MAURY USCG vessel records Sign in
← All vessels

THE TOPAZ

THE TOPAZ is a 1956 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1985, most recently in January 2007, along with 95 deficiencies and 1 operational control.

Records from 1985 to 2007. Most recent: inspection, 22 January 2007.

Built
1956
Last inspected
22 January 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

5103924 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
223641
Flag
BAHAMAS, THE
—
Maury page id
psix-223641

Inspections, by type

…with no type recorded12
Years with a record 18 calendar years (1985–2007)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14637 - Simplified, Net Ton
7071 - Dead Weight, Ton
27258 - Displacement, Ton
14637 - Convention (Subpart B), Net Ton
32327 - Convention (Subpart B), Gross Ton
32327 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 75

22 January 2007 COC-CVE Quarterly
Type not classified · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2859806
18 October 2006 ISPS III Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2803219
11 October 2006 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2798438
5 June 2006 Ballast Water Examination · ISPS III Exam · COC-CVE Annual · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2670438
18 July 2005 Random ISPS/MTSA/PSC · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2430514
6 May 2005 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2351382
2 May 2005 COC-CVE Quarterly · Deficiency Check · Ballast Water Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2347870
20 January 2005 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2278061
1 December 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2251048
4 November 2004 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2234492
4 October 2004 NPV Safety Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2213004
10 September 2004 COC-CVE Annual
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2192094
30 June 2004 ISPS II Exam
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2117873
4 June 2004 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2088324
21 March 2004 Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 2023025
21 March 2004 Type not recorded
No type recorded · GROUP HONOLULU · USCG Oceania District (CGD-O) · Activity 2028445
7 September 2003 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1901074
7 September 2003 Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1910209
8 August 2003 Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1869419
26 February 2000 Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1381808
10 November 1999 Control Verification · MARPOL Annex I Examination · Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1372828
28 October 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 422138
13 October 1998 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 801703
8 August 1998 Quarterly Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1423060
1 August 1998 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 45010
8 May 1998 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1124925
4 September 1994 MARPOL Annex V Examination · Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1173160
19 June 1994 Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1020394
4 March 1994 Quarterly Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1410931
21 January 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1162314
14 January 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 850508
3 December 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 362915
3 December 1993 MARPOL Annex I Examination · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1397990
6 November 1993 Examination of Repairs
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1156647
5 November 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358206
19 October 1993 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 840842
2 September 1993 MARPOL Annex V Examination · Control Verification · MARPOL Annex II Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1141728
27 May 1993 MARPOL Annex V Examination · MARPOL Annex II Examination · Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1151756
11 March 1993 MARPOL Annex V Examination · Control Verification · MARPOL Annex II Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1148521
3 December 1992 Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 830803
3 September 1992 MARPOL Annex II Examination · Control Verification · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 954347
4 June 1992 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1267824
9 April 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 120784
12 March 1992 Control Verification · Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1259919
5 December 1991 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 959842
19 September 1991 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 940871
13 June 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 941985
14 March 1991 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 915965
13 December 1990 Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 899389
27 September 1990 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1229184
20 September 1990 Examination of Repairs
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1213012
21 June 1990 Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 930381
29 March 1990 Deficiency Check · Control Verification
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 905487
13 March 1990 Certificate of Compliance
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 908710
1 March 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 898783
8 February 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1218062
22 December 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1236378
13 October 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1011769
10 July 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1031065
10 April 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1042073
9 January 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1037814
9 January 1989 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1194128
14 October 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1045204
11 July 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1208128
11 April 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 994492
11 January 1988 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1013507
9 October 1987 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1013166
10 July 1987 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1015445
13 April 1987 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1023063
12 January 1987 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1314396
13 October 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1009459
14 July 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1292794
18 April 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 999410
13 January 1986 Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299838
11 January 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 299822

Deficiency record · 95

Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 5 June 2006 Resolved
Submit update to NVMC to provide the correct first name of [name withheld].
Action required: 705 - Other - as specified
Due 6 June 2006
Resolved 5 June 2006
Resolution: Corrected while onboard.
