Records from 1994 to 1995. Most recent: inspection, 8 June 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 6
8 June 1995
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 379078
1 June 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 378669
24 May 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 462179
17 May 1995
Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 378385
19 January 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 708264
12 December 1994
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 372928
Construction/Loadline
Issued 17 May 1995
Resolved
SUBMIT WRITTEN VERIFICATION THAT REPAIR TO CRACK I.W.O. #4 CARGO HOLD HAS BEEN COMPLETED TO THE SATISFACTION OF THE CLASSIFICATION SOCIETY. ICLL 66_x001C_
Condition: Unknown
Due 20 May 1995
Resolved 7 June 1995
Construction/Loadline
Issued 17 May 1995
Resolved
MAKE PERMANENT REPAIRS TO THREE RUBBER PATCHES I.W.O. #3 CARGO HOLD (PORT SIDE FWD). ICLL 66
Condition: Unknown
Due 17 June 1995
Resolved 11 January 2002
Resolution: Administratively closed due to age of deficiencies.
Deck/Cargo
Issued 17 May 1995
Resolved
MAKE PERMANENT REPAIRS TO CARGO OIL CONTAINMENT I.W.O. #3 CARGO HOLD (PORT SIDE FWD). 33 CFR 155.310
Condition: Unknown
Due 17 June 1995
Resolved 11 January 2002
Resolution: Administratively closed due to age of deficiencies.
Engineering
Issued 12 December 1994
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Condition: Unknown
Due 13 December 1994
Resolved 15 December 1994
Fire Fighting
Issued 12 December 1994
Resolved
FIRE HOSES AND NOZZLES NOT IN FIRE STATION BOXES AT TIME OF BOARDING._x001C_ SOLAS CH. II-2 REG 4.7
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Lifesaving
Issued 12 December 1994
Resolved
VESSEL DID NOT HAVE SUFFICENT AMOUNT OF LIFE RING BOUYS ON STATION AT TIME OF BOARDING._x001C_ SOLAS CH. III, REG 27
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Accommodation/Occupational Safety
Issued 12 December 1994
Resolved
VESSEL IS NOT TO THROW ANY FORMS OF PLASTIC (BURNED OR WHOLE) INTO THE SEA.MUST HOLD ALL ASH FROM GARBAGE BURNED WITH PLASTICS AND DISPOSE OF ASHORE. UNLESS BURNED IN AN I.M.O. APPROVED INCINERATOR._x001C_ MARPOL V.
Condition: Unknown
Due 25 May 1995
Resolved 25 May 1995
Navigation
Issued 12 December 1994
Resolved
COAST PILOT NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Navigation
Issued 12 December 1994
Resolved
NO LIGHT LIST ON BOARD.
Condition: Unknown
Due 12 June 1995
Resolved 12 June 1995
Navigation
Issued 12 December 1994
Resolved
NO TIDE TABLES ON BOARD.
Condition: Unknown
Due 13 December 1994
Resolved 15 December 1994
Navigation
Issued 12 December 1994
Resolved
NO TIDAL CURRENT TABLES.
Condition: Unknown
Due 13 December 1994
Resolved 15 December 1994
Lifesaving
Issued 12 December 1994
Resolved
COMPRESSED GAS CYLINDERS IN STEERING ROOM NOT IN RACKS._x001C_ 46 CFR 147.1(b) via 33 CFR 160.109
Condition: Unknown
Due 13 December 1994
Resolved 15 December 1994
Engineering
Issued 12 December 1994
Resolved
SMALL CONTAINMENT AROUND TANK VENTS WASTED (HOLED OUTBOARD SIDE) OR VENTS VENT OVER CONTAINMENT. (VENTS #11,10,8,4,3 PORT; #2,3,11,12 STARBOARD). _x001C_ 33 C.F.R. 155.320(b)
Condition: Unknown
Due 12 December 1994
Resolved 15 December 1994
Documentation
Issued 12 December 1994
Resolved
NO POLUTION PLACARD.
Condition: Unknown
Due 13 December 1994
Resolved 15 December 1994