LEVENTISA

LEVENTISA is a 1972 freight ship. The Coast Guard has recorded 57 inspections since 1984, most recently in February 2024, along with 153 deficiencies and 6 operational controls.

Records from 1984 to 2024. Most recent: inspection, 29 February 2024.

Built
1972
Last inspected
29 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7210240 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
223828
Flag
CYPRUS
—
Maury page id
psix-223828

Inspections, by type

…with no type recorded47
Years with a record 21 calendar years (1984–2024)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1701 - Regulatory (Subpart C or D), Gross Ton
919 - Regulatory (Subpart C or D), Net Ton
3003 - Dead Weight, Ton
4066 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LIBERTY SPIRIT Freight Ship · MISLE 265787 · 7 January 2000 · activity 90746

Inspection history · 57

29 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872095
30 October 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1938889
27 October 2003 Re-Inspection · Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1937176
11 August 2003 Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1873365
3 November 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1700273
23 October 2002 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1694698
23 September 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1679281
10 June 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1630550
10 June 2002 Security Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1630554
8 May 2002 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1614444
2 April 2002 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1600940
3 January 2002 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1475189
15 December 2001 Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1473742
15 December 2001 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1481488
21 October 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 294626
8 October 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294513
30 July 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 280382
1 June 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278524
31 March 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275904
7 January 2000 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 90746
18 October 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 434163
30 March 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 427075
10 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425706
8 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 21915
29 July 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 418523
28 October 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 409300
23 August 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 409067
13 June 1997 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 404496
30 August 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 394961
20 May 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 391409
18 February 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 388343
20 December 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 386073
30 October 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 694896
25 October 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 384297
4 April 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 376763
18 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 371603
18 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176803
11 May 1994 Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 859876
25 July 1993 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 359814
6 May 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 358165
4 March 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 459339
24 July 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 352087
2 March 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 447570
20 August 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 345474
19 November 1990 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 518974
28 April 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1219679
27 April 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 336819
6 September 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 332460
11 June 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 330917
6 May 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 330237
7 January 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 537220
6 July 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 324410
8 July 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 317214
27 June 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 309800
3 July 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 303044
23 April 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 475008
7 September 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 297861

Deficiency record · 153

Operations/Management › Vessel Safety Management
Issued 27 October 2003 Resolved
Master failed to implement and maintain a properly functioning SMS system. To be addressed prior to departure during external ISM audit. LEGACY COMPONENT DESC: Master''''s Responsiblity/Authority
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Class conducted audit noting 3 non-conformities. Vsl cleared.
Operations/Management › Vessel Safety Management
Issued 27 October 2003 Resolved
Company failed to ensure vessel was properly manned with qualified and certificated seafarers in accordance with national and international requirements. To be addressed during external ISM audit. LEGACY COMPONENT DESC: Company Responsibilities/Authority
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared by Class during ISM audit.
Operations/Management › Vessel Safety Management
Issued 27 October 2003 Resolved
Company failed to take appropriate corrective action in dealing with maintenance on board vessel. To be addressed during external ISM audit. LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared by class during ISM audit.
Personnel › Manning/Qualifications
Issued 27 October 2003 Resolved
Vessel not manned in accordance with minimum safe manning certificate. Chief engineers national license is referenced incorrectly, OS does not have STCW 78/95 application to panama license, AB does not have 95 endorsement to Panama license. To be addressed by attending class society. LEGACY COMPONENT DESC: Minimum Safe Manning
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Engineering › Diesel Engine (propulsion-electric)
Issued 27 October 2003 Resolved
Port and starboard generators have fuel leaks. Fuel leaks cause oil to be discharged into waterway through the cooling system overboard. Fuel lines need to be replaced with new lines. To be addressed by class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Fire Fighting › Fire Main
Issued 27 October 2003 Resolved
Aux fire pump manifold tie in pipe holed and wasted. To be addressed by class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Engineering › Sea-water System (primary cooling)
Issued 27 October 2003 Resolved
Seawater cooling pipe for port generator holed and leaking. To be addressed by class. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Documentation › Safety/Response Plans/Programs
Issued 27 October 2003 Resolved
SOPEP not endorsed or updated with correct owner and operator. To be addressed by class. LEGACY COMPONENT DESC: SOPEP
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Fire Fighting › Firemans Outfit
Issued 27 October 2003 Resolved
Protective coating is missing on firemans outfit. To be addressed by class. LEGACY COMPONENT DESC: Protective Clothing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Engineering › Sea-water System (primary cooling)
Issued 27 October 2003 Resolved
Starboard generator s/w cooling end pipe wasted and leaking. To be addressed by class. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Lifesaving › Lifebuoys
Issued 27 October 2003 Resolved
Three lifebuoys are cracked and wasted, need to be replaced. To be addressed by class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Engineering › Sea-water System (primary cooling)
Issued 27 October 2003 Resolved
Generator cooling system is discharging oil. Generators are not to be run until repairs are made. To be addressed by class. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class.
Operations/Management › Port and Waterways Safety
Issued 27 October 2003 Resolved
Vessel failed to report hazardous condition. The starboard generator was out of service prior to entry due to high pressure fuel leak. LEGACY COMPONENT DESC: Notice of Hazardous Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 November 2003
Resolution: Cleared to the satisfaction of Class. Pursuing Civil Penalty.