Fire Fighting › Grease Extraction Hood › General
Issued 10 September 2004 Resolved
Clean out the grease from the overhead in the crew galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Cleaned while onboard.
Fire Fighting › Grease Extraction Hood › General
Issued 10 September 2004 Resolved
Clean out grease from the cutout switch for the fryer, in the crew galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Cleaned while onboard.
Lifesaving › Lifeboat Equipment › Tools (engine)
Issued 10 September 2004 Resolved
Tool kits are missing from the lifeboats.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Toolkits supply to boats while onboard.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 10 September 2004 Resolved
Crew was not able to start #14 lifeboat / tender.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Witness proper operation of the boat in the water.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 September 2004 Resolved
Fire door #14A, for fan room is missing latching assembly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Latching assembly replaced while onboard.
Fire Fighting › Structural - A Class Divisions › Store-rooms
Issued 10 September 2004 Resolved
Side shell door area in way of the information deck used as storerooms for washers and dryer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Area was cleared while onboard.
Fire Fighting › Structural - A Class Divisions › Store-rooms
Issued 10 September 2004 Resolved
Supplies being stored under stairway #3 deck #4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 September 2004
Resolution: Area cleaned out while onboard.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 10 September 2004 Resolved
Port shaft seal leaking approximately 5 gallons of water a minute. Class surveyor issued a condition to have fixed by 30 November 2004. This is a recurring item found by other previous Port State non US exams.
Action required: 705 - Other - as specified
Due 30 November 2004
Resolved 4 November 2004
Resolution: Received Class report from Lloyd''s Register showing that the tail shaft seal has been repaired.
Construction/Loadline › Hull › Side Shell
Issued 10 September 2004 Resolved
Deck 3 port and starboard portholes are leaking. Class surveyor issued a condition to have fixed by 30 January 2005.
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 20 January 2005
Resolution: Received Class report from Lloyd''s Register showing that Item has been corrected.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 10 September 2004 Resolved
Test the photoluminesent strips as required by IMO Res 752 (18) 9.2. Strips are to be tested every 5 years.
Action required: 705 - Other - as specified
Due 10 December 2004
Resolved 1 December 2004
Resolution: Received report showing that testing of photoluminescent strips has been completed.
Operations/Management › Drills/Instruction › Launching/Recovery of Survival Craft
Issued 10 September 2004 Resolved
Vessel did not have training davit liferaft and was not willing to launch one from the vessel-required number, so a deficiency was issued to launch a davit liferaft at next US Port.
Action required: 705 - Other - as specified
Resolved 6 May 2005
Resolution: Vessel had a training davit liferaft and it was launched over the portside and was verified by CG Inspectors. All sat.
Electrical › Electrical Distribution System (service)
Issued 21 March 2004 Resolved
Provide mat in rear of electrical panels in Engine Control Room IAW SOLAS 60 II/27.A.i.i. LEGACY COMPONENT DESC: Mat
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 4 June 2004
Stability › Weathertight Integrity
Issued 21 March 2004 Resolved
Repair clamping devices for door to Emergency Battery Room IAW ICLL Reg 12. LEGACY COMPONENT DESC: Clamping Devices
Action required: 15 - Rectify deficiencies by next port
Due 4 June 2004
Resolved 21 March 2004
Stability › Weathertight Integrity
Issued 21 March 2004 Resolved
Install gaskets for all swinging doors, port and stbd side in vicinity of Emergency Generator Room IAW ICLL Reg 12. LEGACY COMPONENT DESC: Gaskets
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 4 June 2004
