← All vessels
OASIA
OASIA is a 1973 passenger vessel (inspected). The Coast Guard has recorded 83 inspections since 1984, most recently in December 2010, along with 129 deficiencies and 3 operational controls.
Records from 1984 to 2010. Most recent: operational control imposed, 22 December 2010.
- Built
- 1973
- Last inspected
- 22 December 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 129 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7214715 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6AZ3
223885
Flag
MALTA
—
Maury page id
psix-223885
Inspections, by type
…with no type recorded30
Years with a record
25 calendar years (1984–2010)
The 83 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it20985 - Displacement, Ton
6183 - Dead Weight, Ton
9356 - Regulatory (Subpart C or D), Net Ton
9356 - Convention (Subpart B), Net Ton
24492 - Regulatory (Subpart C or D), Gross Ton
24492 - Convention (Subpart B), Gross Ton
6183 - Dead Weight, Ton
9356 - Regulatory (Subpart C or D), Net Ton
9356 - Convention (Subpart B), Net Ton
24492 - Regulatory (Subpart C or D), Gross Ton
24492 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 83
22 December 2010
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3914666
30 September 2008
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3335256
3 October 2007
Ballast Water Examination · COC-CVE Annual · MARPOL Annex V Examination · ISPS III Exam · ILO-147 Exam · MARPOL Annex I Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3071409
10 April 2007
Type not recorded
No type recorded · Station Miami Beach · USCG Southeast District (CGD-SE) · Activity 2905452
7 April 2007
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2903492
21 March 2007
COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2890817
24 September 2006
MARPOL Annex I Examination · Ballast Water Examination · COC-CVE Quarterly · MARPOL Annex V Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2785739
24 May 2006
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2659548
24 May 2006
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2659631
24 March 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2609516
14 March 2006
Ballast Water Examination · ISPS II Exam · COC-CVE Annual
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 2602714
8 September 2005
Random ISPS/MTSA/PSC · COC-CVE Quarterly
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2486863
6 September 2005
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2485353
9 March 2005
COC-CVE Annual · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2306575
21 February 2005
COC-CVE Initial
Administrative · Activities Europe · Activity 2301141
21 January 2005
COC-CVE Annual
Administrative · Activities Europe · Activity 2280249
15 March 2004
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2024475
1 March 2004
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2015491
21 January 2004
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1989480
17 January 2002
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1479631
19 September 2001
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1073985
13 September 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 293684
13 September 2001
Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1072177
11 August 2001
Quarterly Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1466791
29 March 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 288571
29 March 2001
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1408702
16 March 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 275886
29 February 2000
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1456795
30 March 1999
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1466595
18 January 1999
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1028823
17 December 1998
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 808030
16 December 1998
MARPOL Annex I Examination · Deficiency Check · Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1375591
31 March 1998
Quarterly Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1456582
6 March 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 413472
6 March 1998
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 785295
16 December 1997
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 410953
16 December 1997
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1368522
29 April 1997
Type not recorded
No type recorded · Activities Europe · Activity 1433206
5 April 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1097176
11 February 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 68804
5 January 1997
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1097210
17 December 1996
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 398607
17 December 1996
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1427292
6 March 1996
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1368084
26 February 1996
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 388031
26 February 1996
Quarterly Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1077424
3 December 1995
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 385468
3 December 1995
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1358979
20 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 884271
19 March 1995
MARPOL Annex I Examination · Quarterly Examination · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 852321
19 January 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 869805
19 December 1994
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1377325
15 March 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 646887
28 February 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 32110
28 February 1994
Quarterly Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1354599
20 December 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1162958
6 December 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1358228
4 October 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1160182
30 March 1993
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 357709
30 March 1993
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373826
3 December 1992
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 355938
3 December 1992
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1395891
15 March 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 953794
6 December 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347953
6 December 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 942865
5 March 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 931070
17 December 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 341157
17 December 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 924139
23 April 1990
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1229604
1 December 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 334059
1 December 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 929786
7 March 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 888472
23 November 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1206422
23 November 1988
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1206468
10 February 1988
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1026356
18 November 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 320167
18 November 1987
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1195894
18 May 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 315804
14 April 1987
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1023451
29 January 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 306676
29 January 1986
Control Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1303924
4 December 1985
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1294850
17 November 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 299350
Deficiency record · 129
Operations/Management › Ballast Water Managment › Submission of Report
Issued 22 December 2010
Resolved
Vessel failed to submit a ballast water report to NVMC.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 22 December 2010
Resolved
Vessel crew claims to recieve lack of support from company creating clealiness issues in engine room. Lack of overall maintenance on the vessel.