Operations/Management › Drills/Instruction
Issued 11 August 2003 Resolved
Practice all emergency drills to the point of efficiency that can be displayed at next U.S. port LEGACY COMPONENT DESC: Fire
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 27 October 2003
Operations/Management › Drills/Instruction
Issued 11 August 2003 Resolved
Practice all emergency drills to the point of efficiency that can be displayed at next U.S. port. LEGACY COMPONENT DESC: Abandon Ship
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 27 October 2003
Documentation › Manuals/Policy Documentation
Issued 11 August 2003 Resolved
Amend SOPEP, to the satisfaction of certificate issuing authority, to include local contacts for all ports visited by vessel. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 27 October 2003
Engineering › Steering Gear System
Issued 11 August 2003 Resolved
Make repairs to steering gear rudder post bearing and bushings to the satisfaction of certificate issuing authority prior to next U.S. port. LEGACY COMPONENT DESC: Rudder Bearing
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 October 2003
Documentation › Safety Management System
Issued 11 August 2003 Resolved
Identify location of International Shore Connection on Fire Control Plan to the satisfaction of Certificate Issuing Authority prior to next U.S. port. LEGACY COMPONENT DESC: Key Shipboard Operations Plans/Instructions
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 27 October 2003
Navigation › Piloting/Steering
Issued 11 August 2003 Resolved
Repair magnetic compass light prior to next U.S. port. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 27 October 2003
Personnel › Certificates/Documents/Licenses
Issued 23 October 2002 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 November 2002
Engineering › Generator (propulsion-electric)
Issued 23 October 2002 Resolved
PORT AND STARBOARD MAIN GENERATORS HAD VARIOUS LEAKS ON THE DIESEL AND LUBE OIL SUPPLY AND RETURN LINES. TEMPORARY REPAIRS AUTHORIZED UNTIL 11/25/02 WHEN REPAIRS MUST BE MADE PERMANENT.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2002
Resolved 7 August 2003
Fire Fighting › Fire Main
Issued 23 October 2002 Resolved
VARIOUS AREAS OF FIRE MAIN INOP. DUE TO ONGOING PIPE REPAIR AT TIME OF BOARDING. INSPECTION OF FIRE MAIN WILL OCCUR DURING ADDITIONAL FIRE DRILL. LEGACY COMPONENT DESC: Condition
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 October 2002
Resolved 3 November 2002
Resolution: Fire main tested satisfactorily by attending CG MI.
Operations/Management › Drills/Instruction
Issued 23 October 2002 Resolved
FAILED TO PERFORM BOTH FIRE AND ABANDON SHIP DRILLS ADEQUATELY OR COMPETENTLY. LEGACY COMPONENT DESC: Abandon Ship And Fire Drill
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2002
Resolved 3 November 2002
Resolution: Abandon ship and fire drills performed to satisfaction of attending CG MI
Operations/Management › Vessel Safety Management
Issued 23 October 2002 Resolved
CREW WAS NOT TRAINED ON THE VESSEL'S SAFETY MANAGEMENT SYSTEM MANUALS, AND WERE KEEPING INADEQUATE MAINTENANCE RECORDS FOR THE VESSEL. VSL ORDERED OUT OF US WATERS UNTIL SMS FULLY IMPLEMENTED: SEE MISLE ACTIVITY NO. 1700273. LEGACY COMPONENT DESC: Resources and Personnel
Action required: 15 - Rectify deficiencies by next port
Due 23 October 2002
Resolved 7 August 2003
Construction/Loadline › Hull
Issued 23 October 2002 Resolved
DOUBLER IN UPPER ENGINE ROOM ON STARBOARD SIDE FORWARD ON THE SIDESHELL NOT REPAIRED/REPLACED IAW CLASS REQUIREMENTS LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 10 November 2002
Resolved 7 August 2003
Lifesaving › Lifeboat
Issued 23 September 2002 Resolved
Port life boat rudder wasted and broken. Make permanent and proper repairs to the satisfaction of R.O. issuing the Safety Equipment Certificate (IBS) prior to departing Port Everglades
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 3 October 2002
Resolution: Cleared on Board, CHK/Miams
Lifesaving › Lifeboat
Issued 23 September 2002 Resolved
Port life boat mast mount and mast top wasted and broken. Make permanent and proper repairs to the satisfaction of (IBS) prior to departing Port Everglades.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 3 October 2002
Resolution: Cleared on Board, CHK/Miams
Lifesaving › Inflatable Liferafts
Issued 23 September 2002 Resolved
Provide port life raft in accordance with SOLAS CHPIII/26. Vsl does not meet III/26.1.3.2 for single raft. Have additional life raft on board and approved by R.O. issuing the Safety Equipment Certificate (IBS) .
