← All vessels
CLIPPER UNITY
CLIPPER UNITY is a 1973 freight ship. The Coast Guard has recorded 16 inspections since 1993, most recently in March 1997, along with 33 deficiencies and 3 operational controls.
Records from 1993 to 1997. Most recent: inspection, 5 March 1997.
- Built
- 1973
- Last inspected
- 5 March 1997
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 33 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7300899 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
C6HI6
224134
Flag
TURKEY
—
Maury page id
psix-224134
Inspections, by type
…with no type recorded16
Years with a record
4 calendar years (1993–1997)
The 16 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8001 - Dead Weight, Ton
3061 - Regulatory (Subpart C or D), Net Ton
6150 - Regulatory (Subpart C or D), Gross Ton
3061 - Regulatory (Subpart C or D), Net Ton
6150 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 16
5 March 1997
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 401165
8 December 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 707750
7 November 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 53552
7 November 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 397244
31 August 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 204204
26 August 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 394658
8 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 392953
25 May 1996
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 391399
18 March 1996
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 137498
1 February 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387241
3 December 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 385180
13 October 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 383583
28 August 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 707751
13 August 1995
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 381544
7 April 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 692566
6 April 1993
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 357456
Deficiency record · 33
Electrical
Issued 7 November 1996
Resolved
Remove extension cord for clothes washer/dryer and make permanant installation of receptacle.
Construction/Loadline
Issued 7 November 1996
Resolved
Provide report from diver on condition of bottom plating.
Navigation
Issued 7 November 1996
Resolved
Provide class report on repairs to steering system.
Construction/Loadline
Issued 7 November 1996
Resolved
provide class surveyor's report concerning buckled framing at starboard E/Rcompressor deck.
Electrical
Issued 7 November 1996
Resolved
Make repairs to the 220V power supply, broken fuse block located on the portside main switchboard which provides power to the bridge vital distribution panel, i.e., EOCT, rudder angle indicator, steering system control signal.
Construction/Loadline
Issued 7 November 1996
Resolved
Provide class report on condition of bottom and internal structure due to grounding.
Lifesaving
Issued 26 August 1996
Resolved
Provide a boat and fire drill to the satisfaction of the CG inspectors.
Deck/Cargo
Issued 26 August 1996
Resolved
Provide a machinery guard on the auxilary boiler feed pump.
Electrical
Issued 26 August 1996
Resolved
Repair electrical wiring on refrigeration plant.
Fire Fighting
Issued 8 July 1996
Resolved
A VIO OF SOLAS 74 REG AMENDED II-2/21 IN THAT THE DISCHARGE LINE FOR THE EMERGENCY FIRE PUMP LOCATED IN THE FIRE PUMP COMPT HAD A CRACK CAUSING INSUFFICIENT DISCHARGE. CLASS TO VISIT VESSEL AND PROVIDE REPORT ON EMERGENCY FIRE PUMP PRIOR TO DEPARTING PORT._x001C_
Lifesaving
Issued 8 July 1996
Resolved
A VIO OF SOLAS 60 REG III/8 (b)(c) IN THAT THE CREW WAS UNABLE TO KEEP THE STARBOARD MOTOR LIFEBOAT RUNNING WITHOUT THE AID IF STARTING FLUID. CLASS TO VISIT VESSEL AND PROVIDE REPORT PRIOR TO DEPARTING PORT._x001C_ _x001C_
Lifesaving
Issued 8 July 1996
Resolved
A VIO OF SOLAS 74 CH-1 REG 11 IN THAT THERE WAS CARGO IN THE MAIN DECK WELLDECK AREA CAUSING A IMPROPER EGRESS PATTERN FROM THE AFT PART OF THE SHIP TO THE FORWARD PART OF THE SHIP. CORRECT PRIOR TO DEPARTING PORT._x001C_ _x001C_
Lifesaving
Issued 1 February 1996
Resolved
RENEW/REPAIR PORT LIFEBOAT ENGINE, PROVE OPERATION TO THE SATISFACTION OF_x001C_ THE ATTENDING U.S. COAST GUARD INSPECTOR.
Electrical
Issued 13 August 1995
Resolved
Electrical cable wires were run thru a watertight door leading from main switchboard room into engine room. Issued requirement to remove elctrical run from watertight door and properly run wires thru bulkhead fittings.
Construction/Loadline
Issued 13 August 1995
Resolved
Watertight door, port side on bridge deck, was warped and not able to closeproperly. Issued requirement to repair door.
Lifesaving
Issued 13 August 1995
Resolved
Vessel had excessive oil on deck plates in engine room and steering gear room. Issued requirement to clean oil from deck plates.
Lifesaving
Issued 13 August 1995
Resolved
Various general service pumps in engine room were missing protective coversfor moving parts. Issued requirement to provide protective covers for_x001C_ moving parts.
Accommodation/Occupational Safety
Issued 13 August 1995
Resolved
Vessel had an installed Type II MSD with no certification label. Issued requirement to provide label.
Documentation
Issued 13 August 1995
Resolved
Vessel was in violation of 33 CFR 151.63 in that no record of garbage disposals were documentated or recorded.
Documentation
Issued 13 August 1995
Resolved
The vessel arrived in port with an expired Safety Radio certificae, Certificate expired while vessel was underway enroute to Savannah, GA.
Electrical
Issued 13 August 1995
Resolved
Vessel was missing numerous protective covers for lighting in engine room spaces. Issued requirement to provide protective covers for all lights in engine room spaces.
Fire Fighting
Issued 13 August 1995
Resolved
Emergency exit doors located in engine room, mid-deck, port and stbd sides,had inoperatble closing devices. Issued requirement to repair doors prior to 13 SEP 95.
Electrical
Issued 13 August 1995
Resolved
Electrical wires through the engine room were not properly secured. Issuedrequirement to properly secure/hang electricl runs in engine room.
Construction/Loadline
Issued 13 August 1995
Resolved
Deck by forward capstan, stbd side, had excessive oil on deck. Issued requirement to remove oil from deck.
Lifesaving
Issued 13 August 1995
Resolved
Exhaust piping from forward emergency fire pump engine was not insulated orprotected in an exposed area on forward foscle deck. Issued requirement toprovide insulation or protective cover for exposed exhaust pipe.
Documentation
Issued 6 April 1993
Resolved
VESSEL DID NOT HAVE ANY POLLUTION PLACARDS POSTED IN THE ENGINE ROOM. THEYHAD STENCILED NO DISCHARGE OF OIL ON THE BULKHEAD BUT DID NOT FUFILL THE REQUIREMENT.
Documentation
Issued 6 April 1993
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE, ITEMS MISSING WERE PROCEDURES FOR TOPPING OFF, EMPTYING MANIFOLD CONTAINMENT,, CARGO INFORMATION, DUTIES FOR TENDING MOORING LINES, AND PROCEDURES FOR OPERATING EMERGENCY SHUTDOWN.
Navigation
Issued 6 April 1993
Resolved
VESSEL DID NOT HAVE ANY CHART ONBOARD FOR THE SAVANNAH RIVER.
Navigation
Issued 6 April 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 6 April 1993
Resolved
VESSEL DID NOT HAVE A 1993 TIDE TABLE ONBOARD.
Navigation
Issued 6 April 1993
Resolved
VESSEL DID NOT HAVE A 1993 TIDAL CURRENT TABLE ONBOARD.
Navigation
Issued 6 April 1993
Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ONBOARD.
Navigation
Issued 6 April 1993
Resolved
VESSEL DID NOT LOG PRE ARRIVAL TEST BEFORE ENTERING THE PORT OF SAVANNAH.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.