Engineering › Bilge Water Management System › Piping
Issued 22 December 2010
Resolved
Vessels bilge contained large amounts of oil, oil dripping from ceiling, large amounts of heavy fuel oil present. Vessel began cleaning and brought to level acceptable to inspector with class to follow up at later time. Class surveyor was unavailable.
Engineering › Steering Gear System › Pump
Issued 22 December 2010
Resolved
Steering pumps had significant leaks on either side in the steering gear room. Oil dripping was creating a hazard in the space for slips as well as amount of fluid loss caused risk of unit failure. Vessel repaired to satisfaction of attending inspector with class to follow up as class was unavailable to attend vessel.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 22 December 2010
Resolved
Vessels sewage piping is leaking into shaft alley at aft of the vessel near holding tank filling bilge with sewage creating a hazardous condition.
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 December 2010
Resolved
Vessels freshwater tank above shaft alley on starboard side is leaking into shaft alley and running into bilge.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 22 December 2010
Resolved
On lifeboats #7 and #9 the stuffing boxes were worn. Also on lifeboat #7 the cutless bearing separated from the casing and slid forward on the shaft.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 22 December 2010
Resolved
Low level lighting from deck up to handle for FSD 514 was inoperable. The foreword port and aft starboard emergency escape lighting on the cinema room were found inoperable.
Stability › Watertight Integrity › General
Issued 22 December 2010
Resolved
The vessels WTD #5 is inoperable and does not allow the door to remain closed. Vessel is to replace pin.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 22 December 2010
Resolved
The bow draft marks have worn down and are not visible for readings. Vessel is to permanently affix and make visible draft marks.
Electrical › Electrical Distribution System (emergency) › Non-conducting Deck Covering
Issued 22 December 2010
Resolved
The high voltage switchboard in the BOSNS storage did not have non-conducting matting in the front or rear on deck.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 22 December 2010
Resolved
Vessels with ballast tanks must report to the U.S. prior to entering U.S. waters.
Lifesaving › Lifeboat › Hull
Issued 30 September 2008
Resolved
#10 Lifeboat forward starboard hull cracked in way of cushion pad. Repair to the satisfaction of Administration
Engineering › Fuel Oil Service System › Piping
Issued 30 September 2008
Resolved
Exhaust vent in F/O Purifier Space excessively covered in oil. Clean out vent.
Fire Fighting › Fire Main › Condition
Issued 24 September 2006
Resolved
There is a soft patch on the fire main piping, port side near life boat #12, aft of isolation valve. Vessel is to initiate safety management system reporting procedures to begin process to rectify deficiency. CLEARED ONBOARD.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 18 March 2006
Resolved
IAW 46 CFR 95.30 Sprinkler systems shall comply with NFPA 13-1996 ref. 8.5.5.3. Vessel stores shall be properly stowed allowing water discharge in a horizontal plane of more than 18 in. below the sprinkler deflector.