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 2 October 2002
Resolution: Concerning the liferaft; it was found that SOLAS Reg 26 is not an all Ship Site and that 1983 amendments call for only 26.3 to be applied which is a 100% liferaft, but not on either side, that does not come into effect until 01JUL86, therefore the arrang
Documentation › Certificates/Documents
Issued 23 September 2002 Resolved
Safety equipment certificate not valid due to missing raft. Have IBS survey life rafts, life boats and issue new certificate as appropriate, prior to departing the port. LEGACY COMPONENT DESC: Cargo Ship Safety Equipment Certificate
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 2 October 2002
Resolution: Concerning the liferaft; it was found that SOLAS Reg 26 is not an all Ship Site and that 1983 amendments call for only 26.3 to be applied which is a 100% liferaft, but not on either side, that does not come into effect until 01JUL86, therefore the arrang
Documentation › Safety Management System
Issued 23 September 2002 Resolved
Provide crew with proper safety equipment and clothing in accordance with the vessels SMS prior to conducting operations or sailing.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 2 October 2002
Resolution: Cleared on Board, CHK/MIAMS
Communications › Radio Communications
Issued 23 September 2002 Resolved
Provide a registered 406 EPRIB on bridge prior to departing to the satisfaction of the R.O. issuing the Radio Certificate (IBS). LEGACY COMPONENT DESC: EPIRB
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 2 October 2002
Resolution: Cleared on board, CHK/MIAMS
Communications › Radio Communications
Issued 23 September 2002 Resolved
Make permanent and proper repairs to the GMDSS. Repairs must be completed by approved GMDSS maintenance service company and approved by IBS. LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 2 October 2002
Resolution: Cleared on board, CHK/MIAMS
Navigation › Piloting/Steering
Issued 23 September 2002 Resolved
Make permanent and proper repairs to the gyro magnetic compass to the satisfaction of USCG prior to departing Port Everglades LEGACY COMPONENT DESC: Gryo Compass Repeater
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 2 October 2002
Resolution: Cleared on board. CHK/MIAMS
Documentation › Safety Management System
Issued 23 September 2002 Resolved
Due to the number of major deficiencies, the lack of maintenance and overall poor condition of the safety equipment. The Vsl's ISM documents and SMS are in question. Have ISM R.O. (ABS) conduct a full external audit prior to departing the port LEGACY COMPONENT DESC: Conformity Maintenance Procedures
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 2 October 2002
Resolution: As far as the ISM audit required, the vessel is on an "Interim DOC & ISM" and therefore, an audit is not appropriate according to the code. This brought into question the legitimacy of the company being new. See Narr.
Operations/Management › Port and Waterways Safety
Issued 23 September 2002 Resolved
The vessel is here-by detained under SOLAS CHP I/19. The vessel is not to move from berth without further permission of the Captain of the Port Miami.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 September 2002
Resolved 3 October 2002
Resolution: Cleared on Board, CHK/Miams
Documentation › Certificates/Documents
Issued 23 September 2002 Resolved
Complete a full U.S. Coast Guard exam with drills prior to departing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2002
Resolved 3 October 2002
Resolution: Cleared on Board, CHK/Miams
Engineering › Diesel Engine (propulsion-direct drive)
Issued 23 September 2002 Resolved
Main engine salt water cooling pipe wasted and holed. Repair to satisfaction of class, prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2002
Resolution: Cleared on Board, CHK/Miams
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 23 September 2002 Resolved
Salt water piping to lube oil cooling on both generators wasted/holed and leaking, Repair to satisfaction of class, prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2002
Resolution: Cleared on Board, CHK/Miams
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 23 September 2002 Resolved
Salt water jacket cover on ship generator generators wasted/holed and leaking, Repair to satisfaction of class, prior to sailing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 October 2002
Resolution: Cleared on Board, CHK/Miams
Documentation › Certificates/Documents
Issued 23 September 2002 Resolved
COFR not valid, still has old companies name on the certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 February 2024
Resolution: Verified via phone, CHK/Miams
Documentation › Certificates/Documents
Issued 23 September 2002 Resolved
Provide valid load line certificate at next U.S. port. Vessel is currently on a provisional Load Line due to expire 06OCT02. LEGACY COMPONENT DESC: Coastwise Load Line Certificate
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 23 October 2002
Resolution: PERMANENT LOADLINE CERTIFICATE PROVIDED BY CLASS.
Fire Fighting › Miscellaneous Items
Issued 23 September 2002 Resolved
Provide communications for fire parties and prove proper operations at next U.S. Port.
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 23 October 2002
Resolution: VESSEL NOW HAS 4 WALKIE TALKIES IN ADDITION TO THE 2 WALKIE TALKIES PROVIDED FOR DRILLS.
Personnel › Certificates/Documents/Licenses
Issued 23 September 2002 Resolved
Provide original licenses and endorsements, no copies , at next U.S. port.
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 23 October 2002
Resolution: CREW AND OFFICERS HAVE ORIGINAL LICENSE OR APPLICATION PAPERS.
Documentation › Certificates/Documents
Issued 23 September 2002 Resolved
Provide original COFR at next US Port. (COFR verified via phone only in Miami). LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 23 October 2002
Resolution: ORIGINAL COFR IS VALID AND ON BOARD.
Construction/Loadline › Hull
Issued 23 September 2002 Resolved
Prove permanent and proper repairs to all class items or provide condition of class at the next US Port. Load Line Survey in progress.