Electrical › Electric Supply System (service)
Issued 21 March 2004 Resolved
Repair indication lights for 4 Closed and 5 Closed on Fire Door Panel located on the Bridge IAW SOLAS 74 amend II-2/41-2.4.2. LEGACY COMPONENT DESC: Indication Lights
Action required: 15 - Rectify deficiencies by next port
Resolved 4 June 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 21 March 2004 Resolved
Provide ready means of escape in passageway of Emergency Generator Room as required by SOLAS 60 II/68 and properly store expired batteries in noted passageway. LEGACY COMPONENT DESC: Means of Escape
Action required: 15 - Rectify deficiencies by next port
Resolved 4 June 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 21 March 2004 Resolved
Repair inoperable/jammed door that gives access to Emergency Generator Room, Door #63, IAW SOLAS amend II-1/3-1. LEGACY COMPONENT DESC: Jammed Door
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Resolved 4 June 2004
Fire Fighting › Structural Fire Protection - General
Issued 8 August 2003 Resolved
Numerous empty cabins / abandoned spaces found with excess amounts of combustible materials in stowage where insufficient fire protection was available since spaces not catagorized as store rooms. Ship to restow these areas to satisfaction of USCG upon arrival next US port. Currently in progress. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 August 2003
Resolved 7 September 2003
Engineering › Steam System (main)
Issued 8 August 2003 Resolved
Numerous areas of main and auxiliary steam lines found with missing lagging. Ventilation ducting found with unauthorized vent holes installed in way of steam lines, and missing guards on much rotating equipment. Repair to USCG approval upon arrival next US port. Work is currently in progress. LEGACY COMPONENT DESC: Lagging/Insulation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2003
Resolved 7 September 2003
Documentation › Safety Management System
Issued 8 August 2003 Resolved
Vessel must submit and gain approval from USCG office of MSC for a vessel security plan that meets the requirements of 33CFR120 and NVIC 04-02 prior to returning to US waters. LEGACY COMPONENT DESC: Potential Emergency Situations ID Procedures
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Due 10 August 2003
Resolved 7 September 2003
Fire Fighting
Issued 8 May 1998 Resolved
INSTALL SPRINKLERS AND SMOKE/HEAT DETECTORS IN ALL WALK IN REFRIGERATION BOXES. (SOLAS 74, REG 12)
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Fire Fighting
Issued 8 May 1998 Resolved
INSTALL SMOKE DETECTION AND SPRINKLERS IN ALL PUBLIC AND COMMON CREW AREAS.
Condition: Unknown
Due 8 May 1998
Resolved 8 May 1998
Electrical
Issued 19 June 1994 Resolved
COVER THE BARE ELECTRICAL WIRING IN THE BULKHEAD NEXT TO ROOM R-87
Condition: Unknown
Due 19 June 1994
Resolved 19 June 1994
Fire Fighting
Issued 19 June 1994 Resolved
INSTALL METAL DOORS APPROVED BY CLASSIFICATION SOCIETY BEHIND THE WOODEN VENTILATION DOOR ON FAN ROOM NO. 12
Condition: Unknown
Due 19 June 1994
Resolved 19 June 1994
Accommodation/Occupational Safety
Issued 19 June 1994 Resolved
REPLACE THE MOTOR ENCLOSURE OVER COMMUTATOR AND SHAFTING OF SMOKE DETECTIONEQUIPMENT IN CO2 ROOM
Condition: Unknown
Due 19 June 1994
Resolved 19 June 1994
Accommodation/Occupational Safety
Issued 19 June 1994 Resolved
REMOVE CLEANING SUPPLIES AND EQUIPMENT FROM ELECTRICAL ROOM NEXT TO CABIN 218
Condition: Unknown
Due 19 June 1994
Resolved 19 June 1994
Fire Fighting
Issued 19 June 1994 Resolved
PROVE THE PROPER OPERATION OF F.S.D. M-10
Condition: Unknown
Due 19 June 1994
Resolved 19 June 1994
Fire Fighting
Issued 3 December 1993 Resolved
Make available for testing 12 sprinkler lines to be tested at the end of the station. Which will prove the line clear for water passage throughout the line.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Lifesaving
Issued 3 December 1993 Resolved
Conduct additional firefighting training and drills in procedures and show improvement.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Lifesaving
Issued 3 December 1993 Resolved
Lower and operate all starboard lifeboats and tenders in the presence of a Coast Guard Marine Inspector.