Deck/Cargo › Ballast › Piping
Issued 8 September 2005
Resolved
Rubber patch found on ballast water piping in the forward tunnel portside manifold. Make proper repairs to satisfaction of class.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 9 March 2005
Resolved
FSD S6 not forming an "A" boundry. Make neccesary repairs/adjustments/replacement to ensure "A" class boundry.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 March 2005
Resolved
Splash door A20 closes too fast. Repair/adjust/replace door to close safely. From work list item 86.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 9 March 2005
Resolved
Install "A" class doors to match boundry of passenger laundry. B-15 door installed in "A" class boundry.
Electrical › Lighting (service) › Outlet Box
Issued 9 March 2005
Resolved
Provide covers for electrical panels, circuit breakers, dead end cables, and put exposed wiring connections in proper junction boxes throughout vessel. Worklist item 13.
Fire Fighting › Automatic Sprinkler System › Sprinkler Grouping
Issued 9 March 2005
Resolved
Provide sprinkler, smoke detector, and appropriate SFP for all cleaning, housekeeping, electrian, etc. storage lockers located throughout the cabin areas or permanetly seal
Electrical › Lighting (service) › Lighting Fixture
Issued 9 March 2005
Resolved
Ensure all light fixtures are fitted with covers so that there are no exposed bulbs throughout the ship. Work list item 31.
Fire Fighting › Ventilation Systems › Ducts
Issued 9 March 2005
Resolved
Provide labels on access hatches/dampers for all electrical fire dampers in lido galley. Work list item 74.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 9 March 2005
Resolved
Provide flag approved proposal that shows the location of marioff, cable, pipe, and duct penetrations in all MVZ, stairway, galley, and watertight boundaries. The plan should identify the date the area was insp and list name and date insp.Plan in place within 30 days and completed 6-12 months from 2/28/05. Work list item 46
Operations/Management › Vessel Safety Management › Company Verification/Review/Evaluation
Issued 21 February 2005
Resolved
See attached worklist dated 28 FEB 05 with list of outstanding items.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 January 2005
Resolved
Found several significant deficiencies with respect to structural fire protection construction and arrangements. Issued 43 item worklist (see attached document) to address prior to receiving certificate of compliance.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 March 2004
Resolved
Properly repair Fire Screen Door C6A to ensure "A" Class integrity. Door has a significant gap around the edge and door frame.
Lifesaving › Launching Appliances
Issued 21 January 2004
Resolved
Properly repair fracture in way of the travel stop for the aft davit arm on Life Boat #12. Vessel shall not use Life Boats #11 and #12 for calculating passenger capacity until repairs are completed and verified by a Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Davit
Lifesaving › Lifeboat
Issued 21 January 2004
Resolved
Properly repair fiberglass damage to Life Boat #2 in way of the aft cleat. Recommend examining placement of this cleat due to possible impact from tricing pennant.
Fire Fighting › Fire Main
Issued 21 January 2004
Resolved
Properly repair holed firemain in way of Fire Station #15 (next to Life Boat #5) LEGACY COMPONENT DESC: Condition
Lifesaving › Launching Appliances
Issued 21 January 2004
Resolved
Properly repair oil leak in the Aft Life Raft davit on the starboard side. LEGACY COMPONENT DESC: Davit
Fire Fighting › Means of Escape
Issued 21 January 2004
Resolved
Provide evidence that access from Engine Control Room into the center Passenger Stairway is IAW the Retroactive Fire Safety Amendment. LEGACY COMPONENT DESC: Stairways
Fire Fighting › Fire Main
Issued 21 January 2004
Resolved
Properly repair holed firemain in way of Forward Stairway (M65a) LEGACY COMPONENT DESC: Condition
Fire Fighting › Structural - A Class Divisions
Issued 21 January 2004
Resolved
Demonstrate proper operation of 24 fire screen doors identified during remote closure test. LEGACY COMPONENT DESC: Openings - Fire Doors
Lifesaving › Lifeboat
Issued 21 January 2004
Resolved
Remove and properly secure unused through hull penetrations for Life Boat engine cooling system in all Life Boats. LEGACY COMPONENT DESC: Condition
Stability › Watertight Integrity
Issued 21 January 2004
Resolved
Remove the lock for the engine room access door next to the Spa. Lock prevents crew from accessing manual watertight door operation station. LEGACY COMPONENT DESC: Manual Operating Station Unaccessible