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 3 November 2002
Resolution: Class report clearing items submitted to MSO Savannah MI''s.
Lifesaving › Buoyant Smoke Signals
Issued 23 September 2002 Resolved
Provide quick release life ring on bridge wings at next US Port.
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 23 October 2002
Resolution: PORT AND STARBOARD QUICK RELEASES, LIFE RINGS, AND SIGNALS WERE PROVIDED AND TO THE SATISFACTION OF COAST GUARD.
Lifesaving
Issued 23 September 2002 Resolved
Provide proof or all IBS Work Items completed at next US Port.
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 3 November 2002
Resolution: Class report clearing all items issued to MSO Savannah MI''s.
Deck/Cargo › Cargo Transfer (solid)
Issued 23 September 2002 Resolved
Provide condition of class or make permanent repairs to FWD Boom Cradle, wasted and cracked welds, at next US Port.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 23 October 2002
Resolution: BOOM CRADLE WAS REPAIRED WITH ALL NEW METAL AND TO SATIFACTION OF COAST GUARD.
Communications › Radio Communications
Issued 23 September 2002 Resolved
Prove proper operation of all GMDSS equipment in accordance with the Radio Certificate. LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2002
Resolved 23 October 2002
Resolution: [name withheld] USE OF GMDSS SYSTEM, AND PROVIDED A MERICOM TECH REPORT VALIDATING REPAIRS TO GMDSS.
Fire Fighting
Issued 21 October 2001 Resolved
0750 Vessel has changed out half of the crew. Crew is to train for the fireand abandon ship drills until all crew is proficient with the equipment andits location.
Condition: Unknown
Due 31 October 2001
Resolved 3 January 2002
Resolution: Cleared satisfactorily.
Fire Fighting
Issued 21 October 2001 Resolved
0735 Vessels SCBA bottles are half full on one and empty on the other. (SOLAS 74A17/1.2) Refill both bottles prior to depature.
Condition: Unknown
Due 21 October 2001
Resolved 30 October 2001
Lifesaving
Issued 8 October 2001 Resolved
BOTH LIFEBOATS MISSING BOWSING TACKEL. REPLACE PRIOR TO NEXT US PORT.
Condition: Unknown
Due 22 October 2001
Resolved 22 October 2001
Lifesaving
Issued 8 October 2001 Resolved
LIFE RAFT STRAP ATACHMENT (PAD EYE) WASTED. REPLACE PRIOR TO DEPARTING THEPORT.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Navigation
Issued 8 October 2001 Resolved
COMPASS NOT CALIBRATED AFTER MAJOR STEEL WORK IN YARD. PROVIDE CURRENT DEVIATION CARD PRIOR TO NEXT US PORT.
Condition: Unknown
Due 22 October 2001
Resolved 22 October 2001
Lifesaving
Issued 8 October 2001 Resolved
HOOKS ON PORT LIFEBOAT WASTED. REPLACE PRIOR TO DEPARTING THE PORT.
Condition: Unknown
Due 8 October 2001
Resolved 9 October 2001
Lifesaving
Issued 8 October 2001 Resolved
STBD BRIDGE LIFE RING IS THE WRONG WEIGHT. REPLACE PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Electrical
Issued 8 October 2001 Resolved
ELECTRICAL PANEL IN PASSAGEWAY AFT OF GALLEY MISSING FACE PLATE. REPLACE TO THE SATTISFACTION OF USCG.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Lifesaving
Issued 8 October 2001 Resolved
ABANDON SHIP LADDER ON THE PORT SIDE NOT PROPERLY AFFIXED TO THE VESSEL. MOUNT PROPERLY TP THE SATISFACTION OF USCG.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Electrical
Issued 8 October 2001 Resolved
ELECTRICAL PLUG HANGING LOOSE ABOVE COOLER IN THE GALLEY. MOUNT AND REPAIRWIRING TO THE SATISFACTION OF USCG.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Lifesaving
Issued 8 October 2001 Resolved
DRILLS NOT SATISFACTORY. PERFORM FIRE AND BOAT DRILLS TO THE SATISFACTION OF USCG PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Deck/Cargo
Issued 8 October 2001 Resolved
HAWSE PIPE GUARD MISSING. REPLACE GUARD TO THE SATISFACTION OF USCG.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Construction/Loadline
Issued 8 October 2001 Resolved
NAVTEX RECORDER OUT OF PAPER. REPLACE PAPER PRIOR TO DEPARTING THE PORT.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Navigation
Issued 8 October 2001 Resolved
PROVIDE ALL MISSING PUBS ON THE BRIDGE. REPLACE PRIOR TO DEPARTING THE PORT.
Condition: Unknown
Due 9 October 2001
Resolved 10 October 2001
Documentation
Issued 30 July 2000 Resolved
VESSEL'S LAST PORT WAS IN THE CARRIBEAN (DR) AND VESSEL ONLY HELD A SAFE MANNING DOCUMENT FOR 600 MILE VOYAGES.
Condition: Unknown
Due 30 July 2000
Resolved 3 August 2000
Engineering
Issued 30 July 2000 Resolved
Main engine rear oil seals leaking.
