Records from 2001 to 2026. Most recent: inspection, 27 April 2026.
Inspection history · 47
27 April 2026
COI Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8355514
9 September 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8230662
30 April 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8101426
28 April 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7903026
20 December 2023
Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7874161
26 September 2023
Hull Examination · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7803678
9 May 2023
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7676140
19 December 2022
Liferaft Servicing
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7612596
26 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7464925
9 September 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7300745
21 April 2021
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7173937
30 July 2020
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7021020
13 March 2020
Administrative Inspection · Deficiency Check · Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6965752
24 September 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6818740
15 August 2019
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6875644
22 April 2019
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6666272
4 December 2018
Liferaft Servicing
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6592279
14 June 2018
DAPI Audit
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6465304
1 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6421942
4 October 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6281515
24 April 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6128564
27 April 2016
Internal Structural Exam · Deficiency Check · Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5855139
9 May 2014
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4854481
26 July 2012
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 4423655
24 March 2010
Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3702266
11 May 2008
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3203716
10 April 2008
Hull Examination
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3181296
21 May 2007
Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2933409
5 July 2006
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2702932
27 June 2006
COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2692571
26 April 2006
Hull Examination · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2634383
18 June 2005
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2396481
6 June 2005
Annual Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2381715
15 April 2005
Examination of Repairs
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2342605
22 June 2004
Deficiency Check · Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2107038
7 April 2004
Hull Examination · Internal Structural Exam
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 2039593
28 May 2003
Annual Inspection · Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1803815
25 April 2003
Internal Structural Exam · Hull Examination
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1780695
10 February 2003
Drydock Extension
Administrative · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1743113
8 October 2002
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1686783
3 July 2002
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1640962
25 June 2002
Examination of Repairs · Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1637049
16 June 2002
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1632893
5 June 2002
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1628968
12 July 2001
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1068099
26 April 2001
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1373441
25 March 2001
Hull Examination · Deadweight Survey · Initial Certification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1459683
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 9 September 2025
Resolved
A hatch exposed to the weather must be watertight. Port and stbd side exhaust space freeman hatches have a pin hole leak. Plug to prevent water ingress.
46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 27 April 2026
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Welds at base of V strut on STBD side have porosity. Repair to satisfaction of USCG.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: Received documentation on repairs; all sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 September 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection. Port side propeller blade tip has damage. Repair to satisfaction of USCG.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 April 2026
Resolution: Propeller blade dip repairs; all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 September 2025
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant Officer in Charge, Marine Inspection. STBD FWD fire extinguisher needs to be recharged.
46 CFR 181.500
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2026
Resolution: All fire extinguishers were in good working order
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 April 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. STBD fire-boy system did not shut down main propulsion engine and powered ventilation. 46 CFR 181.420(a)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2025
Resolution: O/O demonstrated sat.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 April 2025
Resolved
At each initial and subsequent inspection for certification the owner shall be prepared to conduct test and have the vessel ready for inspection of its fire protection equipment, including the testing of ventilation shut downs. Port engine room ventilation closure obstructed by hose. 46 CFR 181.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2025
Resolution: Hose was moved and is not an obstruction anymore; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 30 April 2025
Resolved
In systems where flixible hoses are permitted to be clamped, double hose clamping is required. Double hose clamp raw water hoses in Engine rooms. 46 CFR 181.410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 April 2025
Resolution: Double clams applied to raw water hoses.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 April 2025
Resolved
A vessel must carry a first-aid kit approved under ISO 188113:2006 paragraph 4.12.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 May 2025
Resolution: O/O provided documentation, meeting regulatory requierments for medical kit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2024
Resolved
Where flexibility is necessary, a section of flexible metallic hose may be used. Nonmetallic hose may be
used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat,
has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. Stbd engine room flexible hose for wet exhaust water cooling system is missing double clamps on one end of the hose. 46CFR182.430(e)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2024
