MARY STOVE
MARY STOVE is a 1974 tank ship. The Coast Guard has recorded 25 inspections since 1986, most recently in December 1998, along with 10 deficiencies and 1 operational control.
Records from 1986 to 1998. Most recent: inspection, 13 December 1998.
- Built
- 1974
- Last inspected
- 13 December 1998
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7371953 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
LAMG2
224366
Flag
PANAMA
—
Maury page id
psix-224366
Inspections, by type
…with no type recorded20
Years with a record
12 calendar years (1986–1998)
The 25 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 28 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it128303 - Dead Weight, Ton
46737 - Regulatory (Subpart C or D), Net Ton
69155 - Regulatory (Subpart C or D), Gross Ton
46737 - Regulatory (Subpart C or D), Net Ton
69155 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 25
13 December 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 423510
13 December 1998
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 808435
8 November 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 409747
4 November 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409752
30 August 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 395004
16 January 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 646171
23 October 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 84668
2 September 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 471529
3 February 1995
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 448354
23 January 1995
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 646172
10 November 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 372047
5 August 1994
Tank Vessel Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1363070
28 April 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 468122
13 April 1993
Deficiency Check · Certificate of Compliance
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 833605
26 February 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 494858
30 December 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1142011
24 December 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 829767
16 March 1992
Deficiency Check · Certificate of Compliance
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1261766
17 May 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 337089
28 December 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 514607
11 June 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 330947
11 June 1989
Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202698
5 May 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 323014
18 July 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022449
22 May 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 309017
Deficiency record · 10
Documentation
Issued 13 December 1998
Resolved
no certificate on board from class verifying the vapor collection system.
Deck/Cargo
Issued 10 November 1994
Resolved
VESSEL HAD CARGO DECK SCUPPERS PLUGGED WITH CEMENT AND WOODEN PLUGS. A MECHANICAL MEANS OF CLOSURE IS REQUIRED.
Lifesaving
Issued 5 August 1994
Resolved
PRIOR TO DEPARTURE FROM, TEXAS CITY, TEXAS REPLACE ALL WEATHER DAMAGED LIFERINGS.
Navigation
Issued 13 April 1993
Resolved
PRIOR TO DEPARTURE PORT OF PHILADELPHIA, PROVIDE CURRENT U.S. COAST PILOT, USCG LIGHT LIST, AND NOTICE TO MARINER.
Fire Fighting
Issued 13 April 1993
Resolved
PRIOR TO DEPARTURE PORT OF PHILADELPHIA, MAKE REPAIR AND DEMONSTRATE THE OPERATION OF EMERGENCY FIRE PUMP TO SATISFACTION OF U.S. COAST GUARD MARINEINSPECTOR.
Construction/Loadline
Issued 24 December 1992
Resolved
PRIOR TO RETURNING TO U.S. WATERS,MAKE PERMANENT REPAIRS TO LONGITUDINAL_x001C_ BULKHEAD BETWEEN NO.3 CARGO TANK AND NO.3 PORT BALLAST WING TANK. PROVIDE_x001C_ WRITTEN FLAG STATE/CLASS SOCIETY REPORT COMFIRMING PROPER REPAIRS.
Deck/Cargo
Issued 16 March 1992
Resolved
PROVE PROPER OPERATION OF #1 CARGO PUMP EMERGENCY SHUT OFF. PRIOR TO USE AFTER REPAIRS ARE MADE TO DRIVE TURBINE.
Accommodation/Occupational Safety
Issued 11 June 1989
Resolved
MARINE SANITATION DEVICE (MSD) HAD NO PROOF OF CERTIFICATION REQUIRED UNDER 33 CFR PART 159.
Navigation
Issued 5 May 1988
Resolved
PROVIDE REPAIRS FOR THE AUTOMATIC RADAR PLOTTING AID ON BOARD AND PROVE PROPER OPERATION IN ACCORDANCE WITH 33CFR164.38(B)(1).
Deck/Cargo
Issued 5 May 1988
Resolved
PROVIDE REPAIRS FOR THE INERT GAS SYSTEM OXYGEN GAS ANALYZER ON BOARD AND PROVE PROPER OPERATION IN ACCORDANCE WITH 46CFR32.53-60(B).
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.