Condition: Unknown
Due 30 August 2000
Resolved 10 August 2000
Documentation
Issued 30 July 2000 Resolved
THIRD OFFICER COULD NOT PRODUCE ANY LICENSE.
Condition: Unknown
Due 30 July 2000
Resolved 10 August 2000
Construction/Loadline
Issued 30 July 2000 Resolved
VESSEL'S HATCH COVER LIFTING PINS AND LINKS ARE WASTED.
Condition: Unknown
Due 30 July 2000
Resolved 10 August 2000
Deck/Cargo
Issued 1 June 2000 Resolved
FWD CRANE HOLED AND WASTED AT PORT SIDE OF BOOM PIVOT
Condition: Unknown
Due 2 June 2000
Resolved 2 June 2000
Deck/Cargo
Issued 1 June 2000 Resolved
AFT CRANE STOPS WASTED AND PULLING FROM DECK
Condition: Unknown
Due 2 June 2000
Resolved 2 June 2000
Construction/Loadline
Issued 31 March 2000 Resolved
ACCESS HATCH TO CRANE (DECK) WASTED. REPAIR PRIOR TO 30APR00
Condition: Unknown
Due 4 August 2000
Resolved 4 August 2000
Electrical
Issued 31 March 2000 Resolved
LIGHT FIXTURE IN CRANE ACCESS MISSING COVER. REPAIR PRIOR TO 30APR00.
Condition: Unknown
Due 4 August 2000
Resolved 4 August 2000
Electrical
Issued 31 March 2000 Resolved
AUXILLARY GENERATORS MISSING BELT GUARDS. REPAIR PRIOR TO 30APR00.
Condition: Unknown
Due 4 August 2000
Resolved 4 August 2000
Electrical
Issued 31 March 2000 Resolved
#2 MAIN GENERATOR LOCAL TACHOMETER IS INOPERABLE. REPAIR PRIOR TO 30APR00
Condition: Unknown
Due 4 August 2000
Resolved 4 August 2000
Fire Fighting
Issued 31 March 2000 Resolved
PORTABLE FIRE EXTINGUISHERS NOT SECURED IN BRACKETS. REPAIR PRIOR TO 30APR00
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Navigation
Issued 31 March 2000 Resolved
RUDDER ANGLE INDICATORS UNREADABLE. REPAIR PRIOR TO DEPARTURE OF PORT NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Navigation
Issued 31 March 2000 Resolved
STEERING POWER INDICATING LIGHTS IN PILOT HOUSE INOPERATIVE. REPAIR PRIOR TO DEPARTURE OF PORT NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Electrical
Issued 31 March 2000 Resolved
PORTION OF MAIN SWITCH BOARD MISSING ELECTRICAL MATTING REPAIR PRIOR TO 30APR00.
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Electrical
Issued 31 March 2000 Resolved
SWITCH BOARD INDICATING LIGHTS FOR GENERATORS INOPERABLE REPAIR PRIOR TO 30APR00.
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Electrical
Issued 31 March 2000 Resolved
440V GROUND ON MAIN SWITCH BOARD
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Lifesaving
Issued 31 March 2000 Resolved
STBD LIFEBOAT FORWARD SEAT AND SAIL BOOM BRACKET WASTED REPAIR TO THE SATISFACTION OF ADMINISTRATION PRIOR TO DEPARTURE OF NYCMI.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Lifesaving
Issued 31 March 2000 Resolved
STBD LIFEBOAT BOLT WASTED ON AFT RELEASING GEAR TO HULL FITTING REPAIR TO THE SATISFACTION OF ADMINISTRATION PRIOR TO DEPARTURE OF NYCMI.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Lifesaving
Issued 31 March 2000 Resolved
STBD LIFEBOAT REPLACE RING CONNECTING SEAPAINTER TO HULL REPAIR TO THE SATISFACTION OF ADMINISTRATION PRIOR TO DEPARTURE OF NYCMI.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Documentation
Issued 31 March 2000 Resolved
VSL HAS NO MOTOR LIFEBOATS ON BOARD; NOE LISTED ON THE SATETY EQUIPMENT CERTIFICATE; CONFLICT WITH SOLAS 60 III/8. HAVE ADMINISTRATION ADDRESS THISCONDITION PRIOR TO DEPARTURE. PHONE/FAX REPORT TO USCG.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Documentation
Issued 31 March 2000 Resolved
VSL SAFETY EQUIPMENT CERTIFICATE REQUIRES ONLY 4 LIFEBUOYS; CONFLICTS WITH SOLAS REG III/37. CLEAR TO THE SATISFACTION OF ADMINISTRATION PRIOR TO DEPARTURE OF NYCMI.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Accommodation/Occupational Safety
Issued 31 March 2000 Resolved
EMERGENCY ESCAPE IN ENGINE ROOM NOT LABELED REPAIR PRIOR TO DEPARTIING PORTNYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 11 April 2000
Accommodation/Occupational Safety
Issued 31 March 2000 Resolved
ALL CREW TOILETS INOP REPAIR PRIOR TO DEPARTURE OF NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 31 March 2000 Resolved
INTERNATIONAL SHORE CONNECTION NOT LABELED ON FIRE PLAN REPAIR PRIOR TO 30APR00.
