Records from 1985 to 2002. Most recent: inspection, 10 January 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
10 January 2002
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1477339
25 May 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 653099
10 May 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 653100
30 March 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 357153
15 December 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 355027
28 November 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 354673
27 October 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 353860
24 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 353399
4 September 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 353012
2 August 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 9463
14 July 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 351823
19 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 350824
14 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 653098
8 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 653097
6 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 104922
5 May 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 350584
27 April 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 673257
2 April 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 349732
7 June 1990
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 337455
28 May 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 529315
18 November 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 305485
Navigation
Issued 24 May 1993
Resolved
A VIOLATION OF 33 C.F.R. 164.35(c) IN THAT THE VESSEL FAILED TO HAVE A CURRENT MAGNETIC COMPASS DEVIATION TABLE, GRAPH OR COMPASS COMPARISON RECORD FOR THE STEERING COMPASS IN THE WHEELHOUSE.
Condition: Unknown
Due 25 May 1993
Resolved 10 January 2002
Resolution: Administrratively closed due to age of deficiencies.
Engineering
Issued 24 May 1993
Resolved
A VIOLATION OF 33 C.F.R. 156.150(a) IN THAT THE PERSON IN CHARGE, ON THE VESSEL'S SIDE OF THE TRANSFER FAILED TO INITIAL IN THE APPROPRIATE SPACE THAT EACH SPECIFIC REQUIREMENT HAD BEEN MET ON THE DECLARATION OF INSPECTION FORM DATED, 14 MAY 93.
Condition: Unknown
Due 25 May 1993
Resolved 10 January 2002
Resolution: Administrratively closed due to age of deficiencies.
Fire Fighting
Issued 30 March 1993
Resolved
ALL FIRE HOSES ON DECK LEAKED EXCESSIVELY.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Construction/Loadline
Issued 30 March 1993
Resolved
VESSELS LOADLINE ON THE STARBOARD SIDE WAS SUBMERGED SIX INCHES.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Accommodation/Occupational Safety
Issued 30 March 1993
Resolved
VESSELS MARINE SANITATION DEVICE WAS NOT OPERABLE.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Engineering
Issued 30 March 1993
Resolved
VESSEL'S OILY WATER SEPARATOR WAS NOT OPERABLE._x001C_ _x001C_
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Accommodation/Occupational Safety
Issued 30 March 1993
Resolved
VESSEL DID NOT PROVIDE ADEQUATE LIGHTING THROUGHOUT THE SHIP.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Accommodation/Occupational Safety
Issued 30 March 1993
Resolved
VESSELS BATHROOM DECKS WERE ROTTED OUT AND FULL OF MUD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Fire Fighting
Issued 30 March 1993
Resolved
WHEN EMERGENCY FIRE PUMP WAS TURNED ON, IT FILLED THE ENGINE ROOM WITH SMOKE.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Lifesaving
Issued 30 March 1993
Resolved
LIFEBOAT ON VESSEL DID NOT OPERATE.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Lifesaving
Issued 30 March 1993
Resolved
BOTH LIFEBOATS ON SOFIA N. NEEDED TO REPLACE EXHAUST HOSES.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Accommodation/Occupational Safety
Issued 30 March 1993
Resolved