Fire Fighting › Combustible Materials
Issued 21 January 2004
Resolved
Remove combustible materials beinbg stowed in the Lobby to the Pantry in the forward passenger stairway. LEGACY COMPONENT DESC: Storage
Electrical › Electrical Distribution System (service)
Issued 21 January 2004
Resolved
Remove or properly terminate all dead end wires in electrical locker behind Fire Screen Door S.8 on Verandah Deck (Main Stariway). Repair the broken curcuit breaker and replace missing handle. LEGACY COMPONENT DESC: Wiring
Fire Fighting › Combustible Materials
Issued 21 January 2004
Resolved
Remove excess balcony doors stored on Starboard Life Boat deck. LEGACY COMPONENT DESC: Stowage
Lifesaving › Launching Appliances
Issued 21 January 2004
Resolved
Remove or replace improper wiring on Life Boat winch on the Starboard Deck (life Boat#5) LEGACY COMPONENT DESC: Winch
Electrical › Electrical Distribution System (service)
Issued 21 January 2004
Resolved
Remove or properly terminate dead end wiring on starboard boat deck in way of superstructure. LEGACY COMPONENT DESC: Wiring
Fire Fighting › Structural - A Class Divisions
Issued 21 January 2004
Resolved
Remove excess chairs from all Passenger Stairways. LEGACY COMPONENT DESC: Decks - Stairways
Fire Fighting › Structural - A Class Divisions
Issued 21 January 2004
Resolved
Prove proper operation of indicators on Fire Screen Doors C6A, V2, A22, C5A and M27. LEGACY COMPONENT DESC: Openings - Fire Doors
Operations/Management › Vessel Safety Management
Issued 21 January 2004
Resolved
Provide evidence of satisfactory impolementation of Cunard SMS via Internal Audit (Schedule to be completed NLT February) LEGACY COMPONENT DESC: Company Verification/Review/Evaluation
Construction/Loadline › Structures
Issued 21 January 2004
Resolved
Sturctural crack in bulkhead/deck between bridge deck and the winch deck in way of (IWO) the forward stair. Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Bulkhead/Deck
Operations/Management › Drills/Instruction
Issued 21 January 2004
Resolved
Provide safety harness and training for life raft deployment, prove training to the satisfaction of USCG at next US Port. i.e. (life raft, life boats and fire drills required) LEGACY COMPONENT DESC: Lifraft Davit Drill
Electrical › Electrical Distribution System (service)
Issued 21 January 2004
Resolved
Technica/locker IWO door M98 on Winch Deck has a number of Dead Cable and open electrical equipment (fire and elctrical hazard), also provide a ladder to the space, the cable just outside the space is being used as a step and is a hazard. Make permanent and proper repairs to the satisfaction of cl LEGACY COMPONENT DESC: Wiring
Fire Fighting › Combustible Materials
Issued 21 January 2004
Resolved
Lobby into pantry on the Sun Deck stairway FWD, must be claened out and place signage to have doors kept closed and no stowage in area. LEGACY COMPONENT DESC: Storage
Lifesaving › Launching Appliances
Issued 21 January 2004
Resolved
Electircal wiring to the boats winch motors loose and conduit wasted. make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Winch
Electrical › Electrical Distribution System (service)
Issued 21 January 2004
Resolved
Electrical locker on Piccadilly Deck Corridor being used as stowage and work area. Dead cables and loose power panels also. Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Wiring
Fire Fighting › Fixed Fire Detection System
Issued 21 January 2004
Resolved
Smoke detection system for stowage area, fan motor and piping on flying bridge, wasted and patched. Also, the penetration down to bridge wasted and filled of cement. Make permanent and proper repairs to the satisfaction of class. LEGACY COMPONENT DESC: Kiddie System
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 21 January 2004
Resolved
Provide evidence that puser's back office upper deck complies with direct access requirements from crew stair number 4. Cooridor bulkheads do not extend to deck above, doors to F&B manager and housekeeper offices are wood, door at frame 133 does no extend to deck above, wood shelvingin corridor. LEGACY COMPONENT DESC: Direct Access
Fire Fighting › Combustible Materials
Issued 21 January 2004
Resolved
Remvoe all items that do not meet the definition of furniture of restricted fire risk from the space between pruser information counter and B class bulkhead immediately forward. LEGACY COMPONENT DESC: Furniture/Furnishings
Fire Fighting › Structural Fire Protection - General
Issued 21 January 2004
Resolved
Provide evidence that flag has verified and accepted all retroactive fire safety amendment requirements.