Resolution: Double clamps installed on both ends of hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2024
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Raw water hose for stbd engine is damaged (torn) at hose clamp section, reducing effectiveness of double clamps.46CFR182.200(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2024
Resolution: Raw water hose was cut shorter, removing the damaged area. Hose was re-installed with double clamps.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only
on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other
than a ferry, provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113 (incorporated by reference; see 46 CFR 175.600). Submersible bilge pumps in all compartments do not meet standard. Vessel maximum passenger capacity reduced to 12 passengers until owner/operator provides documentation attesting to submersible bilge pumps in port and stbd engine room being UL listed. All other submersible pumps on-board to meet standard within 30 days. 46CFR182.520(e)
Action required: 705 - Other - as specified
Resolved 7 May 2024
Resolution: Operator provided pictures of installed UL listed pumps. A total of 10 UL pumps were installed.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 29 April 2024
Resolved
Pre-employment testing requirements. (a) No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Crew did not complete pre-employment testing. 46CFR16.210(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2024
Resolution: Provided documentation attesting to crew members completing pre employment testing w/ neg results. 02 crew has not received test results. Operator was made aware that those crew cannot fill a safety sensitive position until neg results come in.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 29 April 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass is not illuminated. 46CFR184.402(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 May 2024
Resolution: Operator provided documentation showing compass ligh is operational again.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 April 2024
Resolved
The servicing facility must issue a certificate to the life raft owner or owner's agent for each liferaft it services. Servicing facility did not issue a life raft servicing certificate. 46CFR160.151-57(p)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 May 2024
Resolution: Liferaft servicing report was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 May 2023
Resolved
Individual power pumps used for separate spaces are to be controlled from a central control point and must have a light or other visual means at the control point to indicate operation. Starboard, forward bilge pump indicator light was inoperable when tested. Restore functionality.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2023
Resolution: Tested bilge pump and indicator light functioned properly.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 9 May 2023
Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station IAW Part III of Title III of the Communications Act must carry a radio operator...Master (Ketch) did not have a marine radio operator permit or other appropriate license. Provide proof of license. 47 CFR 80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2023
Resolved 28 May 2023
Resolution: Proof of marine radio operator permit obtained.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2023
Resolved
Abandon ship, man overboard and fire drils and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include: the date of the drill/training and a general description of the drill scenario and training topics. Vessel log did not include drill entries. Provide copy of May and June training and drill records.
Action required: 705 - Other - as specified
Due 30 June 2023
Resolved 13 June 2023
Resolution: Logs provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 26 April 2022
Resolved
Vessel's nav pubs were out of date. Provide current Coast Pilot [name withheld] and Current tables.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2021
Resolved
Provide means to prevent crew fro electrical shock in port engine room aft bulkhead on the positive terminal block.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2021
Resolution: cover installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 April 2021
Resolved
Provide Fire servicing reports for both installed pre-engineered fire extinguishing systems.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2021
Resolution: rcvd serviceing paperwork
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 21 April 2021
Resolved
Correctly install Float free link
Action required: 10 - Deficiency Rectified
Resolved 21 April 2021
Resolution: corrected
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2021
Resolved
Replace expired items in first aid kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2021
Resolution: items have been replaced
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2021
Resolved
Replace expired life ring buoy light battery
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2021
Resolution: new batery installed
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 1 May 2018
Resolved
Provide a charged 2-A (formerly A-II) portable extinguisher to cover the passenger accommodation space. - 46 CFR 181.500 - 31 MAY 2018
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 21 May 2018
Resolution: Received picture of charged fire extinguisher with new service tag.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 May 2018
Resolved
Replace burn gel and eyewash in first aid kit. - 46 CFR 185.700 - 31 MAY 2018
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2018
Resolved 11 May 2018
Resolution: Received photos of new burn gel and eyewash.
Navigation › Piloting/Steering › Marine Charts
Issued 24 April 2017
Resolved
Provide updated marine charts onboard the vessel. To the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 26 May 2017
Resolution: Owner properly updated nav charts and placed them onboard.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 24 April 2017
Resolved
Provide 2017 tides and currents onboard the vessel. To the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 8 May 2017
Resolved 26 May 2017
Resolution: Owner purchased 2017 tides and currents and placed them onboard.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 27 April 2016
Resolved
Post identification and operating instructions for both the port and stbd fixed fire systems manual release pull handles.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 6 May 2016
Resolution: Owner purchased operating instructions placards fm the system manufacture and installed at the operating handle on both the port & stbd fixed fire systems.
Lifesaving › Lifebuoys › Serviceable
Issued 27 April 2016
Resolved
Renew vsl's life ring buoy due to wasted grab line.
Action required: 705 - Other - as specified
Due 10 May 2016
Resolved 6 May 2016
Resolution: Owner purchased a new life ring buoy and stenciled vsl's name onto the same and put in place of the worn life ring buoy.