Condition: Unknown
Due 21 January 1994
Resolved 21 January 1994
Lifesaving
Issued 3 December 1993 Resolved
Remove all flamable liquids and paints in forward deck stores and stow properly.
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Electrical
Issued 3 December 1993 Resolved
Remove or dead end live wires in forepeak and/or reconnect electrical appliances where missing. Install light globes in area where missing..
Condition: Unknown
Due 19 January 1994
Resolved 19 January 1994
Electrical
Issued 27 May 1993 Resolved
REPAIR ELECTRICAL EQUIPMENT, LIGHTS, FIXTURES ETC. IN CARGO HOLD NUMBER_x001C_ 05.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Electrical
Issued 27 May 1993 Resolved
REMOVE THE TYPE "SO" CABLES THAT RUN INTO CARGO HOLD 05, DOWN THE STAIRCASEINTO THE HOLD. REPLACE CABLES WITH APPROVED TYPE ACCEPTED BY LLOYDS AND _x001C_ INSTALL WITH CORRECT WIRING METHOD.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Fire Fighting
Issued 27 May 1993 Resolved
PLEASE PROVIDE INFORMATION RELATING TO THE NEWLY INSTALLED VERTICAL DROP_x001C_ DOORS INSTALLED IN FAN ROOM DOORS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Lifesaving
Issued 27 May 1993 Resolved
LOWER ALL STARBOARD SIDE LIFEBOATS IN THE PRESENCE OF A USCG MARINE INSPECTOR OR SATISFY THE OFFICER IN CHARGE, MARINE INSPECTION, JACKSONVILLEFLORIDA.
Condition: Unknown
Due 27 May 1993
Resolved 27 May 1993
Electrical
Issued 3 December 1992 Resolved
PROVIDE EMERGENCY LIGHTING IN CREW GALLEY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 3 December 1992
Resolved 3 December 1992
Electrical
Issued 4 June 1992 Resolved
PROVIDE A HORIZONTAL PROTECTION BAR OR DEVICE ACCROSS THE FACE OF THE _x001C_ ANCHOR WINDLASS ELECTRICAL BOARD AND INSTALL DIE ELECTRIC MATING. _x001C_ CHAP II REG 23 (a) (ii) SOLAS 60 _x001C_ _x001C_
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Fire Fighting
Issued 4 June 1992 Resolved
PROVIDE STEEL DOORS MEETING BULKHEAD CLASSIFICATIONS FOR FAN ROOMS NUMBERS_x001C_11, 12, 13,AND 15. MUST BE INSTALLED IN ACCORDANCE WITH LLOYDS RULES._x001C_ ALL OTHER DOORS OF SIMILIAR DESIGN SHALL BE ADDRESSED AS WELL. _x001C_ CHAP II REG 38 (d) SOLAS 60._x001C_
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Electrical
Issued 4 June 1992 Resolved
INSTALL GLOBES AND GUARDS ON LIGHT BULBS WERE NEEDED IN FAN ROOMS. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Electrical
Issued 4 June 1992 Resolved
INSTALL COVER ON LARGE DISTRIBUTION PANEL BOX IN SWITCHBOARD "G" ROOM._x001C_ GALLEY AREA. CHAP II REG 23 (a) (ii) SOLAS 60._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Electrical
Issued 4 June 1992 Resolved
INSTALL NEW CABLE MEETING LLOYDS ACCEPTED STANDARD, IEEE-45, TO REPLACE_x001C_ THE TYPE "S" CALBE SEEN NEWLY INSTALLED IN THE "G" DISTRIBUTION ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 June 1992
Resolved 4 June 1992
Electrical
Issued 12 March 1992 Resolved
REMOVE JURY RIG WIRE IN THE GALLEY DEEP FAT FRYER CONTROL TO OVERHEAD LIGHTSOLAS 60, CHAP I, REG 11
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Construction/Loadline
Issued 12 March 1992 Resolved
