MAURY USCG vessel records Sign in
← All vessels

SUPERINA

SUPERINA is a 1973 freight ship. The Coast Guard has recorded 28 inspections since 1984, most recently in April 1997, along with 62 deficiencies and 1 operational control.

Records from 1984 to 1997. Most recent: inspection, 17 April 1997.

Built
1973
Last inspected
17 April 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7314814 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
224274
Flag
GREECE
—
Maury page id
psix-224274

Inspections, by type

…with no type recorded26
Years with a record 14 calendar years (1984–1997)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28871 - Dead Weight, Ton
10383 - Regulatory (Subpart C or D), Net Ton
16656 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

17 April 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 722870
31 March 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 401984
24 March 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389314
12 October 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 383792
3 April 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 377043
1 February 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 374873
28 December 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 851614
29 August 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177280
20 June 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 367916
20 June 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022358
15 February 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 647279
14 February 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 485195
29 August 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 370020
9 July 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 440165
19 February 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 356442
9 September 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 498842
7 January 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 348032
3 June 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 527478
19 October 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 339864
6 August 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 492960
15 February 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 464142
24 August 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332202
10 August 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 325012
20 February 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 493686
5 June 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 309214
26 December 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 517435
6 February 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 300316
13 November 1984 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 298978

Deficiency record · 62

Lifesaving
Issued 31 March 1997 Resolved
PROVIDE ON BOARD A RUST PROOF DIPPER WITH A LANYARD._x001C_ SOLAS 60III/11(a)(xiii)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
RENEW THE DETERIORATED FUEL TANK FOR THE STBD LIFEBOAT._x001C_ SOLAS 74(AMENDED)III/19.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Engineering
Issued 31 March 1997 Resolved
PROVE THE PROPPER OPERATION OF THE OILY WATER SEPARATOR, ALARMS, AND AUTOMATIC STOPPING DEVICE._x001C_ CC C.F.R. 155.370
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
RENEW THE ROTTEN WOODEN SEATING IN THE PORT LIFEBOAT._x001C_ SOLAS 74(AMENDED)III/19.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
RENEW THE INOPERABLE WATER LIGHT FOR THE LIFEBUOY LOCATED ON THE PORT SIDE FORWARD._x001C_ SOLAS 74(AMENDED)II/19.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Electrical
Issued 31 March 1997 Resolved
RENEW/REPAIR THE ELECTRICAL JUNCTION BOX WHERE THE WIRES HAVE BEEN EXPOSED LOCATED IN THE FORWARD BOATSWAIN STORES IN OVERHEAD._x001C_ SOLAS 60 II/27(a)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
RENEW THE DETERIORATED LIFEBUOY LOCATED ON THE PORT SIDE MAIN DECK AT FORECASTLE._x001C_ SOLAS 74(AMENDED) III/19.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
RENEW BATTERIES FOR ALL LIFEJACKET WATER LIGHTS._x001C_ SOLAS 74(AMENDED)III/19.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Documentation
Issued 31 March 1997 Resolved
PROVIDE ON BOARD AN APPROVED SHIPBOARD OIL POLLUTION EMERGENCY PLAN IN ACCORDANCE WITH 33 C.F.R. 151.26
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Accommodation/Occupational Safety
Issued 31 March 1997 Resolved
RENEW/REPAIR ALL DETERIORATED GUARD RAILS SUPPORTS ON THE BOAT DECK._x001C_ ICLL 66 ANNEX I/25
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE ON BOARD A LIFESAVING TRAINING MANUAL EASILY UNDERSTOOD BY THE VESSELS CREW. _x001C_ SOLAS74(AMENDED) III/18.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
