Records from 1993 to 1997. Most recent: inspection, 5 March 1997.

Built
1973
Last inspected
5 March 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7300899 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224134
Flag
TURKEY
—
Maury page id
psix-224134

Inspections, by type

…with no type recorded16
Years with a record 4 calendar years (1993–1997)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it8001 - Dead Weight, Ton
3061 - Regulatory (Subpart C or D), Net Ton
6150 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 16

5 March 1997 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 401165
8 December 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 707750
7 November 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 53552
7 November 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 397244
31 August 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 204204
26 August 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 394658
8 July 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 392953
25 May 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 391399
18 March 1996 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 137498
1 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 387241
3 December 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 385180
13 October 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 383583
28 August 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 707751
13 August 1995 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 381544
7 April 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 692566
6 April 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 357456

Deficiency record · 33

Electrical
Issued 7 November 1996 Resolved
Remove extension cord for clothes washer/dryer and make permanant installation of receptacle.
Condition: Unknown
Due 6 March 1997
Resolved 6 March 1997
Construction/Loadline
Issued 7 November 1996 Resolved
Provide report from diver on condition of bottom plating.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Navigation
Issued 7 November 1996 Resolved
Provide class report on repairs to steering system.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Construction/Loadline
Issued 7 November 1996 Resolved
provide class surveyor's report concerning buckled framing at starboard E/Rcompressor deck.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Electrical
Issued 7 November 1996 Resolved
Make repairs to the 220V power supply, broken fuse block located on the portside main switchboard which provides power to the bridge vital distribution panel, i.e., EOCT, rudder angle indicator, steering system control signal.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Construction/Loadline
Issued 7 November 1996 Resolved
Provide class report on condition of bottom and internal structure due to grounding.
Condition: Unknown
Due 10 November 1996
Resolved 12 November 1996
Lifesaving
Issued 26 August 1996 Resolved
Provide a boat and fire drill to the satisfaction of the CG inspectors.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Deck/Cargo
Issued 26 August 1996 Resolved
Provide a machinery guard on the auxilary boiler feed pump.
Condition: Unknown
Due 27 August 1996
Resolved 27 August 1996
Electrical
Issued 26 August 1996 Resolved
Repair electrical wiring on refrigeration plant.
Condition: Unknown
Due 6 March 1997
Resolved 6 March 1997
Fire Fighting
Issued 8 July 1996 Resolved
A VIO OF SOLAS 74 REG AMENDED II-2/21 IN THAT THE DISCHARGE LINE FOR THE EMERGENCY FIRE PUMP LOCATED IN THE FIRE PUMP COMPT HAD A CRACK CAUSING INSUFFICIENT DISCHARGE. CLASS TO VISIT VESSEL AND PROVIDE REPORT ON EMERGENCY FIRE PUMP PRIOR TO DEPARTING PORT._x001C_
Condition: Unknown
Due 9 July 1996
Resolved 8 July 1996
Lifesaving
Issued 8 July 1996 Resolved
A VIO OF SOLAS 60 REG III/8 (b)(c) IN THAT THE CREW WAS UNABLE TO KEEP THE STARBOARD MOTOR LIFEBOAT RUNNING WITHOUT THE AID IF STARTING FLUID. CLASS TO VISIT VESSEL AND PROVIDE REPORT PRIOR TO DEPARTING PORT._x001C_ _x001C_
Condition: Unknown
Due 9 July 1996
Resolved 8 July 1996
Lifesaving
Issued 8 July 1996 Resolved
A VIO OF SOLAS 74 CH-1 REG 11 IN THAT THERE WAS CARGO IN THE MAIN DECK WELLDECK AREA CAUSING A IMPROPER EGRESS PATTERN FROM THE AFT PART OF THE SHIP TO THE FORWARD PART OF THE SHIP. CORRECT PRIOR TO DEPARTING PORT._x001C_ _x001C_
Condition: Unknown
Due 9 July 1996
Resolved 8 July 1996
Lifesaving
Issued 1 February 1996 Resolved
