Records from 1985 to 1990. Most recent: inspection, 29 March 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
29 March 1990
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1236481
28 March 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 336101
4 May 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 517082
29 April 1989
Certificate of Compliance · MARPOL Annex II Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1196486
8 December 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 514887
21 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 321681
21 February 1988
Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025697
14 July 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 317183
14 July 1987
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1024463
14 June 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1029714
18 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1006543
5 March 1987
Certificate of Compliance
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1319783
4 March 1987
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 519778
10 July 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 303659
Deck/Cargo
Issued 29 April 1989
Resolved
MAKE PERMANENT REPAIRS IN PLACE OF TEMP REPAIRS IN #6 STBD WING AFT OF V/V SS52.
Condition: Unknown
Due 29 April 1989
Resolved 29 April 1989
Deck/Cargo
Issued 29 April 1989
Resolved
HYDRO TEST CARGO & C.O.W. LINES TO 1.5 TIMES WORKING PRESSURE.
Condition: Unknown
Due 29 April 1989
Resolved 29 April 1989
Deck/Cargo
Issued 29 April 1989
Resolved
MAKE REPAIRS TO IGS SCRUBBER LOW FLOW ALARM AND BLOWER SHUTDOWN AND PROVE OPERATION TO C.G. PERSONNEL.
Condition: Unknown
Due 29 April 1989
Resolved 29 April 1989
Fire Fighting
Issued 29 April 1989
Resolved
HAVE FIREFIGHTING FORM TESTED AND PROVIDE REPORT TO C.G. PERSONNEL.
Condition: Unknown
Due 29 April 1989
Resolved 29 April 1989
Navigation
Issued 29 April 1989
Resolved
CHARTS & NAV-PUBS OUTDATED.
Condition: Unknown
Due 29 April 1989
Resolved 29 April 1989
Documentation
Issued 21 February 1988
Resolved
TVEL EXPIRED
Condition: Unknown
Due 21 February 1988
Resolved 21 February 1988
Navigation
Issued 5 March 1987
Resolved
PROCURE AND PROVIDE ON BOARD PRIOR TO DEPARTING PHILADELPHIA, A CURRENT OR UPDATED LIGHT LIST FOR THE DELAWARE BAY AND RIVER (33 CFR 164.33)
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Deck/Cargo
Issued 5 March 1987
Resolved
PROCURE AND INSTALL PRIOR TO RE-ENTERING U.S. WATERS MECHANICAL CLOSURES FOR DRAINS IN CARGO OIL DISCHARGE CONTAINMENT, PORT AND STARBOARD SIDES AT MANIFOLDS. (33 CFR 155.310(3))
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Fire Fighting
Issued 5 March 1987
Resolved
PROCURE FOUR (4) FIREPROOF LIFELINES FOR THE FIREMAN'S OUTFITS AS REQUIRED BY THE 1981 SOLAS AMENDMENTS, REG. 17.2, CHAP. II-2. LIFELINES MUST BE ON BOARD PRIOR TO DEPARTING PHILADELPHIA.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Documentation
Issued 5 March 1987
Resolved
PROVIDE ON BOARD A FLAG STATE APPROVED CRUDE OIL WASH MANUAL AND SUPPORTINGDOCUMENTS AS REQUIRED BY 33 CFR 157.118 PRIOR TO CONDUCTING ANY CRUDE OIL WASHING OF CARGO TANKS IN THE PHILADELPHIA ZONE.
Condition: Unknown
Due 5 March 1987
Resolved 5 March 1987
Deck/Cargo
Issued 10 July 1985
Resolved
PROVIDE PROPER STUFFING TUBE OR PLUG FOR ALL SENSORS PENETRETING PUMP ROOM ENGINE ROOM AND BULKHEAD
Condition: Unknown
Due 14 July 1987
Resolved 10 July 1985
Deck/Cargo
Issued 10 July 1985
Resolved
CLEAN UP EXCESS OIL IN GENERATING FLAT,AROUND SETLING TANKS, FUEL OIL PUMP AREA,ETC.
Condition: Unknown
Due 14 July 1987
Resolved 10 July 1985