Fire Fighting › Structural Fire Protection - General
Issued 21 January 2004
Resolved
Provide evidence that flag has accepted Lido café modifications, specifically space categorization boundary classification and length of main vertical zone B. See MCA letter dated 12 November 1999, last page.
Documentation › Manuals/Policy Documentation
Issued 18 January 2002
Resolved
Post emergency steering gear instructions in steering flat. LEGACY COMPONENT DESC: Emergency Instructions
Documentation › Manuals/Policy Documentation
Issued 18 January 2002
Resolved
Provide Oil Transfer procedures IAW 33 CFR 155.720. LEGACY COMPONENT DESC: Transfer Procedures
Electrical › Electrical Distribution System (service)
Issued 18 January 2002
Resolved
Provide non conductive matting in way of switchboards in control room. LEGACY COMPONENT DESC: Non-conducting Deck Covering
Documentation › Manifests/Lists
Issued 18 January 2002
Resolved
Provide PIC list as per 33 CFR 155.700. LEGACY COMPONENT DESC: PIC
Construction/Loadline
Issued 29 March 2001
Resolved
Repair leak on sea water (EVAP) pipe.
Lifesaving
Issued 29 March 2001
Resolved
Remove plastic recepticals in engineroom and throughout ship. Provide proper recepticals in accordance with SOLAS II-2.18.5.
Fire Fighting
Issued 29 March 2001
Resolved
Relocate fire fighting equipment indicators (IMO placards) in accordance with IMO resolution A.752(18).
Fire Fighting
Issued 29 March 2001
Resolved
Provide cover for electrical wire box (hold back wiring) on fire door #M36.
Fire Fighting
Issued 29 March 2001
Resolved
Remove exposed wires in stairwell at fire door remote box CM3H04.
Fire Fighting
Issued 29 March 2001
Resolved
Move light fixture or provide door stop for door M7 (light and fixture are being hit by door).
Unknown
Issued 29 March 2001
Resolved
Have class provide report of completion of items #1-#7.
Engineering
Issued 29 March 2001
Resolved
Repair leak on starboard ballast water pup and valve.
Accommodation/Occupational Safety
Issued 29 February 2000
Resolved
CLEAN AND REPAIR ALL EXHAUST DUCTS TO CREW LAUNDRY DRYERS. (SOLAS 74 II-2/USCG MSG 021939Z NOV 98). PROVIDE CLASS REPORT ATTESTING TO CORRECTIONBY 30MAR00. NOTED THAT NEARLY ALL DUCTS WERE DAMAGED OR NOT ATTACHED TO DRYERS W/ HEAVY ACCUMULATIONS OF LINT.
Lifesaving
Issued 29 February 2000
Resolved
REPAIR ENGINE TO #6 LIFEBOAT, PROVE OPERATION TO SATISFACTION OF CLASS. SOLAS 74 III/19/2 PROVIDE CLASS REPORT ATTESTING TO CORRECTION BY 30MAR00.