INSTALL WEAK LINK ON THE PORT LIFERAFT AND PROPERLY INSTALL WEAK LINK ON THE STBD LIFERAFT._x001C_ SOLAS 74(AMENDED) III/29
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE ON BOARD INSTRUCTIONS FOR THE ON BOARD MAINTENENCE OF LIFESAVING EQUIPMENT._x001C_ SOLAS 74 (AMENDED) III/19.3
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Documentation
Issued 31 March 1997 Resolved
PROVIDE ON BOARD A VALID INTERNATIONAL LOAD LINE CERTIFICATE._x001C_ ICLL 66 ARTICLE 3
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE A SUITABLE LOCKER FOR THE STOWAGE OF SMALL ITEMS FOR THE PORT AND STBD LIFEBOATS.
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
RENEW THE COMBINATION SMOKE AND LIGHT BUOYS FOR THE PORT AND STARBOARD BRIDGE WING LIFEBUOYS._x001C_ SOLAS 74 (AMENDED)III/19.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Deck/Cargo
Issued 31 March 1997 Resolved
INSTALL MACHINERY GUARDS ON THE #1 AND #2 COOLING PUMPS FOR THE VESSELS REFRIGERATION SYSTEM LOCATED ON THE LOWER LEVEL OF THE ENGINE ROOM, STBD SIDE OUTBOARD OF MAIN ENGINE._x001C_ SOLAS 74(AMENDED) I/11(a)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Engineering
Issued 31 March 1997 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER COOLING PIPE FOR THE #1 GENERATOR LUBE OIL COOLER._x001C_ SOLAS 74 (AMENDED)I/11(a)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE 10 ADDITIONAL FOOD RATIONS FOR THE STARBOARD LIFEBOAT._x001C_ SOLAS 60/11(a)(xii)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE 2 BUOYANT SMOKE SIGNALS FOR EACH OF THE PORT AND STARBOARD LIFEBOATS._x001C_ SOLAS 60 III/11(a)(xv)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Documentation
Issued 31 March 1997 Resolved
PROVIDE ON BOARD A VALID SAFE MANNING CERTIFICATE._x001C_ SOLAS 74(AMENDED) V/13(b)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Documentation
Issued 31 March 1997 Resolved
PROVIDE ON BOARD A VALID INTERNATIONAL TONNAGE CERTIFICATE._x001C_ ITC ART.7
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
PERFORM A SATISFACTORY FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR._x001C_ SOLAS 74(AMENDED) III/18.3.4-3.9, 18.3.10-3.13
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Accommodation/Occupational Safety
Issued 31 March 1997 Resolved
RENEW AS ORIGINAL THE DETERIORATED SEA WATER PIPING FOR THE FRESH WATER GENERATOR LOCATED ON THE 3RD LEVEL OF THE ENGINE ROOM, PORT SIDE._x001C_ SOLAS 74 (AMENDED)I/11(a)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
RENEW/REPAIR THE INOPERABLE VENTILATION CLOSURES THROUGHOUT THE VESSEL. ENSURE ALL DOGS ARE OPERABLE AND HAVE CLOSING DOG/NUT.
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
REPAIR/RENEW THE INOPERABLE EMERGENCY FIRE PUMP._x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
RENEW THE DETERIORATED FIRE HYDRANT LOCATED ON THE PORT BRIDGE WING._x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Documentation
Issued 31 March 1997 Resolved
PROVIDE ON BOARD VESSEL A VALID SAFETY CONSTRUCTION, SAFETY EQUIPMENT, AND SAFETY RADIO CERTIFICATE._x001C_ SOLAS 74(AMENDED) I/12,14
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Documentation
Issued 31 March 1997 Resolved
PROVIDE ON BOARD A VALID INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE._x001C_ MARPOL 73/78 ANNEX I/5
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Navigation
Issued 31 March 1997 Resolved
PROVE THE PROPPER OPERATION OF THE ENGINE ORDER TELEGRAPH._x001C_ SOLAS 60 II/33
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Unknown
Issued 31 March 1997 Resolved
COMPLETE TO THE SATISFACTION OF THE AMERICAN BUREAU OF SHIPPING ALL OUTSTANDING CONDITIONS OF CLASS AS LISTED IN ABS REPORT #M24812.
Condition: Unknown
Due 1 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 31 March 1997 Resolved
RENEW THE RETRO REFLECTIVE TAPE FOR THE BRIDGEWING LIFE BUOYS._x001C_ SOLAS 74(AMENDED)III/30.2.7
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
PROVIDE ON BOARD VESSEL ONE ADDITIONAL FIREMANS OUTFIT._x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
RENEW THE HOLED/DETERIORATED FIRE HOSE LOCATED ON THE PORT SIDE FORECASTLE.SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
RENEW THE DETERIORATED LIFEBOUY LOCATED ON THE STARBOARD SIDE, AFT POOP DECK._x001C_ SOLAS 74(AMENDED)III/19.2
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
INSTALL RETRO-REFLECTIVE MATERIAL ON THE PORT AND STARBOARD LIFEBOATS IN ACCORDANCE WITH SOLAS 74(AMENDED)III/30.2.7 AND IMO RESOLUTION A.658(16)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE NEW LINE THROUGHING APPLIANCE ON BOARD VESSEL._x001C_ SOLAS 60 III/23
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Lifesaving
Issued 31 March 1997 Resolved