Construction/Loadline › Hull › Bottom Plating
Issued 27 April 2016
Resolved
Discovered minor stress cracks in the gel coating aprox 3', 3" wide section where the hulls meet the mid body and minor pitting in the gel coat on the port & stbd aft hulls where they meet the midbody. Submit repair proposal to the OCMI for pre-approval to make permanent repairs these areas of the hull on or before the vessels next hull exam. By specified date: 04/30/2018.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 1 May 2018
Resolution: Fairing cracks repaired with new, more flexible West System resin.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 11 May 2008
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 May 2008
Resolved 11 May 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 May 2008
Resolved
Renew vessel' certificate of documentation at NDC.
Condition: Unknown
Due 11 May 2008
Resolved 11 May 2008
Resolution: Owner [name withheld] showed evidence of renewal, sat., new certificate in the mail.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 27 June 2006
Resolved
Loose junction box for STBD engine room fire suppression system must be secured to bulkhead.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Verified that junction box is appropriately secured to bulkhead.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 June 2006
Resolved
Ensure up-to-date copy of Coast Guard Light List is available on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Verified presence of current pub.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 June 2006
Resolved
Ensure up-to-date copy of Tide/Tidal Current Tables is available on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Verified presence of current pub.
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 June 2006
Resolved
Ensure up-to-date copy of local US Coast Pilot is available on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Verified presence of current pub.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 27 June 2006
Resolved
Ensure up-to-date copy of 'Rules of the Road' is available on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Verified presence of current pub.
Engineering › Bilge Water Management System › Pump
Issued 27 June 2006
Resolved
Ensure portable bilge pump is available on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Inspector verified presence of bilge pump on vessel.
Documentation › Logs/Records › Drug Test Records
Issued 27 June 2006
Resolved
Ensure proof of enrollment in drug testing program is available on vessel.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Proof provided of enrollment in drug testing program.
Documentation › Certificates/Documents › FCC SSL
Issued 27 June 2006
Resolved
Ensure current FCC Safety Radio Certificate is available on vessel.
Action required: 705 - Other - as specified
Due 3 July 2006
Resolved 5 July 2006
Resolution: Verified FCC Safety Radio Certificate is present on vessel.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 26 April 2006
Resolved
Renew watertight seal for stuffing tubes in aft bulkhead of voids in wire penetration stuffing tubes.
Due 26 May 2006
Resolved 28 April 2006
Construction/Loadline › Hull › Stiffener
Issued 26 April 2006
Resolved
Repair minor delamination in shelf that supports rudder arms in both port and stbd hulls.
Due 26 May 2006
Resolved 28 April 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 6 June 2005
Resolved
Provide a CG approved first aid kit as per 46 CFR 184.710. Existing kit onboard found all items expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 27 June 2006
Resolution: First Aid kit observed on vessel.
Lifesaving › Hand Flares › Expired
Issued 6 June 2005
Resolved
Provide replacement for expired (3) distress signals and (3) smoke signals as per 46 CFR 180.68.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 18 June 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 6 June 2005
Resolved
Renew EPIRB automatic float free device, Hammer Hydrostatic release, expired June 2005 as per 46 CFR 180.64.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2005
Resolved 18 June 2005
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 June 2004
Resolved
Provide the original Certificat of Documentation onboard the vessel.
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 25 June 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 June 2004
Resolved
Repair and demonstrate operation of the starboard main engine automatic shutdown and override circuit (part of the fixed firefighting system).
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 25 June 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 June 2004
Resolved
Repair the broken actuation pull cable for the starboard main engineroom fixed firefighting system.
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 25 June 2004
Engineering › Bilge Water Management System › Piping
Issued 22 June 2004
Resolved
Correct the leakage problem in the discharge line of the starboard lazarette bilge pump.
Action required: 705 - Other - as specified
Due 25 June 2004
Resolved 25 June 2004
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 22 June 2004
Resolved
Provide an insulating cover for exposed terminals of the DC Positive Bus Bar in the port engineroom.
Action required: 705 - Other - as specified
Due 22 July 2004
Resolved 5 January 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 May 2003
Resolved
Provide guards for port and starboard main propulsion shafts and couplings per 46 CFR 177.960; No personnel are allowed to enter the engine compartments while shafts are engaged until this is corrected.
