Records from 1986 to 2006. Most recent: inspection, 23 October 2006.
Inspection history · 35
23 October 2006
Deficiency Check · Random ISPS/MTSA-No PSC
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2806069
30 May 2006
PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2663988
1 April 2005
ISPS II Exam · Ballast Water Examination · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2324677
28 April 2004
PII Safety Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2054604
17 December 2003
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1965810
8 August 2003
Ballast Water Examination · Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1870550
5 March 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1753225
4 March 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1752756
29 January 2003
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1736813
28 January 2003
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1737445
18 March 2002
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1492713
6 June 2001
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 290657
12 June 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 278905
10 December 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 435648
12 November 1999
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 434456
14 July 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 430540
10 November 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 422314
19 August 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 419505
28 July 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 405807
12 July 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 392936
4 April 1996
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 389628
18 July 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 380604
8 January 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 363467
2 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 504254
20 January 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 93578
17 September 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 352944
25 February 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 448635
26 August 1991
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 345448
24 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 338923
10 June 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 330888
18 May 1988
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 323386
13 December 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 535011
23 March 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 314981
2 October 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 448708
17 March 1986
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 307543
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 30 May 2006
Resolved
Crewmembers birthday on ANOA is incorrect. Submit update to NVMC prior to departure.
Action required: 705 - Other - as specified
Due 30 May 2006
Resolved 30 May 2006
Resolution: Submitted while onboard.
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 30 May 2006
Resolved
Ships crew has installed an air compressor in steering space with a homemade air receiver. Class to approve the installation of this system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 June 2006
Resolved 5 July 2006
Resolution: Received Class Report attesting to the disconnection of electrical supply for compressor, the receiver has been disconnected from the compressor, and the compressor has been labeled "Out of Service".
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 May 2006
Resolved
Seawater inlet line has a rubber patch and clamp. This line is seawater cooling for generator. Patch is located lower level engine room, starboard side in way of frames 27-30. This entire pipe length to be inspected for condition, make permanent repairs to patch and any other areas to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 29 June 2006
Resolved 29 June 2006
Resolution: Received Class Report attesting that the seawater inlet line was renewed and the entire length of pipe was satisfactorily inspected.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 30 May 2006
Resolved
Sewage holding tank is wasted and has soft patches around the top and backside. Repair the tank prior to next us port after sailing foreign to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 October 2006
Resolution: Received Class Report attesting to the repair of sewage holding tank and verified by Port State Control Officer.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 30 May 2006
Resolved
Starboard anchor windlass motor has hydraulic oil leak. Make proper repairs to satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 July 2006
Resolution: Received Class Report attesting to the satisfactory examination and testing of the starboard anchor windlass with no visible oil leakage.
Construction/Loadline › Structures › Door
Issued 28 April 2004
Resolved
Numerous doors in bulkheads into the superstructure are not weather tight and/or are unable to be operated from both sides of the bulkhead. Check and repair all doors as needed, to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Due 1 June 2004
Resolved 1 April 2005
Resolution: Item cleared during inspection
Construction/Loadline › Hull
Issued 17 December 2003
Resolved
Repair the 3 fractures in cargohold. a. Fracture at top portside of cargohold in port ballst wing tank. b. Similar fracture in same general area starboard. c. 1\2 - 3\4 forward portside of wing ballast tank at top. To satisfaction of class/ flag administration. LEGACY COMPONENT DESC: Wing Tank
Action required: 17 - Rectify deficiencies prior to departure
Due 17 December 2003
Resolved 17 December 2003
Resolution: Crack were drill stoped and welded as per class society rerecommendations.
Engineering › Steering Gear System
Issued 29 January 2003
Resolved
REMOVE NAKED HEAT LAMPS MOUNTED IN COFFEE CANS FROM SERVICE IN AFT STEERING COMPARTMENT AND ENGINE ROOM, ON VARIOUS PUMP MOTORS. Complete within 30 days.
Due 28 February 2003
Resolved 8 August 2003
Resolution: Heat lamps were replaced by new ones.
Documentation
Issued 14 July 1999
Resolved
Oil Transfer Procedures incomplete.
Condition: Unknown
Due 14 August 1999
Resolved 15 July 1999
Construction/Loadline
Issued 14 July 1999
Resolved
Starboard #2 top service tank and #5 ballast tank securing valves are not closing properly.
Condition: Unknown
Due 15 November 1999
Resolved 15 November 1999
Unknown
Issued 19 August 1998
Resolved
GUAGES ON EMERGENCY FIRE PUMP DID NOT FUNCTION.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Unknown
Issued 19 August 1998
Resolved
ALARM AND OIL CONTENT METER DID NOT FUNCTION PROPERLY.
Condition: Unknown
Due 10 November 1998
Resolved 10 November 1998
Navigation
Issued 18 May 1988
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MOST CURRENT ED OF U.S. TIDAL CURRENT TABLES, OR ITS FOREIGN EQUIV, AS REQUIRED BY 33 CFR 164.33(A)(3)(II) WAS NOT O/B. THE VSL DID NOT HAVE ANY U.S. TIDAL CURRENT TABLES OR ITS FOREIGNEQUIV O/B. THE MOST CURRENT ED IS DATED 1988.
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Navigation
Issued 23 March 1987
Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO PORTLAND, OREGON WITH CHARTS OF THE AREA NAVIGATED CONTAINING NO CORRECTIONS FROM APPLICABLE NOTICE TO MARINERS.
Condition: Unknown
Due 23 March 1987
Resolved 23 March 1987