PROVIDE DOCUMENTATION THAT THE PORT AND STARBOARD LIFEBOAT FALLS HAVE BEEN RENEWED WITHIN THE PAST 5 YEARS OR END FOR ENDED WITHIN THE 30 MONTHS. IF THIS CANNOT BE DONE THE FALLS MUST BE REPLACED._x001C_ SOLAS 74(AMENDED)III/19.3.4
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
RENEW THE DETERIORATED BREATHING APPARATUS FOR THE FIREMANS OUTFIT._x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
REPAIR/RENEW THE LEAKING/INOPERABLE FIRE HYDRANT LOCATED ON THE PORT SIDE, AFT POOP DECK._x001C_ SOLAS 74 (AMENDED)II-2/21
Condition: Unknown
Due 3 April 1997
Resolved 17 April 1997
Fire Fighting
Issued 31 March 1997 Resolved
PROVIDE ON BOARD VESSEL INSTRUCTIONS FOR MAINTENCE AND OPERATION OF ALL FIREFIGHTING INSTALLATIONS/EQUIPMENT IN THE LANGUAGE OF THE FLAG STATE, ENGLISH, OR FRENCH.
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Fire Fighting
Issued 31 March 1997 Resolved
RENEW AS ORIGINAL THE DETERIORATED FIREMAIN PIPING LOCATED ON THE STARBOARDSIDE MAIN DECK, OUTBOARD OF CARGO HOLDS #2 AND #3. _x001C_ SOLAS 74(AMENDED)II-2/21
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Accommodation/Occupational Safety
Issued 31 March 1997 Resolved
RENEW AS ORIGINAL THE DETERIORATED PIPING FOR THE #2 MAIN ENGINE FRESH WATER COOLER LOCATED ON THE STARBOARD SIDE OF THE ENGINE ROOM OUTBOARD OF THE MAIN ENGINE ON FORWARD END OF COOLER.
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Navigation
Issued 31 March 1997 Resolved
PROVIDE EMERGENCY STEERING INSTRUCTIONS ON THE BRIDGE._x001C_ SOLAS 74(AMENDED)V/19.2(l)
Condition: Unknown
Due 3 April 1997
Resolved 23 May 1997
Documentation
Issued 3 April 1995 Resolved
PROVIED CURRENT SAFE MANNING CERTIFICATE ON BOARD VESSEL AND DEMONSTRATE COMPLIANCE THERE WITH.
Condition: Unknown
Due 8 April 1995
Resolved 6 April 1995
Accommodation/Occupational Safety
Issued 1 February 1995 Resolved
98% OF CREW TOILETS INOPERABLE. (ILO 147)_x001C_ * CORRECTED ON THE 01 FEB 95
Condition: Unknown
Due 1 February 1995
Resolved 12 February 1995
Lifesaving
Issued 1 February 1995 Resolved
IMPROPER STORAGE OF LIFE-JACKETS (PFD) IN CREW AREA. (SOLAS III)
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Accommodation/Occupational Safety
Issued 1 February 1995 Resolved
EXCESSIVE DAMAGE IN CREW AREA PASSAGEWAY. (ILO 147)
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Accommodation/Occupational Safety
Issued 1 February 1995 Resolved
WORN/WASTED WATER-TIGHT DOORS ON MAIN DECK. (SOLAS II)
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Accommodation/Occupational Safety
Issued 1 February 1995 Resolved
REEFER DOORS (3) MISSING EMERGENCY ESCAPE/EXITING DEVICES. (ILO 147)
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Navigation
Issued 1 February 1995 Resolved
STEERING POWER ALARM FAILED (BRIDGE). (SOLAS II)
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Construction/Loadline
Issued 1 February 1995 Resolved
WASTED/FRACTURED CARGO HOLD FRAMES AT MAIN DECK. (SOLAS I)
Condition: Unknown
Due 30 April 1995
Resolved 7 April 1995
Construction/Loadline
Issued 1 February 1995 Resolved
MAIN DECK WASTED (EXCESSIVE) BETWEEN CARGO HOLDS #4 AND #5, ALSO OVER 26 DOUBLERS. (SOLAS I)
Condition: Unknown
Due 14 October 1995
Resolved 13 October 1995
Electrical
Issued 1 February 1995 Resolved
VESSEL MISSING PROTECTIVE LIGHT GLOBES THROUGHTOUT THE VESSEL. (SOLAS II)
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Electrical
Issued 1 February 1995 Resolved
VESSEL MISSING EXPLOSION PROOF LIGHTING IN MID-BODY PAINT LOCKER. (SOLAS II)
Condition: Unknown
Due 13 October 1995
Resolved 13 October 1995
Fire Fighting
Issued 20 June 1994 Resolved
Replace expansion joint in fire main in way of #2 cargo hatch, starboard side.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Deck/Cargo
Issued 20 June 1994 Resolved
Remove or repair piping for cargo hatch hydraulic system opening.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Fire Fighting
Issued 20 June 1994 Resolved
Repair fire main in way of #4 cargo hatch, starboard side.
Condition: Unknown
Due 30 August 1994
Resolved 30 August 1994
Navigation
Issued 10 August 1988 Resolved
THE VESSEL'S CHARTS OF THE AREA WERE NOT CURRENTLY CORRECTED. 33CFR164.33(A)(1).
Condition: Unknown
Due 10 August 1988
Resolved 10 August 1988
Navigation
Issued 13 November 1984 Resolved
CHARTS OF TAMPA BAY (11413 & 11414) WERE OUTDATED (1978).
Condition: Unknown
Due 20 February 1987
Resolved 13 November 1984
Navigation
Issued 13 November 1984 Resolved
U.S. COAST PILOT WAS OUTDATED (1978).
Condition: Unknown
Due 20 February 1987
Resolved 13 November 1984
Navigation
Issued 13 November 1984 Resolved
U.S. LIGHT LIST WAS OUTDATED (1982).
Condition: Unknown
Due 20 February 1987
Resolved 13 November 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.