REPAIR OR RENEW WATERTIGHT FLORESCENT LIGHT FIXTURES IN MACHINERY SPACES AND WIRE IN GOOD ACORDANCE WITH GOOD MARINE PRACTICE.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Accommodation/Occupational Safety
Issued 30 March 1993
Resolved
PROVIDE GLOBES AND GUARDS ON MACHINERY SPACE INCANDESCENT LIGHT FIXTURES.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Engineering
Issued 30 March 1993
Resolved
REPAIR O RING SEAL IN #5 CYLINDER OF MAIN ENGINE JACKET WATER SYSTEM.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Construction/Loadline
Issued 30 March 1993
Resolved
VESSELS LOADLINE ON PORT SIDE WAS ILLEGIABLE.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Documentation
Issued 30 March 1993
Resolved
VESSEL'S BUNKER PROCEDURES WERE MISSING: PRODUCTS CARRIED, PRODUCT PARTICULARS, AND MARINE SAFETY DATA SHEETS FOR THE PRODUCTS TRANSFERED.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Unknown
Issued 30 March 1993
Resolved
ENGINE ROOM COVERED IN GREASE, MUD, AND OIL.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Electrical
Issued 30 March 1993
Resolved
THE ENGINE ROOM HAD EXPOSED ELECTRICAL WIRES._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Electrical
Issued 30 March 1993
Resolved
ELECTRICAL PANEL BY THE OILY WATER SEPARATOR WAS NOT SECURE.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Deck/Cargo
Issued 30 March 1993
Resolved
VESSELS PORT SCUPPER AFT WAS LEAKING OVER THE SIDE.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Engineering
Issued 30 March 1993
Resolved
MAIN ENGINE SUCTION LINE HAD A LEAK LOCATED AT STBD/FWD BILGE_x001C_ IN ENGINE ROOM.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Engineering
Issued 30 March 1993
Resolved
VESSEL HAD LUBE OIL LEAKS ON THE MAIN ENGINE AFT OIL ACCUMLATORS.
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Electrical
Issued 30 March 1993
Resolved
REPLACE MISSING ELECTRICAL COVER ON MAIN SWITCHBOARD #3 GENERATOR.
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Electrical
Issued 30 March 1993
Resolved
REPLACE ELECTRICAL MATTING IN FRONT OF ELECTRICAL SWITCHBOARD.
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Electrical
Issued 30 March 1993
Resolved
DEMONSTRATE PROPER OPERATION OF ALL GENERATORS.
Condition: Unknown
Due 30 April 1993
Resolved 10 January 2002
Resolution: Administrratively closed due to age of deficiencies.
Construction/Loadline
Issued 30 March 1993
Resolved
REPAIR FUEL OIL LEAKS AND REMOVE RAGS FROM GENERATORS.
Condition: Unknown
Due 16 April 1993
Resolved 16 April 1993
Engineering
Issued 30 March 1993
Resolved
REPAIR O RING SEAL IN FWD CYLINDER OF MAIN ENGINE JACKET WATER SYSTEM.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Electrical
Issued 30 March 1993
Resolved
REPAIR ELECTRICAL PANEL TO BOILER STARBOARD SIDE (PANEL P-35)._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Navigation
Issued 2 April 1992
Resolved
IN THAT THE VESSEL DID NOT HAVE A CURRENT OR CORRECTED COPY OF THE U.S. COAST PILOT. THE VESSEL HAD A 1990 EDITION WITH NO CORRECTIONS.
Condition: Unknown
Due 3 April 1992
Resolved 6 April 1992
Navigation
Issued 2 April 1992
Resolved
33CFR164.11(r) IN THAT THE VESSEL DID OPERATE IN THE WATERS OF THE U.S._x001C_ WITHOUT ALL REQUIRED NAVIGATIONAL EQUIPMENT OPERATIONAL.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Documentation
Issued 2 April 1992
Resolved
IN THAT THE LOAD LINE WAS MISSING FROM THE HULL. IT HAD BEEN WORN OFF, NOTPROPERLY MAINTAINED.
Condition: Unknown
Due 3 April 1992
Resolved 6 April 1992
Documentation
Issued 2 April 1992
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 April 1992
Resolved 6 April 1992
Navigation
Issued 2 April 1992
Resolved
IN THAT THE REQUIRED WARNING STATEMENT WAS NOT FOUND ON THE TURNING CIRCLE DIAGRAM.
Condition: Unknown
Due 3 April 1992
Resolved 3 April 1992
Navigation
Issued 2 April 1992
Resolved
IN THAT THE VESSEL DID NOT HAVE A CURRENT OR CORRECTED COPY OF US LIGHT LIST FOR THE AREA TRANSITED. THE VESSEL HAD A 1990 EDITION WITH NO CORRECTIONS.
