Issued 4 April 1989
Resolved
EMERGENCY FIRE PUMP DOES NOT PUT OUT ENOUGH WATER PRESSURE ON TWO HOSES SIMULTANEOUSLY. DEFICIENCY TO BE CORRECTED PRIOR TO VSL'S DEPARTURE FROM CORPUS CHRISTI.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Deck/Cargo
Issued 7 April 1988
Resolved
VESSEL CARRYING OIL PRODUCT AS A CARGO. VESSEL NOT CLASSIFIED AS A PRODUCT CARRIER ON ITS IOPP CERTIFICATE.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988
Documentation
Issued 7 April 1988
Resolved
VESSEL COULD NOT PRODUCE A RECORD OF A PROPER STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING CONDUCTED WITHIN THE LAST YEAR.
Condition: Unknown
Due 7 April 1988
Resolved 7 April 1988