Fire Fighting
Issued 30 March 1999
Resolved
Prior to 09APR99, fix latch on fire doors S-9 and B-16 and replace fire door B-10.
Fire Fighting
Issued 30 March 1999
Resolved
Prior to 09APR99, have class address location of CO2 cylinder in galley, starboard side for exhaust; currently located at end of a dead-end corridor.
Accommodation/Occupational Safety
Issued 31 March 1998
Resolved
Remove all combustible waste receptacles from vessel and replace with non combustible waste receptacles complying with SOLAS 60 Part H Reg 105(I).
Construction/Loadline
Issued 31 March 1998
Resolved
Permantently repair fracture in bulwark between #2 and #4 lifeboats port side boat deck.
Navigation
Issued 31 March 1998
Resolved
Thoroughly clean hydraulic fluid and oil from all surfaces in aft steering gear space. Provide documentation from class indicating there are no excessive leaks from the steering gear.
Fire Fighting
Issued 31 March 1998
Resolved
Prove proper operation of FSD "V3" and indicator for FSD "C6".
Fire Fighting
Issued 31 March 1998
Resolved
Prove proper operation of laundry FSD. Aft access door is binding on ceiling.
Fire Fighting
Issued 31 March 1998
Resolved
Properly adjust glass doors dragging on carpet and blocking access to FSD activation switches; aft access to Casino.
Accommodation/Occupational Safety
Issued 31 March 1998
Resolved
Remove and properly stow excess combustibles stowed at the Purser's open information counter, upper deck, middle stairway.
Fire Fighting
Issued 31 March 1998
Resolved
Install proper release switch in a visible location for FSD "US9", Sun_x001C_ deck.
Electrical
Issued 31 March 1998
Resolved
Install missing light covers in lower level of engine room and steering gear space.
Lifesaving
Issued 16 December 1997
Resolved
PROVIDE CLASS REPORT OF ACCEPTABILITY/COMPLIANCE WITH SOLAS ON FWD DAVIT LAUNCH LIFERAFT ARRANGEMENT.
Fire Fighting
Issued 16 December 1997
Resolved
TEST 100% OF ALL FIRE HOSES ONBOARD. PROVIDE CLASS REPORT.
Fire Fighting
Issued 16 December 1997
Resolved
TEST 100% OF HOSE STATIONS ONBOARD. PROVIDE CLASS REPORT.
Accommodation/Occupational Safety
Issued 16 December 1997
Resolved
RENEW ALL SEWAGE PIPING IN THE SHAFT ALLEY WITH SOFT PATCHES. RENEW WASTEDSEWAGE PIPING AROUND FOUR SEWAGE TREATMENT SYSTEMS THAT ARE LEAKING. PROVIDE CLASS REPORT.
Construction/Loadline
Issued 17 December 1996
Resolved
PROVIDE OIL PLACARD AT OWS I.A.W. 33 CFR 155.450.
Accommodation/Occupational Safety
Issued 17 December 1996
Resolved
RENEW MSD'S AND SEWAGE PIPING TO THE SATISIFACTION OF THE CLASS SOCIETY AT NEXT DRY DOCK.
Lifesaving
Issued 6 March 1996
Resolved
Prior to next Quarterly Control Verification Examination, include information for firefighting duites in the crew training manual as stated on the Muster List & Emergency Instructions in accordance with SOLAS 74 (amended), Chapter III, Regulations 51.17 & 53.7 & .8.
Fire Fighting
Issued 19 March 1995
Resolved
Make the aft bridge deck fire door operational from both sides.
Lifesaving
Issued 19 January 1995
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING ON BRIDGE TOP DECK.
Lifesaving
Issued 19 January 1995
Resolved
PROVIDE EMBARKATION LADDERS FOR PORT AND STBD FWD LIFERAFT STATIONS.
Fire Fighting
Issued 19 January 1995
Resolved
PROVIDE DRAFT STOPS ON BRIDGE DECK WHERE MISSING.