Condition: Unknown
Due 30 April 2000
Resolved 11 April 2000
Accommodation/Occupational Safety
Issued 31 March 2000 Resolved
RAILINGS ON PORT/STBD CENTERLINE BROKEN/BENT REPAIR PRIOR TO DEPARTURE NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 11 April 2000
Lifesaving
Issued 31 March 2000 Resolved
PAINT LOCKER NOT SECURED FOR SEA REPAIR TO DEPARTURE NYCMI.
Condition: Unknown
Due 4 April 2000
Resolved 11 April 2000
Accommodation/Occupational Safety
Issued 31 March 2000 Resolved
INADEQUATE LADDER CAGES TO CRANE OPERATING STATIONS REPAIR TO THE SATISFACTION OF CLASS PRIOR TO 30APR00.
Condition: Unknown
Due 5 April 2000
Resolved 11 April 2000
Lifesaving
Issued 31 March 2000 Resolved
CLEAR DECKS OF ALL DEBRIS AND SECURE EQUIPMENT PRIOR TO DEPARTURE NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 31 March 2000 Resolved
UNABLE TO CONDUCT FIRE/BOAT DRILL. CONDUCT DRILLS TO THE SATISFACTION OF USCG PRIOR TO DEPARTURE OF NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 11 April 2000
Navigation
Issued 31 March 2000 Resolved
VSL MISSING CURRENT CHARTS AND PUBLICATIONS PROVIDE PRIOR TO DEPARTING PORTNYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 11 April 2000
Lifesaving
Issued 31 March 2000 Resolved
PORT SIDE L/B RELEASING GEAR WASTED AT HULL FITTING. RENEW TO THE SATISFACTION OF ADMINISTRATION PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Lifesaving
Issued 31 March 2000 Resolved
LIFBOAT PORTSIDE, REPLACE AFT SEAT AND MAKE REPAIRS TO FWD SEAT BOOM BRACKET. REPAIR TO THE SATISFACTION OF ADMINISTRATION PRIOR TO DEPARTURE.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Lifesaving
Issued 31 March 2000 Resolved
PORT LIFEBOAT RING CONNECTING BLOCK AND TACKLE TO AFT HOOK WASTED.REPAIR TOTHE SATISFACTION ADMINISTRATION PRIOR TO DEPARTURE OF NYCMI
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Lifesaving
Issued 31 March 2000 Resolved
STBD LIFEBOAT FORWARD RELEASING GEAR TO HULL WASTED REPAIR TO THE SATISFACTION OF ADMINISTRATION PRIOR TO DEPARTUE OF NYCMI.
Condition: Unknown
Due 11 April 2000
Resolved 13 April 2000
Electrical
Issued 31 March 2000 Resolved
#2 440V PANEL FEEDER HAS MISSING COVERS REPAIR PRIOR TO DEPARTING NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Lifesaving
Issued 31 March 2000 Resolved
ENGINE ROOM MISSING GUARDRAILS ABOVE STBD MAIN ENGINE REPAIR PRIOR TO DEPARTING NYCMI.
Condition: Unknown
Due 5 April 2000
Resolved 10 April 2000
Documentation
Issued 30 March 1999 Resolved
FIRST OFFICER DOES NOT HAVE ORIGINAL LICENCE.
Condition: Unknown
Due 1 April 1999
Resolved 21 April 1999
Engineering
Issued 10 February 1999 Resolved
COPPER FUEL LINES ON GENERATORS._x001C_ _x001C_ SOLAS 60 REG I/11
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 10 February 1999 Resolved
VACUUM PUMP ON EMERGENCY FIRE PUMP INOP._x001C_ _x001C_ SOLAS 60 REG II/56_x001C_
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Construction/Loadline
Issued 10 February 1999 Resolved
STEERING GEAR DRAIN LEADS DIRECTLY OVERBOARD._x001C_ _x001C_ MARPOL 73/78 REG I/16_x001C_
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Accommodation/Occupational Safety
Issued 10 February 1999 Resolved
SEWAGE TANK WASTED AND LEAKING._x001C_ _x001C_ 33 CFR 159.7
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Construction/Loadline
Issued 10 February 1999 Resolved
WASTED OVERHEADS IN MACH & STEERING SPACE & FWD HATCH ACCESS._x001C_ _x001C_ SOLAS 60 REG I/11_x001C_
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 10 February 1999 Resolved
FIREMAIN PATCHED IN STEERING GEAR SPACE._x001C_ _x001C_ SOLAS 60 REG II/56_x001C_
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Construction/Loadline
Issued 10 February 1999 Resolved
WX DECK AFT HOLD ACCESS AND PORT E/R FAN SPACE ACCESS PATCHED/REPAIRED WITHBONDO._x001C_ _x001C_ ICLL 66
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 23 August 1997 Resolved
MAKE PERMANENT REPAIR TO EMERGENCY FIRE PUMP SUCTION LINE. TO BE COMPLETED WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 1997
Resolved 18 October 1997
Electrical
Issued 23 August 1997 Resolved
REMOVE TEMPORARY WIRING AND HOUSEHOLD FITTING (ELECTRICAL) FROM PAINT LOCKER AND AFTERSTEERING. ONLY APPROVED MARINE TYPE ELECTRICAL FITTINGS SHOULD BE USED. CORRECTIONS TO BE COMPLETED WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 1997
Resolved 18 October 1997
Electrical
Issued 23 August 1997 Resolved
LIGHTING IN PAINT LOCKER NEEDS TO BE EXPLOSION PROOF TYPE. REPAIRS MUST BE COMPLETED WITHIN 30 DAYS.