CORRECT "A" CLASS BULKHEAD WIRE PENETRATION AS PER CLASSIFICATION SOCIETY RULES AT FIRE DOOR B1 AFT OF WATERTIGHT DOOR 24, CABLES SHOULD BE SUPPORTEDPROPERLY BETWEEN WTD 24 AND FIREDOOR B1. _x001C_ SOLAS 60, CHAP II, REG 38(a)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Construction/Loadline
Issued 12 March 1992 Resolved
SHOW APPROVAL FOR THE NEW HATCH ABOVE THE LAUNDRY AT THE LAUNDRY ESCAPE. _x001C_SOLAS 60, CHAP I, REG 11
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Construction/Loadline
Issued 12 March 1992 Resolved
REPAIR DAWGS ON WATERTIGHT HATCH LOCATED ON THE MOORING DECK AFT. _x001C_ SOLAS 60, CHAP II, REG 16 OR 17
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Accommodation/Occupational Safety
Issued 12 March 1992 Resolved
REMOVE LOCK HASP FROM EMERGENCY ESCAPE TUNNEL FROM ENGINE ROOM SHAFT ALLEY (LOCATION MAIN DECK AFT). SOLAS 60, CHAP II, REG 68(a)(ii)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Fire Fighting
Issued 12 March 1992 Resolved
REPLACE CO2 EXTINGUISHER EH6 ENGINEROOM. _x001C_ SOLAS 60, CHAP II, REG 57(d)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Fire Fighting
Issued 12 March 1992 Resolved
INSURE ALL INTERIOR FIRE HOSES ARE CONNECTED TO HYDRANT. _x001C_ SOLAS 60, CHAP II, REG 56(f) & 66
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Fire Fighting
Issued 12 March 1992 Resolved
REPLACE GASKET/SEALS BETWEEN ELEVATOR DOORS SUN DECK FORWARD CENTER, UPPER DECK AFT. SOLAS 60, CHAP II, REG 43(a)(b)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Fire Fighting
Issued 12 March 1992 Resolved
ADJUST FIRE SCREEN DOORS AT M-17 AND RELAMP THE LADDER TO BELOW DECK. _x001C_ SOLAS 60, CHAP II, REG 25(b) & 38(d)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
STOW ALL OXYGEN BOTTLES IAW SOLAS RULES.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Navigation
Issued 12 March 1992 Resolved
REPAIR OR REPLACE INOP SPEED LOG INDICATOR ON THE BRIDGE. _x001C_ SOLAS 60, CHAP I, REG 11
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992 Resolved
RELAMP EMERGENCY LIGHT STARBOARD SIDE-CHILDS PLAYROOM _x001C_ SOLAS 60, CHAP II, REG 25(b)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
INSTALL TWO THREADED DRAIN PLUGS WITH CHAINS IN #1 AND #2 LIFEBOATS. ENSURE ALL OTHER BOAT PLUGS ARE LOCKED WITH CHAINS. _x001C_ SOLAS 60, CHAP III, REG 11(a)(ii)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
REPLACE INSTALLED RADIO IN #10 LIFEBOAT. _x001C_ SOLAS 60, CHAP III, REG 14(a)(ii)(d)(e)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992 Resolved
REPLACE COVERS AS NECESSARY ON JUNCTION BOXES IN FAN ROOMS ALONG THE BOAT _x001C_DECK. SOLAS 60, CHAP II, REG 27(a)(i)(1)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
REPLACE WEATHER SEALING TAPE AROUND LIFERAFT CONTAINERS #1 & 19. _x001C_ SOLAS 60, CHAP III, REG 15(g)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
REPAIR OR REPLACE DAMAGED LIFERAFT CONTAINERS #3,7,9A & 11A. _x001C_ SOLAS 60, CHAP III, REG 15(g)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992 Resolved
REPLACE/INSTALL MISSING LIGHT COVERS ON ALL FLORESENT LIGHT FIXTURES. _x001C_ SOLAS 60, CHAP I, REG 11
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
REMOVE UNSECURED NITROGEN & FREON BOTTLES FROM THE COMPRESSOR ROOM OPPOSITETHE CREWS MESS SERVICE LINE.