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 25 June 2004
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 28 May 2003
Resolved
Troubleshoot and prove operation of automatic engine shutdowns for fixed firefighting systems. LEGACY COMPONENT DESC: Operating Controls
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 26 June 2003
Communications › Radio Communications
Issued 28 May 2003
Resolved
Register the EPIRB and replace the expired hydrostatic release; also log monthly tests. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 26 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 28 May 2003
Resolved
Repair broken retention arm on overhead escape hatch.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 26 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 28 May 2003
Resolved
Securely attach plastic mesh on aft rails to allow openings no greater than 4" per 46 CFR 177.900(g). LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 26 June 2003
Operations/Management › Drug and Alcohol Testing
Issued 28 May 2003
Resolved
Fully implement an employee assistance program per 46 CFR 16.401. LEGACY COMPONENT DESC: EAP Training Requirements
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 26 June 2003
Electrical › Electrical Distribution System (service)
Issued 25 April 2003
Resolved
Provide drip proof cover for outlet in Port Engine Room. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 25 May 2003
Resolved 26 June 2003
Electrical › Electrical Distribution System (service)
Issued 25 April 2003
Resolved
Remove improper wiring - an extension cord that is permanently installed running from the stbd engine room through a transverse watertight bulkhead forward to a void space. LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 May 2003
Resolved 26 June 2003
Construction/Loadline › Hull
Issued 10 February 2003
Resolved
The vessel shall not carry passengers beyond 25 March, 2003 until such time as the vessel completes a credit drydock examination to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 1 June 2003
Resolved 25 April 2003
Resolution: Completed Credit Drydock
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 25 June 2002
Resolved
Repair/replace stbd rudder, prop, tailshaft, bearings, strut, and reduction gear assembly as original where necessary due to allision with submerged rock. LEGACY COMPONENT DESC: Gear, Timing
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2002
Resolution: All work completed this date.
Construction/Loadline › Hull
Issued 25 June 2002
Resolved
Repair bottom hull FRP fracture in way of stbd engine room and lazarette where damaged by allision with submerged rock. Submit for approval repair proposal to include area to be repaired, joint preparation and layup schedule. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Resolution: Approved repair proposal 29June2002. Fiberglass repairs completed 03July2002.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 5 June 2002
Resolved
Provide proof of current servicing for all portable fire extinguishers. LEGACY COMPONENT DESC: Service
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 16 June 2002
Resolution: Observed proper tags with current servicing data.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 5 June 2002
Resolved
Provide proof of servicing for fixed fire extinguishing systerms. Servicing must include testing of alarms and automatic shut downs.
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 6 July 2002
Resolution: Sighted current servicing tag.
Engineering › Fuel Oil Storage/Transfer System
Issued 5 June 2002
Resolved
Provide grounding wire to run length of fuel tank fill hose. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 8 October 2002
Resolution: Corected using 10 gage wire based on verbal statement of vessel operator.
Documentation › Certificates/Documents
Issued 5 June 2002
Resolved
Provide current FCC Marine Radio Operator's Permit for Glen Jacobsen.
Action required: 705 - Other - as specified
Due 5 July 2002
Resolved 6 July 2002
Resolution: Sighted current FCC radio operator''s permit
Fire Fighting
Issued 26 April 2001
Resolved
PROVIDE 3 FIRE BUCKETS PER 46 CFR 181.610.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Accommodation/Occupational Safety
Issued 25 March 2001
Resolved
Properly fix all labels on Emergency Exits, Fuel Shutoff Valves, LifejacketBins.
Condition: Unknown
Due 25 March 2001
Resolved 25 March 2001
Lifesaving
Issued 25 March 2001
Resolved
Properly attach painter and light to life ring.
Condition: Unknown
Due 25 March 2001
Resolved 25 March 2001
Unknown
Issued 25 March 2001
Resolved
Provide vessel for USCG "Welcome to the Zone" inspection.
Condition: Unknown
Due 25 March 2001
Resolved 25 March 2001
Documentation
Issued 25 March 2001
Resolved
Provide stability letter to USCG.
Condition: Unknown
Due 25 March 2001
Resolved 25 March 2001
Accommodation/Occupational Safety
Issued 25 March 2001
Resolved
Properly secure/lock sewage overboard shutoff valve.
Condition: Unknown
Due 25 March 2001
Resolved 25 March 2001