Records from 1985 to 1989. Most recent: inspection, 23 August 1989.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 5
23 August 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 332313
23 August 1989
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1032148
23 August 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1033636
12 June 1988
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208628
31 May 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 302259
Fire Fighting
Issued 12 June 1988
Resolved
MAKE PERMANENT REPAIRS TO LEAKS IN MAIN DECK FIRE MAIN PIPE.
Condition: Unknown
Due 12 June 1988
Resolved 12 June 1988
Deck/Cargo
Issued 31 May 1985
Resolved
REPAIR LEAK IN HYDRAULIC LINES TO VALVE NO.63 IN CARGO PUMPROOM.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Deck/Cargo
Issued 31 May 1985
Resolved
DETERMINE PURPOSE OF A SMALL STEAM LINE LEADING TO THE IGS FEEDLINE FOR NO.6 PORT AND STBD TANKS.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Deck/Cargo
Issued 31 May 1985
Resolved
SUSPECT SMALL LEAK IN NO.3 CARGO PUMP INTAKE LINE JUST BELOW THE TELEPHONE BOOK IN THE PUMP ROOM. REPAIR IF NECESSARY.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Deck/Cargo
Issued 31 May 1985
Resolved
NO.2 AND NO.3 CARGO PUMPS IN PUMPROOM ARE LEAKING EXCESSIVELY. THEY WERE NOT OPERATING AT THE TIME OF USCG EXAMINATION.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Deck/Cargo
Issued 31 May 1985
Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY PATCHES ON BOTH THE INTAKE AND DISCHARGE LINES FOR CARGO PUMPS NO.2 IN PUMPROOM.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Deck/Cargo
Issued 31 May 1985
Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY PATCHES ON BOTH THE INTAKE AND DISCHARGE LINES FOR CARGO PUMP NO.2 IN PUMP ROOM
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
MAKE PERMANENT REPAIRS TO MAINDECK FOAM LINES WHEREVER LEAKING
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
MAKE PERMANENT REPAIR TO TEMPORARY PATCH ON BUNKER LINE IN WAY OF PORT SIDE AFT OF CARGO MANIFOLD ON MAIN DECK
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
RENEW WASTED ELECTRICAL JUNCTION BOX ON FOREPEAK PUMP ROOM VENT ON MAIN DECK
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
REMOVE FLAME SCREEN ON VENT TO MAIN DECK PAINT LOCKER SCREEN IS MISSING ALSO REPLACE CRACKED PORT LIGHT GLASS OR COVER WITH FLAME SCREEN 46 CFR 35-30-10
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
REPAIR EXCESS LEAK IN DRAIN LINE VALVE ON STARBOARD SIDE CARGO MANIFOLD LINE NO.3. PACKING APPEARS BAD.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
MAKE PERMANENT REPAIR TO TEMPORARY PATCH ON NO.1. CARGO MANIFOLD LINE IN WAY OF THE FIRST BEND JUST INBOARD OF THE CARGO MANIFOLD ON STARBOARD SIDE.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
REPAIR WASTED BOLTS ON MAIN CARGO LINES NO.1 AND NO.2 FOR BLOCK VALVE. BOLTS FOR EXPANSION JOINT SECTION ARE WASTED AND NEED RENEWING.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985
Unknown
Issued 31 May 1985
Resolved
MAKE PERMANENT REPAIR TO TEMPORARY PATCH ON OVERBOARD DISCHARGE LINE ON THEPORT SIDE OF PUMP ROOM NEAR VALVE NO.68.
Condition: Unknown
Due 31 May 1985
Resolved 31 May 1985