Records from 1985 to 1996. Most recent: inspection, 3 December 1996.
Inspection history · 18
3 December 1996
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 692512
2 December 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 398102
1 September 1996
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 438365
17 June 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 391674
22 December 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 386081
11 May 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 377948
5 April 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 376675
7 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 652617
20 March 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 90866
2 March 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 102010
16 January 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348126
20 September 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927431
20 July 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 338337
10 November 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 326772
5 November 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 319617
9 January 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 461298
9 August 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 303392
26 June 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 302668
Engineering
Issued 17 June 1996
Resolved
Renew/Repair inoperable remote fuel shut-off for the emergency generator fuel tank._x001C_ SOLAS 74 II-2/33(a)(v)_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 24 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew/Repair missing and inoperable dolling devices to watertight hatches located on the poop deck._x001C_ SOLAS 74 II-1/17(b) and ICLL 66 1/12_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 24 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew/Repair deteriorated knife edges to the 3 watertight doors located on the main deck forward side of deck house._x001C_ ICLL 66 1/12_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 24 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew/Repair deteriorated knife edge to the access trunk for #7 cargo hold._x001C_ ICLL 66 1/12_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 24 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew/Repair deteriorated knife edge to the watertight hatch located between #4 and #5 cargo hold starboard side._x001C_ ICLL 66 1/12_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew deteriorated gaskets to all watertight hatches and doors located on the main deck._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Lifesaving
Issued 17 June 1996
Resolved
Renew deteriorated ring lifebuoys (3) located on the focsle._x001C_ SOLAS 74 (Amended) III/19.2_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Engineering
Issued 17 June 1996
Resolved
Renew as original deteriorated sea water pipe located aft engine room upperlevel, aft of main air bottles._x001C_ SOLAS 74 (Amended) I/11(a)_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Engineering
Issued 17 June 1996
Resolved
Renew as original deteriorated sea water cooling pipe located on the #2 aircompressor._x001C_ SOLAS 74 (Amended) I/11(a)_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Engineering
Issued 17 June 1996
Resolved
Renew as original deteriorated sea water valve located in the engine room lower level aft starboard side. Valve is the main isolation valve for maingenerator cooling._x001C_ SOLAS 74 (Amended) I/11(a)_x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Engineering
Issued 17 June 1996
Resolved
Renew as original deteriorated sea water pipe located in the engine room lower level aft starboard side._x001C_ SOLAS 74 (Amended) I/11(a)_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Fire Fighting
Issued 17 June 1996
Resolved
Service the fixed CO2 fire extinguishing system. Provide documentation._x001C_ SOLAS 74 II-2/15_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 17 June 1996
Resolved
Renew/Repair inoperable fire damper located port side on the flying bridge._x001C_ SOLAS 74 II-2/25(c)_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 21 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew/Repair inoperable weather-tight door located aft centerline on the "C" deck._x001C_ SOLAS 74 (Amended) I/11(a)_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 21 June 1996
Engineering
Issued 17 June 1996
Resolved
Renew as original deteriorated sea water pipe on the oily water seperator._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Engineering
Issued 17 June 1996
Resolved
Prove satisfactory operation of the ships oily water seperator to the attending U.S. Coast Guard Marine Inspector._x001C_ 33 C.F.R. 155.380_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Navigation
Issued 17 June 1996
Resolved
Repair steering gear to allow for a 35 degree port and a 35 degree starboard rudder._x001C_ SOLAS 74 (Amended) II-1/29.3.2_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Fire Fighting
Issued 17 June 1996
Resolved
Renew deteriorated class "A" boundry located aft engine room upper level above the aft access door._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew missing dogs to the acess hatch located aft engine room upper level._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Lifesaving
Issued 17 June 1996
Resolved
Conduct a satisfactory fire and abandon ship drill to the satisfaction of the attending U.S. Coast Guard Inspection._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 17 June 1996
Resolved
Renew/Repair deteriorated knife edge to the watertight hatch located between #5 and #6 cargo hold starboard side._x001C_ ICLL 66 1/12_x001C_ _x001C_
Condition: Unknown
Due 19 June 1996
Resolved 26 June 1996
Documentation
Issued 17 June 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 June 1996
Resolved 21 June 1996
Lifesaving
Issued 22 December 1995
Resolved
Renew deteriorated lifelines to port and starboard life boats._x001C_ SOLAS 60 III/11(viii)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 December 1995
Resolved 26 December 1995
Lifesaving
Issued 5 April 1995
Resolved
WEAK LINKS.
Condition: Unknown
Due 5 April 1995
Resolved 21 April 1995
Fire Fighting
Issued 5 April 1995
Resolved
INTAKE VENTS ENGINE ROOM.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Electrical
Issued 5 April 1995
Resolved
LIGHT FIXTURES.
Condition: Unknown
Due 11 June 1995
Resolved 15 June 1995
Lifesaving
Issued 5 April 1995
Resolved
BILGE PUMP SUCTION HOSE
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Fire Fighting
Issued 5 April 1995
Resolved
HOLE IN FIREMAIN.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Unknown
Issued 5 April 1995
Resolved
SHIP SERVICE AIR SUPPLY.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Electrical
Issued 5 April 1995
Resolved
EMERGENCY SWITCH BOARD.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Navigation
Issued 5 April 1995
Resolved
CONTAINMENT.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Electrical
Issued 5 April 1995
Resolved
HEAT LAMPS.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Lifesaving
Issued 5 April 1995
Resolved
RETRO REFLECTIVE TAPE.
Condition: Unknown
Due 11 May 1995
Resolved 11 May 1995
Engineering
Issued 20 July 1990
Resolved
RENEW THE FLAME SCREENS IN ALL FUEL OIL/LUBE OIL DECK TANK VENTS.
Condition: Unknown
Due 20 July 1990
Resolved 20 July 1990
Navigation
Issued 10 November 1988
Resolved
33 CFR 164.38 NO ARPA ON BOARD.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Documentation
Issued 26 June 1985
Resolved
THE OTP REQ BY 33 CFR 155.720 DID NOT MEET THE REQUIREMENTS OF 33 CFR 155.750 IN THAT THEY DID NOT CONTAIN: NUMBER OF PERSONS REQ ON DUTY, DUTIES BY TITLE, INSTRUCTIONS FOR TOPPING OFF TANKS, MOORING ASSIGNMENTS, PROCEDURES FOR EMPTYING CONTAINMENT, PROCEDURES FOR SECURING VALVES.
Condition: Unknown
Due 26 June 1985
Resolved 26 June 1985
Accommodation/Occupational Safety
Issued 26 June 1985
Resolved
A LABEL AS REQ BY 33 CFR 159.7 WAS NOT ON THE M.S.D.
Condition: Unknown
Due 26 June 1985
Resolved 26 June 1985