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
REPAIR/REPLACE SEARCHLIGHT IN #9 LIFEBOAT. _x001C_ SOLAS 60, CHAP III, REG 14(f)(g)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Fire Fighting
Issued 12 March 1992 Resolved
REPLACE FIRE NOZZLE AT STATION EB 1. _x001C_ SOLAS 60, CHAP II, REG 56(f)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Fire Fighting
Issued 12 March 1992 Resolved
REPLACE COVER PLATE ON CARGO ELEVATOR MAIN DECK AND E DECK. _x001C_ SOLAS 60, CHAP II, REG 38(d)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Accommodation/Occupational Safety
Issued 12 March 1992 Resolved
DEAD END CORRIDOR ON AFT STBD RIVIERA DECK - IDENTIFY CONVERSION DATE OF THIS AREA AND PROVIDE PROOF THAT 50 FT CORRIDOR ACCEPTED BY FLAG STATE._x001C_ (SOLAS 74,REG II/21.A.iii LIMITS DEAD-END CORRIDORS TO 43 FT.)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Accommodation/Occupational Safety
Issued 12 March 1992 Resolved
WINE SHOP IN AFT STAIRWAY, MAIN DECK. PROVIDE DATE OF INSTALLATION OF WINESHOP AND PROOF THAT ARRGT MEETS RULES IN EFFECT AT TIME OF INSTALLATION._x001C_ (SOLAS 48, REG II/33.b)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Accommodation/Occupational Safety
Issued 12 March 1992 Resolved
FAN ROOM IN STAIRTOWER ON UPPER DECK - INSTALL A CLASS DOOR IN PLACE OF WOODEN DOOR._x001C_ (SOLAS 48, REG.II/26.k AND REG.II/25.b)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Lifesaving
Issued 12 March 1992 Resolved
REPAIR AUDIBLE WARNING ALARM ON WATERTIGHT DOOR #24. _x001C_ SOLAS 60, CHAP II, REG 13(i)(i)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992 Resolved
REMOVE TEMPORARY PLASTIC TIE WRAPS FROM HORIZONAL ELECTRIC CABLE RUNS IN _x001C_ THE LAUNDRY. INSTALL STAINLESS STEEL WRAPS AS PER CLASSIFICATION SOCIETY_x001C_ RULES. SOLAS 60, CHAP II, REG 27(a)(vi)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Electrical
Issued 12 March 1992 Resolved
REPLACE PLASTIC TIE WRAPS ON CABLE RUNS ABOVE WATERTIGHT DOOR #24 WITH _x001C_ STAINLESS STEEL WRAPS. SOLAS 60, CHAP II, REG 27(a)(vi)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Construction/Loadline
Issued 12 March 1992 Resolved
CORRECT WIRING PENETRATIONS THOUGH WATERTIGHT BULKHEADS AT WATERTIGHT DOOR_x001C_#24 IAW LLOYD'S RULES. SOLAS 60, CHAP II, REG 13(b)
Condition: Unknown
Due 12 March 1992
Resolved 12 March 1992
Construction/Loadline
Issued 5 December 1991 Resolved
MAKE ALL WIRING PENETRATIONS ABOVE WATERTIGHT DOOR #2 WATERTIGHT IAW CLASSIFICATION SOCIETY RULES.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Construction/Loadline
Issued 5 December 1991 Resolved
MAKE ALL PENETRATIONS ABOVE WATERTIGHT DOOR #1 WATERTIGHT IAW CLASSIFICATION SOCIETY RULES._x001C_
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Fire Fighting
Issued 5 December 1991 Resolved
WELD SLUG INSTALLED ABOVE FIRE DOOR TO BOILER ROOM (ITEM FROM SEPT 91 EXAMINATION. SLUG IS WELDED ON ONE SIDE).