Condition: Unknown
Due 3 April 1992
Resolved 6 April 1992
Navigation
Issued 2 April 1992
Resolved
IN THAT THE VESSEL DID NOT HAVE A STEERING GEAR CHANGE OVER INSTRUCTIONS AND DIAGRAM.
Condition: Unknown
Due 2 April 1992
Resolved 3 April 1992
Engineering
Issued 2 April 1992
Resolved
IN THAT THE VESSEL"S OIL TRANSFER PROCEDURES WERE INCOMPLETE. THERE WAS NOLINE DIAGRAM AVAILABLE.
Condition: Unknown
Due 3 April 1992
Resolved 6 April 1992
Engineering
Issued 2 April 1992
Resolved
IN THAT THE VESSEL HAD BUNKER CONNECTIONS THAT WERE NOT SECURED PROPERLY. THREE CONNECTIONS HAD ONLY THREE BOLTS. ONE CONNECTION WAS MISSING THE BLANK FLANGE.
Condition: Unknown
Due 2 April 1992
Resolved 3 April 1992
Engineering
Issued 2 April 1992
Resolved
IN THAT THE VESSEL'S BUNKER CONTAINMENT WAS PLUGGED WITH A RAG, AND LEAKINGONTO DECK.
Condition: Unknown
Due 2 April 1992
Resolved 3 April 1992
Electrical
Issued 2 April 1992
Resolved
IN THAT THE VESSEL DID HAVE ELECTRICAL DISTRIBUTION PANELS HAD COVERS REMOVED AND WIRES RUNNING INTO THEM SO AS THAT THE PANEL CAN NOT BE CLOSED.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Fire Fighting
Issued 2 April 1992
Resolved
FOUND ON BOARD IN A FIRE BOX A HOSE THAT WOULD NOT MATE UP TO ANY FIRE PLUGON BOARD THE SHIP. THE SHIP USED A CAM LOCK CONNECTION, THE HOSE AND NOZZLE FOUND WERE THREADED.
Condition: Unknown
Due 2 April 1992
Resolved 3 April 1992
Navigation
Issued 2 April 1992
Resolved
33CFR164.37 VESSEL DID NOT HAVE A PROPERLY WORKING INDEPENDENT SECOND MARINE RADAR.
Condition: Unknown
Due 3 April 1992
Resolved 6 April 1992
Electrical
Issued 2 April 1992
Resolved
IN THAT THE VESSEL HAD ELECTRICAL CABLES PULLED OUT OF BOXES, NOT PROPERLY SECURED THRU OUT THE SHIP.
Condition: Unknown
Due 6 May 1992
Resolved 6 May 1992
Navigation
Issued 2 April 1992
Resolved
33CFR164.53 IN THAT THE COTP WAS NOT NOTIFIED THAT THE VESSEL ENTERED THE NAVIGABLE WATERS WITH A SECONDARY MARINE RADAR THAT WAS NOT WORKING PROPERLY.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Navigation
Issued 7 June 1990
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART #12245_x001C_ OR ITS FOREIGN EQUIV WHICH WAS REQ FOR THE VSL'S ROUTE FROM VA. CAPES_x001C_ TO NORFOLK&SOUTHERN COAL PIER._x001C_ _x001C_
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Navigation
Issued 18 November 1985
Resolved
VESSEL DID NOT HAVE A STEERING GEAR BLOCK DIAGRAM POSTED ON THE BRIDGE AS REQUIRED BY 33 CFR 164.35 (K).
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Navigation
Issued 18 November 1985
Resolved
VESSEL DID NOT HAVE TIDAL CURRENT TABLES OR EQUIVALENT ONBOARD AS REQUIRED BY 33 CFR 164.33 (A) (3) (II).
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Documentation
Issued 18 November 1985
Resolved
VESSEL IOPP CERTIFCATE EXPIRED ON 11 OCTOBER 1985. REF: 33 CFR 151.19 (B), VESSEL HAD INVALID IOPP ONBOARD.
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985