Condition: Unknown
Due 18 October 1997
Resolved 18 October 1997
Navigation
Issued 23 August 1997 Resolved
STEERING MOTOR FAILURE ALARM INOPERATIVE. MUST BE REPAIRED WITHIN 30 DAYS.
Condition: Unknown
Due 29 October 1997
Resolved 29 October 1997
Construction/Loadline
Issued 23 August 1997 Resolved
PROVIDE CLASS PROPOSAL, WITHIN 30 DAYS, TO CORRECT WASTED HORIZONTALS IN WAY OF FRAME CARGO HOLD #2 PORT SIDE AFT.
Condition: Unknown
Due 18 October 1997
Resolved 18 October 1997
Documentation
Issued 13 June 1997 Resolved
Provide original International Oil Pollution Prevention Certificate attachment form A. (missing)
Condition: Unknown
Due 22 October 1997
Resolved 22 October 1997
Lifesaving
Issued 30 August 1996 Resolved
LIFEBOUYS MISSING RETRO-REFLECTIVE TAPE. (SOLAS 60 CH. III REG 21)
Condition: Unknown
Due 31 August 1996
Resolved 31 August 1996
Lifesaving
Issued 30 August 1996 Resolved
TWO LIFEBOAT OARS WASTED. (SOLAS 60 CH III REG 11)
Condition: Unknown
Due 31 August 1996
Resolved 31 August 1996
Lifesaving
Issued 30 August 1996 Resolved
LIFEBOAT DAVIT BLOCKS ON STBD SIDE EXTREMLY WASTED. (SOLAS 60 CH III REG 36)
Condition: Unknown
Due 31 August 1996
Resolved 31 August 1996
Lifesaving
Issued 20 May 1996 Resolved
PROVIDE THREE ADDITIONAL LIGHTED LIFEBUOYS FOR A TOTAL OF 5 LIGHTED LIFEBUOYS AS PER SOLAS 60 CH III REG 21e.
Condition: Unknown
Due 31 August 1996
Resolved 31 August 1996
Lifesaving
Issued 20 May 1996 Resolved
LOG AND PERFORM ABANDON SHIP DRILLS AND FIREFIGHTING DRILLS AS PER SOLAS 74CH III REG 18.5 PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 31 August 1996
Resolved 31 August 1996
Lifesaving
Issued 20 May 1996 Resolved
PROVIDE AND POST LIFEBOAT LAUNCHING INSTRUCTIONS AS PER SOLAS 74 CH III REG9.2 PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 31 August 1996
Resolved 31 August 1996
Navigation
Issued 20 December 1995 Resolved
PROVE PROPER OPERATION OF TELEPHONE COMMUNICATION BETWEEN BRIDGE AND AFTER STEERING. (INOPERABLE)
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Navigation
Issued 20 December 1995 Resolved
CALIBRATE MAGNETIC COMPASS. (COMPASS OFF 20 DEGREES)
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Fire Fighting
Issued 20 December 1995 Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP. (PRIMING PUMP DISASSEMBLED)(CLASS TO VERIFY)
Condition: Unknown
Due 26 December 1995
Resolved 26 December 1995
Electrical
Issued 20 December 1995 Resolved
MAKE PERMANENT REPAIRS TO JACKET WATER COOLING AND RAW WATER COOLING PIPINGFOR MAIN DIESEL ENGINES AND SHIP GENERATORS. (TEMPORARY REPAIRS)
Condition: Unknown
Due 20 May 1996
Resolved 20 May 1996
Navigation
Issued 25 October 1995 Resolved
Prove proper operation of Echo Depth Sounder. Class Society to verify. 33 CFR 164.35 (h)
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Fire Fighting
Issued 25 October 1995 Resolved
Prove proper operation of the emergency fire pump. Pump will not pick up suction. SOLAS CH II-2 Reg 4 2.3
Condition: Unknown
Due 31 October 1995
Resolved 7 November 1995
Engineering
Issued 25 October 1995 Resolved
Make permanent and proper repairs to fuel line for ship service generators.Presently there are rubber patches on lines located in overhead above generators. SOLAS II-1 Reg 26
Condition: Unknown
Due 31 October 1995
Resolved 7 November 1995
Electrical
Issued 25 October 1995 Resolved
Install proper electrical switches, lamps and outlets in the forward paint locker, currently unprotected lights, no boxes around outlets and switches.SOLAS CH II-1 Reg 45 10
Condition: Unknown
Due 25 November 1995
Resolved 7 November 1995
Fire Fighting
Issued 25 October 1995 Resolved
Make permanent and proper repairs to the fire hydrant, located on the open deck all the way forward. SOLAS CH II-2 Reg 4 6.2
Condition: Unknown
Due 25 November 1995
Resolved 7 November 1995
Lifesaving
Issued 4 April 1995 Resolved
RENEW HYDROSTATIC RELEASE ON SHIPS EPIRB. THE EPIRB WAS MARKED REPLACE MAR95.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Lifesaving
Issued 4 April 1995 Resolved
REPAIR/REPLACE WATER LIGHT ATTACHED TO THE LIFEBUOY ON THE STARBOARD BRIDGEWING.