Lifesaving
Issued 19 January 1995
Resolved
UPDATE SOLAS TRAINING MANUAL TO REFLECT DAVIT LAUNCHING OF LIFERAFTS.
Lifesaving
Issued 19 January 1995
Resolved
UPDATE ONBOARD FIRE SAFETY PLAN.
Lifesaving
Issued 6 December 1993
Resolved
CONDUCT A SATISFACTORY ABANDON SHIP DRILL AT NEXT U.S. PORT AND DEMONSTRATECREW KNOWLEDGE IN LAUNCHING DAVIT LAUNCHED LIFERAFTS.
Lifesaving
Issued 6 December 1993
Resolved
REMOVE BOTTLES OF HYDROCHLORIDE AND HYDROGEN PEROXIDE FROM FAN ROOM #16.
Lifesaving
Issued 6 December 1993
Resolved
INSTALL EXIT SIGNS IN "CLUB VIKING" TO INDICATE PRIMARY AND EMERGENCY EXITS.
Documentation
Issued 6 December 1993
Resolved
RESOLVE DISCREPANCY BETWEEN PASSENGER SHIP SAFETY CERTIFICATE (PSSC) AND LOADLINE CERTIFICATE. LOADLINE CERTIFICATE INDICATES A "SUMMER" LOADLINE AND THE PSSC INDICATES A "C1" SUBDIVISION LOADLINE.
Navigation
Issued 6 December 1993
Resolved
MAKE NAVIGATION RUNNING LIGHTS ON ALL TENDERS OPERATIONAL.
Lifesaving
Issued 6 December 1993
Resolved
DEMONSTRATE THAT VESSEL CAN ADEQUATELY LAUNCH LIFERAFTS WITHIN 30 MINUTES IAW SOLAS 60, REGULATION 29(a)(i). VESSEL HAS SIX(6) DAVIT-LAUNCHED LIFERAFTS STOWED AT EACH DAVIT STATION.
Lifesaving
Issued 6 December 1993
Resolved
INSTALL HAND GRIP ON DAVIT HOOK RELEASE WIRES SO THAT WIRES CAN BE PULLED FROM INSIDE LIFERAFT IN ORDER TO DISCONNECT LIFERAFT FROM HOOK.
Lifesaving
Issued 6 December 1993
Resolved
REMOVE COMBUSTIBLE (TOWELS) STOWED IN FORWARD CREW STAIR, "A" DECK, BETWEENZONES "C" AND "D".
Lifesaving
Issued 6 December 1993
Resolved
INDICATE EGRESS DIRECTION TO THE LIFEBOATS FOR PERSONNEL EXITING CREW STAIRS THROUGH FIRE DOOR A.8
Fire Fighting
Issued 30 March 1993
Resolved
REPAIR/ADJUST FIRE SCREEN DOORS #U-17 AND V-1 AND PROVE PROPER OPERATION.
Electrical
Issued 30 March 1993
Resolved
RE-MOUNT ELECT. CONTROL BOX ON WINCH AT #5 LIFEBOAT.
Electrical
Issued 30 March 1993
Resolved
PROVIDE DIELECTRIC MAT IN FRONT OF SWITCHBOARD IN EMERGENCY GEN. SPACE.
Electrical
Issued 30 March 1993
Resolved
PROPERLY STORE SPARE BATTERIES IN BATTERY ROOM.
Fire Fighting
Issued 30 March 1993
Resolved
Prove the hydro dates on the CO2 bottles satisfy the requirements of the Administration.
Accommodation/Occupational Safety
Issued 3 December 1992
Resolved
Prove the vessel's marine sanitation devices are Coast Guard approved or have been issued a certificate of approval in accordance with MARPOL Annex IV.
Construction/Loadline
Issued 3 December 1992
Resolved
Repair watertight door no. 20. The door slowly creeps open when closed_x001C_ locally by power.