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Navigation
Issued 5 December 1991 Resolved
PROVIDE CURRENT EDITIONS OF COAST PILOTS VOL 2,4, AND 5 AND TIDAL CURRENT TABLES.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Construction/Loadline
Issued 5 December 1991 Resolved
MAKE PERMANENT REPAIRS TO LEAKING PORT SIDE FRESH WATER TANK FORWARD BULKHEAD.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Construction/Loadline
Issued 5 December 1991 Resolved
INSTALL WATERTIGHT HATCH WITH COUNTERWEIGHT AND LATCHING DEVICE AT THE PRESENT EMERGENCY ESCAPE HATCH ON THE RIVERIA DECK AT WATERTIGHT DOOR #11 IAW CLASS SOCIETY.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Construction/Loadline
Issued 5 December 1991 Resolved
REPAIR BULKHEADS AND RESTOW LEAD BALLAST IN #2 HOLD.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Electrical
Issued 5 December 1991 Resolved
REMOVE PORTABLE ELECTRIC CORD FROM THE LAUNDRY ESCAPE HATCH TO THE DECK ABOVE.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Lifesaving
Issued 5 December 1991 Resolved
INSTALL COUNTERWEIGHT ON LAUNDRY ROOM ESCAPE HATCH.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Electrical
Issued 5 December 1991 Resolved
INSTALL COVER ON OPEN JUNCTION BOX NEXT TO CO2 STATION H2, MOUNT SAME.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Electrical
Issued 5 December 1991 Resolved
INSTALL BLANKS IN POWER PANEL IN LAUNDRY.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Electrical
Issued 5 December 1991 Resolved
MARK EMERGENCY LIGHTS WITH RED "E" AS NECESSARY.
Condition: Unknown
Due 5 December 1991
Resolved 5 December 1991
Lifesaving
Issued 19 September 1991 Resolved
MARK VESSEL NAME CLEARLY ON ALL LIFEJACKETS INSIDE AND OUTSIDE.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Lifesaving
Issued 19 September 1991 Resolved
REPLACE MISSING LIGHTS ON LIFEJACKETS AND ENSURE CREW IS TRAINED ON DONNINGAND ADJUSTING OF LIFEJACKETS. (ADJUSTING STRAPS SHOULD BE FREE OF KNOTS.)
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Engineering
Issued 19 September 1991 Resolved
REPAIR LEAKING COOLING WATER PIPING FOR STARBOARD SHAFT BEARING COOLING (SHAFT ALLEY).
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Unknown
Issued 19 September 1991 Resolved
REMOVE OPEN PAINT CANS FROM SHAFT ALLEY.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Fire Fighting
Issued 19 September 1991 Resolved
REPAIR HOLE IN CLASS A ENGINEROOM BULKHEAD ABOVE FIRE DOOR R8.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Lifesaving
Issued 19 September 1991 Resolved
REPLACE ALL (3) LIFEFLOATS. (NO PADDLES, BAD NETTING, NO MARKING, PAINT ORANGE, NO REFLECTIVE TAPE.)
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Lifesaving
Issued 19 September 1991 Resolved
MARK DATE BATTERIES MUST BE REPLACED ON NEW EPIRB. ALSO MARK VESSEL'S NAMEON EPIRB.
Condition: Unknown
Due 19 September 1991
Resolved 19 September 1991
Accommodation/Occupational Safety
Issued 21 June 1990 Resolved
CLEAN LINT FROM BEHIND LAUNDRY DRYERS, ALSO REPAIR DRYER DUCTS.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Accommodation/Occupational Safety
Issued 21 June 1990 Resolved
REQUEST COAST GUARD INSPECTOR BE PRESENT WHEN LAUNDRY AND GALLEY VENTS ARE OPENNED FOR CLEANING.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 21 June 1990 Resolved
CONTINUE WORK ON THE REPLACEMENT OF CREWS LIFEJACKETS NEEDING THE NAME OF VESSEL, RETRO REFLECTIVE TAPE AND MISSING BUCKLES ON STRAPES.
Condition: Unknown
Due 21 June 1990
Resolved 21 June 1990
Lifesaving
Issued 29 March 1990 Resolved
ENSURE ALL VESSEL LIFE PRESERVERS ARE MARKED WITH THE VESSELS NAME, HAVE THE REQUIRED REFLECTIVE MATERIAL AND WHISTLES.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990

Ownership record