Records from 2000 to 2012. Most recent: operational control imposed, 8 June 2012.
Inspection history · 20
8 June 2012
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4337778
25 May 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4321859
21 May 2012
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4318288
15 May 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4312579
14 May 2012
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4311140
13 May 2012
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4301990
27 February 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3953343
27 February 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3954539
25 February 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3954509
23 February 2011
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3951127
22 February 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3944470
22 February 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3422339
10 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3415385
9 January 2009
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3391538
19 March 2008
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3162399
15 January 2008
MARPOL Annex I Examination · ISPS II Exam · Deficiency Check · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3127888
7 June 2006
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2673322
31 January 2005
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2284023
21 August 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 292946
15 March 2000
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 275698
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 June 2012
Resolved
RECEIVED NOTIFICATION THAT VESSEL'S S-BAND RADAR IS INOPERABLE. ISSUED LOD 059-12.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2012
Resolution: Received Tech report stating that the S-Band radar is fully operational
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 21 May 2012
No resolution recorded
Speed log inoperable
vessel has a letter of dispinsation from flag to fix at next yard period in nov
Due 1 November 2012 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 21 May 2012
Resolved
Echo depth sounding device inoperable
Flag dispensation issued to fix at next dry dock in Nov
Due 1 November 2012
Resolved 25 May 2012
Resolution: 25MAY12: Received tech report attesting to the complete repairs and proper operation of the echosounder.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 13 May 2012
Resolved
1745 Vessel's shall be provided with oil filtering equipment, alarm arrangements, and automatic stopping arrangements to stop the discharge of effluent with greater than 15 ppm oil. Vessel's crew is unable to prove proper operation of Oily Water Seperator (OWS) and Oil Content Meter (OCM), or provide proper instructions. MARPOL Annex I, Reg. 14.7 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 May 2012
Resolution: Received class report and cleared OWS deficiency.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 13 May 2012
Resolved
1571 All ships of 300 gross tonnage and upward shall have a echo-sounding device to measure and display the available depth of water. Ship's echo depth sounds not operating properly. 74 SOLAS (09 Con.) V/2.3.1 70ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 May 2012
Resolution: 25MAY12: Received Tech report attesting to the complete repairs and proper operation of the echosounder.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 13 May 2012
No resolution recorded
1510 All ships of 300 gross tons and upwards shall be fitted with speed and distance measuring devices. Ship's speed log is not operational. 74 SOLAS (09 Con.) V/2.3.4 70ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 13 May 2012
Resolved
33CFR164.53b - Vessel failed to notify the Sector Columbia River Captain of the Port that their echo depth sounding device was not operating.
Due 13 May 2012
Resolved 13 May 2012
Resolution: Issued Notice of Violation.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 22 February 2011
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Due 22 February 2011
Resolved 23 February 2011
Resolution: VESSEL SUBMITTED FORMAL REQUEST FOR DEVIATION FROM RULES AND WAS GRANTED THE DEVIATION. THE OPERATIONAL CONTROL IS TO BE REMOVED UPON THE VESSEL''S TRANSIT PAST THE COTP ZONE.
Navigation › Collision/Grounding Avoidance › Radar
Issued 9 January 2009
Resolved
Vessel's secondary radar does not provide adequate display for navigation purposes. Provide tech report prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2009
Resolution: Recieved Tech report state that the radar is fully operational.
Documentation › Logs/Records › Oil Record Book
Issued 15 January 2008
Resolved
Oil record Book Pt. 1 has several suspicious entries concerning the through-put of oily water separator. PSCO’s expanded the engine room exam , proceeded to open the overboard discharge piping and found no evidence of illegal discharge. Therefore, the ORB entries are exceeding the max through-put capacity of the OWS as stated on IOPP. MARPOL 73/78 (2006 Edition) ANNEX I/17. To Administration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2008
Resolution: Received a Flag state survey report addressing the deficiency. Flag state will investigate inaccurate entries in the oil record book. the vessel will start a new oil record book.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 15 January 2008
Resolved
Voyage Data Recorder is currently inoperable due to a registered error with the system’s microphone. SOLAS 1974 (2004 Consolidated Edition) CH. V/20. To the satisfaction of Class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2008
Resolution: Received a Class Society survey statement and a service report from [name withheld] stating that the VDR was "fully operational and recording at this time."
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 15 January 2008
Resolved
The vessel failed to document and report nonconformities in accordance with the Safety Management System. The last nonconformity report onboard is dated in 2002. Deficiencies were discovered during the following PSC exams without a nonconformity reported: - MALTA 16MAY07, MALTA 04OCT06, USCG 30MAY06, USCG 31JAN05. ISM Code 9. To the satisfaction of the Administration.
Due 15 February 2008
Resolved 19 March 2008
Resolution: Deficiency had been satisfactorily resolved. Proof of proper documentation and reporting of nonconformities in accordance with the Safety Management System has been presented.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 June 2006
Resolved
IMO numbers on exterior shell and machinery space shall be permanetly marked by the next U.S. port.
Action required: 705 - Other - as specified
Resolved 15 January 2008
Resolution: PSCOs Verified satisfactory IMO markings that are now permanently attached to the vessel.
Construction/Loadline › Markings › Load Line Mark
Issued 7 June 2006
Resolved
Deck mark above loadline shall be painted in a contrasting color, either white or yellow, by next U.S. port.
Action required: 705 - Other - as specified
Resolved 15 January 2008
Resolution: PSCOs verified satisfactory contrasting color on the deck mark.
Engineering › Fuel Oil Service System › Hose
Issued 7 June 2006
Resolved
Double jacket on #6 cylinder is cracked. Repair/Replace by next U.S. port after sailing foreign.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 January 2008
Resolution: Vessel was in dry dock in September of 2007 and made satisfactory repairs to the double jacket on the #6 cylinder.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 31 January 2005
Resolved
The Lifeboat food rations are not airtight and are no longer serviceable. Food ration packages were moist, loose and inside contents were soft. Replace lifeboat food rations with a minimum of pieces.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 February 2005
Resolved 31 January 2005
Resolution: Vessel ordered 20 new packages of emergency food rations for the free-fall lifeboat. Agent provided USCG a copy of purchase receipt from Fire Protection Service Inc. and signed by master of m/v BBC Rheiderland on 31JAN05.