Fire Fighting
Issued 3 December 1992
Resolved
Repair fire screen door no. A-21.
Construction/Loadline
Issued 3 December 1992
Resolved
Repair watertight door no. 25 indicator light on bridge.
Fire Fighting
Issued 3 December 1992
Resolved
Remove fixed CO2 symbol from the fire plan which indicates there is a fixedCO2 system in the laundry room.
Lifesaving
Issued 3 December 1992
Resolved
Clear/remove debris from the steering flat.
Electrical
Issued 3 December 1992
Resolved
Properly splice and secure wires in the overhead located in the passage waybetween the laundry room and the linen store room.
Documentation
Issued 6 December 1991
Resolved
The vessel has a fuel capacity over 10,500 gallons, and the Oil Transfer Procedures were incomplete in that they did not contain a list of each product transfered.
Lifesaving
Issued 6 December 1991
Resolved
VESSEL FAILED TO HAVE POSTED SIGNS ON EACH DECK WITHIN ALL STAIR TOWERS TO_x001C_CLEARLY INDICATE THE DIRECTION TO MUSTER STATIONS AND LIFEBOATS.
Lifesaving
Issued 6 December 1991
Resolved
VESSEL'S STORAGE LOCKERS BUILT OF COMBUSTABLE MATERIALS WITHIN THE AFT STAIR TOWER ON THE "A" DECK AND THE MAIN DECK SHALL BE REMOVED, OR PROVIDE_x001C_EVIDENCE FROM FLAG ADM. OF THEIR ACCEPTANCE._x001C_ _x001C_
Lifesaving
Issued 6 December 1991
Resolved
VESSEL'S STORAGE LOCKERS OPENED INTO THE STAIRTOWERS THAT ARE NOT PROTECTEDBY FIRE DOORS. LOCKERS SHALL NOT BE USED TO STORE COMBUSTABLE MATERIALS._x001C_
Fire Fighting
Issued 6 December 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Lifesaving
Issued 5 March 1991
Resolved
Replace warnout and wasted ring bouys located Stbd side aft, main deck.
Accommodation/Occupational Safety
Issued 5 March 1991
Resolved
Provide sign for flammables locker Strbd side aft, main deck.
Lifesaving
Issued 5 March 1991
Resolved
Child PFD lockers to be label with number of PFDS located in each storage_x001C_ location.
Engineering
Issued 17 December 1990
Resolved
FLUSH AND PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR.
Lifesaving
Issued 17 December 1990
Resolved
PROVIDE AND POST CURRENT LIFE BOAT STATION MUSTER PLACARDS AS REQUIRED BY SOLAS 1986 AND APPROVED BY IMO.
Lifesaving
Issued 17 December 1990
Resolved
END-FOR-END CABLES ON LIFEBOATS #7,8, AND 9. CABLES WERE RENEWED IN MAY 1988. SOLAS REQUIRES RENEWAL EVERY FIVE YEARS AND END-FOR-ENDING EVERY TWOAND ONE HALF YEARS.
Lifesaving
Issued 17 December 1990
Resolved
PROVIDE LIFE BOAT STARTING INSTRUCTIONS FOR EACH LIFE BOAT AS REQUIRED BY SOLAS 1986 AMENDMENTS.
Navigation
Issued 17 December 1990
Resolved
PROVIDE A NON-SKID SURFACE, HANDRAILS, AND LOSS OF HYDRAULIC FLUID ALARM FOR STEERING GEAR AS REQUIRED BY 1986 SOLAS ADMENDMENTS.
Navigation
Issued 14 April 1987
Resolved
PROVIDE A BLOCK DIAGRAM OF THE STEERING SYSTEM ON THE BRIDGE AND IN THE STEERING GEAR ROOM AS REQUIRED BY 33 CFR 164.35(K) PRIOR TO ENTERING THE NEXT U.S. PORT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.