Records from 1987 to 1999. Most recent: inspection, 27 February 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
27 February 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 426056
30 January 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 412133
23 September 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 408466
23 September 1997
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1111272
4 April 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 402289
19 August 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 689367
14 June 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 88347
11 June 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 392193
11 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 201468
11 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 450751
11 April 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 753329
14 November 1994
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1398162
9 September 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 370438
8 September 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1374132
25 July 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869106
13 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 362783
13 December 1993
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1160075
29 August 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 360458
5 July 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 359319
13 May 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 30752
13 May 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 511090
2 February 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1139204
21 October 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 476793
21 October 1992
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1253162
12 May 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 445396
22 October 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 651227
1 October 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 533635
1 October 1991
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1251699
14 July 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 524452
17 September 1990
Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 928451
3 December 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 526268
1 March 1989
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1195432
23 October 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 460113
27 February 1988
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026020
26 February 1988
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 444140
17 August 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 441785
4 July 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 490603
12 January 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 313921
12 January 1987
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1313323
Deck/Cargo
Issued 23 September 1997
Resolved
PRIOR TO LOADING CARGO MAKE PERMENANT REPAIRS TO PIN HOLR LEAK IN WAY OF #3PORT AND STARBOARD WBT. ALL REPAIRS TO BE COMPLEATED TO THE SATISFACTION OF CLASS AND IN NO CASE LATER THAN 22OCT97.
Condition: Unknown
Due 30 January 1998
Resolved 30 January 1998
Navigation
Issued 4 April 1997
Resolved
_x001C_ RECEIVED FAX REQUESTING TEMPORARY EQUIVALENCY TO TITLE _x001C_ 33CFR157.440. LETTER ISSUED._x001C_
Condition: Unknown
Due 6 October 1997
Resolved 6 October 1997
Deck/Cargo
Issued 8 September 1994
Resolved
THE HIGH GAS TEMPERATURE ALARM REQUIRED FOR THE I.G.S. IS TO HAVE BOTH AN AUDIBLE AND VISUAL ALARM, THERE WAS ONLY THE VISUAL ALARM IN THE CONTROL ROOM.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Navigation
Issued 8 September 1994
Resolved
THE LOW HYDRAULIC OIL SUMP ALARM FOR THE STEERING SYSTEM REQUIRED TO BE ON THE BRIDGE, WAS INOPERABLE. THE ALARM WAS THERE BUT NO AUDIBLE OR VISUAL MEANS WERE CAPABLE.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Deck/Cargo
Issued 8 September 1994
Resolved
PRESSURE AND TEMPERATURE GUAGES REQUIRED FOR THE I.G.S. WERE MISSING, IN THE CONTROL ROOM.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Deck/Cargo
Issued 8 September 1994
Resolved
AS REQUIRERED BY SOLAS CHAPTER II-2 REGULATION 62-18.
Condition: Unknown
Due 19 September 1994
Resolved 19 September 1994
Engineering
Issued 8 September 1994
Resolved
THE TEST CONDUCTED ON THE 15 PPM OILY WATER SEPARATOR, PROVED THAT THE _x001C_ AUDIBLE ALARM WAS INSUFFICENT.
Condition: Unknown
Due 8 September 1994
Resolved 8 September 1994
Deck/Cargo
Issued 13 December 1993
Resolved
PRIOR TO NEXT U.S. PORT, RENEW THE SIGHT GLASS TO THE INERT GAS SYSTEM DECKSEAL.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Deck/Cargo
Issued 13 December 1993
Resolved
PRIOR TO NEXT U.S. PORT, MAKE PERMANENT REPAIRS TO THE HEATING COIL LINE TOTHE INERT GAS SYSTEM DECK SEAL.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Construction/Loadline
Issued 13 December 1993
Resolved
PRIOR TO NEXT U.S. PORT, REPAINT THE NAME OF THE VESSEL ON THE STARBOARD SIDE FORWARD.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Documentation
Issued 21 October 1992
Resolved
PRIOR TO RETURNING TO NEXT US PORT, PROVIDE FOAM ANALYSIS REPORT.
Condition: Unknown
Due 21 October 1992
Resolved 21 October 1992
Accommodation/Occupational Safety
Issued 1 October 1991
Resolved
VESSEL IS TO BE IN COMPLETE COMPLIANCE WITH ILO 147 PRIOR TO RETURN TO U.S.WATERS, BUT NOT LATER THAN 1 NOV 91._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Deck/Cargo
Issued 1 October 1991
Resolved
LABEL THE EMERGENCY SHUTDOWN HANDLES FOR CARGO PUMPROOM VENTILATION LOCATEDAT THE TOP AND BOTTOM OF THE CARGO PUMPROOM STAIRS. TO BE COMPLETED PRIOR TO RETURN TO U.S. WATERS BUT NOT LATER THAN 1 OCT 92._x001C_ _x001C_
Condition: Unknown
Due 1 October 1991
Resolved 1 October 1991
Navigation
Issued 1 March 1989
Resolved
VESSEL WAS MISSING U.S. COAST GUARD LIGHT LIST ISSUED DEFICIENCY TO CORRECTPRIOR TO DEPARTURE OF THE ZONE OF PHILADELPHIA 33 CFR 164.33 (A) (2) (II).
Condition: Unknown
Due 1 March 1989
Resolved 1 March 1989