Condition: Unknown
Due 27 October 1995
Resolved 27 October 1995
Electrical
Issued 18 October 1994 Resolved
VESSEL MISSING PROTECTIVE LIGHT GUARDS THROUGH-OUT SHIP.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Lifesaving
Issued 18 October 1994 Resolved
VESSELS LIGHTS FOR LIFE-RINGS WERE MISSING BATTERIES.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Accommodation/Occupational Safety
Issued 11 May 1994 Resolved
REPAIR OVERBOARD DISCHARGE VALVE TO TYPE III MARINE SANITATION DEVICE.
Condition: Unknown
Due 15 May 1994
Resolved 17 May 1994
Fire Fighting
Issued 11 May 1994 Resolved
PLACE SPANNER WRENCHES AT EACH FIRE STATION PRIOR TO DEPARTING HOUSTON, TX.
Condition: Unknown
Due 18 May 1994
Resolved 13 May 1994
Documentation
Issued 11 May 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 16 May 1994
Resolved 17 May 1994
Fire Fighting
Issued 11 May 1994 Resolved
PROFESSIONALLY SERVICE ALL SELF CONTAINED BREATHING APPARATI PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Fire Fighting
Issued 11 May 1994 Resolved
REPLACE LEAKING FIRE NOZZLE IN FIRE HOSE STATION AFT WEATHERDECK PRIOR TO RETURNING TO A U.S. PORT.
Condition: Unknown
Due 11 May 1994
Resolved 11 May 1994
Navigation
Issued 11 May 1994 Resolved
PRIOR TO DEPARTING PRESENT BERTH AT CITY DOCK # 41, PROVIDE / INSTALL RUDDER ANGLE INDICATOR TO SATISFACTION OF CLASS SOCIETY IN VESSEL'S_x001C_ STEERING GEAR ROOM. SATISFACTORY CLASS REPORT TO BE PROVIDED TO MSO HOUSTONPRIOR TO DEPARTURE.
Condition: Unknown
Due 18 May 1994
Resolved 13 May 1994
Lifesaving
Issued 11 May 1994 Resolved
PRIOR TO DEPARTING PORT, PROPERLY INSTALL WEAK LINK ON LIFE RAFT SEA_x001C_ PAINTER LINE TO LIFE RAFT CRADLE.
Condition: Unknown
Due 16 May 1994
Resolved 12 May 1994
Navigation
Issued 20 August 1991 Resolved
VSL. FAILED TO HAVE PROPER CHARTS ONBOARD FOR AREA TRANSITED_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 July 1993
Resolved 27 July 1993
Accommodation/Occupational Safety
Issued 27 April 1990 Resolved
33CFR159.7(C)(1) IMPROPERLY INSTALLED MSD. AUTH: 33USC1322(B)(1) PENALTY: 33USC1322(J)
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Engineering
Issued 27 April 1990 Resolved
33CFR155.360 INOPERABLE OILY WATER SEPARATOR. AUTH: 33USC1321 PENALTY: 33USC1321
Condition: Unknown
Due 27 April 1990
Resolved 27 April 1990
Documentation
Issued 11 June 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 June 1989
Resolved 11 June 1989
Documentation
Issued 11 June 1989 Resolved
CERTIFICATE OF FINANCIAL RESPONSIBILITY EXPIRED 05JUN89
Condition: Unknown
Due 11 June 1989
Resolved 11 June 1989
Documentation
Issued 11 June 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 June 1989
Resolved 11 June 1989
Documentation
Issued 6 May 1989 Resolved
NO LICENSE FOR CHIEF MATE ONBOARD
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Documentation
Issued 6 May 1989 Resolved
NO LICENSE FOR CHIEF ENGINEER ONBOARD
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Documentation
Issued 6 May 1989 Resolved
NO LICENSE FOR ASSISTANT ENGINEER ONBOARD
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Navigation
Issued 6 May 1989 Resolved
NO CURRENT US COAST GUARD LIGHT LIST ON BOARD
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Navigation
Issued 6 May 1989 Resolved
NO CURRENT INLAND NAVIGATION RULES ONBOARD
Condition: Unknown
Due 6 May 1989
Resolved 6 May 1989
Navigation
Issued 8 July 1987 Resolved
33 CFR 164.33 NO U.S. COAST GUARD LIGHT LIST ONBOARD.
Condition: Unknown
Due 8 May 1989
Resolved 8 July 1987
Accommodation/Occupational Safety
Issued 7 September 1984 Resolved
OPERATIONAL MSD NOT BEING USED.(VALUES CLOSED,ALLOWING UNTREATED SEWAGE TO DISCHARGE OVERBOARD.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Fire Fighting
Issued 7 September 1984 Resolved
NO INTERNATIONAL SHORE CONNECTION FOR FIRE FIGHTING
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.