RENEW/REPAIR PORT LIFEBOAT ENGINE, PROVE OPERATION TO THE SATISFACTION OF_x001C_ THE ATTENDING U.S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 3 February 1996
Resolved 3 February 1996
Electrical
Issued 13 August 1995 Resolved
Electrical cable wires were run thru a watertight door leading from main switchboard room into engine room. Issued requirement to remove elctrical run from watertight door and properly run wires thru bulkhead fittings.
Condition: Unknown
Due 16 August 1995
Resolved 16 August 1995
Construction/Loadline
Issued 13 August 1995 Resolved
Watertight door, port side on bridge deck, was warped and not able to closeproperly. Issued requirement to repair door.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Lifesaving
Issued 13 August 1995 Resolved
Vessel had excessive oil on deck plates in engine room and steering gear room. Issued requirement to clean oil from deck plates.
Condition: Unknown
Due 16 August 1995
Resolved 16 August 1995
Lifesaving
Issued 13 August 1995 Resolved
Various general service pumps in engine room were missing protective coversfor moving parts. Issued requirement to provide protective covers for_x001C_ moving parts.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Accommodation/Occupational Safety
Issued 13 August 1995 Resolved
Vessel had an installed Type II MSD with no certification label. Issued requirement to provide label.
Condition: Unknown
Due 4 December 1995
Resolved 4 December 1995
Documentation
Issued 13 August 1995 Resolved
Vessel was in violation of 33 CFR 151.63 in that no record of garbage disposals were documentated or recorded.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Documentation
Issued 13 August 1995 Resolved
The vessel arrived in port with an expired Safety Radio certificae, Certificate expired while vessel was underway enroute to Savannah, GA.
Condition: Unknown
Due 16 August 1995
Resolved 16 August 1995
Electrical
Issued 13 August 1995 Resolved
Vessel was missing numerous protective covers for lighting in engine room spaces. Issued requirement to provide protective covers for all lights in engine room spaces.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Fire Fighting
Issued 13 August 1995 Resolved
Emergency exit doors located in engine room, mid-deck, port and stbd sides,had inoperatble closing devices. Issued requirement to repair doors prior to 13 SEP 95.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Electrical
Issued 13 August 1995 Resolved
Electrical wires through the engine room were not properly secured. Issuedrequirement to properly secure/hang electricl runs in engine room.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Construction/Loadline
Issued 13 August 1995 Resolved
Deck by forward capstan, stbd side, had excessive oil on deck. Issued requirement to remove oil from deck.
Condition: Unknown
Due 16 August 1995
Resolved 16 August 1995
Lifesaving
Issued 13 August 1995 Resolved
Exhaust piping from forward emergency fire pump engine was not insulated orprotected in an exposed area on forward foscle deck. Issued requirement toprovide insulation or protective cover for exposed exhaust pipe.
Condition: Unknown
Due 16 October 1995
Resolved 16 October 1995
Documentation
Issued 6 April 1993 Resolved
VESSEL DID NOT HAVE ANY POLLUTION PLACARDS POSTED IN THE ENGINE ROOM. THEYHAD STENCILED NO DISCHARGE OF OIL ON THE BULKHEAD BUT DID NOT FUFILL THE REQUIREMENT.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Documentation
Issued 6 April 1993 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE, ITEMS MISSING WERE PROCEDURES FOR TOPPING OFF, EMPTYING MANIFOLD CONTAINMENT,, CARGO INFORMATION, DUTIES FOR TENDING MOORING LINES, AND PROCEDURES FOR OPERATING EMERGENCY SHUTDOWN.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 6 April 1993 Resolved
VESSEL DID NOT HAVE ANY CHART ONBOARD FOR THE SAVANNAH RIVER.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 6 April 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 6 April 1993 Resolved
VESSEL DID NOT HAVE A 1993 TIDE TABLE ONBOARD.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 6 April 1993 Resolved
VESSEL DID NOT HAVE A 1993 TIDAL CURRENT TABLE ONBOARD.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 6 April 1993 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ONBOARD.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Navigation
Issued 6 April 1993 Resolved
VESSEL DID NOT LOG PRE ARRIVAL TEST BEFORE ENTERING THE PORT OF SAVANNAH.
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.